Refer to the guide in the Epson XP 15000/15010/15080 Adjustment Program for the details of the procedure: Click here
This section provides the operating environment, functions related to safety and privacy policy, and the adjustment item newly added of the Adjustment Program.
The operating environment for the Epson XP 15000 Adjustment Program is as follows:
# OS: Windows 7, 8.1, 10
# Interface: USB 2.0
Epson XP-15000 AdjProg with “Initialize photo paper deterioration offset”
- Epson XP-15000 Adjustment Program message: “Initialize photo paper deterioration offset”
- Purpose:
- For high accuracy in printing on exclusive paper, perform deterioration correction for photo paper.
- To match the deterioration state of the PF Roller and the soft counter (exclusive paper deterioration offset counter) saved in the EEPROM, initializes the counter.
- Risks if the adjustment is not correctly made:
Non-uniformity of print result may occur because of mismatch between the deterioration state of the PF Roller and the soft counter.
- How to make initialize setting for photo paper deterioration offset on Epson XP 15000 AdjProg?
- Select from the menu of the Adjustment Program and press the “Initialization” button to initialize the exclusive paper deterioration offset.
- After pressing the button, the correction value is automatically measured and the measurement value is written to the EEPROM on the Main Board.
You may need do the procedure on the purple section of screen first, and do the manual on above the picture.
Epson XP-15000 AdjProg with “Photo sensor light level adjustment”
- Epson XP-15000 Adjustment Program message: “Photo sensor light level adjustment”
- Purpose:
- To adjust the current values supplied to the sensor to optimize the light amount of the PE / PW Sensor.
- Risks if the adjustment is not correctly made:
The value of current varies due to deterioration by mist or the characteristics of sensors or boards. As a result, the detection timing may be shifted and cause a negative influence on the printing quality.
- How to make setting for photo sensor light level on Epson XP 15000 AdjProg?
- Set bright white inkjet paper (A4) in 1st Bin cassette.
- Select from the menu of the Adjustment Program and select the relevant sensor’s check box. And then, press the “Perform” button to adjust.
- After the paper is fed and ejected, the correction value is automatically corrected and the measurement value is written to the EEPROM on the Main Board.
Check out the guide on the Epson XP-15000 AdjProg first, then follow it:
-
Set A4 or Letter size Plain Paper in the ASF
-
Select the sensor for the process
-
Click to the Perform button and then adjust the light level of specified photo sensor.
Epson XP-15000 AdjProg with “Initialize PW sensor deterioration counter”
-
Epson XP-15000 Adjustment Program message: “Initialize PW sensor deterioration counter”
- Purpose:
- Initializes the counter to reset the soft counter saved on the EEPROM (PF deterioration offset soft counter) to
fit the PW sensor deterioration condition by ink mist.
- Initializes the counter to reset the soft counter saved on the EEPROM (PF deterioration offset soft counter) to
- Risks if the adjustment is not correctly made:
Mismatch between the PW sensor deterioration condition and the soft counter may result, which may cause an uniformity of paper margin.
- How to make initialize setting for PW sensor deterioration counter on Epson XP 15000 AdjProg?
- Select from the menu of the Adjustment Program and press the “Initialization” button to initialize the PW deterioration offset.
- After pressing the button, the PW deterioration correction value is automatically initialized and the initial value is written to the EEPROM on the Main Board.
— You find the guides for Epson XP 15000,15010,15080 remove Main Frame, click here
— Or click here if you want to disassembly Epson XP 15000,15010,15080 Exterior Pars.
Epson XP-15000 AdjProg Release CR Lock
- Purpose:
- Releases the CR Lock
- How to make initialize setting for PW sensor deterioration counter on Epson XP 15000 AdjProg?
- Select from the menu of the Adjustment Program and press the “Perform” button to release the CR Lock
- After pressing the button, the CR Lock is released