Solved Roland AJ1000 AdvancedJet Error Codes
– Printer model: Roland AJ1000 AdvancedJet
– Error codes on Roland AJ1000 AdvancedJet model and its description:
– Roland AJ1000 AdvancedJet printer Error Codes and quick guide to troubleshooting:
- Code: 0002
- Description: Disorder of communication with Sub CPU
- Causes: Sub Board does not work correctly. Sub CPU does not work correctly. There is a bad connection between Heater Board and Servo Board. There is a bad connection between Main Board and Heater Board.
- Troubleshooting Guides: Check Cable connection between Main Board and Servo Board Check Cable connection between Servo Board and Heater Board Check the other Cable connection Servo Board replacement Heater Board replacement Main Board replacement
- Code: 0004
- Description: SRAM error
- Causes: SRAM has broken.
- Troubleshooting Guides: Servo Board replacement Heater Board replacement
- Code: 0005
- Description: An error occurs during downloading a program for sub CPU.
- Causes: Sub Board does not work correctly. Sub CPU does not work correctly. There is a bad connection between Heater Board and Servo Board. There is a bad connection between Main Board and Heater Board. A noise on a signal.
- Troubleshooting Guides: Check Cable connection between Main Board and Servo Board Check Cable connection between Servo Board and Heater Board Check the other Cable connection Servo Board replacement Heater Board replacement Main Board replacement
- Code: 0006
- Description: An error occurs when start connecting to sub CPU.
- Causes: A noise on a signal during sending a command. Sub CPU was reset to default. Get into communicate when Sub CPU was reset to default.
- Troubleshooting Guides: Check Cable connection between Main Board and Servo Board Check Cable connection between Servo Board and Heater Board Check the other Cable connection Servo Board replacement Heater Board replacement Main Board replacement
- Code: 0007
- Description: An error occurs during sending a command.
- Causes: Sub Board does not work correctly. Sub CPU does not work correctly. There is a bad connection between Main Board and Servo Board. There is a bad connection between Main Board and Heater Board. A noise on a signal during sending a command. Sub CPU was reset during sending a command.
- Troubleshooting Guides: Check Cable connection between Main Board and Servo Board Check Cable connection between Servo Board and Heater Board Check the other Cable connection Servo Board replacement Heater Board replacement Main Board replacement
- Code: 0008
- Description: There is a problem with synchronizing serial communication to Sub CPU.
- Causes: Sub Board does not work correctly. Sub CPU does not work correctly. There is a bad connection between Heater Board and Servo Board. There is a bad connection between Main Board and Heater Board. A noise on a signal.
- Troubleshooting Guides: Check Cable connection between Main Board and Servo Board Check Cable connection between Servo Board and Heater Board Check the other Cable connection Servo Board replacement Heater Board replacement Main Board replacement
- Code: 0101
- Description: Limit Position Initialize has not been done.
- Causes: Limit Position Initialize has not been done.
- Troubleshooting Guides: Carry out Limit Position Initialize
- Code: 0102
- Description: Even though the machine carries out the regular movement, the output of Limit Sensor does not reach the expected value.
- Causes: Limit Sensor does not work correctly or is broken.
- Troubleshooting Guides: Limit Sensor replacement Check the mechanical backlash or loose with the scanning axes
- Code: 0107
- Description: Linear Encoder Setup has not been done.
- Causes: Linear Encoder Setup has not been done.
- Troubleshooting Guides: Carry out Linear Encoder Setup
- Code: 0110
- Description: Input value from Linear Encoder is not changed when Linear Encoder is setup the origin. When Motor stops during printing, Motor does not complete the movement which is supposed to be done.
- Causes: Read error of Linear Encoder. Read error of Encoder on Scan Motor side. Wire is not fixed to Head Carriage firmly.В
- Troubleshooting Guides: Confirm whether Encoder Scale is between the slit of Encoder Module in a whole width of the machine Check Cable connection between Linear Encoder Board and Print Carriage Board Confirm connection between Wire and Head Carriage Linear Encoder replacement Scan Motor replacement Main Board replacement
- Code: 0120
- Description: There is a problem with Thermistor for Pre-Heater F.
- Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
- Troubleshooting Guides: Check Cable connection around Thermistor Thermistor replacement
- Code: 0121
- Description: There is a problem with thermistor for Pre-Heater R.
- Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
- Troubleshooting Guides: Check Cable connection around Thermistor Thermistor replacement
- Code: 0125
- Description: Heater is unusually hot. Pre-Heater F temperature has reached 60°C and above.
- Causes: Heater Cable connection has a problem. Thermostat has a problem (not working). Thermistor has a problem.
- Troubleshooting Guides: Check Heater Check Thermostat Check Thermistor
- Code: 0126
- Description: Heater is unusually hot. Pre-Heater F temperature has reached 60°C and above.
- Causes: Heater Cable connection has a problem. Thermostat has a problem (not working). Thermistor has a problem.
- Troubleshooting Guides: Check Heater Check Thermostat Check Thermistor
- Code: 0130
- Description: There is a problem with Thermistor for Print Heater.
- Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
- Troubleshooting Guides: Check Cable connection around Thermistor Thermistor replacement
- Code: 0135
- Description: Heater is unusually hot. Print Heater temperature has reached 60°C and above.
- Causes: Heater Cable connection has a problem. Thermostat has a problem (not working). Thermistor has a problem.
- Troubleshooting Guides: Check Heater Check Thermostat Check Thermistor
- Code: 0140
- Description: There is a problem with Thermistor for dryer (2 lines/upper).
- Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
- Troubleshooting Guides: Check Cable connection around Thermistor Thermistor replacement
- Code: 0141
- Description: There is a problem with Thermistor for dryer (2 lines/middle).
- Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
- Troubleshooting Guides: Check Cable connection around Thermistor Thermistor replacement
- Code: 0142
- Description: Thermistor for dryer (2 lines/lower).
- Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
- Troubleshooting Guides: Check Cable connection around Thermistor Thermistor replacement
- Code: 0145
- Description: Heater is unusually hot. Dryer (2 lines/upper) temperature has reached 80°C and above.
- Causes: Heater Cable connection has a problem. Thermostat has a problem (not working). Thermistor has a problem.
- Troubleshooting Guides: Check Heater Check Thermostat Check Thermistor
- Code: 0146
- Description: Heater is unusually hot. Dryer (2 lines/middle) temperature has reached 80°C and above.
- Causes: Heater Cable connection has a problem. Thermostat has a problem (not working). Thermistor has a problem.
- Troubleshooting Guides: Check Heater Check Thermostat Check Thermistor
- Code: 0147
- Description: Heater is unusually hot. Dryer (2 lines/lower) temperature has reached 80°C and above.
- Causes: Heater Cable connection has a problem. Thermostat has a problem (not working). Thermistor has a problem.
- Troubleshooting Guides: Check Heater Check Thermostat Check Thermistor
- Code: 0150
- Description: Even though the machine carries out the regular movement, the output of Slider Sensor does not reach the expected value.
- Causes: Slider Motor has a problem. Slider Sensor has a problem. Wiring or Flexible Cable has short circuitted or cut-line. Servo Board has a problem.
- Troubleshooting Guides: Check Cable connection of Servo Board Check Cable connection of Junction Board Slider Motor replacement Slider Sensor replacement Wiring or Flexible Cable replacement Servo Board replacement
- Code: 0151
- Description: Even though the machine carries out the regular movement, the output of Head Rise and Fall Sensor does not reach the expected value. problem.
- Causes: Head Rise and Fall Motor has a problem. Head Rise and Fall Sensor has a problem. Wiring or Flexible Cable has short circuitted or cut-line. Servo Board has a problem.
