[SOLVED] Quick fix Konica-Minolta Pro 958 list error codes
– Compatible Printer model: Konica-Minolta bizhub Pro 958
– Konica-Minolta bizhub Pro 958 Error Codes with quick guides:
- Code: 10-01, 10-02, 10-40
- Description: Misfeed at manual bypass feed section. 10-01 The leading edge of the paper does not turn ON the tray 1 vertical transport sensor (PS4) even after the lapse of a given period of time after the manual bypass tray starts to feed paper. 10-02 For paper fed from the manual bypass tray, loop forming has not been complete before a sheet enters the registration roller because the rise timing of load to perform registration is earlier than the rise timing of load to form a loop. 10-40 For paper fed from the manual bypass tray, the image write start signal permit continues to be disabled for a predetermined period of time after the timing of the image write start signal output. – When the main power switch is turned ON, residual paper detection starts between each sensor. Paper jam of a sheet of paper left at the manual bypass feed section results, if the the tray 1 vertical transport sensor (PS4) is turned from OFF to ON while the tray 1 paper feed sensor (PS5) is OFF.
- Causes: • Bypass paper feed motor (M27) • Tray 1 vertical transport sensor (PS4) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS4 I/O check, sensor check PFTDB CN14-8 (ON) 1-P 3 M27 operation check PFTDB CN9-3 to 6 12-P 4 PFTDB F11 conduction check – – 5 Replace PFTDB. – – 6 Replace MFPB.
- Code: 11-01, 11-02, 11-40
- Description: Misfeed at tray 1 feed section. 11-01 The leading edge of the paper does not turn ON the tray 1 vertical transport sensor (PS4) even after the lapse of a given period of time after the tray 1 starts to feed paper. 11-02 For paper fed from the tray 1, due to a delay in paper arrival, loop forming in front of the registration roller is not complete before the rise timing of the registration motor. 11-40 For paper fed from the tray 1, the image write start signal permit continues to be disabled for a predetermined period of time after the timing of the image write start signal output. – Paper jam of a sheet of paper left at the tray 1 feed section results, if the tray 1 vertical transport sensor (PS4) is turned ON when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset. – When the main power switch is turned ON, residual paper detection starts between each sensor. Paper jam of a sheet of paper left at the tray 1 feed section results, if the tray 1 vertical transport sensor (PS4) is turned from OFF to ON while the tray 1 paper feed sensor (PS5) is OFF.
- Causes: • Paper feed motor (M22) • Tray 1 paper feed clutch (CL1) • Tray 1 vertical transport sensor (PS4) • Tray 1 paper feed sensor (PS5) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS4 I/O check, sensor check PFTDB CN14-8 (ON) 1-P 3 PS5 I/O check, sensor check PFTDB CN14-5 (ON) 1-P 4 CL1 operation check PFTDB CN14-14 (REM) 2-P 5 M22 operation check PFTDB CN10-1 to 4 13-P 6 PFTDB F11 or F12 conduction check – – 7 Replace PFTDB. – – 8 Replace MFPB.
- Code: 12-01, 12-40
- Description: Misfeed at tray 2 feed section. 12-01 The leading edge of the paper does not turn ON the tray 2 vertical transport sensor (PS12) even after the lapse of a given period of time after the tray 2 starts to feed paper. 12-40 For paper fed from the tray 2, the image write start signal permit continues to be disabled for a predetermined period of time after the timing of the image write start signal output. – Paper jam of a sheet of paper left at the tray 2 feed section results, if the tray 2 vertical transport sensor (PS12) is turned ON when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset. – When the main power switch is turned ON, residual paper detection starts between each sensor. Paper jam of a sheet of paper left at the tray 2 feed section results, if the tray 2 vertical transport sensor (PS12) is turned from OFF to ON.
- Causes: • Paper feed motor (M22) • Tray 2 paper feed clutch (CL2) • Tray 2 vertical transport sensor (PS12) • Tray 2 paper feed sensor (PS13) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS12 I/O check, sensor check PFTDB CN12-10 (ON) 3-P 3 PS13 I/O check, sensor check PFTDB CN12-7 (ON) 3-P 4 CL2 operation check PFTDB CN12-1 (REM) 2-P 5 M22 operation check PFTDB CN10-1 to 4 13-P 6 PFTDB F11 or F12 conduction check – – 7 Replace PFTDB. – – 8 Replace MFPB.
- Code: 13-01, 13-40
- Description: Misfeed at tray 3 feed section. 13-01 The leading edge of the paper does not turn ON (block) the tray 3 paper feed sensor (PS21) even after the lapse of a given period of time after the tray 3 starts to feed paper. 13-40 For paper fed from the tray 3, the image write start signal permit continues to be disabled for a predetermined period of time after the timing of the image write start signal output. – Paper jam of a sheet of paper left at the tray 3 feed section results, if the tray 3 paper feed sensor (PS21) is turned ON (blocked) when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
- Causes: • LCC transport motor (M25) • Tray 3 paper feed clutch (CL5) • Tray 3 paper feed sensor (PS21) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS21 I/O check, sensor check PFTDB CN17-9 (ON) 6-X 3 CL5 operation check PFTDB CN16-5 (REM) 5-X 4 M25 operation check PFTDB CN13-1 to 7 11-X 5 PFTDB F12 or F15 conduction check – – 6 Replace PFTDB. – – 7 Replace MFPB.
- Code: 14-01, 14-40
- Description: Misfeed at tray 4 feed section. 14-01 The leading edge of the paper does not turn ON (unblock) the tray 4 paper feed sensor (PS26) even after the lapse of a given period of time after the tray 4 starts to feed paper. 14-40 For paper fed from the tray 4, the image write start signal permit continues to be disabled for a predetermined period of time after the timing of the image write start signal output. – Paper jam of a sheet of paper left at the tray 4 feed section results, if the tray 4 paper feed sensor (PS26) is turned ON (unblocked) when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
- Causes: • LCC transport motor (M25) • Tray 4 paper feed clutch (CL7) • Tray 4 paper feed sensor (PS26) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS26 I/O check, sensor check PFTDB CN19-3 (ON) 7-X 3 CL7 operation check PFTDB CN18-2 (REM) 7-X 4 M25 operation check PFTDB CN13-1 to 7 11-X 5 PFTDB F12 or F15 conduction check – – 6 Replace PFTDB. – – 7 Replace MFPB.
- Code: 15-01, 15-40
- Description: LCT feed section (When LU-205 or LU303 is installed). 15-01 The leading edge of the paper does not turn ON the LU paper feed sensor (PS3) even after the lapse of a given period of time after the LCT starts to feed paper. 15-40 For paper fed from the LCT, the image write start signal permit continues to be disabled for a predetermined period of time after the timing of the image write start signal output.
- Causes: • LU paper feed motor (M2) • LU paper feed sensor (PS3) • LU drive board (LUDB) • Paper feed/transport drive board (PFTDB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS3 I/O check, sensor check LUDB CN5-8 (ON) LU-205/LU-303 4-G 3 M2 operation check LUDB CN4-5 to 8 LU-205/LU-303 3-G 4 Replace LUDB. (LU-205/LU-303) – – 5 PFTDB F1 or F4 conduction check – – 6 Replace PFTDB.
- Code: 17-20
- Description: Misfeed at LCT transport section (When LU-205 or LU303 is installed). 17-20 The tray 2 vertical transport sensor (PS12) is not turned ON even after the set period of time has elapsed after the LU paper feed sensor (PS3) turns ON by a paper. – Paper jam of a sheet of paper left at the LCT transport section results, if the LU paper feed sensor (PS3) is turned ON when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
- Causes: • LU transport motor (M3) • LU paper feed sensor (PS3) • Tray 2 vertical transport sensor (PS12) • LU drive board (LUDB) • Paper feed/transport drive board (PFTDB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS3 I/O check, sensor check LUDB CN5-8 (ON) LU-205/LU-303 4-G 3 PS12 I/O check, sensor check PFTDB CN12-10 (ON) 3-P 4 M3 operation check LUDB CN4-1 to 4 LU-205/LU-303 3-G 5 Replace LUDB. (LU-205/LU-303) – – 6 PFTDB F1 or F4 conduction check – – 7 Replace PFTDB.
- Code: 17-30, 17-31
- Description: Tray 3/4 horizontal transport section. 17-30 The horizontal transport sensor (PS29) is not turned ON (blocked) even after the set period of time has elapsed after the tray 3 paper feed sensor (PS3) turns ON (block) by a paper. 17-31 The LCC vertical transport sensor (PS28) is not turned ON even after the set period of time has elapsed after the horizontal transport sensor (PS29) turns ON (block) by a paper. – Paper jam of a sheet of paper left at the tray 3/4 horizontal transport section results, if the horizontal transport sensor (PS29) is turned ON (blocked) when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
- Causes: • LCC transport motor (M25) • Tray 3 transport clutch (CL6) • Horizontal transport clutch (CL3) • Tray 3 paper feed sensor (PS21) • Horizontal transport sensor (PS29) • LCC vertical transport sensor (PS28) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS21 I/O check, sensor check PFTDB CN17-9 (ON) 6-X 3 PS28 I/O check, sensor check PFTDB CN15-15 (ON) 10-X 4 PS29 I/O check, sensor check PFTDB CN15-13 (ON) 10-X 5 CL3 operation check PFTDB CN15-5 (REM) 9-X 6 CL6 operation check PFTDB CN17-10 (REM) 6-X 7 M25 operation check PFTDB CN13-1 to 7 11-X 8 PFTDB F12 or F15 conduction check – – 9 Replace PFTDB. – – 10 Replace MFPB.
- Code: 17-40, 17-41
- Description: Tray 3/4 intermediate transport roller section. 17-40 The LCC vertical transport sensor (PS28) is not turned ON even after the set period of time has elapsed after the tray 4 paper feed sensor (PS26) turns ON (unblock) by a paper. 17-41 The tray 2 vertical transport sensor (PS12) is not turned ON even after the set period of time has elapsed after the LCC vertical transport sensor (PS28) turns ON by a paper. – Paper jam of a sheet of paper left at the tray 3/4 intermediate transport roller section results, if the LCC vertical transport sensor (PS28) is turned ON when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
- Causes: • LCC transport motor (M25) • LCC vertical transport motor (M28) • Tray 2 vertical transport motor (M7) • Tay4 paper feed clutch (CL7) • Tray 2 vertical transport sensor (PS12) • Tray 4 paper feed sensor (PS26) • LCC vertical transport sensor (PS28) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS12 I/O check, sensor check PFTDB CN12-10 (ON) 3-P 3 PS26 I/O check, sensor check PFTDB CN19-3 (ON) 7-X 4 PS28 I/O check, sensor check PFTDB CN15-15 (ON) 10-X 5 CL7 operation check PFTDB CN18-2 (REM) 7-X 6 M25 operation check PFTDB CN13-1 to 7 11-X 7 M28 operation check PFTDB CN11-1 to 4 10-X 8 M7 operation check PFTDB CN10-9 to 12 13-P 9 PFTDB F11, F12, F13, or F15 conduction check – – 10 Replace PFTDB. – – 11 Replace MFPB.
- Code: 20-01, 20-02, 20-03, 20-20
- Description: Misfeed at vertical transport section. 20-01 The registration sensor (PS38) is not turned ON (unblocked) even after the lapse of a given period of time after the tray 1 vertical transport sensor (PS4) turns ON by a paper. 20-02 For paper fed from the tray 2, tray 3, tray 4 or LU-205/LU-303, loop forming has not been complete before a sheet enters the registration roller because the rise timing of load to perform registration is earlier than the rise timing of load to form a loop. 20-03 The registration sensor (PS40) is not turned ON even after the lapse of a given period of time after the tray 1 vertical transport sensor (PS4) turns ON by a paper. 20-20 The tray 1 vertical transport sensor (PS4) is not turned ON even after the lapse of a given period of time after the tray 2 vertical transport sensor (PS12) turns ON by a paper.
- Causes: • Tray 1 vertical transport motor (M5) • Tray 2 vertical transport motor (M7) • Tray 1 vertical transport sensor (PS4) • Tray 2 vertical transport sensor (PS12) • Registration sensor (PS38) • OHP sensor (PS40) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS4 I/O check, sensor check PFTDB CN14-8 (ON) 1-P 3 PS12 I/O check, sensor check PFTDB CN12-10 (ON) 3-P 4 PS38 I/O check, sensor check PFTDB CN2-6 (ON) 4-P 5 PS40 I/O check, sensor check PFTDB CN2-3 (REM) 4-P 6 M5 operation check PFTDB CN10-5 to 8 13-P 7 M7 operation check PFTDB CN10-9 to 12 13-P 8 PFTDB F13 conduction check – – 9 Replace PFTDB. – – 10 Replace MFPB.
- Code: 30-03
- Description: Misfeed at 2nd transfer section. 30-03 The paper exit sensor (PS39) is not turned ON (unblocked) even after the set period of time has elapsed after the registration sensor (PS38) turns ON (unblocked) by a paper. – Paper jam of a sheet of paper left at the 2nd transfer section results, if the registration sensor (PS38) is turned ON (unblocked) when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset. – Paper jam of a sheet of paper left at the 2nd transfer section results, if the OHP sensor (PS40) is turned ON when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset. – When the main power switch is turned ON, residual paper detection starts between each sensor. Paper jam of a sheet of paper left at the 2nd transfer section results, if the registration sensor (PS38) or paper exit sensor (PS39) is turned from OFF (unblocked) to ON (blocked).
- Causes: • Registration motor (M2) • Fusing motor (M30) • Registration sensor (PS38) • OHP sensor (PS40) • Paper exit sensor (PS39) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS38 I/O check, sensor check PFTDB CN2-6 (ON) 4-P 3 PS40 I/O check, sensor check PFTDB CN2-3 (REM) 4-P 4 PS39 I/O check, sensor check PFTDB CN2-12 (ON) 5-P 5 M2 operation check PFTDB CN7-1 to 4 8-P 6 M30 operation check MFPB CN16-4 (REM) MFPB CN16-7 (LOCK) 10-K 7 PFTDB F16 conduction check – – 8 Replace PFTDB. – – 9 MFPB F14E conduction check – – 10 Replace MFPB.
- Code: 32-01, 32-05, 32-30
- Description: Misfeed at exit section. 32-01 The ADU paper passage sensor/1 (PS47) is not turned ON (blocked) even after the lapse of a given period of time after the reverse sequence is started. 32-05 The paper exit sensor (PS39) is not turned OFF (blocked) even after the lapse of a given period of time after PS3 turns ON (unblock) by a paper. 32-30 Heating roller assy had a trouble rotating while printing. – Paper jam of a sheet of paper left at the exit section results, if the paper exit sensor (PS39) is turned ON (unblocked) when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
- Causes: • Exit motor (M4) • Fusing motor (M30) • ADU transport motor/1 (M31) • Switchback motor (M33) • Gate switch solenoid (SD1) • Paper exit sensor (PS39) • ADU paper passage sensor/1 (PS47) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS39 I/O check, sensor check PFTDB CN2-12 (ON) 5-P 3 PS47 I/O check, sensor check PFTDB CN28-3 (ON) 6-P 4 M4 operation check MFPB CN12E-17 to 20 13-K 5 M30 operation check MFPB CN16E-4 (REM) MFPB CN16E-7 (LOCK) 10-K 6 M31 operation check PFTDB CN28-14 to 17 8-P 7 M33 operation check MFPB CN12E-13 to 16 13-K 8 SD1 operation check MFPB CN12E-11 (DRIVE) 13-K 9 PFTDB F10 conduction check – – 10 Replace PFTDB. – – 11 MFPB F13E or F14E conduction check – – 12 Replace MFPB.
- Code: 66-02, 66-12
- Description: Misfeed at DF paper feed section. 66-02 The after separate sensor (PS4) is not turned ON after a lapse of a given time after the take-up motor (M1) is turned ON. 66-12 A StreetPass communication occurs between the DF and the controller. – Paper jam of a sheet of paper left at the DF paper feed section results, if the after separate sensor (PS4) is turned ON when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
- Causes: • Take-up motor (M1) • After separate sensor (PS4) • DF control board (DFCB) • MFP board (MFPB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS4 I/O check, sensor check DFCB CN6-5 (ON) DF 7-J 3 M1 operation check DFCB CN3-1 to 4 DF 12-C 4 DFCB ICP2 or ICP10 conduction check. – – 5 Replace DFCB. – – 6 Replace MFPB.
- Code: 66-03, 66-13, 66-23, 66-33
- Description: Misfeed at DF transport section. 66-03 The after separate sensor (PS4) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper. 66-13 The registration sensor (PS5) is not turned ON even after the lapse of a given period of time after the paper has turned ON the after separate sensor (PS4). 66-23 The registration sensor (PS5) is not turned OFF even after the lapse of a given period of time after the paper has turned OFF the after separate sensor (PS4). 66-33 The before read sensor (PS6) is not turned ON after a lapse of a given time after a loop is formed and the registration motor (M2) is activated. – Paper jam of a sheet of paper left at the DF transfer section results, if the registration sensor (PS5) is turned ON when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
- Causes: • Registration motor (M2) • Take-up motor (M1) • Registration sensor (PS5) • After separate sensor (PS4) • Before read sensor (PS6) • DF control board (DFCB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS5 I/O check, sensor check DFCB CN6-17 (ON) DF 9-J 3 PS4 I/O check, sensor check DFCB CN6-5 (ON) DF11-C 4 PS6 I/O check, sensor check DFCB CN11-2 (ON) DF 1-C 5 M1 operation check DFCB CN3-1 to 4 DF 12-C 6 M2 operation check DFCB CN3-5 to 8 DF 11-C 7 DFCB ICP3 or ICP15 conduction check. – – 8 Replace DFCB.
- Code: 66-04, 66-14
- Description: Misfeed at DF paper exit section. 66-04 The paper exit sensor (PS7) is not turned ON (unblocked) even after the set period of time has elapsed after the before read sensor (PS6) is turned ON by the paper. 66-14 The paper exit sensor (PS7) is not turned OFF even after the lapse of a given period of time after the paper has turned OFF the before read sensor (PS6). – Paper jam of a sheet of paper left at the exit section results, if the paper exit sensor (PS7) is turned ON (unblocked) when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
- Causes: • Paper feed motor (M4) • Before read sensor (PS6) • Paper exit sensor (PS7) • DF control board (DFCB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS6 I/O check, sensor check DFCB CN11-3 (ON) DF 1-C 3 PS7 I/O check, sensor check DFCB CN13-3 (ON) DF 7-C 4 M4 operation check DFCB CN15-1 to 4 DF 11-C 5 DFCB ICP8 conduction check. – – 6 Replace DFCB.
- Code: 66-05, 66-06
- Description: Misfeed at DF image reading section. 66-05 The after separate sensor (PS6) is not turned OFF even after the lapse of a given period of time after the paper has turned OFF the registration sensor (PS6). 66-06 The before read sensor (PS6) is turned ON earlier than a given period of time after the paper has turned OFF the before read sensor (PS6) during original transportation. – Paper jam of a sheet of paper left at the DF image reading section results, if the before read sensor (PS6) is turned ON (unblocked) when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
- Causes: • Reading motor (M3) • Reading roller pressure/retraction motor (M6) • Registration sensor (PS5) • Before read sensor (PS6) • DF control board (DFCB)
- Troubleshooting Guides: 1 Initial check items – – 2 Make the adjustment of original stop position. – – 3 PS5 I/O check, sensor check DFCB CN6-17 (ON) DF 9-J 4 PS6 I/O check, sensor check DFCB CN11-3 (ON) DF 1-C 5 M3 operation check DFCB CN2-1 to 6 DF 12-C 6 M6 operation check DFCB CN4-1 to 2 DF 10-C 7 DFCB ICP1 or ICP16 conduction check. – – 8 Replace DFCB.
- Code: 66-08
- Description: Double feed detection jam. 66-08 Remained paper is found at the multi feed detection.
- Causes: • Multi feed detection board/1 (transmitter) (MFDB/1) • Multi feed detection board/2 (receiver) (MFDB/2) • Sensor control board (SCB) • DF control board (DFCB)
- Troubleshooting Guides: 1 Initial check items – – 2 Perform the Multi-Feed DetectionAdj. – – 3 Replace MFDB/1. – – 4 Replace MFDB/2. – – 5 Replace SCB. – – 6 DFCB ICP11 conduction check. – – 7 Replace DFCB.
- Code: 66-54
- Description: DF controller jam. The lift up lower sensor (PS3) is not blocked after a lapse of a given time after the last sheet of original is fed out.
- Causes: • Take-up motor (M1) • Registration motor (M2) • Reading motor (M3) • Paper feed motor (M4) • Reading roller pressure/retraction motor (M6) • After separate sensor (PS4) • Registration sensor (PS5) • Before read sensor (PS6) • Paper exit sensor (PS7) • DF control board (DFCB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS4 I/O check, sensor check DFCB CN6-5 (ON) DF 11-C 3 PS5 I/O check, sensor check DFCB CN6-17 (ON) DF 9-J 4 PS6 I/O check, sensor check DFCB CN11-3 (ON) DF 1-C 5 PS7 I/O check, sensor check DFCB CN13-3 (ON) DF 7-C 6 M1 operation check DFCB CN3-1 to 4 DF 12-C 7 M2 operation check DFCB CN3-5 to 8 DF 11-C 8 M3 operation check DFCB CN2-1 to 6 DF12-C 9 M4 operation check DFCB CN15-1 to 4 DF 11-C 10 M6 operation check DFCB CN4-1 to 2 DF 10-C 11 Replace DFCB.
- Code: 72-11
- Description: Misfeed at FS transport section. <When FS-537 or FS-537SD is installed> The FNS middle sensor (PS36) is not turned ON even after the set period of time has elapsed after the FNS entrance sensor (PS34) is turned ON by the paper.
- Causes: <When FS-537 or FS-537SD is installed> • FNS entrance sensor (PS34) • FNS middle sensor (PS36) • FS control board (FSCB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS34 I/O check, sensor check FSCB J8<A>-5 (ON) FS-537/FS-537SD 7-D 3 PS36 I/O check, sensor check FSCB J12<A>-10 (ON) FS-537/FS-537SD 16-D 4 Replace FSCB.
- Code: 72-14
- Description: Misfeed at FS transport section. <When FS-536 or FS-536SD is installed> The saddle exit sensor (PS5) is not turned ON even after the set period of time has elapsed after the main tray exit sensor (PS16) is turned ON by the paper. <When FS-537 or FS-537SD is installed> The SD discharge sensor (PS35) is not turned ON even after the set period of time has elapsed after the main tray exit sensor (PS37) is turned ON by the paper.
- Causes: <When FS-536 or FS-536SD is installed> • Saddle exit sensor (PS5) • Main tray exit sensor (PS16) • FS control board (FSCB) <When FS-537 or FS-537SD is installed> • SD discharge sensor (PS35) • Main tray exit sensor (PS37) • FS control board (FSCB)
- Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed: 1 Initial check items – – 2 PS5 I/O check, sensor check FSCB J5-2 (ON) FS-536/FS-536SD 16-K 3 PS16 I/O check, sensor check FSCB J9<B>-4 (ON) FS-536/FS-536SD 11-C 4 Replace FSCB.
(b) When FS-537 or FS-537SD is installed: 1 Initial check items – – 2 PS35 I/O check, sensor check FSCB J15-7 (ON) FS-537/FS-537SD 15 to 16-K to L 3 PS37 I/O check, sensor check FSCB J12<B>-14 (ON) FS-537/FS-537SD 18-D 4 Replace FSCB.
- Code: 72-15
- Description: Misfeed at FS transport section. <When FS-536 or FS-536SD is installed> The saddle exit sensor (PS5) is not turned OFF even after the set period of time has elapsed after it is turned ON. <When FS-537 or FS-537SD is installed> The SD discharge sensor (PS35) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper.
- Causes: <When FS-536 or FS-536SD is installed> • Saddle exit sensor (PS5) • FS control board (FSCB) <When FS-537 or FS-537SD is installed> • SD discharge sensor (PS35) • FS control board (FSCB)
- Troubleshooting Guides: When FS-536 or FS-536SD is installed: 1 Initial check items – – 2 PS5 I/O check, sensor check FSCB J5-2 (ON) FS-536/FS-536SD 16-K 3 Replace FSCB.
When FS-537 or FS-537SD is installed: 1 Initial check items – – 2 PS35 I/O check, sensor check FSCB J15-7 (ON) FS-537/FS-537SD 15 to 16-K to L 3 Replace FSCB.
- Code: 72-16
- Description: Misfeed at FS transport section. <When FS-536 or FS-536SD is installed> The FNS entrance sensor (PS4) is not turned ON even after the set period of time has elapsed after the RU transport sensor (PS60) is turned ON (blocked) by the paper. <When FS-537 or FS-537SD is installed> The FNS entrance sensor (PS34) is not turned ON even after the set period of time has elapsed after the RU transport sensor (PS60) is turned ON (blocked) by the paper.
- Causes: <When FS-536 or FS-536SD is installed> • RU transport sensor (PS60) • FNS entrance sensor (PS4) • FS control board (FSCB) <When FS-537 or FS-537SD is installed> • RU transport sensor (PS60) • FNS entrance sensor (PS34) • FS control board (FSCB)
- Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed: 1 Initial check items – – 2 PS60 I/O check, sensor check FSCB J6-7 (ON) FS-536/FS-536SD 12-K 3 PS4 I/O check, sensor check FSCB J4<B>-9 (ON) FS-536/FS-536SD 15-C 4 Replace FSCB.
