- Code: 0001
- Description: SCAN MOTOR ERROR
- Causes: Feed Motor Deviation Error (The order from the CPU does not match the feedback of the Feed Motor.)
- Troubleshooting Guides: < External factors > 1. Media Jamming 2. Pull or move the carriage by hands. 3. Carriage runs into a thing or hands. 4. Media is stuck because it is caught by the paper pipe. 5. Media is pulled forcedly. 6. Too heavy media is loaded. < Machine factors > 1. The grease lubrication of the motor gear is not enough. 2. Motor is broken or end of life. 3. Servo board is broken. 4. Tool carriage fi xation to the belt is loose. 5. The bearing inside the idle pulley is worn out. 6. The carriage belt loses steps. (The symptom may be improved by greasing the belt.) 7. Limit position is not appropriate. (When the limit position is not correctly set, it may cause a scan motor error.) 8. Power supply for motor is broken. (When the power supply voltage for the motor is not supplied, the motor cannot move and it results in the motor error. )
- Code: 0002
- Description: Disorder of communication with Sub CPU This occurs when the Sub CPU is not detected after turning on the machine.
- Causes: Servo Board does not work correctly. Sub CPU does not work correctly. There is a bad connection between Main Board and Servo Board.
- Troubleshooting Guides: Check cable connection between Main Board and Servo Board. Check the other cable connections of Servo Board. Servo Board replacement Main Board replacement Flexible cable replacement
- Code: 0004
- Description: Sub CPU SRAM error
- Causes: SRAM is broken.
- Troubleshooting Guides: Servo Board replacement
- Code: 0004
- Description: SCAN MOTOR ERROR
- Causes: Feed Motor Overcurrent Error 1 (Big load is put on the motor movement instantaneously.)
- Troubleshooting Guides: < External factors > 1. Media Jamming 2. Pull or move the carriage by hands. 3. Carriage runs into a thing or hands. 4. Media is stuck because it is caught by the paper pipe. 5. Media is pulled forcedly. 6. Too heavy media is loaded. < Machine factors > 1. The grease lubrication of the motor gear is not enough. 2. Motor is broken or end of life. 3. Servo board is broken. 4. Tool carriage fi xation to the belt is loose. 5. The bearing inside the idle pulley is worn out. 6. The carriage belt loses steps. (The symptom may be improved by greasing the belt.) 7. Limit position is not appropriate. (When the limit position is not correctly set, it may cause a scan motor error.) 8. Power supply for motor is broken. (When the power supply voltage for the motor is not supplied, the motor cannot move and it results in the motor error. )
- Code: 0005
- Description: An error occurs during downloading a program for sub CPU.
- Causes: Servo Board does not work correctly. Sub CPU does not work correctly. There is a bad connection between Main Board and Servo Board. A noise on a signal
- Troubleshooting Guides: Check cable connection between Main Board and Servo Board. Check the other cable connections of Servo Board. Servo Board replacement Main Board replacement Flexible cable replacement
- Code: 0005
- Description: SCAN MOTOR ERROR
- Causes: Feed Motor Deviation Error (The order from the CPU does not match the feedback of the Feed Motor.) Feed Motor Overcurrent Error 1 (Big load is put on the motor movement instantaneously.)
- Troubleshooting Guides: < External factors > 1. Media Jamming 2. Pull or move the carriage by hands. 3. Carriage runs into a thing or hands. 4. Media is stuck because it is caught by the paper pipe. 5. Media is pulled forcedly. 6. Too heavy media is loaded. < Machine factors > 1. The grease lubrication of the motor gear is not enough. 2. Motor is broken or end of life. 3. Servo board is broken. 4. Tool carriage fi xation to the belt is loose. 5. The bearing inside the idle pulley is worn out. 6. The carriage belt loses steps. (The symptom may be improved by greasing the belt.) 7. Limit position is not appropriate. (When the limit position is not correctly set, it may cause a scan motor error.) 8. Power supply for motor is broken. (When the power supply voltage for the motor is not supplied, the motor cannot move and it results in the motor error. )
- Code: 0006
- Description: An error occurs when trying to connect with sub CPU.
- Causes: A noise on a signal while sending a command Sub CPU was reset to default. Tried to communicate when Sub CPU was reset to default.