- Troubleshooting Guides: Check Cable connection of Servo Board Check Cable connection of Junction Board Head Rise and Fall Motor replacement Head Rise and Fall Sensor replacement Wiring or Flexible Cable replacement Servo Board replacement
- Code: 0152
- Description: Even though the machine carries out the regular movement, the output of Wiper Sensor does not reach the expected value.
- Causes: Wiper Motor has a problem. Wiper Sensor has a problem. Wiring or Flexible Cable has short circuitted or cut-line. Servo Board has a problem.
- Troubleshooting Guides: Check Cable connection of Servo Board Check Cable connection of Junction Board Wiper Motor replacement Wiper Sensor replacement Wiring or Flexible Cable replacement Servo Board replacement
- Code: 0160
- Description: Even though the machine carries out the regular movement, the output of Pressure Pump 1 Sensor does not reach the expected value.
- Causes: Pressure Pump 1 Motor has a problem. Pressure Pump 1 Sensor has a problem. Pressure Pump 1 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem.
- Troubleshooting Guides: Check Cable connection of Servo Board Check Cable connection of Junction Board Check Pressure Pump 1 Magnet Pressure Pump 1 Motor replacement Pressure Pump 1 Sensor replacement Wiring or Flexible Cable replacement Pump Drive Board replacement Servo Board replacement
- Code: 0161
- Description: Even though the machine carries out the regular movement, the output of Pressure Pump 2 Sensor does not reach the expected value.
- Causes: Pressure Pump 2 Motor has a problem. Pressure Pump 2 Sensor has a problem. Pressure Pump 2 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem.
- Troubleshooting Guides: Check Cable connection of Servo Board Check Cable connection of Junction Board Check Pressure Pump 2 Magnet Pressure Pump 2 Motor replacement Pressure Pump 2 Sensor replacement Wiring or Flexible Cable replacement Pump Drive Board replacement Servo Board replacement
- Code: 0162
- Description: Even though the machine carries out the regular movement, the output of Pressure Pump 3 Sensor does not reach the expected value.
- Causes: Pressure Pump 3 Motor has a problem. Pressure Pump 3 Sensor has a problem. Pressure Pump 3 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem.
- Troubleshooting Guides: Check Cable connection of Servo Board Check Cable connection of Junction Board Check Pressure Pump 3 Magnet Pressure Pump 3 Motor replacement Pressure Pump 3 Sensor replacement Wiring or Flexible Cable replacement Pump Drive Board replacement Servo Board replacement
- Code: 0163
- Description: Even though the machine carries out the regular movement, the output of Pressure Pump 4 Sensor does not reach the expected value.
- Causes: Pressure Pump 4 Motor has a problem. Pressure Pump 4 Sensor has a problem. Pressure Pump 4 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem.
- Troubleshooting Guides: Check Cable connection of Servo Board Check Cable connection of Junction Board Check Pressure Pump 4 Magnet Pressure Pump 4 Motor replacement Pressure Pump 4 Sensor replacement Wiring or Flexible Cable replacement Pump Drive Board replacement Servo Board replacement
- Code: 0164
- Description: Even though the machine carries out the regular movement, the output of Pressure Pump 5 Sensor does not reach the expected value.
- Causes: Pressure Pump 5 Motor has a problem. Pressure Pump 5 Sensor has a problem. Pressure Pump 5 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem.
- Troubleshooting Guides: Check Cable connection of Servo Board Check Cable connection of Junction Board Check Pressure Pump 5 Magnet Pressure Pump 5 Motor replacement Pressure Pump 5 Sensor replacement Wiring or Flexible Cable replacement Pump Drive Board replacement Servo Board replacement
- Code: 0165
- Description: Even though the machine carries out the regular movement, the output of Pressure Pump 6 Sensor does not reach the expected value.
- Causes: Pressure Pump 6 Motor has a problem. Pressure Pump 6 Sensor has a problem. Pressure Pump 6 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem.