(b) When FS-537 or FS-537SD is installed: 1 Initial check items – – 2 PS60 I/O check, sensor check FSCB J8<B>-11 (ON) FS-536/FS-536SD 12-K 3 PS34 I/O check, sensor check FSCB J8<A>-5 (ON) FS-536/FS-536SD 15-C 4 Replace FSCB.
- Code: 72-17
- Description: Misfeed at FS transport section. <When FS-536 or FS-536SD is installed> The FNS entrance sensor (PS4) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper. <When FS-537 or FS-537SD is installed> The FNS entrance sensor (PS34) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper.
- Causes: <When FS-536 or FS-536SD is installed> • FNS entrance sensor (PS4) • FS control board (FSCB) <When FS-537 or FS-537SD is installed> • FNS entrance sensor (PS34) • FS control board (FSCB)
- Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed: 1 Initial check items – – 2 PS4 I/O check, sensor check FSCB J4<B>-9 (ON) FS-536/FS-536SD 15-C 3 Replace FSCB.
(b) When FS-537 or FS-537SD is installed: 1 Initial check items – – 2 PS34 I/O check, sensor check FSCB J8<A>-5 (ON) FS-537/FS-537SD 7-D 3 Replace FSCB.
- Code: 72-18
- Description: Misfeed at FS transport section. <When FS-536 or FS-536SD is installed> • The main tray exit sensor (PS16) is not turned ON even after the set period of time has elapsed after the FNS entrance sensor (PS4) is turned ON by the paper. • While the buffer is controlled, the main tray exit sensor (PS16) is not tuned ON even after the set period of time has elapsed after the reverse rotation drive is started. <When FS-537 or FS-537SD is installed> The Main tray exit sensor (PS37) is not turned ON even after the set period of time has elapsed after the FNS middle sensor (PS36) is turned ON by the paper.
- Causes: <When FS-536 or FS-536SD is installed> • FNS entrance sensor (PS4) • Main tray exit sensor (PS16) • FS control board (FSCB) <When FS-537 or FS-537SD is installed> • FNS middle sensor (PS36) • Main tray exit sensor (PS37) • FS control board (FSCB)
- Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed: 1 Initial check items – – 2 PS4 I/O check, sensor check FSCB J4<B>-9 (ON) FS-536/FS-536SD 15-C 3 PS16 I/O check, sensor check FSCB J9<B>-4 (ON) FS-536/FS-536SD 11-C 4 Replace FSCB.
(b) When FS-537 or FS-537SD is installed: 1 Initial check items – – 2 PS36 I/O check, sensor check FSCB J12<A>-10 (ON) FS-537/FS-537SD 16-D 3 PS37 I/O check, sensor check FSCB J12<B>-14 (ON) FS-537/FS-537SD 18-D 4 Replace FSCB.
- Code: 72-19
- Description: Misfeed at FS transport section. <When FS-536 or FS-536SD is installed> The main tray exit sensor (PS16) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper. <When FS-537 or FS-537SD is installed> The main tray exit sensor (PS37) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper.
- Causes: <When FS-536 or FS-536SD is installed> • Main tray exit sensor (PS16) • FS control board (FSCB) <When FS-537 or FS-537SD is installed> • Main tray exit sensor (PS37) • FS control board (FSCB)
- Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed: 1 Initial check items – – 2 PS16 I/O check, sensor check FSCB J9<B>-4 (ON) FS-536/FS-536SD 10-K 3 Replace FSCB.
(b) When FS-537 or FS-537SD is installed: 1 Initial check items – – 2 PS37 I/O check, sensor check FSCB J12<B>-14 (ON) FS-537/FS-537SD 18-D 3 Replace FSCB.
- Code: 72-21
- Description: Misfeed at FS transport section. <When FS-536 or FS-536SD is installed> The staple stacker paper detection sensor (PS31) is not turn OFF even after the set period of time has elapsed after the start of exiting paper. <When FS-537 or FS-537SD is installed> The alignment plate paper detection sensor (PS32) is not turn OFF even after the set period of time has elapsed after the start of exiting paper.
- Causes: <When FS-536 or FS-536SD is installed> • Staple stacker paper detection sensor (PS31) • FS control board (FSCB) <When FS-537 or FS-537SD is installed> • Alignment plate paper detection sensor (PS32) • FS control board (FSCB)
- Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed: 1 Initial check items – – 2 PS31 I/O check, sensor check FSCB J12-11 (ON) FS-536/FS-536SD 6-C 3 Replace FSCB.
(b) When FS-537 or FS-537SD is installed: 1 Initial check items – – 2 PS32 I/O check, sensor check FSCB J21-12 (ON) FS-537/FS-537SD 5-D 3 Replace FSCB.
- Code: 72-22
- Description: Misfeed at FS transport section. <When FS-536 or FS-536SD is installed> The sub tray exit sensor (PS8) is not turned ON (blocked) even after the set period of time has elapsed after the paper reaches the paper transport acceleration point. <When FS-537 or FS-537SD is installed> The sub tray exit sensor (PS24) is not turned ON (blocked) even after the set period of time has elapsed after the paper reaches the paper transport acceleration point.
- Causes: <When FS-536 or FS-536SD is installed> • Sub tray exit sensor (PS8) • FS control board (FSCB) <When FS-537 or FS-537SD is installed> • Sub tray exit sensor (PS24) • FS control board (FSCB)
- Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed: 1 Initial check items – – 2 PS8 I/O check, sensor check FSCB J9<B>-8 (ON) FS-536/FS-536SD 11-C 3 Replace FSCB.
(b) When FS-537 or FS-537SD is installed: 1 Initial check items – – 2 PS24 I/O check, sensor check FSCB J15-3 (ON) FS-537/FS-537SD 16-K to L 3 Replace FSCB.
- Code: 72-23
- Description: Misfeed at FS transport section. <When FS-536 or FS-536SD is installed> The sub tray exit sensor (PS8) is not turned OFF (unblocked) even after the set period of time has elapsed after PS8 turns ON (block). <When FS-537 or FS-537SD is installed> The sub tray exit sensor (PS24) is not turned OFF (unblocked) even after the set period of time has elapsed after PS24 turns ON (block).
- Causes: <When FS-536 or FS-536SD is installed> • Sub tray exit sensor (PS8) • FNS entrance sensor (PS4) • Main tray exit sensor (PS16) • FS control board (FSCB) <When FS-537 or FS-537SD is installed> • Sub tray exit sensor (PS24) • FNS entrance sensor (PS34) • FNS middle sensor (PS36) • Main tray exit sensor (PS37) • FS control board (FSCB)
- Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed: 1 Initial check items – – 2 Clean the sensor of paper path. – – 3 PS8 I/O check, sensor check FSCB J9<B>-8 (ON) FS-536/FS-536SD 11-C 4 Replace FSCB.
(b) When FS-537 or FS-537SD is installed: 1 Initial check items – – 2 Clean the sensor of paper path. – – 3 PS24 I/O check, sensor check FSCB J15-3 (ON) FS-537/FS-537SD 16-K to L 4 Replace FSCB.
- Code: 72-25, 72-26
- Description: Misfeed at SD paper exit section. 72-25 <When FS-536SD or FS-537SD is installed> The fold exit sensor (PS12) is not turned ON by the paper even after the set period of time has elapsed after the half-fold exit operation started. 72-26 <When FS-536SD or FS-537SD is installed> The fold exit sensor (PS12) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper.
- Causes: <When FS-536SD or FS-537SD is installed> • Fold exit sensor (PS12) • SD control board (SDCB) • FS control board (FSCB)
- Troubleshooting Guides: When FS-536SD or FS-537SD is installed: 1 Initial check items – – 2 PS12 I/O check, sensor check SDCB J9-2 (ON) FS-536/FS-536SD 5-P FS-537/FS-537SD 4-P 3 Replace SDCB. (FS-536SD/FS-537SD) – – 4 Replace FSCB. (FS-536SD/FS-537SD)
- Code: 72-31, 72-34
- Description: Misfeed at JS exit section. 72-31 <When FS-537+JS-602 or FS-537SD+JS-602 is installed> The job tray paper exit sensor (PS402) is not turned ON (unblocked) even after the set period of time has elapsed after the route change gate home sensor (PS21) turns OFF (unblock) by the paper. 72-34 <When FS-537+JS-602 or FS-537SD+JS-602 is installed> The job tray paper exit sensor (PS402) is not turned OFF (unblocked) even after the set period of time has elapsed after PS402 turns ON (block) by a paper.
- Causes: <When FS-537+JS-602 or FS-537SD +JS-602 is installed> • Job tray paper exit sensor (PS402) • FS control board (FSCB)
- Troubleshooting Guides: When FS-537+JS-602 or FS-537SD+JS-602 is installed: 1 Initial check items – – 2 PS402 I/O check, sensor check FSCB J10-6 (ON) FS-537/FS-537SD 9-M 3 Replace FSCB.
- Code: 72-35
- Description: Misfeed at PI section. <When FS-537+PI-507 or FS-537SD+PI-507 is installed> • When a paper is fed from the upper tray, the paper entrance sensor /Lw (PS206) is not turned ON (unblocked) even after the set period of time has elapsed after the transfer clutch /Up (CL201) turns ON by a paper. • When a paper is fed from the lower tray, The paper entrance sensor /Lw (PS206) is not turned ON (unblocked) even after the set period of time has elapsed after the transfer clutch /Lw (CL202) turns ON by a paper.
- Causes: <When FS-537+PI-507 or FS-537SD +PI-507 is installed> • Transfer clutch /Up (CL201) • Transfer clutch /Lw (CL202) • Paper entrance sensor /Lw (PS206) • PI drive board (PIDB) • FS control board (FSCB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS206 I/O check, sensor check PIDB CN53<A>-5 (ON) PI-507 10-C 3 CL201 operation check PIDB CN54-3 (ON) PI-507 6-C 4 CL202 operation check PIDB CN56-1 (ON) PI-507 9-C 5 PIDB ICP4 conduction check. – – 6 Replace PIDB. – – 7 Replace FSCB.
- Code: 72-40, 72-41
- Description: Misfeed at ZU section. 72-40 <When FS-537+ZU-609 or FS-537SD+ZU-609 is installed> The FNS middle sensor (PS36) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper. 71-41 <When FS-537+ZU-609 or FS-537SD+ZU-609 is installed> When the second fold is started in Z-fold mode, the FNS middle sensor (PS36) is not switched from ON to OFF by the paper after the set period of time has elapsed.
- Causes: <When FS-537+ZU-609 or FS-537SD +ZU-609 is installed> • ZU transport motor (M500) • Folding guide motor (M501) • FNS middle sensor (PS36) • ZU drive board (ZUDB) • FS control board (FSCB)
- Troubleshooting Guides: When FS-537+ZU-609 or FS-537SD+ZU-609 is installed: 1 Initial check items – – 2 PS36 I/O check, sensor check FSCB J12<A>-10 (ON) FS-537/FS-537SD 16-D 3 M500 operation check ZUDB CN6-1 to 6 ZU-609 1 to 2-B 4 M501 operation check ZUDB CN6-9 to 12 ZU-609 2-B 5 ZUDB ICP1 or ICP2 conduction check. – – 6 Replace ZUDB. – – 7 Replace FSCB.
- Code: 72-43
- Description: Misfeed at PK JAM. <When FS-536+PK-520 or FS-536SD+PK-520 is installed> The punch position sensor (PS2) is not turned ON (unblocked) after a lapse of a given time after the punch drive motor (M1) starts rotating. <When FS-537+PK-523 or FS-537SD+PK-523 is installed> The punch position sensor (PS301) is not turned ON (unblocked) after a lapse of a given time after the punch drive motor (M301) starts rotating. – <When FS-537+PK-523 or FS-537SD+PK-523 is installed> Paper jam of a sheet of paper left at the PK section results, when the main power switch is turned ON, and the paper is detected by the paper size detect board (PSDTB).
- Causes: <When FS-536+PK-520 or FS-536SD +PK-520 is installed> • Punch drive motor (M1) • Punch position sensor (PS2) • FS control board (FSCB) <When FS-537+PK-523 or FS-537SD +PK-523 is installed> • Punch drive motor (M301) • PK punch home sensor/1 (PS301) • Punch control board (PKCB) • FS control board (FSCB) Residual paper jam • Paper size detect board (PSDTB) • FS control board (FSCB)
- Troubleshooting Guides: (a) When FS-536+PK-520 or FS-536SD+PK-520 is installed: 1 Initial check items – – 2 PS2 I/O check, sensor check FSCB J7-2 (ON) FS-536/FS-536SD (PK-520) 13-K 3 M1 operation check FSCB J7-7 to 8 FS-536/FS-536SD (PK-520) 13-K 4 Replace FSCB.
(b) When FS-537+PK-523 or FS-537SD+PK-523 is installed: 1 Initial check items – – 2 PS301 I/O check, sensor check PKCB CN36-5 (ON) PK-523 3-C 3 M301 operation check PKCB CN35-1 to 3 PK-523 2-C 4 Replace PKCB. – – 5 Replace FSCB.
(c) Residual paper jam (When FS-537+PK-523 or FS-537SD+PK-523 is installed): 1 Initial check items – – 2 Adjust the sensitivity (light intensity) by selecting [Finisher] -> [FS-FN adjustment] -> [Punch F. Sensor Intensity Adj.]. After adjustment, open and then close the front door, and check if the residual paper jam indication disappears. To turn off the main power switch, wait for more than 10 seconds until the residual paper jam indication disappears. – – 3 Replace PSDTB. 4 Replace FSCB.
- Code: 72-49
- Description: Misfeed at PI section. <When FS-537+PI-507 or FS-537SD+PI-507 is installed> The paper entrance sensor /Up (PS201) is not turned ON (unblocked) after a lapse of a given time after the transfer clutch /Up is turned ON.
- Causes: <When FS-537+PI-507 or FS-537SD +PI-507 is installed> • Transfer clutch /Up (CL201) • Paper entrance sensor /Up (PS201) • PI drive board (PIDB) • FS control board (FSCB)
- Troubleshooting Guides: When FS-537+PI-507 or FS-537SD+PI-507 is installed: 1 Initial check items – – 2 PS201 I/O check, sensor check PIDB CN53<A>-2 (ON) PI-507 10-C 3 CL201 operation check PIDB CN54-3 (ON) PI-507 10-C 4 PIDB ICP4 conduction check. – – 5 Replace PIDB. – – 6 Replace FSCB.
- Code: 72-50
- Description: Misfeed at PI section. <When FS-537+PI-507 or FS-537SD+PI-507 is installed> The FNS entrance sensor (PS34) is not turned ON even after the set period of time has elapsed after the paper entrance sensor /Up (PS201) turns ON (unblock) by a paper.
- Causes: <When FS-537+PI-507 or FS-537SD +PI-507 is installed> • Paper entrance sensor /Up (PS201) • FNS entrance sensor (PS34) • PI drive board (PIDB) • FS control board (FSCB)
- Troubleshooting Guides: When FS-537+PI-507 or FS-537SD+PI-507 is installed: 1 Initial check items – – 2 PS201 I/O check, sensor check PIDB CN53<A>-2 (ON) PI-507 10-C 3 PS34 I/O check, sensor check FSCB J8<A>-5 (ON) FS-537/FS-537SD 7-D 4 PIDB ICP4 conduction check. – – 5 Replace PIDB. – – 6 Replace FSCB.
- Code: 72-51
- Description: Misfeed at PI section. <When FS-537+PI-507 or FS-537SD+PI-507 is installed> The FNS entrance sensor (PS34) is not turned ON even after the set period of time has elapsed after the paper entrance sensor /Lw (PS206) is turned ON by the paper.
- Causes: <When FS-537+PI-507 or FS-537SD +PI-507 is installed> • Paper entrance sensor /Lw (PS206) • FNS entrance sensor (PS34) • PI drive board (PIDB) • FS control board (FSCB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS206 I/O check, sensor check PIDB CN53<A>-5 (ON) PI-507 10-C 3 PS34 I/O check, sensor check FSCB J8<A>-5 (ON) FS-537/FS-537SD 7-D 4 PIDB ICP4 conduction check. – – 5 Replace PIDB. – – 6 Replace FSCB.
- Code: 72-81
- Description: Misfeed at FS staple section. <When FS-536 or FS-536SD is installed> The stapler position sensor (center) (PS24) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed after the side stapler movement motor (M13) turned ON. <When FS-537 or FS-537SD is installed> The stapler position sensor (center) (PS20) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed after the stapler movement motor (M19) turned ON.
- Causes: <When FS-536 or FS-536SD is installed> • Side stapler movement motor (M13) • Stapler position sensor (center) (PS24) • FS control board (FSCB) <When FS-537 or FS-537SD is installed> • Stapler movement motor (M19) • Stapler position sensor (center) (PS20) • FS control board (FSCB)
- Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed: 1 Initial check items – – 2 M13 operation check FSCB J11<A>-1 to 4 FS-536/FS-536SD 4-C 3 PS24 I/O check, sensor check FSCB J11<B>-6 (ON) FS-536/FS-536SD 5-C 4 Replace FSCB.
(b) When FS-537 or FS-537SD is installed: 1 Initial check items – – 2 M19 operation check FSCB J17-10 to 13 FS-537/FS-537SD 14-D 3 PS20 I/O check, sensor check FSCB J16-5 (ON) FS-537/FS-537SD 15-D 4 Replace FSCB.
- Code: 72-84
- Description: Misfeed at SD staple section. <When FS-536SD or FS-537SD is installed> The stapler home position sensor/R does not turn ON even after the set period of time has elapsed after the staple operation started.
- Causes: <When FS-536SD or FS-537SD is installed> • Staple unit • SD control board (SDCB) • FS control board (FSCB)
- Troubleshooting Guides: 1 Initial check items – – 2 Replace the staple unit. (FS-536SD/FS-537SD) – – 3 Replace SDCB. (FS-536SD/FS-537SD) – – 4 Replace FSCB. (FS-536SD/FS-537SD)
- Code: 72-85
- Description: Misfeed at SD transport section. <When FS-536SD is installed> The SD entrance sensor (PS1) is not turned ON (blocked) even after the set period of time has elapsed after the saddle exit sensor (PS5) is turned ON by the paper. <When FS-537SD is installed> The SD entrance sensor (PS1) is not turned ON (blocked) even after the set period of time has elapsed after the SD discharge sensor (PS35) is turned ON by the paper.
- Causes: <When FS-536SD is installed> • SD entrance sensor (PS1) • Saddle exit sensor (PS5) • SD control board (SDCB) • FS control board (FSCB) <When FS-537SD is installed> • SD entrance sensor (PS1) • SD discharge sensor (PS35) • SD control board (SDCB) • FS control board (FSCB)
- Troubleshooting Guides: (a) When FS-536SD is installed: 1 Initial check items – – 2 PS5 I/O check, sensor check FSCB J5-2 (ON) FS-536/FS-536SD 16-K 3 PS1 I/O check, sensor check SDCB J4-8 (ON) FS-536/FS-536SD 5-L 4 Replace SDCB. – – 5 Replace FSCB.
(b) When FS-537SD is installed: 1 Initial check items – – 2 PS35 I/O check, sensor check FSCB J15-7 (ON) FS-537/FS-537SD 15 to 16-K to L 3 PS1 I/O check, sensor check SDCB J4-8 (ON) FS-537/FS-537SD 4-K 4 Replace SDCB. – – 5 Replace FSCB.
- Code: 72-86
- Description: Misfeed at SD transport section. <When FS-536SD or FS-537SD is installed> The SD entrance sensor (PS1) is not turned OFF (unblocked) even after the set period of time has elapsed after PS1 turns ON (block).
- Causes: <When FS-536SD or FS-537SD is installed> • SD entrance sensor (PS1) • SD control board (SDCB) • FS control board (FSCB)
- Troubleshooting Guides: (2) Procedure (a) When FS-536SD or FS-537SD is installed: 1 Initial check items – – 2 PS1 I/O check, sensor check SDCB J4-8 (ON) FS-536/FS-536SD 5-L FS-537/FS-537SD 4-K 3 Replace SDCB. (FS-536SD/FS-537SD) – – 4 Replace FSCB. (FS-536SD/FS-537SD)
- Code: 72-87
- Description: Misfeed at SD transport section. <When FS-536SD or FS-537SD is installed> The center staple/fold stacker paper detect sensor (PS3) is not turned ON even after the set period of time has elapsed after the SD entrance sensor (PS1) turns ON (block) by a paper.
- Causes: <When FS-536SD or FS-537SD is installed> • SD entrance sensor (PS1) • Center staple/fold stacker paper detect sensor (PS3) • SD control board (SDCB) • FS control board (FSCB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS1 I/O check, sensor check SDCB J4-3 (ON) FS-536/FS-536SD 4-K FS-537/FS-537SD 5-L 3 PS3 I/O check, sensor check SDCB J9-2 (ON) FS-536/FS-536SD 5-P FS-537/FS-537SD 5-P 4 Replace SDCB. (FS-536SD/FS-537SD) – – 5 Replace FSCB. (FS-536SD/FS-537SD)
- Code: 75-42
- Description: Misfeed at RU section. <When FS-536 or FS-536SD is installed> <When FS-537 or FS-537SD is installed> The RU transport sensor (PS60) is not turned ON (blocked) even after the set period of time has elapsed after the main body’s paper exit sensor (PS39) is turned ON (unblocked) by the paper.
- Causes: <When FS-536 or FS-536SD is installed> <When FS-537 or FS-537SD is installed> • Paper exit sensor (PS39) • RU transport sensor (PS60) • FS control board (FSCB)
- Troubleshooting Guides: (2) Procedure (a) When FS-536 or FS-536SD is installed: 1 Initial check items – – 2 PS39 I/O check, sensor check PFTDB CN2-12 (ON) 5-P 3 PS60 I/O check, sensor check FSCB J6-7 (ON) FS-536/FS-536SD 12-K 4 Replace FSCB.
(b) When FS-537 or FS-537SD is installed: 1 Initial check items – – 2 PS39 I/O check, sensor check PFTDB CN2-12 (ON) 5-P 3 PS60 I/O check, sensor check FSCB J8<B>-15 (ON) FS-537/FS-537SD 9-D 4 Replace FSCB.
Solve Konica-Minolta bizhub Pro 958 Error codes
- Code: 75-43
- Description: Misfeed at RU section. <When FS-536, FS-536SD, FS-537, or FS-537SD is installed> The RU transport sensor (PS60) is not turned OFF (unlocked) even after the set period of time has elapsed after it is turned ON (blocked).
- Causes: <When FS-536, FS-536SD, FS-537, or FS-537SD is installed> • RU transport sensor (PS60) • FS control board (FSCB)
- Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed: 1 Initial check items – – 2 PS60 I/O check, sensor check FSCB J6-7 (ON) FS-536/FS-536SD 12-K 3 Replace FSCB.
(b) When FS-537 or FS-537SD is installed: 1 Initial check items – – 2 PS60 I/O check, sensor check FSCB J8<B>-15 (ON) FS-537/FS-537SD 9-D 3 Replace FSCB.
- Code: 92-01, 92-02, 92-03, 92-40
- Description: Misfeed at duplex pre-registration section. 92-01 The leading edge of the paper is not turn ON (unblock) the registration sensor (PS38) even after the lapse of a given period of time after a duplex paper feed sequence has been started. 92-02 For the second-side feed of paper in the duplex mode, loop forming has not been complete before the second side of a sheet enters the registration roller because the rise timing of load to perform registration is earlier than the rise timing of load to form a loop. 92-03 The leading edge of the paper does not turn ON the OHP sensor (PS40) even after the lapse of a given period of time after a duplex paper feed sequence has been started. 92-40 For the second-side feed of paper in the duplex mode, the image write start signal permit continues to be disabled for a predetermined period of time after the timing of the image write start signal output.
- Causes: • ADU transport motor/1 (M31) • ADU transport motor/2 (M32) • Registration sensor (PS38) • OHP sensor (PS40) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS38 I/O check, sensor check PFTDB CN2-6 (ON) 4-P 3 PS40 I/O check, sensor check PFTDB CN2-3 (REM) 4-P 4 M31 operation check PFTDB CN28-14 to 17 8-P 5 M32 operation check PFTDB CN28-10 to 13 7-P 6 PFTDB F10 conduction check – – 7 Replace PFTDB. – – 8 Replace MFPB.
- Code: 93-10
- Description: Misfeed at duplex transport section. The ADU paper passage sensor/2 (PS48) is not turned ON (unblocked) even after the set period of time has elapsed after the ADU paper passage sensor/1 (PS47) turns ON (block) by the paper. – Paper jam of a sheet of paper left at the duplex transport section results, if the ADU paper passage sensor/1 (PS47) is turned ON (blocked) or the ADU paper passage sensor/2 (PS48) is turned ON (unblocked) when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset. – When the main power switch is turned ON, residual paper detection starts between each sensor. Paper jam of a sheet of paper left at the duplex transport section results, if the the ADU paper passage sensor/1 (PS47) is turned from OFF (unblocked) to ON (blocked). – When the main power switch is turned ON, residual paper detection starts between each sensor. Paper jam of a sheet of paper left at the duplex transport section results, if the ADU paper passage sensor/2 (PS48) is turned from OFF (blocked) to ON (unblocked).