- Troubleshooting Guides: Check cable connection between Main Board and Servo Board. Check the other cable connections of Servo Board. Servo Board replacement Main Board replacement Flexible cable replacement
- Code: 0007
- Description: An error occurs while sending a command.
- Causes: Servo Board does not work correctly. Sub CPU does not work correctly. There is a bad connection between Main Board and Servo Board. A noise on a signal while sending a command Sub CPU was reset while sending a command.
- Troubleshooting Guides: Check cable connection between Main Board and Servo Board. Check the other cable connections of Servo Board. Servo Board replacement Main Board replacement Flexible cable replacement
- Code: 0008
- Description: There is a problem with synchronizing serial communication to Sub CPU.
- Causes: Servo Board does not work correctly. Sub CPU does not work correctly. There is a bad connection between Main Board and Servo Board. A noise on a signal
- Troubleshooting Guides: Check cable connection between Main Board and Servo Board. Check the other cable connections of Servo Board. Servo Board replacement Main Board replacement Flexible cable replacement
- Code: 0008
- Description: SCAN MOTOR ERROR
- Causes: Feed Motor Overcurrent Error 2 (A little load is put on the motor movement for a long time.)
- Troubleshooting Guides: < External factors > 1. Media Jamming 2. Pull or move the carriage by hands. 3. Carriage runs into a thing or hands. 4. Media is stuck because it is caught by the paper pipe. 5. Media is pulled forcedly. 6. Too heavy media is loaded. < Machine factors > 1. The grease lubrication of the motor gear is not enough. 2. Motor is broken or end of life. 3. Servo board is broken. 4. Tool carriage fi xation to the belt is loose. 5. The bearing inside the idle pulley is worn out. 6. The carriage belt loses steps. (The symptom may be improved by greasing the belt.) 7. Limit position is not appropriate. (When the limit position is not correctly set, it may cause a scan motor error.) 8. Power supply for motor is broken. (When the power supply voltage for the motor is not supplied, the motor cannot move and it results in the motor error. )
- Code: 0009
- Description: SCAN MOTOR ERROR
- Causes: Feed Motor Deviation Error (The order from the CPU does not match the feedback of the Feed Motor.) Feed Motor Overcurrent Error 2 (A little load is put on the motor movement for a long time.)
- Troubleshooting Guides: < External factors > 1. Media Jamming 2. Pull or move the carriage by hands. 3. Carriage runs into a thing or hands. 4. Media is stuck because it is caught by the paper pipe. 5. Media is pulled forcedly. 6. Too heavy media is loaded. < Machine factors > 1. The grease lubrication of the motor gear is not enough. 2. Motor is broken or end of life. 3. Servo board is broken. 4. Tool carriage fi xation to the belt is loose. 5. The bearing inside the idle pulley is worn out. 6. The carriage belt loses steps. (The symptom may be improved by greasing the belt.) 7. Limit position is not appropriate. (When the limit position is not correctly set, it may cause a scan motor error.) 8. Power supply for motor is broken. (When the power supply voltage for the motor is not supplied, the motor cannot move and it results in the motor error. )
- Code: 000C
- Description: SCAN MOTOR ERROR
- Causes: Feed Motor Overcurrent Error 1 (Big load is put on the motor movement instantaneously.) Feed Motor Overcurrent Error 2 (A little load is put on the motor movement for a long time.)
- Troubleshooting Guides: < External factors > 1. Media Jamming 2. Pull or move the carriage by hands. 3. Carriage runs into a thing or hands. 4. Media is stuck because it is caught by the paper pipe. 5. Media is pulled forcedly. 6. Too heavy media is loaded. < Machine factors > 1. The grease lubrication of the motor gear is not enough. 2. Motor is broken or end of life. 3. Servo board is broken. 4. Tool carriage fi xation to the belt is loose. 5. The bearing inside the idle pulley is worn out. 6. The carriage belt loses steps. (The symptom may be improved by greasing the belt.) 7. Limit position is not appropriate. (When the limit position is not correctly set, it may cause a scan motor error.) 8. Power supply for motor is broken. (When the power supply voltage for the motor is not supplied, the motor cannot move and it results in the motor error. )
- Code: 0010
- Description: SCAN MOTOR ERROR
- Causes: Scan Motor Deviation Error (The order from the CPU does not match the feedback of the Scan Motor.)