- Troubleshooting Guides: Check Cable connection of Servo Board Check Cable connection of Junction Board Check Pressure Pump 6 Magnet Pressure Pump 6 Motor replacement Pressure Pump 6 Sensor replacement Wiring or Flexible Cable replacement Pump Drive Board replacement Servo Board replacement
- Code: 0170
- Description: Even though the machine carries out the regular movement, the output of Supply Pump 1 Sensor does not reach the expected value.
- Causes: Supply Pump 1 Motor has a problem. Supply Pump 1 Sensor has a problem. Supply Pump 1 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem.
- Troubleshooting Guides: Check Cable connection of Servo Board Check Cable connection of Junction Board Check Supply Pump 1 Magnet Supply Pump 1 Motor replacement Supply Pump 1 Sensor replacement Wiring or Flexible Cable replacement Pump Drive Board replacement Servo Board replacement
- Code: 0171
- Description: Even though the machine carries out the regular movement, the output of Supply Pump 2 Sensor does not reach the expected value.
- Causes: Supply Pump 2 Motor has a problem. Supply Pump 2 Sensor has a problem. Supply Pump 2 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem.
- Troubleshooting Guides: Check Cable connection of Servo Board Check Cable connection of Junction Board Check Supply Pump 2 Magnet Supply Pump 2 Motor replacement Supply Pump 2 Sensor replacement Wiring or Flexible Cable replacement Pump Drive Board replacement Servo Board replacement
- Code: 0172
- Description: Even though the machine carries out the regular movement, the output of Supply Pump 3 Sensor does not reach the expected value.
- Causes: Supply Pump 3 Motor has a problem. Supply Pump 3 Sensor has a problem. Supply Pump 3 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem.
- Troubleshooting Guides: Check Cable connection of Servo Board Check Cable connection of Junction Board Check Supply Pump 3 Magnet Supply Pump 3 Motor replacement Supply Pump 3 Sensor replacement Wiring or Flexible Cable replacement Pump Drive Board replacement Servo Board replacement
- Code: 0173
- Description: Even though the machine carries out the regular movement, the output of Supply Pump 4 Sensor does not reach the expected value.
- Causes: Supply Pump 4 Motor has a problem. Supply Pump 4 Sensor has a problem. Supply Pump 4 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem.
- Troubleshooting Guides: Check Cable connection of Servo Board Check Cable connection of Junction Board Check Supply Pump 4 Magnet Supply Pump 4 Motor replacement Supply Pump 4 Sensor replacement Wiring or Flexible Cable replacement Pump Drive Board replacement Servo Board replacement
- Code: 0174
- Description: Even though the machine carries out the regular movement, the output of Supply Pump 5 Sensor does not reach the expected value.
- Causes: Supply Pump 5 Motor has a problem. Supply Pump 5 Sensor has a problem. Supply Pump 5 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem.
- Troubleshooting Guides: Check Cable connection of Servo Board Check Cable connection of Junction Board Check Supply Pump 5 Magnet Supply Pump 5 Motor replacement Supply Pump 5 Sensor replacement Wiring or Flexible Cable replacement Pump Drive Board replacement Servo Board replacement
- Code: 0175
- Description: Even though the machine carries out the regular movement, the output of Supply Pump 6 Sensor does not reach the expected value.
- Causes: Supply Pump 6 Motor has a problem. Supply Pump 6 Sensor has a problem. Supply Pump 6 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem.
- Troubleshooting Guides: Check Cable connection of Servo Board Check Cable connection of Junction Board Check Supply Pump 6 Magnet Supply Pump 6 Motor replacement Supply Pump 6 Sensor replacement Wiring or Flexible Cable replacement Pump Drive Board replacement Servo Board replacement
- Code: 0180
- Description: Even though the machine carries out the regular movement, the output of Maintenance Liquid Pump Sensor does not reach the expected value.