- Causes: • ADU transport motor/1 (M31) • ADU transport motor/2 (M32) • ADU paper passage sensor/1 (PS47) • ADU paper passage sensor/2 (PS48) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1 Initial check items – – 2 PS47 I/O check, sensor check PFTDB CN28-3 (ON) 7-P 3 PS48 I/O check, sensor check PFTDB CN28-6 (ON) 6-P 4 M31 operation check PFTDB CN28-14 to 17 8-P 5 M32 operation check PFTDB CN28-10 to 13 7-P 6 PFTDB F10 conduction check – – 7 Replace PFTDB. – – 8 Replace MFPB.
- Code: 99-01
- Description: Controller JAM (paper size error). • As a result of a paper size error, the controller transmits a forced stop command to the printer engine and the printer engine is internally processing the size error. • As a result of a paper size error, the controller transmits a forced stop command to the printer engine; but the paper causing the size error cannot be fed out.
- Causes:
- Troubleshooting Guides: 1 Initial check items – – 2 Open and close the front door of the main body.
- Code: 99-02
- Description: Controller JAM (controller forced stop command). The controller transmits a forced stop command under a condition other than a paper size error during a print cycle.
- Causes:
- Troubleshooting Guides: 1 Initial check items – – 2 Open and close the front door of the main body.
- Code: 99-03
- Description: Controller JAM (image processing). Image stabilization not completing a job.
- Causes:
- Troubleshooting Guides: 1 Initial check items – – 2 Open and close the front door of the main body.
- Code: 99-04
- Description: Controller JAM (a job reservation in the main body is not released). A job reservation is not released after a lapse of a given time after that a print start command has been received.
- Causes:
- Troubleshooting Guides: 1 Initial check items – – 2 Open and close the front door of the main body.
- Code: 99-05
- Description: Controller JAM (main body not starting a job). A waiting status is not released even with a print start command received.
- Causes:
- Troubleshooting Guides: 1 Initial check items – – 2 Open and close the front door of the main body.
- Code: 99-06
- Description: Controller JAM (print control on the main body is not completed). Print control is not completed even after a job has been completed.
- Causes:
- Troubleshooting Guides: 1 Initial check items – – 2 Open and close the front door of the main body.
- Code: 99-07
- Description: Controller JAM (main body not completing a job). The engine does not stop after a lapse of a given time after that a print has finished.
- Causes:
- Troubleshooting Guides: 1 Initial check items – – 2 Open and close the front door of the main body.
- Code: 99-08
- Description: Controller JAM (finisher not starting a job). The finisher does not accept a print start command.
- Causes:
- Troubleshooting Guides: 1 Initial check items – – 2 Open and close the front door of the main body. Or, open and close the front door of the finisher.
- Code: 99-09
- Description: Controller JAM (finisher not completing a job). • A paper exit or paper finishing process inside the finisher is not completed. • The finisher does not start during a reset procedure from the jam.
- Causes:
- Troubleshooting Guides: 1 Initial check items – – 2 Open and close the front door of the main body. Or, open and close the front door of the finisher.
- Code: C0002
- Description: Paper feed communication error. When the paper feed/transport drive board (PFTDB) is receiving data, a communication error is detected.
- Causes: • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Correct the harness connection between MFPB CN7E-PFTDB CN4 if faulty. 3. Rewrite the firmware. 4. PFTDB F3 conduction check 5. Replace PFTDB. 6. MFPB F2E conduction check 7. Replace MFPB.
- Code: C0104, C0105
- Description: • C0104: Tray 3/4 feeder transportation motor’s failure to turn • C0105: Tray 3/4 feeder transportation motor’s turning at abnormal timing. C0104: The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. C0105: The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary
- Causes: • LCC transport motor (M25) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between M25-PFTDB CN13 for proper connection and correct as necessary. 2. Check the connector of M25 for proper drive coupling and correct as necessary. 3. M25 operation check • Control signal: PFTDB CN13-1 to 7 • Location of electrical component: 11-X 4. Replace M25. 5. PFTDB F15 conduction check 6. Replace PFTDB. 7. Replace MFPB.
- Code: C0202
- Description: Tray 1 feeder up/down abnormality. The tray 1 upper limit sensor (PS6) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
- Causes: • Tray 1 upper limit sensor (PS6) • Tray 1 lift-up motor (M6) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Remove the tray and check to see if a piece of paper is not left inside the machine. 2. Check the connector between M6-PFTDB CN25 for proper connection and correct as necessary. 3. Check the connector of M6 for proper drive coupling and correct as necessary. 4. Check the connector between PS6-relay CN145-PFTDB CN14 for proper connection and correct as necessary. 5. PS6 I/O check, sensor check • Control signal: PFTDB CN14-3 (ON) • Location of electrical component: 1-P 6. M6 operation check • Control signal: PFTDB CN25-10 to 11 • Location of electrical component: 2-X 7. Replace M6. 8. PFTDB F10 conduction check 9. Replace PFTDB. 10. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C0204
- Description: Tray 2 feeder up/down abnormality. The tray 2 upper limit sensor (PS14) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
- Causes: • Tray 2 upper limit sensor (PS14) • Tray 2 lift-up motor (M8) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Remove the tray and check to see if a piece of paper is not left inside the machine. 2. Check the connector between M8-PFTDB CN24 for proper connection and correct as necessary. 3. Check the connector of M8 for proper drive coupling and correct as necessary. 4. Check the connector between PS14-relay CN155B-PFTDB CN12 for proper connection and correct as necessary. 5. PS14 I/O check, sensor check. • Control signal: PFTDB CN12-17 (ON) • Location of electrical component: 4-P 6. M8 operation check • Control signal: PFTDB CN24-10 to 11 • Location of electrical component: 4-X 7. Replace M8. 8. PFTDB F10 conduction check 9. Replace PFTDB. 10. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C0206
- Description: Tray 3 feeder up/down abnormality. The tray 3 upper limit sensor (PS22) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
- Causes: • Tray 3 upper limit sensor (PS22) • Tray 3 lift-up motor (M23) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Remove the tray and check to see if a piece of paper is not left inside the machine. 2. Check the connector between M23-PFTDB CN15 for proper connection and correct as necessary. 3. Check the connector of M23 for proper drive coupling and correct as necessary. 4. Check the connector between PS22-relay CN193-relay CN113B-PFTDB CN17 for proper connection and correct as necessary. 5. PS22 I/O check, sensor check • Control signal: PFTDB CN17-6 (ON) • Location of electrical component: 6-X 6. M23 operation check • Control signal: PFTDB CN15-3 to 4 • Location of electrical component: 9-X 7. Replace M23. 8. PFTDB F12 conduction check 9. Replace PFTDB. 10. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C0208
- Description: Tray 4 feeder up/down abnormality. The tray 4 upper limit sensor (PS27) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
- Causes: • Tray 4 upper limit sensor (PS27) • Tray 4 lift-up motor (M24) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Remove the tray and check to see if a piece of paper is not left inside the machine. 2. Check the connector between M24-PFTDB CN15 for proper connection and correct as necessary. 3. Check the connector of M24 for proper drive coupling and correct as necessary. 4. Check the connector between PS27-relay CN194-relay CN121B-PFTDB CN19 for proper connection and correct as necessary. 5. PS27 I/O check, sensor check • Control signal: PFTDB CN19-6 (ON) • Location of electrical component: 8-X 6. M24 operation check • Control signal: PFTDB CN15-1 to 2 • Location of electrical component: 9-X 7. Replace M24. 8. PFTDB F12 conduction check 9. Replace PFTDB. 10. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C0211
- Description: Manual feed up/down abnormality. • The bypass upper limit sensor (PS35) is not turned ON (blocked) even after the bypass lift-up motor (M26) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position. • The bypass lower limit sensor (PS36) is not turned ON (blocked) even after the bypass lift-up motor (M26) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position.
- Causes: • Bypass lift-up motor (M26) • Bypass upper limit sensor (PS35) • Bypass lower limit sensor (PS36) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between M26-relay CN195B-PFTDB CN9 for proper connection and correct as necessary. 2. Check the connector of M26 for proper drive coupling and correct as necessary. 3. Check the connector between PS35-relay CN195B-PFTDB CN9 for proper connection and correct as necessary. 4. Check the connector between PS36-relay CN180-relay CN195A-PFTDB CN3 for proper connection and correct as necessary. 5. PS35 I/O check, sensor check • Control signal: PFTDB CN9-12 (ON) • Location of electrical component: 12-P 6. PS36 operation check • Control signal: PFTDB CN3-13 (ON) • Location of electrical component: 11-P 7. M26 operation check • Control signal: PFTDB CN9-1 to 2 • Location of electrical component: 11 to 12-P 8. Replace M26. 9. PFTDB F17 conduction check 10. Replace PFTDB. 11. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C0216
- Description: LCT up/down abnormality (When LU-205 or LU-303 is installed). The LU upper limit sensor (PS2) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
- Causes: • LU upper limit sensor (PS2) • LU lift-up motor (M1) • LU drive board (LUDB)
- Troubleshooting Guides: 1. Check the connector between M1-LUDB CN3 for proper connection and correct as necessary. 2. Check the connector of M1 for proper drive coupling and correct as necessary. 3. Check the connector between PS2-relay CN406-LUDB CN5 for proper connection and correct as necessary. 4. PS2 I/O check, sensor check • Control signal: LUDB CN5-3 (ON) • Location of electrical component: LU-205/LU-303 4-G 5. M1 operation check • Control signal: LUDB CN3-4 (ON) • Location of electrical component: LU-205/LU-303 3-G 6. Replace M1. 7. Replace LUDB. (LU-205/LU-303) NOTICE • Link to the wiring diagram ( N.3.1 LU-205) • Link to the wiring diagram ( N.3.2 LU-303)
- Code: C0301
- Description: Suction fan’s failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
- Causes: • Suction fan (FM1) • Paper feed/transport drive board (PFTDB)
- Troubleshooting Guides: 1. Check the connector between FM1-relay CN278-relay CN300-relay CN271B-PFTDB CN8 for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM1 operation check • Control signal: PFTDB CN8-3 (REM), PFTDB CN8-5 (LOCK) • Location of electrical component: 6-P 4. Replace FM1. 5. PFTDB F2 conduction check 6. Replace PFTDB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C0351
- Description: Paper cooling fan/in’s failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
- Causes: • Paper cooling fan/in (FM12) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between FM12-relay CN325-MFPB CN27E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM12 operation check • Control signal: MFPB CN27E<B>-6 (LOCK) • Location of electrical component: 15-C 4. Replace FM12. 5. MFPB F6E conduction check 6. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C1003, C1013
- Description: • C1003: PK communication error (Finisher detection) • C1013: PK communication error (PK detection). <When FS-537+PK-523 or FS-537SD+PK-523 is installed> When a communication error is detected between the FS control board (FSCB) and the punch control board (PKCB).
- Causes: • Punch control board (PKCB) • FS control board (FSCB)
- Troubleshooting Guides: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace PKCB. 4. Replace FSCB.
- Code: C1004, C1014
- Description: C1004: Finisher communication error (Engine detection) C1014: Finisher communication error (Finisher detection)
<When FS-536, FS-536SD, FS-537, or FS-537SD is installed> When a communication error is detected between the MFP board (MFPB) and the FS control board (FSCB). - Causes: • FS control board (FSCB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace FSCB. (FS-536/FS-536SD/FS-537/FS-537SD) 4. PKCB ICP1 conduction check. 5. PIDB ICP1 conduction check. 6. Replace MFPB.
- Code: C1007, C1017
- Description: • C1007: PI communication error (Finisher detection) • C1017: PI communication error (PI detection)
<When FS-537+PI-507 or FS-537SD+PI-507 is installed> When a communication error is detected between the FS control board (FSCB) and the PI drive board (PIDB). - Causes: • PI drive board (PIDB) • FS control board (FSCB)
- Troubleshooting Guides: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace PIDB. 4. Replace FSCB.
- Code: C1081, C1082
- Description: • C1081: SD communication error (Finisher detection) • C1082: SD communication error (SD detection). <When FS-536SD or FS-537SD is installed> When a communication error is detected between the FS control board (FSCB) and the SD control board (SDCB).
- Causes: • SD control board (SDCB) • FS control board (FSCB)
- Troubleshooting Guides: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace SDCB. (FS-536/FS-536SD/FS-537/FS-537SD) 4. Replace FSCB. (FS-536/FS-536SD/FS-537/FS-537SD)
- Code: C1102
- Description: Main tray up/down motor’s drive malfunction.
<When FS-536 or FS-536SD is installed> • While the exit tray is being lifted, the main tray upper position sensor (PS26/PS27) is not turned ON (blocked) and the main tray upper position detect switch (SW2) is not turned ON, even after the main tray up/down motor (M11) turns by the set number of times. • While the exit tray is being lowered, the main tray full detection sensor (PS29) is not turned ON (blocked) after the set period of time has elapsed after the main tray up/down motor (M11) is turned ON.
<When FS-537 or FS-537SD is installed> • The main tray lift up detection sensor (PS16/PS17) is not turned ON (blocked) after the set period of time has elapsed after the main tray up/ down motor (M6) is turned ON. • The main tray full detection sensor (PS12) is not turned ON (blocked) after the set period of time has elapsed after the main tray up/down motor (M6) is turned ON. - Causes: <When FS-536 or FS-536SD is installed> • Main tray up/down motor (M11) • Main tray upper position sensor/R (PS26) • Main tray upper position sensor/F (PS27) • Main tray full detection sensor (PS29) • Main tray upper position detect switch (SW2) • FS control board (FSCB)
<When FS-537 or FS-537SD is installed> • Main tray up/down motor (M6) • Main tray lift up detection sensor/F (PS16) • Main tray lift up detection sensor/R (PS17) • Main tray full detection sensor (PS12) • FS control board (FSCB) - Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed 1. Check the connector between M11-FSCB J9 for proper connection and correct as necessary. 2. Check the connector of M11 for proper drive coupling, and correct as necessary. 3. Check the connector between PS26-relay CN1-FSCB J14 for proper connection and correct as necessary. 4. Check the connector between PS27-relay CN1-FSCB J14 for proper connection and correct as necessary. 5. Check the connector between PS29-relay CN2-FSCB J14 for proper connection and correct as necessary. 6. Check the connector between SW2-FSCB J10 for proper connection and correct as necessary. 7. PS26 I/O check, sensor check • Control signal: FSCB J14<A>-5 (ON) • Location of electrical component: FS-536/FS-536SD 2-C 8. PS27 I/O check, sensor check • Control signal: FSCB J14<B>-6 (ON) • Location of electrical component: FS-536/FS-536SD 3-C 9. PS29 I/O check, sensor check • Control signal: FSCB J14<A>-8 (ON) • Location of electrical component: FS-536/FS-536SD 4-C 10. SW2 operation check • Control signal: FSCB J10-1 to 2 • Location of electrical component: FS-536/FS-536SD 15-K 11. M11 operation check • Control signal: FSCB J9<A>-9 to 10 • Location of electrical component: FS-536/FS-536SD 12-C 12. Replace M11. 13. FSCB F2 conduction check 14. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD)
(b) When FS-537 or FS-537SD is installed 1. Check the connector between M6-FSCB J23 for proper connection and correct as necessary. 2. Check the connector of M6 for proper drive coupling and correct as necessary. 3. Check the connector between PS16-relay CN10<B>-FSCB J20 for proper connection and correct as necessary. 4. Check the connector between PS17-relay CN10<B>-FSCB J20 for proper connection and correct as necessary. 5. Check the connector between PS12-relay CN9-FSCB J19 for proper connection and correct as necessary. 6. PS16 I/O check, sensor check • Control signal: FSCB J20<B>-4 (ON) • Location of electrical component: FS-537/FS-537SD 11 to 12-D 7. PS17 I/O check, sensor check • Control signal: FSCB J20<B>-7 (ON) • Location of electrical component: FS-537/FS-537SD 12-D 8. PS12 I/O check, sensor check • Control signal: FSCB J19-7 (ON) • Location of electrical component: FS-537/FS-537SD 10-D 9. M6 operation check • Control signal: FSCB J23-1 to 11 • Location of electrical component: FS-537/FS-537SD 13-D 10. Replace M6. 11. FSCB F3 conduction check 12. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1103
- Description: Alignment motor/Front’s drive malfunction.
<When FS-536 or FS-536SD is installed> • The alignment plate/F home sensor (PS12) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. • The alignment plate/F home sensor (PS12) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor/Front (M7) is turned ON to return the plate to the home position. • The alignment plate/F does not reach the specified position within the set period of time.
<When FS-537 or FS-537SD is installed> • The alignment plate/F home sensor (PS9) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. • The alignment plate/F home sensor (PS9) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor/Front (M14) is turned ON to return the plate to the home position. • The alignment plate/F does not reach the specified position within the set period of time. - Causes: <When FS-536 or FS-536SD is installed> • Alignment motor/Front (M7) • Alignment plate/F home sensor (PS12) • FS control board (FSCB)
<When FS-537 or FS-537SD is installed> • Alignment motor/Front (M14) • Alignment plate/F home sensor (PS9) • FS control board (FSCB) - Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed 1. Check the connector between M7-FSCB J4 for proper connection and correct as necessary. 2. Check the connector of M7 for proper drive coupling and correct as necessary. 3. Check the connector between PS12-FSCB J4 for proper connection and correct as necessary. 4. PS12 I/O check, sensor check • Control signal: FSCB J4<B>-4 (ON) • Location of electrical component: FS-536/FS-536SD 15-C 5. M7 operation check • Control signal: FSCB J4<A>-5 to 8 • Location of electrical component: FS-536/FS-536SD 14-C 6. Replace M7. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD)
(b) When FS-537 or FS-537SD is installed 1. Check the connector between M14-relay CN5-FSCB J18 for proper connection and correct as necessary. 2. Check the connector of M14 for proper drive coupling and correct as necessary. 3. Check the connector between PS9-relay CN5-FSCB J18 for proper connection and correct as necessary. 4. PS9 I/O check, sensor check • Control signal: FSCB J18-10 (ON) • Location of electrical component: FS-537/FS-537SD 6-D 5. M14 operation check • Control signal: FSCB J18-1 to 4 • Location of electrical component: FS-537/FS-537SD 6-D 6. Replace M14. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1104
- Description: Stacker plate drive motor’s malfunction. <When FS-537 or FS-537SD is installed> The stacker plate home sensor (PS30) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the stacker plate drive motor (M3) is turned ON.
- Causes: • Stacker plate drive motor (M3) • Stacker plate home sensor (PS30) • FS control board (FSCB)
- Troubleshooting Guides: 1. Check the connector between M3-relay CN1<B>-FSCB J22 for proper connection and correct as necessary. 2. Check the connector of M3 for proper drive coupling and correct as necessary. 3. Check the connector between PS30-relay CN2-relay CN1<B>-FSCB J22 for proper connection and correct as necessary. 4. PS30 I/O check, sensor check • Control signal: FSCB J22<B>-10 (ON) • Location of electrical component: FS-537/FS-537SD 3-D 5. M3 operation check • Control signal: FSCB J22<B>1 to 2 • Location of electrical component: FS-537/FS-537SD 2-D 6. Replace M3. 7. Replace FSCB. NOTICE: • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1105
- Description: Bundle eject motor’s drive malfunction. <When FS-536 or FS-536SD is installed> • The gripper home position sensor (PS18) is not turned ON (unblocked) even after the set period of time has elapsed after the gripper position detection sensor (PS19) turns OFF (block). • The gripper position detection sensor (PS19) is not turned OFF (blocked) even after the set period of time has elapsed after PS19 turns ON (unblock). • The gripper position detection sensor (PS19) is not turned ON (unblocked) even after the set period of time has elapsed after the gripper home position sensor (PS18) turns OFF (block). • The gripper home position sensor (PS18) is not turned OFF (blocked) even after the set period of time has elapsed after the bundle eject motor (M10) is energized. • The gripper home position sensor (PS18) and the gripper position detection sensor (PS19) is turned ON (unblocked) at the same time.
<When FS-537 or FS-537SD is installed> The gripper home position sensor (PS3) is not turned OFF (blocked) or ON (unblocked) even after the set period of time has elapsed after the bundle eject motor (M1) is turned ON. - Causes: <When FS-536 or FS-536SD is installed> • Bundle eject motor (M10) • Gripper home position sensor (PS18) • Gripper position detection sensor (PS19) • FS control board (FSCB)
<When FS-537 or FS-537SD is installed> • Bundle eject motor (M1) • Gripper home position sensor (PS3) • FS control board (FSCB) - Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed 1. Check the connector between M10-relay CN7<A>-FSCB J13 for proper connection and correct as necessary. 2. Check the connector of M10 for proper drive coupling, and correct as necessary. 3. Check the connector between PS18-relay CN7<A>-FSCB J13 for proper connection and correct as necessary. 4. Check the connector between PS19-relay CN8<B>-FSCB J12 for proper connection and correct as necessary. 5. PS18 I/O check, sensor check • Control signal: FSCB J13-13 (ON) • Location of electrical component: FS-536/FS-536SD 8-C 6. PS19 I/O check, sensor check • Control signal: FSCB J12-3 (ON) • Location of electrical component: FS-536/FS-536SD 7-C 7. M10 operation check • Control signal: FSCB J13-1 to 2 • Location of electrical component: FS-536/FS-536SD 9-C 8. Replace M10. 9. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD)
(b) When FS-537 or FS-537SD is installed 1. Check the connector between M1-relay CN1<A>-FSCB J22 for proper connection and correct as necessary. 2. Check the connector of M1 for proper drive coupling and correct as necessary. 3. Check the connector between PS3-relay CN1<A>-FSCB J22 for proper connection and correct as necessary. 4. PS3 I/O check, sensor check • Control signal: FSCB J22<A>-13 (ON) • Location of electrical component: FS-537/FS-537SD 2-D 5. M1 operation check • Control signal: FSCB J22<A>-1 to 2 • Location of electrical component: FS-537/FS-537SD 1-D 6. Replace M1. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1106
- Description: Stapler movement motor’s malfunction.
<When FS-536 or FS-536SD is installed> • The stapler home position sensor (rear) (PS23) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the side stapler movement motor (M13) turned ON. • The stapler does not reach the specified position within the set period of time.
<When FS-537 or FS-537SD is installed> • The stapler home position sensor (PS18/PS19) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the stapler movement motor (M19) turned ON. • The stapler does not reach the specified position within the set period of time. - Causes: <When FS-536 or FS-536SD is installed> • Side stapler movement motor (M13) • Stapler home position sensor (rear) (PS23) • FS control board (FSCB)
<When FS-537 or FS-537SD is installed> • Stapler movement motor (M19) • Stapler home position sensor (corner) (PS18) • Stapler home position sensor (rear) (PS19) • FS control board (FSCB) - Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed 1. Check the connector between M13-relay CN3-FSCB J11 for proper connection, and correct as necessary. 2. Check the connector of M13 for proper drive coupling and correct as necessary. 3. Check the connector between PS23-relay CN3-FSCB J11 for proper connection, and correct as necessary. 4. PS23 I/O check, sensor check • Control signal: FSCB J11<B>-3 (ON) • Location of electrical component: FS-536/FS-536SD 4-C 5. M13 operation check • Control signal: FSCB J11<A>-1 to 4 • Location of electrical component: FS-536/FS-536SD 4-C 6. Replace M13. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD)
(b) When FS-537 or FS-537SD is installed 1. Check the connector between M19-FSCB J17 for proper connection and correct as necessary. 2. Check the connector of M19 for proper drive coupling and correct as necessary. 3. Check the connector between PS18-FSCB J16 for proper connection and correct as necessary. 4. Check the connector between PS19-FSCB J16 for proper connection and correct as necessary. 5. PS18 I/O check, sensor check • Control signal: FSCB J16-9 (ON) • Location of electrical component: FS-537/FS-537SD15-D 6. PS19 I/O check, sensor check • Control signal: FSCB J16-6 (ON) • Location of electrical component: FS-537/FS-537SD 15-D 7. M19 operation check • Control signal: FSCB J17-10 to 13 • Location of electrical component: FS-537/FS-537SD 14-D 8. Replace M19. 9. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1109
- Description: Stapler motor’s malfunction.
<When FS-536 or FS-536SD is installed> • The stapler home position sensor (rear) (PS23) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the stapler motor (M14) turned ON. • The stapler position sensor (center) (PS24) is turned ON (blocked), when the stapler motor (M14) is running.