- Troubleshooting Guides: < External factors > 1. Media Jamming 2. Pull or move the carriage by hands. 3. Carriage runs into a thing or hands. 4. Media is stuck because it is caught by the paper pipe. 5. Media is pulled forcedly. 6. Too heavy media is loaded. < Machine factors > 1. The grease lubrication of the motor gear is not enough. 2. Motor is broken or end of life. 3. Servo board is broken. 4. Tool carriage fi xation to the belt is loose. 5. The bearing inside the idle pulley is worn out. 6. The carriage belt loses steps. (The symptom may be improved by greasing the belt.) 7. Limit position is not appropriate. (When the limit position is not correctly set, it may cause a scan motor error.) 8. Power supply for motor is broken. (When the power supply voltage for the motor is not supplied, the motor cannot move and it results in the motor error. )
- Code: 0010
- Description: Network I/F Initialize has not been completed.
- Causes: Network I/F does not work correctly. Firmware for Network I/F is not installed.
- Troubleshooting Guides: Check the fi rmware is installed into Network I/F. Main Board replacement
- Code: 0040
- Description: SCAN MOTOR ERROR
- Causes: Scan Motor Overcurrent Error 1 (Big load is put on the motor movement instantaneously.)
- Troubleshooting Guides: < External factors > 1. Media Jamming 2. Pull or move the carriage by hands. 3. Carriage runs into a thing or hands. 4. Media is stuck because it is caught by the paper pipe. 5. Media is pulled forcedly. 6. Too heavy media is loaded. < Machine factors > 1. The grease lubrication of the motor gear is not enough. 2. Motor is broken or end of life. 3. Servo board is broken. 4. Tool carriage fi xation to the belt is loose. 5. The bearing inside the idle pulley is worn out. 6. The carriage belt loses steps. (The symptom may be improved by greasing the belt.) 7. Limit position is not appropriate. (When the limit position is not correctly set, it may cause a scan motor error.) 8. Power supply for motor is broken. (When the power supply voltage for the motor is not supplied, the motor cannot move and it results in the motor error. )
- Code: 0050
- Description: SCAN MOTOR ERROR
- Causes: Scan Motor Deviation Error (The order from the CPU does not match the feedback of the Scan Motor.) Scan Motor Overcurrent Error 1 (Big load is put on the motor movement instantaneously.)
- Troubleshooting Guides: < External factors > 1. Media Jamming 2. Pull or move the carriage by hands. 3. Carriage runs into a thing or hands. 4. Media is stuck because it is caught by the paper pipe. 5. Media is pulled forcedly. 6. Too heavy media is loaded. < Machine factors > 1. The grease lubrication of the motor gear is not enough. 2. Motor is broken or end of life. 3. Servo board is broken. 4. Tool carriage fi xation to the belt is loose. 5. The bearing inside the idle pulley is worn out. 6. The carriage belt loses steps. (The symptom may be improved by greasing the belt.) 7. Limit position is not appropriate. (When the limit position is not correctly set, it may cause a scan motor error.) 8. Power supply for motor is broken. (When the power supply voltage for the motor is not supplied, the motor cannot move and it results in the motor error. )
- Code: 0080
- Description: SCAN MOTOR ERROR
- Causes: Scan Motor Overcurrent Error 2 (A little load is put on the motor movement for a long time.)
- Troubleshooting Guides: < External factors > 1. Media Jamming 2. Pull or move the carriage by hands. 3. Carriage runs into a thing or hands. 4. Media is stuck because it is caught by the paper pipe. 5. Media is pulled forcedly. 6. Too heavy media is loaded. < Machine factors > 1. The grease lubrication of the motor gear is not enough. 2. Motor is broken or end of life. 3. Servo board is broken. 4. Tool carriage fi xation to the belt is loose. 5. The bearing inside the idle pulley is worn out. 6. The carriage belt loses steps. (The symptom may be improved by greasing the belt.) 7. Limit position is not appropriate. (When the limit position is not correctly set, it may cause a scan motor error.) 8. Power supply for motor is broken. (When the power supply voltage for the motor is not supplied, the motor cannot move and it results in the motor error. )
- Code: 0090
- Description: SCAN MOTOR ERROR
- Causes: Scan Motor Deviation Error (The order from the CPU does not match the feedback of the Scan Motor.) Scan Motor Overcurrent Error 2 (A little load is put on the motor movement for a long time.)