- Causes: Maintenance Liquid Pump Motor has a problem. Maintenance Liquid Pump Sensor has a problem. Maintenance Liquid Pump Magnet has dropped out. Wiring or Flexible Cable has short circuitted
- Troubleshooting Guides: Check Cable connection of Servo Board Check Cable connection of Junction Board Maintenance Liquid Pump Motor replacement Maintenance Liquid Pump Sensor replacement Wiring or Flexible Cable replacement Servo Board replacement
- Code: 0190
- Description: Thermistor under the BED has a problem.
- Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
- Troubleshooting Guides: Thermistor replacement Check Cable connection Heater Board replacement
- Code: 0200
- Description: Head 1 is abnormally hot. Head 1 temperature has reached 58°C and above.
- Causes: Thermistor (Head) has a problem. Flexible Cable has short circuitted or cut-line. Wiring of Head Heater has a problem.
- Troubleshooting Guides: Check Flexible Cable connection around Head Check Cable connection around Heater Head replacement
- Code: 0201
- Description: Head 2 is abnormally hot. Head 2 temperature has reached 58°C and above.
- Causes: Thermistor (Head) has a problem. Flexible Cable has short circuitted or cut-line.
- Troubleshooting Guides: Check Flexible Cable connection around Head Head replacement
- Code: 0202
- Description: Head 3 is abnormally hot. Head 3 temperature has reached 58°C and above.
- Causes: Thermistor (Head) has a problem. Flexible Cable has short circuitted or cut-line.
- Troubleshooting Guides: Check Flexible Cable connection around Head Head replacement
- Code: 0203
- Description: Head 4 is abnormally hot. Head 4 temperature has reached 58°C and above.
- Causes: Thermistor (Head) has a problem. Flexible Cable has short circuitted or cut-line.
- Troubleshooting Guides: Check Flexible Cable connection around Head Head replacement
- Code: 0204
- Description: Head 5 is abnormally hot. Head 5 temperature has reached 58°C and above.
- Causes: Thermistor (Head) has a problem. Flexible Cable has short circuitted or cut-line.
- Troubleshooting Guides: Check Flexible Cable connection around Head Head replacement
- Code: 0205
- Description: Head 6 is abnormally hot. Head 6 temperature has reached 58°C and above.
- Causes: Thermistor (Head) has a problem. Flexible Cable has short circuitted or cut-line.
- Troubleshooting Guides: Check Flexible Cable connection around Head Head replacement
About Canon Servie Tool V5610
– Canon Service Tool V5610 is a tool used to perform maintenance on Canon printers and reset Canon printers after replacement of parts such as replacing ink absorbents, print heads, printer mainboard, and others. Based on the many cases we have encountered, the Service Tool is most often used to reset ink absorber counter value when the waste ink absorber is full.
– The ink absorber is going to be full of box, it has to be replaced or cleaned the waste ink absorber. Also, replaceing or cleaning the waste ink absorber, you need to repair or reset the waste ink counter value, cause those parts are concerned to each others.
– So using Canon Service Tool V5610 to reset the waste ink counter value becomes effective when the ink absorber is replaced or cleaned.
– Canon Service Tool V5610 can use to fix error code 5B00, 5B02, 5B04, 5B14, 1701, 1702, 1700 on your printer. You must enter Service Mode on your printer to use this Canon Service Tool.
– If the printer can not enter Service Mode, you can not reset it by Canon ST V5610. In this case, change EEPROM on the logic board.
Canon Service Tool V5610 Functions
– Fix Canon printer 7 times/ 8 times red light blinking:
– Fix Canon printer error code: 5B00, 5B01, 1700, 1701
Enter Service Mode on Canon Printer
1. Turn off a printer
2. Press and hold the Resume/Cancel/Stop button
3. Press and hold the ON button (do not release both buttons)
4. Release the Resume/Cancel/Stop button (do not release the ON button)
5. While holding the ON button, press the Resume/Cancel/Stop button 5 times, then release both the ON and Resume/Cancel/Stop buttons together.
– Canon printer in service mode: computer detects new hardware, led on printer goes green light.
For more information about Canon Serice Tool V5610
Contact us to get support with Roland AJ1000 AdvancedJet Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/