<When FS-537 or FS-537SD is installed> • The stapler home position sensor (PS18/PS19) is not turned (unblocked) or ON (blocked) even after the set period of time has elapsed after the stapler movement motor (M5) turned ON. • The stapler position sensor (center) (PS20) is turned ON (blocked), when the stapler motor (M5) is running. - Causes: <When FS-536 or FS-536SD is installed> • Stapler unit • Stapler home position sensor (rear) (PS23) • Stapler position sensor (center) (PS24) • FS control board (FSCB)
<When FS-537 or FS-537SD is installed> • Stapler unit • Stapler home position sensor (corner) (PS18) • Stapler home position sensor (rear) (PS19) • Stapler position sensor (center) (PS20) • FS control board (FSCB) - Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed 1. Check the connector between the stapler unit-relay CN4-FSCB J11 for proper connection and correct as necessary. 2. Check the connector of the stapler unit for proper drive coupling and correct as necessary. 3. Check the connector between PS23-relay CN3-FSCB J11 for proper connection, and correct as necessary. 4. Check the connector between PS24-relay CN3-FSCB J11 for proper connection and correct as necessary. 5. PS23 I/O check, sensor check • Control signal: FSCB J11<B>-3 (ON) • Location of electrical component: FS-536/FS-536SD 4-C 6. PS24 I/O check, sensor check • Control signal: FSCB J11<B>-6 • Location of electrical component: FS-536/FS-536SD 5-C 7. Replace the stapler unit. 8. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD)
(b) When FS-537 or FS-537SD is installed 1. Check the connector between the stapler unit-FSCB J17 for proper connection and correct as necessary. 2. Check the connector of the stapler unit for proper drive coupling and correct as necessary. 3. Check the connector between PS18-FSCB J16 for proper connection and correct as necessary. 4. Check the connector between PS19-FSCB J16 for proper connection and correct as necessary. 5. Check the connector between PS20-FSCB J16 for proper connection and correct as necessary. 6. PS18 I/O check, sensor check • Control signal: FSCB J16-9 • Location of electrical component: FS-537/FS-537SD 15-D 7. PS19 I/O check, sensor check • Control signal: FSCB J16-6 • Location of electrical component: FS-537/FS-537SD 15-D 8. PS20 I/O check, sensor check • Control signal: FSCB J16-3 • Location of electrical component: FS-537/FS-537SD 15-D 9. Replace the stapler unit. 10. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1112
- Description: Stapler motor’s drive malfunction. <When FS-536SD or FS-537SD is installed> • The stapler home sensor is not turned ON even after the set period of time has elapsed while the stapler motor is energized. • The stapler home sensor is not turned OFF even after the set period of time has elapsed after the stapler home sensor is turned ON.
- Causes: <When FS-536SD or FS-537SD is installed> • Staple unit • SD control board (SDCB) • FS control board (FSCB)
- Troubleshooting Guides: 1. Check the connector between the staple unit-SDCB J4 for proper connection and correct as necessary. 2. Check the connector of the staple unit for proper drive coupling and correct as necessary. 3. Replace the staple unit. (FS-536SD/FS-537SD) 4. Replace SDCB. (FS-536SD/FS-537SD) 5. Replace FSCB. (FS-536SD/FS-537SD)
- Code: C1113
- Description: Stopper drive motor’s malfunction. <When FS-536SD or FS-537SD is installed> The stopper home sensor (PS6) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the stopper drive motor (M4) is turned ON.
- Causes: <When FS-536SD or FS-537SD is installed> • Stopper drive motor (M4) • Stopper home sensor (PS6) • SD control board (SDCB) • FS control board (FSCB)
- Troubleshooting Guides: 1. Check the connector between M4-SDCB J10 for proper connection and correct as necessary. 2. Check the connector of M4 for proper drive coupling and correct as necessary. 3. Check the connector between PS6-SDCB J10 for proper connection and correct as necessary. 4. PS6 I/O check, sensor check • Control signal: SDCB J10-5 (ON) • Location of electrical component: FS-536/FS-536SD 2-P, FS-537/FS-537SD 2-P 5. M4 operation check • Control signal: SDCB J10-6 to 9 • Location of electrical component: FS-536/FS-536SD 2-P, FS-537/FS-537SD 1-P 6. Replace M4. (FS-536SD/FS-537SD) 7. Replace SDCB. (FS-536SD/FS-537SD) 8. Replace FSCB. (FS-536SD/FS-537SD) NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD) • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1114
- Description: Alignment motor’s malfunction. <When FS-536SD or FS-537SD is installed> The alignment home sensor (PS4) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the alignment motor (M3) is turned ON.
- Causes: <When FS-536SD or FS-537SD is installed> • Alignment motor (M3) • Alignment home sensor (PS4) • SD control board (SDCB) • FS control board (FSCB)
- Troubleshooting Guides: 1. Check the connector between M3-relay CN26 (FS-536SD), CN29 (FS-537SD)-SDCB J7 for proper connection and correct as necessary. 2. Check the connector of M3 for proper drive coupling and correct as necessary. 3. Check the connector between PS4-relay CN26 (FS-536SD), CN29 (FS-537SD)-SDCB J7 for proper connection and correct as necessary. 4. PS4 I/O check, sensor check • Control signal: SDCB J7-6 (ON) • Location of electrical component: FS-536/FS-536SD 6-P, FS-537/FS-537SD 5-P 5. M3 operation check • Control signal: SDCB J7-7 to 10 • Location of electrical component: FS-536/FS-536SD 6-P, FS-537/FS-537SD 5-P 6. Replace M3. (FS-536SD/FS-537SD) 7. Replace SDCB. (FS-536SD/FS-537SD) 8. Replace FSCB. (FS-536SD/FS-537SD) NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD) • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1115
- Description: Center fold knife motor’s malfunction. <When FS-536SD or FS-537SD is installed> The center fold knife home sensor (PS8) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the center fold knife motor (M9) is turned ON.
- Causes: <When FS-536SD or FS-537SD is installed> • Center fold knife motor (M9) • Center fold knife home sensor (PS8) • SD control board (SDCB) • FS control board (FSCB)
- Troubleshooting Guides: 1. Check the connector between M9-SDCB J11 for proper connection and correct as necessary. 2. Check the connector of M9 for proper drive coupling and correct as necessary. 3. Check the connector between PS8-relay CN26 (FS-536SD), CN29 (FS-537SD)-SDCB J7 for proper connection and correct as necessary. 4. PS8 I/O check, sensor check • Control signal: SDCB J7-3 (ON) • Location of electrical component: FS-536/FS-536SD 7-P, FS-537/FS-537SD 6-P 5. M9 operation check • Control signal: SDCB J11-11 to 20 • Location of electrical component: FS-536/FS-536SD 2-L, FS-537/FS-537SD 1-K 6. Replace M9. (FS-536SD/FS-537SD) 7. Replace SDCB. (FS-536SD/FS-537SD) 8. Replace FSCB. (FS-536SD/FS-537SD) NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD) • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1124
- Description: Tray lift motor /Lw’s drive malfunction. <When FS-537+PI-507 or FS-537SD+PI-507 is installed> The tray upper limit sensor /Lw (PS209) or tray lower limit sensor /Lw (PS210) is not turned ON (blocked) after the set period of time has elapsed after the tray lift motor /Lw (M202) is turned ON.
- Causes: • Tray lift motor /Lw (M202) • Tray upper limit sensor /Lw (PS209) • Tray lower limit sensor /Lw (PS210) • PI drive board (PIDB) • FS control board (FSCB)
- Troubleshooting Guides: 1. Check the connector between M202-relay CN206-PIDB CN56 for proper connection and correct as necessary. 2. Check the connector of M202 for proper drive coupling and correct as necessary. 3. Check the connector between PS209-relay CN237-PIDB CN53 for proper connection and correct as necessary. 4. Check the connector between PS210-relay CN236-PIDB CN53 for proper connection and correct as necessary. 5. PS209 I/O check, sensor check • Control signal: PIDB CN53<A>-8 (ON) • Location of electrical component: PI-507 10-C 6. PS210 I/O check, sensor check • Control signal: PIDB CN53<A>-11 (ON) • Location of electrical component: PI-507 11-C 7. M202 operation check • Control signal: PIDB CN56-5 to 6 • Location of electrical component: PI-507 9-C 8. Replace M202. 9. Replace PIDB. 10. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.6 PI-507)
- Code: C1125
- Description: Tray lift motor /Up’s drive malfunction. <When FS-537+PI-507 or FS-537SD+PI-507 is installed> The tray upper limit sensor /Up (PS205) or tray lower limit sensor /Up (PS204) is not turned ON (blocked) after the set period of time has elapsed after the tray lift motor /Up (M201) is turned ON.
- Causes: • Tray lift motor /Up (M201) • Tray upper limit sensor /Up (PS204) • Tray lower limit sensor /Up(PS205) • PI drive board (PIDB) • FS control board (FSCB)
- Troubleshooting Guides: 1. Check the connector between M201-relay CN203-PIDB CN54 for proper connection and correct as necessary. 2. Check the connector of M201 for proper drive coupling and correct as necessary. 3. Check the connector between PS204-relay CN235-PIDB CN55 for proper connection and correct as necessary. 4. Check the connector between PS205-relay CN235-PIDB CN55 for proper connection and correct as necessary. 5. PS204 I/O check, sensor check • Control signal: PIDB CN55-8 (ON) • Location of electrical component: PI-507 8-C 6. PS205 I/O check, sensor check • Control signal: PIDB CN55-7 (ON) • Location of electrical component: PI-507 8-C 7. M201 operation check • Control signal: PIDB CN54-7 to 8 • Location of electrical component: PI-507 6 to 7-C 8. Replace M201. 9. Replace PIDB. 10. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.6 PI-507)
- Code: C1127
- Description: Punch oscillating motor’s drive malfunction. <When FS-537+PK-523 or FS-537SD+PK-523 is installed> The PKpunch oscillatinghome sensor (PS303) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed while the punch oscillating motor (M302) is energized.
- Causes: • Punch oscillating motor (M302) • PK punch oscillatinghome sensor (PS303) • Punch control board (PKCB) • FS control board (FSCB)
- Troubleshooting Guides: 1. Check the connector between M302-relay CN342-relay CN341-PKCB CN1 for proper connection and correct as necessary. 2. Check the connector of M302 for proper drive coupling and correct as necessary. 3. Check the connector between PS303-relay CN342-relay CN341-PKCB CN37 for proper connection and correct as necessary. 4. PS303 I/O check, sensor check • Control signal: PKCB CN37-2 (ON) • Location of electrical component: PK-523 5-C 5. M302 operation check • Control signal: PKCB CN1-1 to 6 • Location of electrical component: PK-523 5-C 6. Replace M302. 7. PKCB ICP2 conduction check. 8. Replace PKCB. 9. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.4 PK-523)
- Code: C1130
- Description: ZU transport motor’s malfunction. <When FS-537+ZU-609 or FS-537SD+ZU-609 is installed> The chopper home sensor (PS501) is not turned ON (blocked) even after the set period of time has elapsed after the ZU transport motor (M500) is turned ON.
- Causes: • ZU transport motor (M500) • Chopper home sensor (PS501) • ZU drive board (ZUDB)
- Troubleshooting Guides: 1. Check the connector between M500-ZUDB CN6 for proper connection and correct as necessary. 2. Check the connector of M500 for proper drive coupling and correct as necessary. 3. Check the connector between PS501-ZUDB CN5 for proper connection and correct as necessary. 4. PS501 I/O check, sensor check • Control signal: ZUDB CN5-9 (ON) • Location of electrical component: ZU-609 4-B 5. M500 operation check • Control signal: ZUDB CN6-1 to 6 • Location of electrical component: ZU-609 1 to 2-B 6. Replace M500. 7. Replace ZUDB. NOTICE • Link to the wiring diagram ( N.3.5 ZU-609)
- Code: C1131
- Description: Folding guide motor’s drive malfunction. <When FS-537+ZU-609 or FS-537SD+ZU-609 is installed> The guide home sensor (PS500) is not turned ON (blocked) even after the set period of time has elapsed after the folding guide motor (M501) is turned ON.
- Causes: • Folding guide motor (M501) • Guide home sensor (PS500) • ZU drive board (ZUDB)
- Troubleshooting Guides: 1. Check the connector between M501-ZUDB CN6 for proper connection and correct as necessary. 2. Check the connector of M501 for proper drive coupling and correct as necessary. 3. Check the connector between PS500-ZUDB CN5 for proper connection and correct as necessary. 4. PS500 I/O check, sensor check • Control signal: ZUDB CN5-3 (ON) • Location of electrical component: ZU-609 3-B 5. M501 operation check • Control signal: ZUDB CN6-9 to 12 • Location of electrical component: ZU-609 2-B 6. Replace M501. 7. Replace ZUDB. NOTICE • Link to the wiring diagram ( N.3.5 ZU-609)
- Code: C1132
- Description: Punch drive motor’s drive malfunction.
<When FS-536+PK-520 or FS-536SD+PK-520 is installed> The punch home sensor (PS1) is not turned ON (unblocked) or OFF (blocked) even after the set period of time has elapsed while the punch drive motor (M1) is energized.
<When FS-537+PK-523 or FS-537SD+PK-523 is installed> The PK punch home sensor/2(PS301) is not turned ON (unblocked) or OFF (blocked) even after the set period of time has elapsed while the punch drive motor (M301) is energized. - Causes: <When FS-536+PK-520 or FS-536SD+PK-520 is installed> • Punch drive motor (M1) • Punch home sensor (PS1) • FS control board (FSCB)
<When FS-537+PK-523 or FS-537SD+PK-523 is installed> • Punch drive motor (M301) • PK punch home sensor/2(PS301) • Punch control board (PKCB) • FS control board (FSCB) - Troubleshooting Guides: (a) When FS-536+PK-520 or FS-536SD+PK-520 is installed 1. Check the connector between M1-relay CN351-FSCB J7 for proper connection and correct as necessary. 2. Check the connector of M1 for proper drive coupling and correct as necessary. 3. Check the connector between PS1-FSCB J7 for proper connection and correct as necessary. 4. PS1 I/O check, sensor check • Control signal: FSCB J7-5 (ON) • Location of electrical component: FS-536/FS-536SD 13-K 5. M1 operation check • Control signal: FSCB J7-7 to 8 • Location of electrical component: FS-536/FS-536SD 13-K 6. Replace M1. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD)
(b) When FS-537+PK-523 or FS-537SD+PK-523 is installed 1. Check the connector between M301-relay CN351-PKCB CN35 for proper connection and correct as necessary. 2. Check the connector of M301 for proper drive coupling and correct as necessary. 3. Check the connector between PS301-PKCB CN36 for proper connection and correct as necessary. 4. PS301 I/O check, sensor check • Control signal: PKCB CN36-5 (ON) • Location of electrical component: PK-523 3-C 5. M301 operation check • Control signal: PKCB CN35-1 to 3 • Location of electrical component: PK-523 2-C 6. Replace M301. 7. Replace PKCB. 8. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.4 PK-523)
- Code: C1133
- Description: Pressure motor’s malfunction. <When FS-537+ZU-609 or FS-537SD+ZU-609 is installed> The press home sensor (PS502) is not turned ON (unblocked), or is not turned OFF (blocked) after it is turned ON (unblocked), even after the set period of time has elapsed after the pressure motor (M502) starts searching its home position
- Causes: • Pressure motor (M502) • Press home sensor (PS502) • ZU drive board (ZUDB)
- Troubleshooting Guides: 1. Check the connector between M502-ZUDB CN6 for proper connection and correct as necessary. 2. Check the connector of M502 for proper drive coupling and correct as necessary. 3. Check the connector between PS502-ZUDB CN5 for proper connection and correct as necessary. 4. PS502 I/O check, sensor check • Control signal: ZUDB CN5-6 (ON) • Location of electrical component: ZU-609 4-B 5. M502 operation check • Control signal: ZUDB CN6-7 (DRV) • Location of electrical component: ZU-609 2-B 6. Replace M502. 7. ZUDB ICP3 conduction check. 8. Replace ZUDB. NOTICE • Link to the wiring diagram ( N.3.5 ZU-609)
- Code: C1140
- Description: Alignment motor/rear’s malfunction.
<When FS-536 or FS-536SD is installed> The alignment plate/R home sensor (PS13) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed while the alignment motor/rear (M8) is energized.
<When FS-537 or FS-537SD is installed> The alignment plate/R home sensor (PS6) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed while the alignment motor/rear (M13) is energized. - Causes: <When FS-536 or FS-536SD is installed> • Alignment motor/rear (M8) • Alignment plate/R home sensor (PS13) • FS control board (FSCB)
<When FS-537 or FS-537SD is installed> • Alignment motor/rear (M13) • Alignment plate/R home sensor (PS6) • FS control board (FSCB) - Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed 1. Check the connector between M8-FSCB J12 for proper connection and correct as necessary. 2. Check the connector of M8 for proper drive coupling and correct as necessary. 3. Check the connector between PS13-FSCB J9 for proper connection and correct as necessary. 4. PS13 I/O check, sensor check • Control signal: FSCB J9<B>-11 (ON) • Location of electrical component: FS-536/FS-536SD 10-C 5. M8 operation check • Control signal: FSCB J12-13 to 16 (ON) • Location of electrical component: FS-536/FS-536SD 6-C 6. Replace M8. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD)
(b) When FS-537 or FS-537SD is installed 1. Check the connector between M13-relay CN3-FSCB J21 for proper connection and correct as necessary. 2. Check the connector of M13 for proper drive coupling and correct as necessary. 3. Check the connector between PS6-relay CN4-relay CN3-FSCB J21 for proper connection and correct as necessary. 4. PS6 I/O check, sensor check • Control signal: FSCB J21-10 (ON) • Location of electrical component: FS-537/FS-537SD 4-D 5. M13 operation check • Control signal: FSCB J21-1 to 4 • Location of electrical component: FS-537/FS-537SD 4-D 6. Replace M13. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1141
- Description: FNS paddle motor’s malfunction.
<When FS-536 or FS-536SD is installed> The upper paddle home position detection sensor (PS14) is not turned OFF (blocked) or ON (unblocked) even after the set period of time has elapsed while the FNS paddle motor (M5) is turning.
<When FS-537 or FS-537SD is installed> The paddle home sensor (PS25) is not turned OFF (blocked) or ON (unblocked) even after the set period of time has elapsed while the FNS paddle motor (M9) is turning. - Causes: <When FS-536 or FS-536SD is installed> • FNS paddle motor (M5) • Upper paddle home position detection sensor (PS14) • FS control board (FSCB)
<When FS-537 or FS-537SD is installed> • FNS paddle motor (M9) • Paddle home sensor (PS25) • FS control board (FSCB) - Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed 1. Check the connector between M5-FSCB J4 for proper connection and correct as necessary. 2. Check the connector of M5 for proper drive coupling and correct as necessary. 3. Check the connector between PS14-FSCB J4 for proper connection and correct as necessary. 4. PS14 I/O check, sensor check • Control signal: FSCB J4<B>-7 (ON) • Location of electrical component: FS-536/FS-536SD 15-C 5. M5 operation check • Control signal: FSCB J4<A>-9 to 12 • Location of electrical component: FS-536/FS-536SD 14-C 6. Replace M5. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD)
(b) When FS-537 or FS-537SD is installed 1. Check the connector between M9-relay CN13<B>-FSCB J14 for proper connection and correct as necessary. 2. Check the connector of M9 for proper drive coupling and correct as necessary. 3. Check the connector between PS25-relay CN13<B>-FSCB J14 for proper connection and correct as necessary. 4. PS25 I/O check, sensor check • Control signal: FSCB J14<B>-10 (ON) • Location of electrical component: FS-537/FS-537SD 16-K to L 5. M9 operation check • Control signal: FSCB J14<B>-4 to 7 • Location of electrical component: FS-537/FS-537SD 17- K to L 6. Replace M9. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1142
- Description: Paddle up/down motor’s drive malfunction. <When FS-537 or FS-537SD is installed> The paddle up/down home sensor (PS27) is not turned OFF (blocked) or ON (unblocked) even after the set period of time has elapsed while the paddle up/down motor (M7) is energized.
- Causes: • Paddle up/down motor (M7) • Paddle up/down home sensor (PS27) • FS control board (FSCB)
- Troubleshooting Guides: (2) Procedure 1. Check the connector between M7-relay CN13<A>-FSCB J14 for proper connection and correct as necessary. 2. Check the connector of M7 for proper drive coupling and correct as necessary. 3. Check the connector between PS27-relay CN13<A>-FSCB J14 for proper connection and correct as necessary. 4. PS27 I/O check, sensor check • Control signal: FSCB J14<A>-7 (ON) • Location of electrical component: FS-537/FS-537SD 18-K to L 5. M7 operation check • Control signal: FSCB J14<A>-1 to 4 • Location of electrical component: FS-537/FS-537SD 18-K to L 6. Replace M7. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1143
- Description: Arm drive motor’s drive malfunction. <When FS-537 or FS-537SD is installed> The arm home position sensor (PS26) is not turned ON (unblocked) or OFF (blocked) even after the set period of time has elapsed while the arm drive motor (M8) is energized.
- Causes: • Arm drive motor (M8) • Arm home position sensor (PS26) • FS control board (FSCB)
- Troubleshooting Guides: 1. Check the connector between M8-relay CN13<A>-FSCB J14 for proper connection and correct as necessary. 2. Check the connector of M8 for proper drive coupling and correct as necessary. 3. Check the connector between PS26-relay CN13<B>-FSCB J14 for proper connection and correct as necessary. 4. PS26 I/O check, sensor check • Control signal: FSCB J14<B>-3 (ON) • Location of electrical component: FS-537/FS-537SD 17-K to L 5. M8 operation check • Control signal: FSCB J14<A>-8 to 11 • Location of electrical component: FS-537/FS-537SD 17-K to L 6. Replace M8. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1144
- Description: Pre-eject drive motor’s drive malfunction.
<When FS-536 or FS-536SD is installed> • The pre-eject home sensor (PS21) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the preeject drive motor (M9) is turned ON. • The pre-eject away sensor (PS22) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed after the preeject drive motor (M9) is turned ON.
<When FS-537 or FS-537SD is installed> The trail edge stopper home sensor (PS31) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the pre-eject drive motor (M2) is turned ON. - Causes: <When FS-536 or FS-536SD is installed> • Pre-eject drive motor (M9) • Pre-eject home sensor (PS21) • Pre-eject away sensor (PS22) • FS control board (FSCB)
<When FS-537 or FS-537SD is installed> • Pre-eject drive motor (M2) • Trail edge stopper home sensor (PS31) • FS control board (FSCB) - Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed 1. Check the connector between M9-relay CN7<A>-FSCB J13 for proper connection, and correct as necessary. 2. Check the connector of M9 for proper drive coupling and correct as necessary. 3. Check the connector between PS21-relay CN8-relay CN7<B>-FSCB J12 for proper connection, and correct as necessary. 4. Check the connector between PS22-relay CN8-relay CN7<B>-FSCB J12 for proper connection, and correct as necessary. 5. PS21 I/O check, sensor check • Control signal: FSCB J12-6 (ON) • Location of electrical component: FS-536/FS-536SD 7-C 6. PS22 I/O check, sensor check • Control signal: FSCB J12-9 (ON) • Location of electrical component: FS-536/FS-536SD 7-C 7. M9 operation check • Control signal: FSCB J13-3 to 4 • Location of electrical component: FS-536/FS-536SD 9-C 8. Replace M9. 9. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD)
(b) When FS-537 or FS-537SD is installed 1. Check the connector between M2-relay CN1<A>-FSCB J22 for proper connection and correct as necessary. 2. Check the connector of M2 for proper drive coupling and correct as necessary. 3. Check the connector between PS31-relay CN2-relay CN1<B>-FSCB J22 for proper connection and correct as necessary. 4. PS31 I/O check, sensor check • Control signal: FSCB J22<B>-13 • Location of electrical component: FS-537/FS-537SD 3-D 5. M2 operation check • Control signal: FSCB J22<A>-3 to 4 • Location of electrical component: FS-537/FS-537SD 1-D 6. Replace M2. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1145
- Description: Trailing edge stopper motor malfunction.
<When FS-536 or FS-536SD is installed> The trailing edge stopper home position detection sensor (PS20) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the trailing edge stopper motor (M6) is turned ON.
<When FS-537 or FS-537SD is installed> The trailing edge stopper home position detection sensor/F (PS10) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the trailing edge stopper motor/F (M12) is turned ON. - Causes: <When FS-536 or FS-536SD is installed> • Trailing edge stopper motor (M6) • Trailing edge stopper home position detection sensor (PS20) • FS control board (FSCB)
<When FS-537 or FS-537SD is installed> • Trail edge stopper motor/F (M12) • Trail edge stopper sensor/F (PS10) • FS control board (FSCB) - Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed 1. Check the connector between M6-FSCB J5 for proper connection and correct as necessary. 2. Check the connector of M6 for proper drive coupling and correct as necessary. 3. Check the connector between PS20-relay CN19-FSCB J5 for proper connection and correct as necessary. 4. PS20 I/O check, sensor check • Control signal: FSCB J5-9 (ON) • Location of electrical component: FS-536/FS-536SD 15-K 5. M6 operation check • Control signal: FSCB J5-13 to 16 • Location of electrical component: FS-536/FS-536SD 15-K 6. Replace M6. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD)
(b) When FS-537 or FS-537SD is installed 1. Check the connector between M12-relay CN5-FSCB J18 for proper connection and correct as necessary. 2. Check the connector of M12 for proper drive coupling and correct as necessary. 3. Check the connector between PS10-relay CN5-FSCB J18 for proper connection and correct as necessary. 4. PS10 I/O check, sensor check • Control signal: FSCB J18-13 (ON) • Location of electrical component: FS-537/FS-537SD 6 to 7-D 5. M12 operation check • Control signal: FSCB J18-14 to 17 • Location of electrical component: FS-537/FS-537SD 7-D 6. Replace M12. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1146
- Description: Trailing edge stopper motor/R malfunction. <When FS-537 or FS-537SD is installed> The trailing edge stopper home position detection sensor/R (PS7) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the trailing edge stopper motor/R (M11) is turned ON.