- Troubleshooting Guides: < External factors > 1. Media Jamming 2. Pull or move the carriage by hands. 3. Carriage runs into a thing or hands. 4. Media is stuck because it is caught by the paper pipe. 5. Media is pulled forcedly. 6. Too heavy media is loaded. < Machine factors > 1. The grease lubrication of the motor gear is not enough. 2. Motor is broken or end of life. 3. Servo board is broken. 4. Tool carriage fi xation to the belt is loose. 5. The bearing inside the idle pulley is worn out. 6. The carriage belt loses steps. (The symptom may be improved by greasing the belt.) 7. Limit position is not appropriate. (When the limit position is not correctly set, it may cause a scan motor error.) 8. Power supply for motor is broken. (When the power supply voltage for the motor is not supplied, the motor cannot move and it results in the motor error. )
- Code: 00C0
- Description: SCAN MOTOR ERROR
- Causes: Scan Motor Overcurrent Error 1 (Big load is put on the motor movement instantaneously.) Scan Motor Overcurrent Error 2 (A little load is put on the motor movement for a long time.)
- Troubleshooting Guides: < External factors > 1. Media Jamming 2. Pull or move the carriage by hands. 3. Carriage runs into a thing or hands. 4. Media is stuck because it is caught by the paper pipe. 5. Media is pulled forcedly. 6. Too heavy media is loaded. < Machine factors > 1. The grease lubrication of the motor gear is not enough. 2. Motor is broken or end of life. 3. Servo board is broken. 4. Tool carriage fi xation to the belt is loose. 5. The bearing inside the idle pulley is worn out. 6. The carriage belt loses steps. (The symptom may be improved by greasing the belt.) 7. Limit position is not appropriate. (When the limit position is not correctly set, it may cause a scan motor error.) 8. Power supply for motor is broken. (When the power supply voltage for the motor is not supplied, the motor cannot move and it results in the motor error. )
- Code: 0101
- Description: Limit Position Initialize in the Service Mode has not been done.
- Causes: Limit Position Initialize has not been done. Limit Position Initialize is ended before it is completed.
- Troubleshooting Guides: Complete Limit Position Initialize correctly.
- Code: 0102
- Description: Head Lock Sensor is ON when it should be OFF, or vice versa.
- Causes: Head Lock Sensor does not work correctly or is broken. Head Carriage is not located at the correct position.
- Troubleshooting Guides: Head Lock Sensor replacement Check the mechanical backlash or loose with the scan axis related parts.
- Code: 0103
- Description: Limit Sensor is ON when it should be OFF, or vice versa.
- Causes: Limit Sensor does not work correctly or is broken. Tool Carriage is not located at the correct position.
- Troubleshooting Guides: Limit Sensor replacement Check the mechanical backlash or loose with the scan axis related parts. Revised 1
- Code: 0105
- Description: Tool Carriage Connection Error
- Causes: Fault of Tool Carriage Connection Loose of Connection Part Fault of the Limit Position Initialize value Limit Sensor does not work correctly or is broken.
- Troubleshooting Guides: Check the mechanical Backlash or loose with the Tool Carriage part. Connection Part Replacement Limit Position Initialize
- Code: 0106
- Description: Machine fails to disconnect the Tool Carriage from the Head Carriage.
- Causes: Fault of Tool Carriage Connection Loose of Connection Part Fault of the Limit Position Initialize value Limit Sensor does not work correctly or is broken.
- Troubleshooting Guides: Check the mechanical Backlash or loose with the Tool Carriage part. Connection Part Replacement Limit Position Initialize
- Code: 0107
- Description: Linear Encoder Setup has not been done.
- Causes: Linear Encoder Setup has not been done. Linear Encoder Setup is ended before it is completed.
- Troubleshooting Guides: Carry out Linear Encoder Setup in service menu.
- Code: 0109
- Description: Wiper unit does not work correctly.