- Causes: <When FS-537 or FS-537SD is installed> • Trail edge stopper motor/R (M11) • Trail edge stopper sensor/R (PS7) • FS control board (FSCB)
- Troubleshooting Guides: 1. Check the connector between M11-relay CN4-relay CN3-FSCB J21 for proper connection and correct as necessary. 2. Check the connector of M11 for proper drive coupling, and correct as necessary. 3. Check the connector between PS7-relay CN4-relay CN3-FSCB J21 for proper connection and correct as necessary. 4. PS7 I/O check, sensor check • Control signal: FSCB J21-16 (ON) • Location of electrical component: FS-537/FS-537SD 5-D 5. M11 operation check • Control signal: FSCB J21-17 to 20 • Location of electrical component: FS-537/FS-537SD 5-D 6. Replace M11. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1152
- Description: Paper transport belt motor’s malfunction. <When FS-537SD is installed> Even after a predetermined period of time has elapsed since the paper transport belt motor (M34) starts operation, the lock signal is not set to L (turning).
- Causes: • Paper transport belt motor (M34) • SD control board (SDCB) • FS control board (FSCB)
- Troubleshooting Guides: 1. Check the connector between M34-relay CN21-FSCB J24for proper connection and correct as necessary. 2. Check the connector of M34 for proper drive coupling and correct as necessary. 3. M34 operation check • Control signal: FSCB J24-1 to 11 • Location of electrical component: FS-537/FS-537SD 7-M 4. Replace M34. 5. Replace SDCB. 6. FSCB F4 conduction check 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1156
- Description: SD paddle motor malfunction. <When FS-536SD or FS-537SD is installed> The paddle home sensor (PS5) is not turned OFF (blocked) or ON (unblocked) even after the set period of time has elapsed while the SD paddle motor (M7) is turning.
- Causes: <When FS-536SD or FS-537SD is installed> • SD paddle motor (M7) • Paddle home sensor (PS5) • SD control board (SDCB) • FS control board (FSCB)
- Troubleshooting Guides: 1. Check the connector between M7-SDCB J8 for proper connection and correct as necessary. 2. Check the connector of M7 for proper drive coupling and correct as necessary. 3. Check the connector between PS5-SDCB J8 for proper connection and correct as necessary. 4. PS5 I/O check, sensor check • Control signal: SDCB J8-3 (ON) • Location of electrical component: FS-536/FS-536SD 4-P, FS-537/FS-537SD 3-P 5. M7 operation check • Control signal: SDCB J8-4 to 7 • Location of electrical component: FS-536/FS-536SD 4-P, FS-537/FS-537SD 3-P 6. Replace M7. (FS-536SD/FS-537SD) 7. Replace SDCB. (FS-536SD/FS-537SD) 8. Replace FSCB. (FS-536SD/FS-537SD) NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD) • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1184
- Description: Paper discharge control motor malfunction.
<When FS-536 or FS-536SD is installed> The paper delivery control sensor (PS28) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed while the paper receiving control motor (M12) is energized.
<When FS-537 or FS-537SD is installed> The paper delivery control sensor (PS11) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed while the paper receiving control motor (M15) is energized. - Causes: <When FS-536 or FS-536SD is installed> • Paper receiving control motor (M12) • Paper delivery control sensor (PS28) • FS control board (FSCB)
<When FS-537 or FS-537SD is installed> • Paper receiving control motor (M15) • Paper delivery control sensor (PS11) • FS control board (FSCB) - Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed 1. Check the connector between M12-relay CN1-FSCB J14 for proper connection and correct as necessary. 2. Check the connector of M12 for proper drive coupling and correct as necessary. 3. Check the connector between PS28-relay CN1-FSCB J14 for proper connection and correct as necessary. 4. PS28 I/O check, sensor check • Control signal: FSCB J14<B>-3 (ON) • Location of electrical component: FS-536/FS-536SD 2 to 3-C 5. M12 operation check • Control signal: FSCB J14<A>-9 to 12 • Location of electrical component: FS-536/FS-536SD 2-C 6. Replace M12. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD)
(b) When FS-537 or FS-537SD is installed 1. Check the connector between M15-FSCB J19 for proper connection and correct as necessary. 2. Check the connector of M15 for proper drive coupling and correct as necessary. 3. Check the connector between PS11-relay CN10<A>-FSCB J20 for proper connection and correct as necessary. 4. PS11 I/O check, sensor check • Control signal: FSCB J20<A>-3 (ON) • Location of electrical component: FS-537/FS-537SD 10-D 5. M15 operation check • Control signal: FSCB J19-1 to 4 • Location of electrical component: FS-537/FS-537SD 10-D 6. Replace M15. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1195
- Description: Paper discharge control motor malfunction. <When FS-536SD or FS-537SD is installed> The curl cover detection sensor (PS2) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the paper discharge control motor (M2) is turned ON.
- Causes: <When FS-536SD or FS-537SD is installed> • Paper discharge control motor (M2) • Curl cover detection sensor (PS2) • SD control board (SDCB) • FS control board (FSCB)
- Troubleshooting Guides: 1. Check the connector between M2-relay CN22 (FS-536SD), CN25 (FS-537SD)-relay CN21 (FS-536SD), CN26 (FS-537SD)-SDCB J5 for proper connection and correct as necessary. 2. Check the connector of M2 for proper drive coupling and correct as necessary. 3. Check the connector between PS2-relay CN22 (FS-536SD), CN25 (FS-537SD)-relay CN21 (FS-536SD), CN26 (FS-537SD)-SDCB J5 for proper connection and correct as necessary. 4. PS2 I/O check, sensor check • Control signal: SDCB J5-3 (ON) • Location of electrical component: FS-536/FS-536SD 4-L, FS-537/FS-537SD 3-K 5. M2 operation check • Control signal: SDCB J5-4 to 7 • Location of electrical component: FS-536/FS-536SD 4-L, FS-537/FS-537SD 3-K 6. Replace M2. (FS-536SD/FS-537SD) 7. Replace SDCB. (FS-536SD/FS-537SD) 8. Replace FSCB. (FS-536SD/FS-537SD) NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD) • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1196
- Description: Center fold guide motor’s drive malfunction. <When FS-536SD or FS-537SD is installed> The guide home sensor (PS7) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the center fold roller motor (M6) is turned ON.
- Causes: <When FS-536SD is installed> <When FS-537SD is installed> • Center fold guide motor (M6) • Guide home sensor (PS7) • SD control board (SDCB) • FS control board (FSCB)
- Troubleshooting Guides: 1. Check the connector between M6-SDCB J9 for proper connection and correct as necessary. 2. Check the connector of M6 for proper drive coupling and correct as necessary. 3. Check the connector between PS7-SDCB J9 for proper connection and correct as necessary. 4. PS7 I/O check, sensor check • Control signal: SDCB J9-6 (ON) • Location of electrical component: FS-536/FS-536SD 5-P, FS-537/FS-537SD 4-P 5. M6 operation check • Control signal: SDCB J9-7 to 10 • Location of electrical component: FS-536/FS-536SD 4-P, FS-537/FS-537SD 4-P 6. Replace M6. (FS-536SD/FS-537SD) 7. Replace SDCB. (FS-536SD/FS-537SD) 8. Replace FSCB. (FS-536SD/FS-537SD) NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD) • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1197
- Description: Tri-folding guide motor’s drive malfunction. <When FS-536SD or FS-537SD is installed> The tri-folding gate home sensor (PS11) is not turned OFF (blocked) or ON (unblocked) even after the set period of time has elapsed while the tri-folding guide motor (M8) is energized.
- Causes: <When FS-536SD or FS-537SD is installed> • Tri-folding guide motor (M8) • Tri-folding gate home sensor (PS11) • SD control board (SDCB) • FS control board (FSCB)
- Troubleshooting Guides: 1. Check the connector between M8-SDCB J8 for proper connection and correct as necessary. 2. Check the connector of M8 for proper drive coupling and correct as necessary. 3. Check the connector between PS11-SDCB J8 for proper connection and correct as necessary. 4. PS11 I/O check, sensor check • Control signal: SDCB J8-10 (ON) • Location of electrical component: FS-536/FS-536SD 3-P, FS-537/FS-537SD 3-P 5. M8 operation check • Control signal: SDCB J8-11 to 14 • Location of electrical component: FS-536/FS-536SD 3-P, FS-537/FS-537SD 2-P 6. Replace M8. (FS-536SD/FS-537SD) 7. Replace SDCB. (FS-536SD/FS-537SD) 8. Replace FSCB. (FS-536SD/FS-537SD) NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD) • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C11A2
- Description: Accommodation roller pressure/ retraction malfunction.
<When FS-536 or FS-536SD is installed> The receiving roller retraction sensor (PS11) is not turned OFF (blocked) or ON (unblocked) even after the set period of time has elapsed after the receiving roller retraction motor (M4) is turned ON.
<When FS-537 or FS-537SD is installed> The receiving roller retraction sensor (PS22) is not turned OFF (blocked) or ON (unblocked) even after the set period of time has elapsed after the receiving roller retraction motor (M10) is turned ON. - Causes: <When FS-536 or FS-536SD is installed> • Receiving roller retraction motor (M4) • Receiving roller retraction sensor (PS11) • FS control board (FSCB)
<When FS-537 or FS-537SD is installed> • Receiving roller retraction motor (M10) • Receiving roller retraction sensor (PS22) • FS control board (FSCB) - Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed 1. Check the connector between M4-FSCB J4 for proper connection and correct as necessary. 2. Check the connector of M4 for proper drive coupling and correct as necessary. 3. Check the connector between PS11-FSCB J4 for proper connection and correct as necessary. 4. PS11 I/O check, sensor check • Control signal: FSCB J4<B>-16 (ON) • Location of electrical component: FS-536/FS-536SD 16-C 5. M4 operation check • Control signal: FSCB J4<A>-1 to 4 • Location of electrical component: FS-536/FS-536SD 13-C 6. Replace M4. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD)
(b) When FS-537 or FS-537SD is installed 1. Check the connector between M10-FSCB J12 for proper connection and correct as necessary. 2. Check the connector of M10 for proper drive coupling, and correct as necessary. 3. Check the connector between PS22-FSCB J12 for proper connection and correct as necessary. 4. PS22 I/O check, sensor check • Control signal: FSCB J12<B>-7 (ON) • Location of electrical component: FS-537/FS-537SD 17-D 5. M10 operation check • Control signal: FSCB J12<B>-1 to 4 • Location of electrical component: FS-537/FS-537SD 17-D 6. Replace M10. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C11C5
- Description: Paper size detect board malfunction. <When FS-537+PK-523 or FS-537SD+PK-523 is installed> The size of a transported paper is not detected, causing no punch operation.
- Causes: Paper size detect board (PSDTB)
- Troubleshooting Guides: 1. Check the sensor part of PSDTB, to clean if it is dirty. 2. Check the connector between PSDTB-PKCB CN38 for proper connection and correct as necessary. 3. Replace PSDTB.
- Code: C11E1
- Description: Paper exit switching drive malfunction.
<When FS-536 or FS-536SD is installed> The exchange folded paper output sensor (PS30) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the FNS entry transport motor (M2) is turned ON.
<When FS-537 or FS-537SD is installed> The route change gate home sensor (PS21) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the route change gate motor (M4) is turned ON. - Causes: <When FS-536 or FS-536SD is installed> • FNS entry transport motor (M2) • Exchange folded paper output sensor (PS30) • FS control board (FSCB)
<When FS-537 or FS-537SD is installed> • Route change gate motor (M4) • Route change gate home sensor (PS21) • FS control board (FSCB) - Troubleshooting Guides: (a) When FS-536 or FS-536SD is installed 1. Check the connector between M2-FSCB J9 for proper connection and correct as necessary. 2. Check the connector of M2 for proper drive coupling and correct as necessary. 3. Check the connector between PS30-FSCB J4 for proper connection and correct as necessary. 4. PS30 I/O check, sensor check • Control signal: FSCB J4<A>-15 (ON) • Location of electrical component: FS-536/FS-536SD 14-C 5. M2 operation check • Control signal: FSCB J9<A>-1 to 4 • Location of electrical component: FS-536/FS-536SD 12-C 6. Replace M2. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.7 FS-536/FS-536SD)
(b) When FS-537 or FS-537SD is installed 1. Check the connector between M4-FSCB J12 for proper connection and correct as necessary. 2. Check the connector of M4 for proper drive coupling and correct as necessary. 3. Check the connector between PS21-FSCB J12 for proper connection and correct as necessary. 4. PS21 I/O check, sensor check • Control signal: FSCB J12<B>-12 (ON) • Location of electrical component: FS-537/FS-537SD 18-D 5. M4 operation check • Control signal: FSCB J21<B>-8 to 9 • Location of electrical component: FS-537/FS-537SD 18-D 6. Replace M4. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C11E2
- Description: Paper exit switching (JS) drive malfunction. <When FS-537 or FS-537SD is installed> The sub tray/JS route change gate home sensor (PS23) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the sub tray discharge motor (M18) is turned ON.
- Causes: • Sub tray discharge motor (M18) • Sub tray/JS route change gate home sensor (PS23) • FS control board (FSCB)
- Troubleshooting Guides: 1. Check the connector between M18-FSCB J12 for proper connection and correct as necessary. 2. Check the connector of M18 for proper drive coupling and correct as necessary. 3. Check the connector between PS23-FSCB J12 for proper connection and correct as necessary. 4. PS23 I/O check, sensor check • Control signal: FSCB J12<A>-16 (ON) • Location of electrical component: FS-537/FS-537SD 17-D 5. M18 operation check • Control signal: FSCB J12<A>-5 to 6 • Location of electrical component: FS-537/FS-537SD 16-D 6. Replace M18. 7. Replace FSCB. NOTICE • Link to the wiring diagram ( N.3.3 FS-537/FS-537SD)
- Code: C1403
- Description: PK flash ROM error. <When FS-537+PK-523 or FS-537SD+PK-523 is installed> Data of flash ROM of the PK is determined to be faulty when the main power switch is turned ON.
- Causes: Punch control board (PKCB)
- Troubleshooting Guides: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace PKCB.
- Code: C1404
- Description: PI flash ROM error. <When FS-537+PI-507 or FS-537SD+PI-507 is installed> Data of flash ROM of the PI is determined to be faulty when the main power switch is turned ON.
- Causes: PI drive board (PIDB)
- Troubleshooting Guides: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace PIDB.
- Code: C2101
- Description: Charge cleaning motor/K malfunction. During backward and return movement of the cleaner material, the charging cleaner home sensor (PS43) is not turned OFF (unblocked) after a predetermined period of time has elapsed.
- Causes: • Drum unit • Charging cleaner home sensor (PS43) • Charging cleaner return sensor (PS44) • Charge cleaning motor/K (M15) • PH relay board (PHRYB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the drum unit for proper connection and correct as necessary. 2. Check the connector between M15-PHRYB CN4 for proper connection and correct as necessary. 3. Check the connector of M15 for proper drive coupling and correct as necessary. 4. Check the connector between PS43-PHRYB CN6 for proper connection and correct as necessary. 5. Check the connector between PS44-PHRYB CN6 for proper connection and correct as necessary. 6. PS43 I/O check, sensor check • Control signal: PHRYB CN6-5 (ON) • Location of electrical component: 3-B 7. PS44 I/O check, sensor check • Control signal: PHRYB CN6-8 (ON) • Location of electrical component: 4-B 8. M15 operation check • Control signal: PHRYB CN4-1 to 2 • Location of electrical component: 5-B, 6-B 9. Replace the drum unit. 10. Replace M15. 11. PHRYB F2 conduction check. 12. Replace PHRYB. 13. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C2151
- Description: Transfer roller pressure welding alienation. • The 2nd transfer pressure sensor (PS50) does not turn OFF (unblock) (retracting) even after the lapse of a given period of time after the 2nd transfer pressure motor (M3) has started rotating during the 2nd image transfer roller is retracting. • The 2nd transfer pressure sensor (PS50) does not ON (block) (pressuring) even after the lapse of a given period of time after the 2nd transfer pressure motor (M3) has started rotating during the 2nd image transfer roller is pressuring.
- Causes: • 2nd transfer pressure motor (M3) • 2nd transfer pressure sensor (PS50) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between M3-relay CN271B-PFTDB CN8 for proper connection and correct as necessary. 2. Check the connector of M3 for proper drive coupling and correct as necessary. 3. Check the connector between PS50-relay CN271A-PFTDB CN2 for proper connection and correct as necessary. 4. PS50 I/O check, sensor check • Control signal: PFTDB CN2-9 (ON) • Location of electrical component: 5-P 5. M3 operation check • Control signal: PFTDB CN8-1 (REM) • Location of electrical component: 6-P 6. Replace M3. 7. PFTDB F17 conduction check 8. Replace PFTDB. 9. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C2152, C2153, C2155, C2157
- Description: • C2152: Transfer belt fault at initial position return • C2153: Transfer belt spacing fault at K pressure switching • C2155: Transfer belt contact fault after K pressure established • C2157: Transfer belt contact fault at all retraction switching.
• The 1st transfer pressure sensor/K (PS51) does not detect ‘switch from retraction to pressure’ or ‘switch from pressure to retraction’ within a given period of time during an initial position return. • The 1st transfer pressure sensor/K (PS51) does not detect “switch from retraction to pressure” within a given period of time after pressure operation has started. • The 1st transfer pressure sensor/K (PS51) is unblocked even after a given period time when pressure operation has finished. • The 1st transfer pressure sensor/K (PS51) does not detect “switch from pressure to retraction” within a given period of time after retraction operation has started; or the PS51 is blocked after a given period time when the retraction operation is finished. - Causes: • Transfer belt unit • 1st transfer pressure motor (M21) • 1st transfer pressure sensor/K (PS51) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between M21-relay CN428-MFPB CN19E for proper connection and correct as necessary. 2. Check the connector of M21 for proper drive coupling and correct as necessary. 3. Check the transfer roller pressure gear of the transfer belt unit for proper engagement and the roller for rolling operation, and correct any faulty motion. 4. Check the connector between PS51-relay CN297-MFPB CN27E for proper connection and correct as necessary. 5. PS51 I/O check, sensor check • Control signal: MFPB CN27E<A>-1 (ON) • Location of electrical component: 16-C 6. M21 operation check • Control signal: MFPB CN19E-5 to 8 • Location of electrical component: 2-K 7. Replace M21. 8. Replace the transfer belt unit. 9. MFPB F2E or F7E conduction check 10. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C2163
- Description: PC charge malfunction. When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time.
- Causes: • Drum unit • High voltage unit/1 (HV1) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the drum unit for proper connection and correct as necessary. 2. Check the connector between HV1 CN1-MFPB CN9E for proper connection and correct as necessary. 3. Replace the drum unit. 4. Replace HV1. 5. Replace MFPB
- Code: C2204
- Description: Waste toner transport motor’s failure to turn. The waste toner lock sensor (PS23) continues to be turned ON (blocked) or OFF (unblocked) for a predetermined period of time when the motor is turning.
- Causes: • Waste toner lock sensor (PS23) • Waste toner transport motor (M20) • PH relay board (PHRYB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Clean the PS23 if it has toner or paper dust, etc. 2. Replacing the waste toner box. 3. Check the connector between M20-relay CN220 (bizhub C958/808 only)-relay CN219 (bizhub C958/808 only)-PHRYB CN4 for proper connection and correct as necessary. 4. Check the connector of M20 for proper drive coupling and correct as necessary. 5. Check the connector between PS23-MFPB CN27E for proper connection and correct as necessary. 6. PS23 I/O check, sensor check • Control signal: MFPB CN27E<A>-9 (ON) • Location of electrical component: 17-C 7. M20 operation check • Control signal: PHRYB CN4-3 to 6 • Location of electrical component: 5-B, 6-B 8. Replace M20. 9. PHRYB F2 conduction check. 10. Replace PHRYB. 11. MFPB F2E conduction check 12. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C2257, C2258
- Description: • C2257: Cleaning brush motor’s failure to turn • C2258: Cleaning brush motor’s turning at abnormal timing
C2257: The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. C2258: The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. - Causes: • Transfer belt unit (cleaner unit) • Cleaning brush motor (M38) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between M38-MFPB CN21E for proper connection and correct as necessary. 2. Check the connector of M38 for proper drive coupling and correct as necessary. 3. Check the cleaner unit gear of the transfer belt unit for rotation and correct any faulty rotation. 4. M38 operation check • Control signal: MFPB CN21E-1 to 7 • Location of electrical component: 11-K 5. Replace M38. 6. Replace the transfer belt unit. 7. MFPB F5E conduction check 8. Replace MFPB. NOTICE • Link to the wiring diagram (bizhub 958/808/758, bizhub PRO 958)
- Code: C2259, C225A
- Description: • C2259: Developing motor/K failure to turn • C225A: Developing motor/K turning at abnormal timing
C2259: The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. C225A: The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. - Causes: • Developing unit • Developing motor/K (M19) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between M19-MFPB CN10E for proper connection and correct as necessary. 2. Check the connector of M19 for proper drive coupling and correct as necessary. 3. M19 operation check • Control signal: MFPB CN10E-15 to 19 • Location of electrical component: 5-K, 7-K 4. Replace M19. 5. Replace the developing unit. 6. MFPB F9E conduction check 7. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C225B, C225C
- Description: C225B: PC motor/K failure to turn C225C: PC motor/K turning at abnormal timing
C225B: The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. C225C: The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. - Causes: • Drum unit • PC motor/K (M18) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between M18-MFPB CN10E for proper connection and correct as necessary. 2. Check the connector of M18 for proper drive coupling and correct as necessary. 3. M18 operation check • Control signal: MFPB CN10E-10 (REM), MFPB CN10E-13 (LOCK) • Location of electrical component: 5-K, 7-K 4. Replace M18. 5. Replace the drum unit. 6. MFPB F2E or F9E conduction check 7. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C2350
- Description: Toner suction fan failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
- Causes: • Toner suction fan (FM7) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between FM7-relay CN326-MFPB CN24E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM7 operation check • Control signal: MFPB CN24E-7 (DRIVE), MFPB CN24E-9 (LOCK) • Location of electrical component: 1-K 4. Replace FM7. 5. MFPB F6E conduction check 6. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C2353
- Description: IU cooling fan/out’s failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
- Causes: • IU cooling fan /out (FM15) • PH relay board (PHRYB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between FM15-PHRYB CN5 for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM15 operation check • Control signal: PHRYB CN5-1 (DRIVE), PHRYB CN5-3 (LOCK) • Location of electrical component: 3-B 4. Replace FM15. 5. PHRYB F2 conduction check. 6. Replace PHRYB. 7. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C2356
- Description: IU cooling fan/in’s failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
- Causes: • IU cooling fan /in (FM16) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between FM16-relay CN700-MFPB CN18E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM16 operation check • Control signal: MFPB CN18E-9 (DRIVE), MFPB CN18E-11 (LOCK) • Location of electrical component: 15 to 16-K 4. Replace FM16. 5. MFPB F7E conduction check 6. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C2414
- Description: Developing unit new article release. The status with the new unit is not cleared after the new developing unit is set.
- Causes: • Developing unit • MFP board (MFPB)
- Troubleshooting Guides: 1. Reinstall developing unit. 2. Replace the developing unit. 3. Replace MFPB.
- Code: C2557
- Description: Abnormally low toner density detected black TCR sensor. When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper.
- Causes: • Developing unit • Toner cartridge • Toner empty sensor/K (PZS/K) • Toner supply motor/K (M12) • Toner cartridge motor/CK (M14) • MFP board (MFPB)
- Troubleshooting Guides: 1. Perform image troubleshooting procedure if image density is low. 2. Check the connector between M12-relay CN258-MFPB CN18E for proper connection and correct as necessary. 3. Check the connector between M14-relay CN321-relay CN428-MFPB CN19E for proper connection and correct as necessary. 4. Check the connector of M12 and M14 for proper drive coupling and correct as necessary. 5. Check the connector between PZS/K-relay CN253-MFPB CN27E for proper connection and correct as necessary. 6. PZS/K I/O check, sensor check • Control signal: MFPB CN27E<A>-11 (ON) • Location of electrical component: 17-C 7. M12 operation check (At this time, developing/drum unit must be non-installation.) • Control signal: MFPB CN18E-15 to 18 • Location of electrical component: 15-K 8. M14 operation check • Control signal: MFPB CN19E-1 to 4 • Location of electrical component: 2-K 9. Replace M12. 10. Replace M14. 11. Reinstall developing unit. 12. Reinstall the toner cartridge. 13. If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them. 14. Replace the developing unit. 15. MFPB F7E or IC80E conduction check 16. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C2558
- Description: Abnormally high toner density detected black TCR sensor. The TC ratio of the toner determined by the toner replenishment control is detected to be the predetermined value or over for consecutive times.
- Causes: • Developing unit • Toner cartridge • Sub hopper unit • MFP board (MFPB)
- Troubleshooting Guides: 1. Reinstall developing unit. 2. Reinstall the toner cartridge. 3. Replace the developing unit. 4. Replace MFPB. 5. Replace the sub hopper unit.
- Code: C255C
- Description: Black TCR sensor adjustment failure. TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
- Causes: • Developing unit • MFP board (MFPB)
- Troubleshooting Guides: 1. Reinstall developing unit. 2. Replace the developing unit. 3. Replace MFPB.
- Code: C2564
- Description: Black TCR sensor failure. • The TCR sensor input is 0. • This detection is used for detecting disconnection of TCR sensor connector.
- Causes: • Developing unit • PH relay board (PHRYB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Reinstall developing unit. 2. Check the connector between the developing unit-relay CN214-PHRYB CN6 for proper connection and correct as necessary. 3. Replace the developing unit. 4. PHRYB PS1 conduction check. 5. Replace PHRYB. 6. Replace MFPB
- Code: C2650, C265B
- Description: • C2650: Main backup media access 1 error • C265B: Main backup media access 2 error
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error. • The error was found when reading out the counter value. • The main body detects that the back up board is not mounted. - Causes: • C2650: Back up board/1 (ERB/1) • C265B: Back up board/2 (ERB/2) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between ERB-MFPB CN5E for proper connection and correct as necessary. 2. Replace MFPB. 3. Replace ERB. (ERB/1 / ERB/2) 4. If the above actions do not solve the problem, contact KM.
- Code: C265A
- Description: Main backup media wrongly installation. The ERB/1 and ERB/2 are mounted in a reverse direction.
- Causes: • Back up board/1 (ERB/1) • Back up board/2 (ERB/2)
- Troubleshooting Guides: 1. Check to see if the ERB/1 and ERB/2 are mounted in a reverse direction. 2. Check the type of the installed ERB and replace it if it is a wrong one. 3. Replace ERB. (ERB/1 / ERB/2)
- Code: C2A14
- Description: Drum unit new release failure. The status with the new unit is not cleared after the new drum unit is set.
- Causes: • Drum unit • MFP board (MFPB)
- Troubleshooting Guides: 1. Clean the connection between the drum unit and the developing unit if dirty. 2. Reinstall the drum unit. 3. Check the harness for proper connection and correct as necessary. 4. Replace the drum unit. 5. Replace MFPB.
- Code: C2A24
- Description: Toner cartridge new release failure. The status with the new unit is not cleared after the new toner cartridge is set.
- Causes: • Toner cartridge • MFP board (MFPB)
- Troubleshooting Guides: 1. Clean the connection between the toner cartridge and the machine if dirty. 2. Reinstall the toner cartridge. 3. Check the harness for proper connection and correct as necessary. 4. Replace the toner cartridge. 5. Replace MFPB.
- Code: C3101, C3103
- Description: • C3101: Pressure roller pressure failure • C3103: Pressure roller release failure
C3101: • The fusing pressure home sensor (PS59) is not turned ON (pressed state) after the set period of time after the fusing pressure roller pressure operation is started. • The fusing pressure home sensor (PS59) is not ON (pressed state) when the fusing pressure roller pressure operation is completed.
C3103: • The fusing pressure home sensor (PS59) is not turned OFF (retracted state) even after the set period of time after the fusing pressure roller retraction operation is started. • The fusing pressure home sensor (PS59) is not OFF (retracted state) when the fusing pressure roller retraction operation is completed. - Causes: • Fusing unit • Fusing pressure home sensor (PS59) • Fusing pressure motor (M34) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between M34-MFPB CN16E for proper connection and correct as necessary. 2. Check the connector of M34 for proper drive coupling and correct as necessary. 3. Check the fusing unit-relay CN260-MFPB CN30E for proper connection and correct or change as necessary. 4. PS59 I/O check, sensor check • Control signal: MFPB CN30E-11 (ON) • Location of electrical component: 9-C, 12-C 5. M34 operation check • Control signal: MFPB CN16E-8 to 11 • Location of electrical component: 10-K 6. Replace M34. 7. Replace the fusing unit. 8. MFPB F2E or F14E conduction check 9. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C3102
- Description: Heating roller failure to turn. During any state other than printing operation, the hard latch signal from one or both of the heating roller rotation latch detection 1 and the heating roller rotation latch detection 2 is turned ON.
- Causes: • Fusing unit • Fusing belt rotation sensor (PS56) (bizhub 958, bizhub PRO 958) • Heating roller rotation sensor (PS56) (bizhub 808/758) • Fusing motor (M30) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the fusing unit for proper connection and correct as necessary. 2. Check the connector between M30-MFPB CN16E for proper connection and correct as necessary. 3. Check the connector of M30 for proper drive coupling and correct as necessary. 4. Check the fusing unit-relay CN260-MFPB CN30E for proper connection and correct or change as necessary. 5. PS56 I/O check, sensor check • Control signal: MFPB CN30E-14 (ON) • Location of electrical component: 9-C, 12-C 6. M30 operation check • Control signal: MFPB CN16E-4 (REM), MFPB CN16E-7 (LOCK) • Location of electrical component: 10-K 7. Replace M30. 8. Replace the fusing unit. 9. MFPB F2E or F14E conduction check 10. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C3201, C3202
- Description: • C3201: Fusing motor failure to turn • C3202: Fusing motor turning at abnormal timing
• C3201: The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. • C3202: The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. - Causes: • Fusing motor (M30) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between M30-MFPB CN16E for proper connection and correct as necessary. 2. Check the loading status of the fusing unit drive, and correct the error as necessary. 3. M30 operation check • Control signal: MFPB CN16E-4 (REM), MFPB CN16E-7 (LOCK) • Location of electrical component: 10-K 4. Replace M30. 5. MFPB F14E conduction check 6. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C3303
- Description: Paper cooling fan/out’s failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
- Causes: • Paper cooling fan/out (FM13) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between FM13-relay CN323-MFPB CN27E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM13 operation check • Control signal: MFPB CN27E<B>-10 (DRIVE), MFPB CN27E<B>-12 (LOCK) • Location of electrical component: 16-C 4. Replace FM13. 5. MFPB F6E conduction check 6. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C3304
- Description: Switchback paper cooling fan/2’s failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
- Causes: • Switchback paper cooling fan/2 (FM5) • Paper feed/transport drive board (PFTDB)
- Troubleshooting Guides: 1. Check the connector between FM5-relay CN282-relay CN280-relay CN279-relay CN271B-PFTDB CN2 for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM5 operation check. • Control signal: PFTDB CN2-18 (LOCK) • Location of electrical component: 5-P 4. Replace FM5. 5. PFTDB F14 conduction check 6. Replace PFTDB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C3305
- Description: Switchback paper cooling fan/1’s failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
- Causes: • Switchback paper cooling fan/1 (FM4) • Paper feed/transport drive board (PFTDB)
- Troubleshooting Guides: 1. Check the connector between FM4-relay CN283-relay CN280-relay CN279-relay CN271B-PFTDB CN2 for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM4 operation check • Control signal: PFTDB CN2-15 (LOCK) • Location of electrical component: 5-P 4. Replace FM4. 5. PFTDB F14 conduction check 6. Replace PFTDB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C3310
- Description: Output tray exhaust fan’s failure to turn (bizhub 958/808, bizhub PRO 958 only). The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
- Causes: • Output tray exhaust fan (FM18) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between FM18-relay CN701-MFPB CN18E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM18 operation check • Control signal: MFPB CN18E-8 (LOCK) • Location of electrical component: 16-K 4. Replace FM18. 5. MFPB F7E conduction check 6. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C3423
- Description: Fusing warm-up trouble (Pressure) (bizhub 958, bizhub PRO 958 only). After warm-up operation starts, the pressure roller thermistor/2 (TH3) does not detect a temperature as high as a predetermined one though a predetermined period of time has elapsed.
- Causes: • Fusing unit • Pressure roller thermistor/2 (TH3) • IH power supply unit (IHPU) • Noise filter (NF1) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary. 4. Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary. 5. Check the connector between IHPU CN8-MFPB CN18E for proper connection and correct as necessary. 6. Replace the fusing unit. 7. Replace IHPU. 8. MFPB IC80E conduction check 9. Replace MFPB. 10. Replace NF1.
- Code: C3425
- Description: Fusing warm-up trouble.
bizhub 958, bizhub PRO 958: • After warm-up operation starts, the fusing belt temperature sensor/1 (TEMS1) does not detect a temperature increasing to a predetermined one though a predetermined period of time has elapsed. • From the start of warm-up operation, it does not terminate within a predetermined period of time. b
izhub 808/758: • After warm-up operation starts, the heating roller temperature sensor/1 (TEMS1) does not detect a temperature increasing to a predetermined one though a predetermined period of time has elapsed. • From the start of warm-up operation, it does not terminate within a predetermined period of time. - Causes: • Fusing unit • Fusing belt temperature sensor/1 (TEMS1) (bizhub 958, bizhub PRO 958) • Heating roller temperature sensor/1 (TEMS1) (bizhub 808/758) • IH power supply unit (IHPU) • Noise filter (NF1) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary. 4. Check the connector between TEMS1-relay CN512-MFPB CN29E for proper connection and correct as necessary. 5. Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary. 6. Check the connector between IHPU CN8-MFPB CN18E for proper connection and correct as necessary. 7. Replace the fusing unit. 8. Replace IHPU. 9. MFPB IC80E conduction check 10. Replace MFPB. 11. Replace NF1.
- Code: C3722, C3725, C3726
- Description: • C3722: Fusing abnormally high temperature detection (Edge of the heating roller) • C3725: Fusing abnormally high temperature detection (Middle of the heating roller) • C3726: Fusing abnormally high temperature detection (Center of the heating roller)
bizhub 958, bizhub PRO 958: • C3722: Detected temperature of the fusing belt temperature sensor/3 (TEMS3) goes beyond a given temperature for a given period of time consecutively. • C3725: Detected temperature of the fusing belt temperature sensor/1 (TEMS1) goes beyond a given temperature for a given period of time consecutively. • C3726: Detected temperature of the fusing belt temperature sensor/2 (TEMS2) goes beyond a given temperature for a given period of time consecutively.
bizhub 808/758: • C3722: Detected temperature of the heating roller temperature sensor/3 (TEMS3) goes beyond a given temperature for a given period of time consecutively. • C3725: Detected temperature of the heating roller temperature sensor/1 (TEMS1) goes beyond a given temperature for a given period of time consecutively. • C3726: Detected temperature of the heating roller temperature sensor/2 (TEMS2) goes beyond a given temperature for a given period of time consecutively. - Causes: • Fusing unit • C3725: Fusing belt temperature sensor/1 (TEMS1) (bizhub 958, bizhub PRO 958) • C3725: Heating roller temperature sensor/1 (TEMS1) (bizhub 808/758) • C3726: Fusing belt temperature sensor/2 (TEMS2) (bizhub 958, bizhub PRO 958) • C3726: Heating roller temperature sensor/2 (TEMS2) (bizhub 808/758) • C3722: Fusing belt temperature sensor/3 (TEMS3) (bizhub 958, bizhub PRO 958) • C3722: Heating roller temperature sensor/3 (TEMS3) (bizhub 808/758) • IH power supply unit (IHPU) • Noise filter (NF1) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary. 4. Check the connector between TEMS1, TEMS2, TEMS3-relay CN512-MFPB CN29E for proper connection and correct as necessary. 5. Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary. 6. Check the connector between IHPU CN8-MFPB CN18E for proper connection and correct as necessary. 7. Replace the fusing unit. 8. Replace IHPU. 9. Replace MFPB. 10. Replace NF1
- Code: C3723
- Description: Fusing abnormally high temperature detection (pressure) (bizhub 958, bizhub PRO 958 only). Detected temperature of the pressure roller thermistor/2 (TH3) goes beyond a given temperature for a given period of time consecutively.
- Causes: • Fusing unit • Pressure roller thermistor/2 (TH3) • IH power supply unit (IHPU) • Noise filter (NF1) • Pressure roller power supply unit (PRPU) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary. 4. Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary. 5. Check the connector between IHPU CN8-MFPB CN18E for proper connection and correct as necessary. 6. Replace the fusing unit. 7. Replace IHPU. 8. Replace PRPU. 9. Replace MFPB. 10. Replace NF1.
- Code: C3731
- Description: Fusing abnormally high temperature (Hard protector). An abnormally high temperature of the hard protector signal is detected.
- Causes: • Fusing unit • Fusing belt temperature sensor/1 (TEMS1) (bizhub 958, bizhub PRO 958) • Heating roller temperature sensor/1 (TEMS1) (bizhub 808/758) • Fusing belt temperature sensor/2 (TEMS2) (bizhub 958, bizhub PRO 958) • Heating roller temperature sensor/2 (TEMS2) (bizhub 808/758) • Fusing belt temperature sensor/3 (TEMS3) (bizhub 958, bizhub PRO 958) • Heating roller temperature sensor/3 (TEMS3) (bizhub 808/758) • Pressure roller thermistor/2 (TH3) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary. 4. Check the connector between TEMS1, TEMS2, TEMS3-relay CN512-MFPB CN29E for proper connection and correct as necessary. 5. Replace the fusing unit. 6. Replace TEMS1, TEMS2, TEMS3. 7. Replace MFPB.
- Code: C3732, C3736, C3737
- Description: • C3732: Fusing abnormally high temperature detection hard protector (Edge of the heating roller) • C3736: Fusing abnormally high temperature detection hard protector (Middle of the heating roller) • C3737: Fusing abnormally high temperature detection hard protector (Center of the heating roller)
• An abnormally high temperature is detected on the hard protector circuit (edge of the heating roller). • An abnormally high temperature is detected on the hard protector circuit (middle of the heating roller). • An abnormally high temperature is detected on the hard protector circuit (center of the heating roller). - Causes: • Fusing unit • C3737: Fusing belt thermostat (TS1) (bizhub 958, bizhub PRO 958) • C3737: Heating roller thermostat (TS1) (bizhub 808/758) • C3736: Fusing belt temperature sensor/2 (TEMS2) (bizhub 958, bizhub PRO 958) • C3736: Heating roller temperature sensor/2 (TEMS2) (bizhub 808/758) • C3732: Fusing belt temperature sensor/3 (TEMS3) (bizhub 958, bizhub PRO 958) • C3732: Heating roller temperature sensor/3 (TEMS3) (bizhub 808/758) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary. 4. Check the connector between TEMS2, TEMS3-relay CN512-MFPB CN29E for proper connection and correct as necessary. 5. Replace the fusing unit. 6. Replace TEMS2, TEMS3. 7. Replace MFPB.
- Code: C3733
- Description: Fusing abnormally high temperature detection hard protector (pressure) (bizhub 958, bizhub PRO 958 only). An abnormally high temperature is detected on the hard protector (pressure).
- Causes: • Fusing unit • Pressure roller thermistor/2 (TH3) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB.
- Code: C3822, C3825, C3826
- Description: • C3822: Fusing abnormally low temperature detection (Edge of the heating roller) • C3825: Fusing abnormally low temperature detection (Middle of the heating roller) • C3826: Fusing abnormally low temperature detection (Center of the heating roller).
bizhub 958, bizhub PRO 958: • C3822: Detected temperature of the fusing belt temperature sensor/3 (TEMS3) goes below a given temperature for a given period of time consecutively. • C3825: Detected temperature of the fusing belt temperature sensor/1 (TEMS1) goes below a given temperature for a given period of time consecutively. • C3826: Detected temperature of the fusing belt temperature sensor/2 (TEMS2) goes below a given temperature for a given period of time consecutively.
bizhub 808/758 • C3822: Detected temperature of the heating roller temperature sensor/3 (TEMS3) goes below a given temperature for a given period of time consecutively. • C3825: Detected temperature of the heating roller temperature sensor/1 (TEMS1) goes below a given temperature for a given period of time consecutively. • C3826: Detected temperature of the heating roller temperature sensor/2 (TEMS2) goes below a given temperature for a given period of time consecutively. - Causes: • Fusing unit • C3825: Fusing belt temperature sensor/1 (TEMS1) (bizhub 958, bizhub PRO 958) • C3825: Heating roller temperature sensor/1 (TEMS1) (bizhub 808/758) • C3826: Fusing belt temperature sensor/2 (TEMS2) (bizhub 958, bizhub PRO 958) • C3826: Heating roller temperature sensor/2 (TEMS2) (bizhub 808/758) • C3822: Fusing belt temperature sensor/3 (TEMS3) (bizhub 958, bizhub PRO 958) • C3822: Heating roller temperature sensor/3 (TEMS3) (bizhub 808/758) • IH power supply unit (IHPU) • Noise filter (NF1) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary. 4. Check the connector between TEMS1, TEMS2, TEMS3-relay CN512-MFPB CN29E for proper connection and correct as necessary. 5. Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary. 6. Check the connector between IHPU CN8-MFPB CN18E for proper connection and correct as necessary. 7. Replace the fusing unit. 8. Replace IHPU. 9. MFPB IC80E conduction check 10. Replace MFPB. 11. Replace NF1.
- Code: C3823
- Description: Fusing abnormally low temperature detection (pressure). Detected temperature of the pressure roller thermistor/2 (TH3) goes beyond a given temperature for a given period of time consecutively.
- Causes: • Fusing unit • Pressure roller thermistor/2 (TH3) • IH power supply unit (IHPU) • Noise filter (NF1) • Pressure roller power supply unit (PRPU) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary. 4. Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary. 5. Check the connector between IHPU CN8-MFPB CN18E for proper connection and correct as necessary. 6. Replace the fusing unit. 7. Replace IHPU. 8. MFPB IC80E conduction check 9. Replace PRPU. 10. Replace MFPB. 11. Replace NF1.
- Code: C3903
- Description: Thermostat breaks detection. The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
- Causes: • Fusing unit • Fusing belt thermostat (TS1) (bizhub 958, bizhub PRO 958) • Heating roller thermostat (TS1) (bizhub 808/758) • IH power supply unit (IHPU) • Noise filter (NF1) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary. 4. Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary. 5. Check the connector between IHPU CN8-MFPB CN18E for proper connection and correct as necessary. 6. Replace the fusing unit. 7. Replace IHPU. 8. MFPB F3E conduction check 9. Replace MFPB. 10. Replace NF1.
- Code: C3922, C3925, C3926
- Description: C3922: • Fusing sensor wire breaks detection (Edge of the heating roller) • Fusing unit for incorrect marketing area (The fusing unit for incorrect marketing area is installed)
C3925: Fusing sensor wire breaks detection (Middle of the heating roller)
C3926: • Fusing sensor wire breaks detection (Center of the heating roller) • Fusing unit for incorrect marketing area (The fusing unit for incorrect marketing area is installed)
bizhub 958, bizhub PRO 958: • C3922: After a predetermined period of time after the warm-up stage is started, the fusing belt temperature sensor/3 (TEMS3) voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time. • C3925: After a predetermined period of time after the warm-up stage is started, the fusing belt temperature sensor/1 (TEMS1) voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time. • C3926: After a predetermined period of time after the warm-up stage is started, the fusing belt temperature sensor/2 (TEMS2) voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time.
bizhub 808/758: • C3922: After a predetermined period of time after the warm-up stage is started, the heating roller temperature sensor/3 (TEMS3) voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time. • C3925: After a predetermined period of time after the warm-up stage is started, the heating roller temperature sensor/1 (TEMS1) voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time. • C3926: After a predetermined period of time after the warm-up stage is started, the heating roller temperature sensor/2 (TEMS2) voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time. - Causes: • Fusing unit • C3925: Fusing belt temperature sensor/1 (TEMS1) (bizhub 958, bizhub PRO 958) • C3925: Heating roller temperature sensor/1 (TEMS1) (bizhub 808/758) • C3926: Fusing belt temperature sensor/2 (TEMS2) (bizhub 958, bizhub PRO 958) • C3926: Heating roller temperature sensor/2 (TEMS2) (bizhub 808/758) • C3922: Fusing belt temperature sensor/3 (TEMS3) (bizhub 958, bizhub PRO 958) • C3922: Heating roller temperature sensor/3 (TEMS3) (bizhub 808/758) • IH power supply unit (IHPU) • Noise filter (NF1) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary. 4. Check the connector between TEMS1, TEMS2, TEMS3-relay CN512-MFPB CN29E for proper connection and correct as necessary. 5. Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary. 6. Check the connector between IHPU CN8-MFPB CN18E for proper connection and correct as necessary. 7. Replace the fusing unit. 8. Replace IHPU. 9. MFPB IC80E conduction check 10. Replace MFPB. 11. Replace NF1.
- Code: C3923
- Description: Fusing sensor wire breaks detection (pressure). The maximum value and minimum value of detected temperature of the pressure roller thermistor/2 (TH3) is compared after a lapse of given time from starting of warm up and the gap between the value of maximum and minimum is below a given temperature.
- Causes: • Fusing unit • Pressure roller thermistor/2 (TH3) • IH power supply unit (IHPU) • Noise filter (NF1) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary. 4. Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary. 5. Check the connector between IHPU CN8-MFPB CN18E for proper connection and correct as necessary. 6. Replace the fusing unit. 7. Replace IHPU. 8. Replace MFPB. 9. Replace NF1.
- Code: C392A
- Description: Fusing belt temperature sensor/1 contamination (Middle of the heating roller) (bizhub 958) Heating roller temperature sensor contamination (Middle of the heating roller
(bizhub 808/758)bizhub 958, bizhub PRO 958: During waiting after a predetermined period of time after the warm-up stage terminates, the temperature detected by the fusing belt thermistor/1 (TH1) exceeds that detected by the fusing belt temperature sensor/1 (TEMS1) above a predetermined temperature, and this state continues for a predetermined period of time.
bizhub 808/758: During waiting after a predetermined period of time after the warm-up stage terminates, the temperature detected by the heating roller thermostat/1 (TH1) exceeds that detected by the heating roller temperature sensor/1 (TEMS1) above a predetermined temperature, and this state continues for a predetermined period of time. - Causes: • Fusing unit • Fusing belt temperature sensor/1 (TEMS1) (bizhub 958, bizhub PRO 958) • Heating roller temperature sensor/1 (TEMS1) (bizhub 808/758) • Fusing belt thermistor/1 (TH1) (bizhub 958, bizhub PRO 958) • Heating roller thermostat/1 (TH1) (bizhub 808/758) • IH power supply unit (IHPU) • DC power supply unit (DCPU) • MFP board (MFPB)
- Troubleshooting Guides: 1. Wipe the TEMS1 clean of dirt if any. • Clear away a dirt or a foreign object on the sensor with a cotton swab. • When a dirt is left even if you cleaned the sensor by above procedure, clear away a dirt or a foreign object on the sensor using a cotton swab dampened with the alcohol. And, wipe off the sensor with a dry cotton swab afterwards. 2. Check the TEMS1 for installed position and proper connector connection. 3. Check the TH1 for installed position and proper connector connection. 4. Check the connection of the fusing unit. 5. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary. 6. Check the connector between IHPU CN8-MFPB CN18E for proper connection and correct as necessary. 7. Check the connector between DCPU CN009-MFPB CN31E for proper connection and correct as necessary. 8. Replace the fusing unit. 9. Replace MFPB.
- Code: C392B
- Description: Fusing disconnection error detection (difference of temperature)
bizhub 958, bizhub PRO 958: The difference between the temperature corrected by the fusing belt thermistor/1 (TH1) and the temperature detected by the fusing belt temperature sensor/1 (TEMS1) exceeds a predetermined value after warm up.
bizhub 808/758: The difference between the temperature corrected by the heating roller thermistor/1 (TH1) and the temperature detected by the heating roller temperature sensor/1 (TEMS1) exceeds a predetermined value after warm up. - Causes: • Fusing unit • Fusing belt temperature sensor/1 (TEMS1) (bizhub 958, bizhub PRO 958) • Heating roller temperature sensor/1 (TEMS1) (bizhub 808/758) • Fusing belt thermistor/1 (TH1) (bizhub 958, bizhub PRO 958) • Heating roller thermostat/1 (TH1) (bizhub 808/758) • IH power supply unit (IHPU) • Noise filter (NF1) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary. 4. Check the connector between TEMS1-relay CN512-MFPB CN29E for proper connection and correct as necessary. 5. Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary. 6. Check the connector between IHPU CN8-MFPB CN18E for proper connection and correct as necessary. 7. Replace the fusing unit. 8. Replace IHPU. 9. Replace MFPB. 10. Replace NF1.
- Code: C3B02, C3B03
- Description: C3B02: • IH malfunction (CPU) • IH power supply for incorrect marketing area (The IH power supply for incorrect marketing area is installed) C3B03: IH malfunction (monitor)
C3B02: A failure in communication with the fusing CPU continues for a predetermined period of time. C3B03: Though the IH heater is OFF, mechanically, the ON status is detected. (Malfunction of IH heater operation) - Causes: • Fusing unit • IH coil (IHC) • IH power supply unit (IHPU) • IH magnetic erasing board (IHMEB) • Noise filter (NF1) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary. 4. Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary. 5. Check the connector between IHPU-IHC for proper connection and correct as necessary. 6. Check the connector between IHC-IHMEB for proper connection and correct as necessary. 7. Replace the fusing unit. 8. Replace IHC. 9. Replace IHPU. 10. Replace IHMEB. 11. MFPB F2E or F3E conduction check 12. Replace MFPB. 13. Replace NF1.