- Causes: Wiper Unit hits the Tool Carriage Wiper Motor error Defect of Wiper Unit Defect of Wiper Sensor Cut-line or short-circuit of cable and Flexible cable
- Troubleshooting Guides: Move the Head Carriages on the bed not to hit the Wiper Unit. Wiper Motor Replacement Wiper Unit Replacement Wiper Sensor Replacement Cable and Flexible Cable Replacement
- Code: 0110
- Description: Input value from Linear Encoder is not changed by the Linear Encoder origin setup. When Motor stops during printing, expected movement is not completed on some head.
- Causes: Read error of Linear Encoder Read error of Encoder on Scan Motor side Belt is not fi xed to Head Carriage fi rmly.
- Troubleshooting Guides: Confi rm whether Encoder Scale is in the slit of Encoder Module in a whole width of the machine. Check cable connection between Linear Encoder Board and Main Board. Confi rm connection between Belt and Tool Carriage. Linear Encoder replacement Scan Motor replacement Servo Board replacement Main Board replacement
- Code: 0111
- Description: This error occurs when the machine performs the Auto Crop Mark Detection before performing Crop- Cut Adjustment.
- Causes: Crop-Cut Adjustment in the Service menu has not been performed.
- Troubleshooting Guides: Carry out Crop-Cut Adjustment in service menu.
- Code: 0112
- Description: Communication error with Cartridge IC driver
- Causes: Cartridge IC driver is broken. Cartridge IC driver cable has short circuited or cut-line.
- Troubleshooting Guides: Ink cartridge IC sensor replacement
- Code: 0130
- Description: There is a problem with Thermistor for Print Heater.
- Causes: Thermistor cable has short circuited or cutline. Thermistor has a problem.
- Troubleshooting Guides: Check cable connection around Thermistor. Thermistor replacement
- Code: 0135
- Description: Print Heater temperature has reached 60°C and above.
- Causes: Print Heater Cable connection has a problem. Thermostat has a problem. Thermistor has a problem.
- Troubleshooting Guides: Check Print Heater. Check Thermostat. Check Thermistor.
- Code: 0140
- Description: There is a problem with Thermistor for dryer.
- Causes: Thermistor cable has short circuited or cutline. Thermistor has a problem.
- Troubleshooting Guides: Check Cable connection around Thermistor. Thermistor replacement
- Code: 0145
- Description: Dryer temperature has reached 80°C and above.
- Causes: Dryer cable connection has a problem. Thermostat has a problem. Thermistor has a problem.
- Troubleshooting Guides: Check Dryer. Check Thermostat. Check Thermistor.
- Code: 0250
- Description: There is a problem with Head device.
- Causes: Head is broken.
- Troubleshooting Guides: Head replacement
About Canon Servie Tool V5610
– Canon Service Tool V5610 is a tool used to perform maintenance on Canon printers and reset Canon printers after replacement of parts such as replacing ink absorbents, print heads, printer mainboard, and others. Based on the many cases we have encountered, the Service Tool is most often used to reset ink absorber counter value when the waste ink absorber is full.
– The ink absorber is going to be full of box, it has to be replaced or cleaned the waste ink absorber. Also, replaceing or cleaning the waste ink absorber, you need to repair or reset the waste ink counter value, cause those parts are concerned to each others.
– So using Canon Service Tool V5610 to reset the waste ink counter value becomes effective when the ink absorber is replaced or cleaned.
– Canon Service Tool V5610 can use to fix error code 5B00, 5B02, 5B04, 5B14, 1701, 1702, 1700 on your printer. You must enter Service Mode on your printer to use this Canon Service Tool.
– If the printer can not enter Service Mode, you can not reset it by Canon ST V5610. In this case, change EEPROM on the logic board.
Canon Service Tool V5610 Functions
– Fix Canon printer 7 times/ 8 times red light blinking:
– Fix Canon printer error code: 5B00, 5B01, 1700, 1701
Enter Service Mode on Canon Printer
1. Turn off a printer
2. Press and hold the Resume/Cancel/Stop button
3. Press and hold the ON button (do not release both buttons)
4. Release the Resume/Cancel/Stop button (do not release the ON button)
5. While holding the ON button, press the Resume/Cancel/Stop button 5 times, then release both the ON and Resume/Cancel/Stop buttons together.
– Canon printer in service mode: computer detects new hardware, led on printer goes green light.
For more information about Canon Serice Tool V5610
Contact us to get support with Roland VS540i VersaCamm Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/