- Code: C3B07, C3B08
- Description: C3B07: • IH input power error • Fusing unit for incorrect marketing area (The fusing unit for incorrect marketing area is installed) • IH power supply for incorrect marketing area (The IH power supply for incorrect marketing area is installed) C3B08: IH input voltage error
C3B07: • While the IH heater was ON, input power stayed at the high voltage power detection value or over for more than the predetermined period of time. • While the IH heater was ON, input power was at the low power detection value or under for more than the predetermined period of time. • While the IH heater was ON, input power was at the high voltage detection value or over for more than the predetermined period of time. • While the IH heater was ON, input power was below the low voltage detection value or under for more than the predetermined period of time. • While the IH heater was ON, inverter power stayed at the upper limit value or over for more than the predetermined period of time. • While the IH heater was ON, output voltage halt was detected.
C3B08: • While the IH heater was ON, input power was at the high voltage detection value or over for more than the predetermined period of time. • While the IH heater was ON, input voltage was at the low power detection value or under for more than the predetermined period of time. - Causes: • Fusing unit • IH coil (IHC) • IH power supply unit (IHPU) • Noise filter (NF1) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary. 3. Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary. 4. Check the connector between IHPU CN8-MFPB CN18E for proper connection and correct as necessary. 5. Check the marketing area of the fusing unit. If the marketing area is incorrect, replace the fusing unit for proper marketing area. 6. Check the marketing area of IHPU. If the marketing area is incorrect, replace IHPU for proper marketing area. 7. Replace IHC. 8. Replace IHPU. 9. Replace MFPB. 10. Replace NF1.
- Code: C3B09
- Description: IH communication error. No signal has been received from the IH power supply a predetermined number of consecutive times.
- Causes: • Fusing unit • IH coil (IHC) • IH power supply (IHPU) • IH magnetic erasing board (IHMEB) • Noise filter (NF1) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary. 4. Check the connector between MFPB CN18E-IHPBCN8for proper connection and correct as necessary. 5. Check the connector between NF1CN2-IHPU CN1 for proper connection and correct as necessary. 6. Check the connector between IHPU CN7-IHMEB CN1 for proper connection and correct as necessary. 7. Check the connector between IHPU-IHC for proper connection and correct as necessary. 8. Check the connector between IHC-IHMEB for proper connection and correct as necessary. 9. Replace the fusing unit. 10. Replace IHC. 11. Replace IHPU. 12. Replace IHMEB. 13. Replace NF1. 14. Replace MFPB.
- Code: C4002
- Description: PH communication error. When the PH relay board (PHRYB) is receiving data, a communication error is detected.
- Causes: • PH relay board (PHRYB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. MFPB F2E conduction check 3. Replace MFPB. 4. PHRYB F1 conduction check. 5. Replace PHRYB.
- Code: C40A1 … C40C5
- Description: • C40A1: Mechanical controller sub-CPU communication error • C40A2: Mechanical controller PF communication data error • C40A3: Mechanical controller PF transmission timeout • C40A4: Mechanical controller PF communication pulse error • C40C3: CTL PF transmission timeout 1 • C40C5: CTL PF transmission timeout 2
A CPU communication error is detected. - Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. MFPB F2E conduction check 4. Replace MFPB.
- Code: C4101
- Description: • Polygon motor rotation trouble • PH unit for incorrect marketing area
• The polygon motor fails to turn stably even after the lapse of a given period of time after activating the polygon motor. • Motor lock signal detects HIGH for a given period time consecutively during the polygon motor is rotating. • The PH unit for incorrect marketing area is installed. - Causes: • PH unit • PH relay board (PHRYB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the type of the installed PH unit and replace it if it is a wrong one. 2. Check the connector between the PH unit-PHRYB CN3 for proper connection and correct as necessary. 3. Replace the PH unit. 4. PHRYB F3 conduction check. 5. Replace PHRYB. 6. Replace MFPB.
- Code: C4301
- Description: PH cooling fan’s failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
- Causes: • PH cooling fan (FM14) • PH relay board (PHRYB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between FM14-relay CN202-PHRYB CN4 for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM14 operation check • Control signal: PHRYB CN4-8 (DRIVE), PHRYB CN4-9 (LOCK) • Location of electrical component: 6-B, 7-B 4. Replace FM14. 5. PHRYB F2 conduction check. 6. Replace PHRYB. 7. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C4501
- Description: Laser malfunction. • SOS signal is not detected even after the lapse of a given period of time after starting the laser output. • SOS signal is not detected for a given period of time during printing or IDC sensor adjustment.
- Causes: • PH unit • PH relay board (PHRYB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between the PH unit-PHRYB CN8 for proper connection and correct as necessary. 2. Replace the PH unit. 3. PHRYB IC5 conduction check. 4. Replace PHRYB. 5. Replace MFPB.
- Code: C4810
- Description: Wrong paper feed/transport drive installed. The destination of the main body and that of the paper feed/transport drive board are mismatched.
- Causes: • Paper feed/transport drive board (PFTDB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the marketing area of PFTDB If the marketing area is incorrect, replace PFTDB for proper marketing area. 2. Replace PFTDB. 3. Replace MFPB.
- Code: C5104, C5105
- Description: • C5104: Transfer belt motor’s rotation trouble • C5105: Transfer belt motor’s turning at abnormal timing.
C5104: The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. C5105: The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. - Causes: • Transfer belt unit • Transfer belt motor (M1) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between M1-MFPB CN10E for proper connection and correct as necessary. 2. Check the loading status of the transfer belt drive, and correct the error as necessary. 3. Check the drive gear of the transfer belt unit for rotation and correct any faulty rotation. 4. M1 operation check • Control signal: MFPB CN10E-3 (REM), MFPB CN10E-6 (LOCK) • Location of electrical component: 6-K, 8-K 5. Replace M1. 6. Replace the transfer belt unit. 7. MFPB F2E or F11E conduction check 8. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C5304
- Description: IH power supply cooling fan’s failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
- Causes: • IH power supply cooling fan (FM10) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between FM10-relay CN293-MFPB CN18E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM10 operation check • Control signal: MFPB CN18E-13 (DRIVE), MFPB CN18E-14 (LOCK) • Location of electrical component: 15-K 4. Replace FM10. 5. MFPB F7E conduction check 6. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C5306
- Description: IH coil cooling fan’s failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
- Causes: • IH coil cooling fan (FM11) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between FM11-relay CN324-MFPB CN24E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM11 operation check • Control signal: MFPB CN24E-1 (DRIVE), MFPB CN24E-3 (LOCK) • Location of electrical component: 1-K 4. Replace FM11. 5. MFPB F6E conduction check 6. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C5351
- Description: DC power supply cooling fan’s failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
- Causes: • DC power supply cooling fan (FM9) • DC power supply unit (DCPU) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between FM9-relay CN333-MFPB CN23E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM9 operation check • Control signal: MFPB CN23E-7 (DRIVE), MFPB CN23E-9 (LOCK) • Location of electrical component: 11-K 4. Replace FM9. 5. Replace DCPU. 6. MFPB F6E conduction check 7. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C5354
- Description: Ozone ventilation fan’s failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
- Causes: • Ozone ventilation fan (FM6) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between FM6-relay CN322-MFPB CN27E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM6 operation check • Control signal: MFPB CN27E<B>-7 (DRIVE), MFPB CN27E<B>-9 (LOCK) • Location of electrical component: 16-C 4. Replace M6. 5. MFPB F6E conduction check 6. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C5355
- Description: Toner cartridge cooling fan’s failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
- Causes: • Toner cartridge cooling fan (FM8) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connector between FM8-relay CN522-MFPB CN24E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM8 operation check • Control signal: MFPB CN24E-4 (DRIVE), MFPB CN24E-6 (LOCK) • Location of electrical component: 1-K 4. Replace FM8. 5. MFPB F6E conduction check 6. Replace MFPB. NOTICE: • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C5372
- Description: MFP control board CPU temperature failure. Temperature failure of CPU on the MFP board was detected.
- Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Reboot the machine. 2. Check for clogging in the ventilation path between the MFPB and the power supply cooling fan, and correct as necessary. 3. Replace MFPB.
- Code: C5601
- Description: Engine control malfunction. Engine control malfunction is detected with port monitor control.
- Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connectors on MFPB for proper connection and correct as necessary. 2. Rewrite the firmware. 3. Replace MFPB.
- Code: C5605, C5606
- Description: • C5605: Engine communication data error • C5606: Engine transmission timeout.
A communication error is detected between CPUs. - Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace MFPB.
- Code: C5610
- Description: PH LD drive communication error. LD drive write data and read data disagree with each other a predetermined number of consecutive times.
- Causes: • PH unit • PH relay board (PHRYB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Reboot the machine. 2. Check the connector between the PH unit-PHRYB CN8 for proper connection and correct as necessary. 3. Check the connector between PHRYB CN1-MFPB CN6E for proper connection and correct as necessary. 4. Replace the PH unit. 5. Replace PHRYB. 6. Replace MFPB.
- Code: C6001
- Description: DF related configuration error 1. Inconsistency in the configuration with the installed DF is detected on the main body.
- Causes: • DF control board (DFCB) • Dual scan image processing board (DSIPB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the type of the installed DF and replace it if it is a wrong one. 2. Correct the harness connection between DFCB CN12-relay CN47-MFPB CN1E if faulty. 3. Correct the harness connection between DSIPB CN1-MFPB CN24 if faulty. 4. Replace DFCB. 5. Replace DSIPB. 6. Replace MFPB.
- Code: C6002
- Description: DF related configuration error 2. Inconsistency in the configuration with the installed DF is detected on the DF.
- Causes: • DF control board (DFCB) • Dual scan image processing board (DSIPB)
- Troubleshooting Guides: 1. Check the type of the installed DF and replace it if it is a wrong one. 2. Correct the harness connection between DFCB CN12-relay CN47-MFPB CN1E if faulty. 3. Correct the harness connection between DSIPB CN1-MFPB CN24 if faulty. 4. Check the connectors of the dual scan image processing board (DSIPB) for proper connection, and correct as necessary. (Direction of the point of contact and connection state of the flat cable in particular)
- Code: C6102, C6103
- Description: • C6102: Drive system home sensor malfunction • C6103: Slider over running
C6102: • The scanner home sensor is unable to detect the scanner located at its home position. • The scanner home sensor is unable to detect a scanner even when the scanner motor has been driven to move the scanner over the maximum travelling distance. • The scanner home sensor detects the scanner when the scanner has moved the maximum travelling distance from the position, at which it blocks the scanner home sensor.
C6103: The scanner home sensor detects the scanner at its home position during a period of time that begins with the time when a prescan command and a scan preparation command are executed and ends when a home return command is executed. - Causes: • Scanner home sensor (PS201) • Scanner motor (M201) • Scanner drive board (SCDB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Correct or change the scanner drive (pulley, gear, belt) if it is faulty. 2. Correct the scanner motor set screw if loose. 3. Adjust [Image Position: Leading Edge] and [Sub Scan Zoom Adj.]. 4. Check the connector between PS201-SCDB CN6 for proper connection and correct as necessary. 5. Check the connector between M201-SCDB CN4 for proper connection and correct as necessary. 6. Check the connector between SCDB CN2-MFPB CN1E for proper connection and correct as necessary. 7. PS201 I/O check, sensor check • Control signal: SCDB CN6-3 (ON) • Location of electrical component: 17-U 8. M201 operation check • Control signal: SCDB CN4-1 to 4 • Location of electrical component: 17-U 9. Replace SCDB 10. MFPB F3E conduction check 11. Replace MFPB. NOTICE • Link to the wiring diagram ( N.1 bizhub 958/808/758, bizhub PRO 958)
- Code: C6104, C6105
- Description: • C6104: Back side cleaning home sensor abnormality (initial) • C6105: Back side cleaning home sensor abnormality (normal)
C6104: • The back side cleaning home sensor (PS9) does not change from H to L even after the lapse of a given period of time after the home position detecting operation is started at the initial operation. • The back side cleaning home sensor (PS9) does not change from H to L even after the lapse of a given period of time after the home position detecting operation is started at the initial operation.
C6105: At the time of operation other than the initial operation, the back side cleaning home sensor (PS9) error is detected. - Causes: • Back side cleaning home sensor (PS9) • Back side cleaning motor (M7) • DF control board (DFCB)
- Troubleshooting Guides: 1. Check the connector between M7-DFCB CN14 for proper connection and correct as necessary. 2. Check the connector of M7 for proper drive coupling and correct as necessary. 3. Check the connector between PS9-relay CN121-DFCB CN18 for proper connection and correct as necessary. 4. PS9 I/O check, sensor check • Control signal: DFCB CN18-6 (ON) • Location of electrical component: DF 3 to 4-C 5. M7 operation check • Control signal: DFCB CN14-6 to 9 • Location of electrical component: DF 6-C 6. Replace M7. 7. DFCB ICP4 or ICP8 conduction check. 8. Replace DFCB. NOTICE • Link to the wiring diagram ( N.2 Dual scan document feeder)
- Code: C6704
- Description: Image input time out. Image data is not input from the scanner to the MFP board (MFPB).
- Causes: • MFP board (MFPB) • CCD board (CCDB)
- Troubleshooting Guides: 1. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Memory Bus Check] -> [Scanner -> Memory], and conduct the memory bus function. 2. Correct the harness connection between scanner section and MFPB if faulty. 3. MFPB F3E conduction check 4. Replace MFPB. 5. Replace the CCD unit.
- Code: C6751
- Description: CCD gain adjustment failure. • The adjustment value is 0 or 255 during a CCD clamp adjustment. • The peak value of the output data is 64 or less during a CCD gain adjustment.
- Causes: • LED exposure unit • Scanner drive board (SCDB) • CCD board (CCDB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Correct the harness connection between CCDB PJ3-MFPB CN9 if faulty. 2. Correct the harness connection between CCDB PJ5-SCDB CN5 if faulty. 3. Correct the harness connection between SCDB CN1-DCPU CN005 if faulty. 4. Check for possible extraneous light and correct as necessary. 5. Clean the lens, mirrors, CCD surface, and shading sheet if dirty. 6. Correct reflective mirror of the scanner if faulty, or change scanner mirror. 7. Replace SCDB 8. Replace the CCD unit. 9. MFPB F3E conduction check 10. Replace MFPB.
- Code: C6752
- Description: ASIC clock input error (front side). When starting the machine, verification on reading and writing the predetermined value for image processing ASIC on CCD board (CCDB) was conducted, and verification failure was detected.
- Causes: • MFP board (MFPB) • CCD board (CCDB)
- Troubleshooting Guides: 1. Correct the harness connection of CCDB if faulty. 2. Replace the CCD unit. 3. MFPB F3E conduction check 4. Replace MFPB.
- Code: C6753
- Description: ASIC clock input error (back side). When starting the machine, verification on reading and writing the predetermined value for image processing ASIC on dual scan image processing board (DSIPB) was conducted, and verification failure was detected.
- Causes: • CIS module (CIS) • Dual scan image processing board (DSIPB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Correct the harness connection between CIS J101-DSIPB CN2 if faulty. 2. Correct the harness connection between DSIPB CN1-MFPB CN24 if faulty. 3. Replace CIS. 4. DFPU ICP1 conduction check. 5. Replace DSIPB. 6. MFPB F3E conduction check 7. Replace MFPB.
- Code: C6754, C6755
- Description: • C6754: CIS clamp adjustment failure • C6755: CIS gain adjustment failure
• C6754: After the gain adjustment is performed at the start-up, the CIS clamp adjustment value is too high or too low. • C6755: After the gain adjustment is performed at the start-up, the peak value of the output data is lower than a given value. - Causes: • CIS module (CIS) • Dual scan image processing board (DSIPB) • DF power supply (DFPU) • MFP board (MFPB)
- Troubleshooting Guides: 1. Correct the harness connection between CIS J101-DSIPB CN2 if faulty. 2. Correct the harness connection between CIS J102-DFPU CN2 if faulty. 3. Check for possible extraneous light and correct as necessary. 4. Clean the back side reading glass and the shading sheet if dirty. 5. Replace CIS. 6. Replace DSIPB. 7. DFPU ICP1 conduction check. 8. Replace DFPU. 9. MFPB F3E conduction check 10. Replace MFPB.
- Code: C6756
- Description: CCD power-supply voltage malfunction. Power is not supplied to CCD after the lapse of a given period of time after the main power switch is turned ON or the machine recovers from the sleep mode.
- Causes: • CCD board (CCDB) • Scanner drive board (SCDB) • DC power supply unit (DCPU)
- Troubleshooting Guides: 1. Correct the harness connection between CCDB PJ5-SCDB CN5 if faulty. 2. Correct the harness connection between SCDB CN1 and DCPU CN005 if faulty. 3. Replace the CCD unit. 4. Replace SCDB. 5. Replace DCPU.
- Code: C6901, C6902, C6903
- Description: • C6901: DSC board mount failure 1 • C6902: DSC Bus check NG1-1 • C6903: DSC Bus check NG1-2
• C6901: When MFP detects that DSC board/1 (front side) is not properly installed. • C6902, C6903: When DSC bus check (front side) detects an error. - Causes: • DSC board/1 (DSCB/1: SC-508) • MFP board (MFPB)
- Troubleshooting Guides: 1. Correct the harness connection of DSCB/1 if faulty. 2. Replace DSCB/1. 3. Replace MFPB.
- Code: C6911, C6912, C6913
- Description: • C6911: DSC board mount failure 2 • C6912: DSC Bus check NG2-1 • C6913: DSC Bus check NG2-2
• C6911: When MFP detects that DSC board/2 (back side) is not properly installed. • C6912, C6913: When DSC bus check (back side) detects an error. - Causes: • DSC board/2 (DSCB/2; SC-508) • Dual scan image processing board (DSIPB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Correct the harness connection of DSCB/2 if faulty. 2. Correct the harness connection of DSIPB if faulty. 3. Replace DSCB/2. 4. Replace DSIPB. 5. Replace MFPB.
- Code: C6F01
- Description: Scanner sequence trouble 1. The original transport interval becomes shorter than the predetermined value due to an original transport control error in original reading in DF.
- Causes: • MFP board (MFPB) • DF control board (DFCB)
- Troubleshooting Guides: 1. Correct the harness connection between main body and DF if faulty. 2. Replace DFCB. 3. Replace MFPB.
- Code: C8101
- Description: Before reading pressure welding alienation mechanism trouble. • During a pressure motion being performed, the before read sensor (PS6) output does not change from H to L. • During a retraction motion being performed, the before read sensor (PS6) output does not change from L to H.
- Causes: • Reading roller pressure/retraction motor (M6) • Before read sensor (PS6) • DF control board (DFCB)
- Troubleshooting Guides: 1. Check the connector between M6-relay CN118-DFCB CN4 for proper connection and correct as necessary. 2. Check the connector of M6 for proper drive coupling and correct as necessary. 3. Check the connector between PS6-relay CN120-DFCB CN11 for proper connection and correct as necessary. 4. PS6 I/O check, sensor check • Control signal: DFCB CN11-2 (ON) • Location of electrical component: DF 1-C 5. M6 operation check • Control signal: DFCB CN4-1 to 2 • Location of electrical component: DF 10-C 6. Replace M6. 7. DFCB ICP9 conduction check. 8. Replace DFCB. NOTICE • Link to the wiring diagram ( N.2 Dual scan document feeder)
- Code: C8103
- Description: Lift up mechanism trouble (Upward movement). The lift up upper sensor (PS2) is not turned ON (unblocked) after a lapse of a given time after the lift-up motor (M5) moves up (is turned forward).
- Causes: • Lift-up motor (M5) • Lift up upper sensor (PS2) • DF control board (DFCB)
- Troubleshooting Guides: 1. Check the connector between M5-DFCB CN9 for proper connection and correct as necessary. 2. Check the connector of M5 for proper drive coupling and correct as necessary. 3. Check the connector between PS2-DFCB CN6 for proper connection and correct as necessary. 4. PS2 I/O check, sensor check • Control signal: DFCB CN6-3 (ON) • Location of electrical component: DF 7-I 5. M5 operation check • Control signal: DFCB CN9-1 to 5 • Location of electrical component: DF 5-C 6. Replace M5. 7. DFCB ICP5 conduction check. 8. Replace DFCB. NOTICE • Link to the wiring diagram ( N.2 Dual scan document feeder)
- Code: C8106
- Description: Lift up mechanism failure (Downward movement). The lift up lower sensor (PS3) is not turned ON (unblocked) after a lapse of a given time after the lift-up motor (M5) goes down (is turned backward).
- Causes: • Lift-up motor (M5) • Lift up lower sensor (PS3) • DF control board (DFCB)
- Troubleshooting Guides: 1. Check the connector between M5-DFCB CN9 for proper connection and correct as necessary. 2. Check the connector of M5 for proper drive coupling and correct as necessary. 3. Check the connector between PS3-DFCB CN10 for proper connection and correct as necessary. 4. PS3 I/O check, sensor check • Control signal: DFCB CN10-3 (ON) • Location of electrical component: DF 10-C 5. M5 operation check • Control signal: DFCB CN9-1 to 5 • Location of electrical component: DF 5-C 6. Replace M5. 7. Replace DFCB. NOTICE • Link to the wiring diagram ( N.2 Dual scan document feeder)
- Code: C8107
- Description: Glass cleaning mechanism trouble. The front side cleaning home sensor (PS18) is not turned ON (unblocked) even after the set period of time has elapsed after the front side cleaning motor (M8) turned ON.
- Causes: • Front side cleaning motor (M8) • Front side cleaning home sensor (PS18) • DF control board (DFCB)
- Troubleshooting Guides: 1. Check the connector between M8-DFCB CN14 for proper connection and correct as necessary. 2. Check the connector between PS18-DFCB CN18 for proper connection and correct as necessary. 3. Check the connector of M8 for proper drive coupling and correct as necessary. 4. PS18 I/O check, sensor check • Control signal: DFCB CN18-3 (ON) • Location of electrical component: DF 3-C 5. M8 operation check • Control signal: DFCB CN14-1 to 4 • Location of electrical component: DF 6-C 6. Replace M8. 7. DFCB ICP8 conduction check. 8. Replace DFCB. NOTICE • Link to the wiring diagram ( N.2 Dual scan document feeder)
- Code: C8302
- Description: Cooling fan motor’s failure. The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
- Causes: • Cooling fan motor (FM) • DF control board (DFCB)
- Troubleshooting Guides: 1. Check the connector between FM-relay CN115-DFCB CN19 for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM operation check • Control signal: DFCB CN19-3 (LOCK) • Location of electrical component: DF 4-C 4. Replace FM. 5. DFCB ICP10 conduction check. 6. Replace DFCB. NOTICE • Link to the wiring diagram ( N.2 Dual scan document feeder)
- Code: C8401
- Description: Nonvolatile memory error. The EEPROM writing is disabled.
- Causes: DF control board (DFCB)
- Troubleshooting Guides: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Check the DFCB connector for proper connection and correct as necessary. 3. Rewrite the firmware. 4. Replace DFCB.
- Code: C8402
- Description: Multi feed detection board failure (When UK-501 is installed). • The AD value went below the predetermined the HI side threshold for two consecutive times. • The AD value went above the predetermined the LOW side threshold for two consecutive times.
- Causes: • Multi feed detection board/1 (transmitter) (MFDB/1) • Multi feed detection board/2 (receiver) (MFDB/2) • Sensor control board (SCB) • DF control board (DFCB)
- Troubleshooting Guides: 1. Remove the film stuck on the window of the lower guide assembly. 2. Use the adjustment sheet for double feed detection kit (UK-501), and select [ADF] -> [Multi-Feed DetectionAdj.]. 3. Use the misdetected paper, and select [ADF] -> [ Multi-Feed DetectionAdj. ]. 4. Check the connector between MFDB/1-relay CN114-SCB CN104 for proper connection and correct as necessary. 5. Check the connector between MFDB/2-SCB CN103 for proper connection and correct as necessary. 6. Check the connector between SCB CN101-DFCB CN8 for proper connection and correct as necessary. 7. MFDB/1 operation check • Control signal: SCB CN104 • Location of electrical component: DF 11-L 8. MFDB/2 operation check • Control signal: SCB CN103 • Location of electrical component: DF 10-J 9. Replace SCB. 10. DFCB ICP11 conduction check 11. Replace DFCB. NOTICE • Link to the wiring diagram ( N.2 Dual scan document feeder)
- Code: C9401, C9402
- Description: • C9401: Exposure LED lighting failure/ROM contents error (MSC) • C9402: Exposure LED lighting abnormally
C9401: • The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment. • The wrong model of firmware is detected in the MFP board when the main power switch is turned ON. • The machine type information (Machine, Type) registered to the machine differs from the actual machine type.
C9402: The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job. - Causes: • LED exposure unit • Flat cable (LED exposure unit) • CCD board (CCDB) • Scanner drive board (SCDB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the machine type information registered and reenter as necessary. For details the machine information, see “ J.3.2 Procedure”. 2. Correct the harness connection between SCDB CN3-LU201 if faulty. 3. Correct the harness connection between SCDB CN2-MFPB CN1E if faulty. 4. Correct the harness connection between CCDB PJ3-MFPB CN9 if faulty. 5. Replace the LED exposure unit. 6. Replace the CCD unit. 7. Replace SCDB 8. MFPB F3E conduction check 9. Replace MFPB.
- Code: C9403, C9404
- Description: • C9403: CIS LED lighting failure • C9404: CIS LED lighting abnormally
• C9403: At the CIS gain adjustment, the machine detected that the output of the CIS LED is lower than the specified value. • C9404: After a scan job is completed, the machine detected that the average output of the CIS LED is greater than the specified value. - Causes: • CIS module (CIS) • DF power supply (DFPU) • Dual scan image processing board (DSIPB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Correct the harness connection between CIS J101-DSIPB CN2 if faulty. 2. Correct the harness connection between CIS J102-DFPU CN2 if faulty. 3. Replace CIS. 4. DFPU ICP1 conduction check. 5. Replace DFPU. 6. Replace DSIPB. 7. MFPB F3E conduction check 8. Replace MFPB.
- Code: CA051, CA052, CA053
- Description: • CA051: Standard controller configuration failure • CA052: Controller hardware error • CA053: Controller start failure
• CA051: The controller of the MFP board (MFPB) is faulty. • CA052: A controller hardware error is detected in the network interface. • CA053: A controller start failure is detected in the controller interface. - Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Check to see if [Service Mode] -> [System 2] -> [Image Controller Setting] has been set to “Controller 0.” If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more. 2. Check the connectors of the MFPB for proper connection and correct as necessary. 3. Replace MFPB.
- Code: CC140
- Description: Trouble related to security.
- Causes: Trouble related to security.
- Troubleshooting Guides: Contact the responsible people of KM before taking some countermeasures.
- Code: CC151, CC152
- Description: • CC151: ROM contents error upon startup (MSC) • CC152: ROM contents error upon startup (IR)
• CC151: A fault is detected in a sequence of ROM contents check of the MSC during starting. • CC152: A fault is detected in a sequence of ROM contents check of the IR during starting. - Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Check the ROM version. 2. Rewrite the firmware. 3. Replace MFPB.
- Code: CC155
- Description: Finisher ROM error. Data of flash ROM of the finishing options is determined to be faulty when the main power switch is turned ON.
- Causes: FS control board (FSCB)
- Troubleshooting Guides: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace FSCB. (FS-536/FS-536SD/FS-537/FS-537SD)
- Code: CC156
- Description: DF ROM error. Data of flash ROM of the DF is determined to be faulty when the main power switch is turned ON.
- Causes: DF control board (DFCB)
- Troubleshooting Guides: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace DFCB.
- Code: CC159, CC15A
- Description: • CC159: ROM contents error upon startup (DSC1) • CC15A: ROM contents error upon startup (DSC2). A fault is detected in a sequence of ROM contents check of the DSC board during starting.
- Causes: • DSC board/1 (DSCB/1; SC-508) • DSC board/2 (DSCB/2; SC-508)
- Troubleshooting Guides: 1. Check DSCB/1 or DSCB/2 connector for proper connection and correct as necessary. 2. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 3. Rewrite the firmware. 4. Replace DSCB/1 or DSCB/2.
- Code: CC15B
- Description: Flash ROM error (saddle). <When FS-536SD or FS-537SD is installed> Data of flash ROM of the saddle is determined to be faulty when the main power switch is turned ON.
- Causes: SD control board (SDCB)
- Troubleshooting Guides: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace SDCB. (FS-536SD/FS-537SD)
- Code: CC163
- Description: ROM contents error (PRT). The wrong model of firmware is detected in the engine during the initial connection to the engine is being checked.
- Causes: • eMMC board (eMMC) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connectors on MFPB for proper connection and correct as necessary. 2. Check the version of the firmware with Firmware Version. 3. Rewrite the firmware. 4. Replace eMMC. 5. If the above actions do not solve the problem, contact KM.
- Code: CC164
- Description: ROM contents error (MSC). • The wrong model of firmware is detected in the MFP board when the main power switch is turned ON. • The machine type information (Machine, Type) registered to the machine differs from the actual machine type.
- Causes: • eMMC board (eMMC) • MFP board (MFPB)
- Troubleshooting Guides: 1. Check the ROM version. 2. Check the machine type information registered and reenter as necessary. For details the machine information, see “ J.3.2 Procedure”. 3. Rewrite the firmware. 4. Replace eMMC. 5. Replace MFPB. 6. If the above actions do not solve the problem, contact KM.
- Code: CC170 … CC186
- Description: • CC170: Dynamic link error during starting (AP0) • CC171: Dynamic link error during starting (AP1) • CC172: Dynamic link error during starting (AP2) • CC173: Dynamic link error during starting (AP3) • CC174: Dynamic link error during starting (AP4) • CC180: Dynamic link error during starting (LDR) • CC181: Dynamic link error during starting (IBR) • CC182: Dynamic link error during starting (IID) • CC183: Dynamic link error during starting (IPF) • CC184: Dynamic link error during starting (IMY) • CC185: Dynamic link error during starting (SPF) • CC186: Dynamic link error during starting (OAP)
A dynamic link error occurs in the program on the MFP board due to an insufficient memory space available, a ROM fault, or other reason when the main power switch is turned ON. - Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. If the malfunction code ‘CC172’ has occurred, access [Service Mode] -> [System 2] -> [Image Controller Setting] and check to see if ‘Controller 1,’ or ‘Others’ is set for [Image Controller Setting]. If any of these is set, select “Controller 0”. 2. If the malfunction code ‘CC180’ has occurred, check to install the appropriate loadable device driver for an authentication unit which is installed to the MFP. When the appropriate loadable device driver is not installed, reinstall the appropriate loadable device driver. 3. Replace MFPB. 4. If the above actions do not solve the problem, contact KM.
- Code: CC190
- Description: Outline font load error. An error occurred while loading the outline font.
- Causes: • MFP board (MFPB) • Hard disk (A) (HDD (A)) • Hard disk (B) (HDD (B): HD-524)
- Troubleshooting Guides: 1. Check the connector between hard disk (A)-MFPB CN8, CN10 for proper connection and correct as necessary. 2. Check the connector between hard disk (B)-MFPB CN7, CN11 for proper connection and correct as necessary. 3. Format the hard disk. 4. Replace the hard disk. (HDD (A) / HDD (B)) 5. Replace MFPB.
- Code: CC191
- Description: Setting parameter load error (LDR). Upon startup, the processing of the loadable device driver setting data file failed. • RAM disk file creation failed. • Reading from the flash ROM failed. • An error occurred in API of the authentication module.
- Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Turn OFF the main power switch, wait for 10 sec., then turn the switch ON. 2. Reinstall the loadable device driver. 3. Rewrite the firmware. 4. Replace MFPB.
- Code: CC211
- Description: Authentication device general error. When using the authentication device, authentication data is not to meet the specifications.
- Causes: • MFP board (MFPB) • Authentication device
- Troubleshooting Guides: 1. Check the USB cable for proper connection. Reconnect the USB cable as necessary. 2. Turn OFF the main power switch, wait for 10 sec. or more, and turn ON the main power switch.
- Code: CC212
- Description: User validation error. • An error occurred while validating the user authentication information. • The loadable device driver is not successfully installed.
- Causes: • MFP board (MFPB) • Authentication device
- Troubleshooting Guides: 1. When this trouble code is generated after installing the loadable device driver, check to see if there is any file other than loadable device driver in USB memory used. If there is any file, reinstall the loadable device driver. 2. Check the USB cable for proper connection. Reconnect the USB cable as necessary. 3. Turn OFF the main power switch, wait for 10 sec. or more, and turn ON the main power switch. 4. Re-register the user authentication information. 5. Replace authentication device.
- Code: CC213
- Description: User registration error/Card information setting error. • IC card advanced settings data is not correct when starting-up the authentication device. • Authentication information data is not correct when starting-up the authentication device. • IC card advanced settings data is not correct when setting the IC card advanced settings. • Authentication information data is not correct when setting the IC card advanced settings. • IC card advanced settings data is not correct when registering the authentication information. • Authentication information data is not correct when registering the authentication information. • IC card advanced settings data is not correct when editing the authentication information. • Authentication information data is not correct when editing the authentication information.
- Causes: • MFP board (MFPB) • Authentication device
- Troubleshooting Guides: 1. Check the USB cable for proper connection. Reconnect the USB cable as necessary. 2. Turn OFF the main power switch, wait for 10 sec. or more, and turn ON the main power switch. 3. Reset the authentication settings. (card type, IC card advanced settings, and etc.) 4. Re-register the user authentication information.
- Code: CC214
- Description: User information deletion error. The deletion of the user information is uncompleted.
- Causes: • MFP board (MFPB) • Authentication device
- Troubleshooting Guides: 1. Check the USB cable for proper connection. Reconnect the USB cable as necessary. 2. Turn OFF the main power switch, wait for 10 sec. or more, and turn ON the main power switch.
- Code: CC216
- Description: Acquisition failure of the number of trials/Initialize error of number of authentication. An error occurred during user authentication using optional authentication unit AU-102.
- Causes: • MFP board (MFPB) • Authentication device
- Troubleshooting Guides: 1. Check the USB cable for proper connection. Reconnect the USB cable as necessary. 2. Turn OFF the main power switch, wait for 10 sec. or more, and turn ON the main power switch. 3. Reset the number of authentication trials.
- Code: CC301
- Description: Authentication customize data error. • The master authentication customize data is corrupted upon startup. • Registration of authentication customize data in the main body has failed upon startup.
- Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Reinstall the authentication customize data. 2. Rewrite the firmware. 3. Replace MFPB.
- Code: CC302
- Description: Authentication customize data version mismatch error. The authentication customize data version is later than the firmware version of the machine.
- Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Rewrite the main body firmware with the latest one and reinstall the authentication customize data. 2. Replace MFPB.
- Code: CCC00
- Description: Public user account track information error. At the first time of startup, the nonvolatile status is reset incompletely due to any trouble (such as a shut off of the main power).
- Causes: eMMC board (eMMC)
- Troubleshooting Guides: 1. Replace eMMC.
- Code: CD002
- Description: JOB RAM save error. The error in save of job data to the memory/ hard disk and its read error are detected.
- Causes: • MFP board (MFPB) • Hard disk (A) (HDD (A)) • Hard disk (B) (HDD (B): HD-524)
- Troubleshooting Guides: 1. Check the connector between hard disk (A)-MFPB CN8, CN10 for proper connection and correct as necessary. 2. Check the connector between hard disk (B)-MFPB CN7, CN11 for proper connection and correct as necessary. 3. Format the hard disk. 4. Replace the hard disk. (HDD (A) / HDD (B)) 5. Replace MFPB.
- Code: CD004, CD00F, CD020
- Description: • CD004: Hard disk access error (connection failure) • CD00F: Hard disk data transfer error • CD020: Hard disk verify error
• CD004: Unable to communicate between the hard disk and MFP board (MFPB). • CD00F: Data transfer from the hard disk is faulty. • CD020: The data abnormality is detected by the hard disk verify check. - Causes: • MFP board (MFPB) • Hard disk (A) (HDD (A)) • Hard disk (B) (HDD (B): HD-524)
- Troubleshooting Guides: 1. Check the connector between hard disk (A)-MFPB CN8, CN10 for proper connection and correct as necessary. 2. Check the connector between hard disk (B)-MFPB CN7, CN11 for proper connection and correct as necessary. 3. Reinstall the hard disk. 4. Replace the hard disk. (HDD (A) / HDD (B)) 5. Replace MFPB.
- Code: CD010
- Description: Hard disk unformat. Unformatted hard disk is connected.
- Causes: • MFP board (MFPB) • Hard disk (A) (HDD (A)) • Hard disk (B) (HDD (B): HD-524)
- Troubleshooting Guides: 1. Carry out the [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format]. 2. Replace the hard disk. (HDD (A) / HDD (B)) 3. Replace MFPB.
- Code: CD011
- Description: Hard disk out of specifications mounted. A hard disk that falls outside the specifications is connected.
- Causes: • Hard disk (A) (HDD (A)) • Hard disk (B) (HDD (B): HD-524)
- Troubleshooting Guides: 1. Check the hard disk specifications. 2. Replace the hard disk. (HDD (A) / HDD (B))
- Code: CD012
- Description: Mount error due to hard disk being unformatted. • The hard disk is not logically formatted after the whole data in the hard disk has been deleted by overwriting. • The hard disk that has replaced an old one is not logically formatted.
- Causes: • Hard disk (A) (HDD (A)) • Hard disk (B) (HDD (B): HD-524)
- Troubleshooting Guides: 1. Logically format the hard disk and then upgrade the firmware. 2. Replace the hard disk. (HDD (A) / HDD (B))
- Code: CD013, CD014
- Description: CD013: HDD mirroring error master CD014: HDD mirroring error slave.
CD013: A R/W error occurs in the master drive during mirroring. CD014: A R/W error occurs in the slave drive during mirroring. - Causes: • Hard disk (A) (HDD (A)) • Hard disk (B) (HDD (B): HD-524)
- Troubleshooting Guides: 1. Turn OFF the main power switch, wait for 10 sec., then turn the switch ON. 2. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Status] and identify the specific hard disk that has developed the error. If an error occurs, ‘Error’ appears in the status column. 3. Replace the hard disk that has developed the error with a new one. (HDD (A) / HDD (B)) 4. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [HDD Mirroring Rebuild] and perform the function.
- Code: CD015
- Description: HDD mirroring error master slave. A R/W error occurs in both drives during mirroring.
- Causes: • Hard disk (A) (HDD (A)) • Hard disk (B) (HDD (B): HD-524)
- Troubleshooting Guides: 1. Turn OFF the main power switch, wait for 10 sec., then turn the switch ON. 2. Replace both hard disk (A) and hard disk (B) with new ones. (HDD (A) / HDD (B)) 3. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format] and perform physical format. 4. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format] and perform logical format. 5. If HDD Data Backup has previously been performed, select [Service Mode] -> [Enhanced Security] -> [HDD Data Backup] -> [Restore] and perform the function. 6. If HDD Data Backup has not been performed previously, install voice data, etc.
- Code: CD016
- Description: HDD mirroring error master (rebuild). A R/W error occurs in the master drive during HDD Mirroring Rebuild.
- Causes: • Hard disk (A) (HDD (A)) • Hard disk (B) (HDD (B): HD-524)
- Troubleshooting Guides: 1. Turn OFF the main power switch, wait for 10 sec., then turn the switch ON. If no problems are encountered, HDD Mirroring Rebuild is automatically performed. 2. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Status] and identify the specific hard disk that has developed the error. If an error occurs, ‘Error’ appears in the status column. 3. Replace the hard disk that has developed the error with a new one. (HDD (A) / HDD (B)) 4. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format] and perform physical format. 5. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format] and perform logical format. 6. If HDD Data Backup has previously been performed, select [Service Mode] -> [Enhanced Security] -> [HDD Data Backup] -> [Restore] and perform the function. 7. If HDD Data Backup has not been performed previously, install voice data, etc.
- Code: CD017
- Description: HDD mirroring error slave (rebuild). A R/W error occurs in the slave drive during HDD Mirroring Rebuild.
- Causes: • Hard disk (A) (HDD (A)) • Hard disk (B) (HDD (B): HD-524)
- Troubleshooting Guides: 1. Turn OFF the main power switch, wait for 10 sec., then turn the switch ON. If no problems are encountered, HDD Mirroring Rebuild is automatically performed. 2. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Status] and identify the specific hard disk that has developed the error. If an error occurs, ‘Error’ appears in the status column. 3. Replace the hard disk that has developed the error with a new one. (HDD (A) / HDD (B)) 4. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [HDD Mirroring Rebuild] and perform the function.
- Code: CD030
- Description: Hard disk management information reading error. The machine fails to read administrative information data saved in the hard disk.
- Causes: • Hard disk (A) (HDD (A)) • Hard disk (B) (HDD (B): HD-524)
- Troubleshooting Guides: 1. Check the connector between hard disk (A)-MFPB CN8, CN10 for proper connection and correct as necessary. 2. Check the connector between hard disk (B)-MFPB CN7, CN11 for proper connection and correct as necessary. 3. Logically format the hard disk. 4. Physically format the hard disk. 5. Replace the hard disk. (HDD (A) / HDD (B))
- Code: CD041 … CD046
- Description: HDD command execution error. The error occurred inside the hard disk.
- Causes: • Hard disk (A) (HDD (A)) • Hard disk (B) (HDD (B): HD-524)
- Troubleshooting Guides: 1. Check the hard disk specifications. 2. Format the hard disk. 3. Replace the hard disk. (HDD (A) / HDD (B))
- Code: CD047 … CD04B
- Description: HDD SCSI library error. The error occurred inside the hard disk.
- Causes: • Hard disk (A) (HDD (A)) • Hard disk (B) (HDD (B): HD-524)
- Troubleshooting Guides: 1. Check the hard disk specifications. 2. Format the hard disk. 3. Replace the hard disk. (HDD (A) / HDD (B))
- Code: CD050
- Description: Hard disk recovery timeout. The hard disk fails to recover from the power save mode within the predetermined period of time.
- Causes: • MFP board (MFPB) • Hard disk (A) (HDD (A)) • Hard disk (B) (HDD (B): HD-524)
- Troubleshooting Guides: 1. Check the connector between hard disk (A)-MFPB CN8, CN10 for proper connection and correct as necessary. 2. Check the connector between hard disk (B)-MFPB CN7, CN11 for proper connection and correct as necessary. 3. Reinstall the hard disk. 4. Format the hard disk. 5. Replace the hard disk. (HDD (A) / HDD (B))
- Code: CD110
- Description: Wireless LAN destination initialization error. When an initialization error occurred on the settings of the wireless LAN in the upgrade kit (UK-212/UK-215).
- Causes:
- Troubleshooting Guides: 1. Check the UK-212 or UK-215 connector for proper connection and correct as necessary. 2. Rewrite the firmware. 3. Reinstall the UK-212or UK-215.
- Code: CD201, CD202, CD203
- Description: • CD201: File memory mounting error • CD202: Memory capacity discrepancy • CD203: Memory capacity discrepancy 2
CD201: • The file memory is not mounted. • The file has any abnormality. CD202: • File memory capacity on the MFP board (MFPB) is not enough. • File memory capacity necessary for duplex printing is not enough. CD203: File memory capacity on the MFP board (MFPB) is not enough. - Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Replace MFPB.
- Code: CD211, CD212
- Description: • CD211: PCI-SDRAM DMA operation failure • CD212: Compression/extraction timeout detection
• CD211: Hardware related to the transfer of memory image of the MFP board (MFPB) fails to respond. • CD212: Hardware related to the BTC compression function of the MFP board (MFPB) fails to respond. - Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Replace MFPB.
- Code: CD241, CD242
- Description: • CD241: Encryption ASIC setting error • CD242: Encryption ASIC mounting error
• CD241: Initialization error of the encrypted ASIC is detected during the machine is starting. • CD242: The faulty of the installation of encrypted ASIC is detected during the machine is starting. - Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Check the MFP board connector for proper connection and correct as necessary. 2. Replace MFPB
- Code: CD261
- Description: USB hub board failure. • When a failure is detected in USB hub board included in the local interface kit. • Non-standard USB device is connected.
- Causes: • MFP board (MFPB) • USB hub board (USBHB: EK-610/EK-611)
- Troubleshooting Guides: 1. Check the operation with another USB device. 2. Check the USB hub board connector for proper connection and correct as necessary. 3. Replace the USB hub board. 4. Replace MFPB.
- Code: CD262
- Description: Extension network adapter installation error. • When the 2nd network card settings is set to “Set” but the upgrade kit (UK-212/UK-215) is not installed. • Upgrade Kit (UK-212/UK-215) is faulty.
- Causes:
- Troubleshooting Guides: 1. Check the settings of [Service Mode] -> [Network Settings] -> [2nd Network Setting] -> [2nd network card settings]. 2. Check the UK-212 or UK-215 connector for proper connection and correct as necessary. 3. Rewrite the firmware. 4. Reinstall the UK-212 or UK-215.
- Code: CD271
- Description: The memory cannot be recognized with the i-Option activated. While the i-Option is activated, the memory on an MFPB cannot be recognized.
- Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Check MFPB for proper connection and correct as necessary. 2. Replace MFPB.
- Code: CD272
- Description: i-Option activated and HDD not installed. While the i-Option is activated, the hard disk is not installed.
- Causes: • MFP board (MFPB) • Hard disk (A) (HDD (A))
- Troubleshooting Guides: 1. Access [Service Mode] -> [System 2] -> [HDD] and check to see if “Installed” is selected. 2. Replace the hard disk (A). 3. Replace MFPB.
- Code: CD313
- Description: TPM key data error. A fault occurs in the TPM key data.
- Causes:
- Troubleshooting Guides: 1. Touch [Recover Data] displayed at the lower right portion on the trouble screen. 2. A screen confirming whether to recover data appears. 3. Select [Yes]. 4. The screen will be shifted to the data restoration screen to perform data restoration. NOTE . When the restoration is performed in a short time, data restoration screen may not be displayed. 5. Check the message which indicates that the data restoration was successfully conducted. Turn OFF the main power switch and turn it ON again more than 10 seconds after. NOTE . In case it failed to restore data, return to the trouble code screen. 6. Replace the current MFPB with a new one. NOTE . Nonvolatile data backup will be automatically performed every hour. Backup can also be performed manually with the following setting. [Service Mode] -> [Enhanced Security] -> [Memory Data Backup]
- Code: CD38E
- Description: Nonvolatile data save error (SPI-Flash). The ‘ISW download flag’ saved in the SPI-Flash has an illegal value.
- Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Rewrite the firmware. 2. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch.
- Code: CD3A0
- Description: Counter error. The total counter values provided by the MFP board and the eMMC board are different.
- Causes: • MFP board (MFPB) • eMMC board (eMMC)
- Troubleshooting Guides: 1. If this error occurs temporarily due to the use of the board removed from another machine, reinstall the original board. 2. Replace the current MFPB with a new one.
- Code: CD3C0
- Description: New board detection. The board is replaced with a new one.
- Causes:
- Troubleshooting Guides: (2) Procedure 1. Wait until “Recover Data” appears. (MFP will reboot maximum 2 times by itself, it may take 5 minutes.) Touch the “Recover Data” button and follow the instructions that appear on the control panel to restore (backup) data.
- Code: CD3xx
- Description: Nonvolatile data error. Abnormality is detected by the abnormal check of each nonvolatile data.
- Causes:
- Troubleshooting Guides: 1. Touch [Recover Data] displayed at the lower right portion on the trouble screen. 2. A screen confirming whether to recover data appears. 3. Select [Yes]. 4. The screen will be shifted to the data restoration screen to perform data restoration. NOTE . When the restoration is performed in a short time, data restoration screen may not be displayed. 5. Check the message which indicates that the data restoration was successfully conducted. Turn OFF the main power switch and turn it ON again more than 10 seconds after. NOTE . In case it failed to restore data, return to the trouble code screen. NOTE . Nonvolatile data backup will be automatically performed every hour. Backup can also be performed manually with the following setting. [Service Mode] -> [Enhanced Security] -> [Memory Data Backup]
- Code: CD401 … CD413
- Description: • CD401: NACK command incorrect • CD402: ACK command incorrect • CD403: Checksum error • CD404: Receiving packet incorrect • CD405: Receiving packet analysis error • CD406: ACK receiving timeout • CD407: Retransmission timeout • CD411: Touch panel board error • CD412: Touch panel type mismatch • CD413: Electrostatic touch panel operation mode error
When abnormality is found in the communication of controller. - Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Check whether there is a strong electromagnetic noise source near the main body. 2. Check the connectors on MFPB for proper connection and correct as necessary. 3. Replace MFPB.
- Code: CD601 … CD603
- Description: Trouble related to security
- Causes:
- Troubleshooting Guides: 1. Turn OFF the main power switch, wait for 10 sec. or more, and turn ON the main power switch. If the above actions do not solve the problem, contact KM.
- Code: CD701, CD702, CD703
- Description: • CD701: Mechanical controller flash ROM writing error • CD702: Mechanical controller flash ROM device error • CD703: FW download communication fault
CD701: A mechanical controller flash ROM writing sequence is interrupted in its mid-operation due to, for example, power being shut off. CD702: An erase error or other device fault occurs during mechanical controller flash ROM writing. CD703: • Irregular data is received during FW downloading. • Places are changed in the order of write completion pulses. • A write completion pulse is received for a memory for which binary writing is not permitted. • Final checksum mismatch in FW download • Two-minute timeout (no response from CTL, the number of transfer data items less than the specified) - Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace MFPB.
- Code: CD704
- Description: Finisher Flash ROM device error (When FS-536, FS-536SD, FS-537, or FS-537SD is installed)
An erase error or other device fault occurs during the finisher flash ROM writing. - Causes: FS control board (FSCB)
- Troubleshooting Guides: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace FSCB. (FS-536/FS-536SD/FS-537/FS-537SD)
- Code: CD705, CD706
- Description: • CD705: Mechanical controller sub-CPU flash ROM device error • CD706: Mechanical controller sub-CPU flash ROM error
• CD705: An erase error or other device fault occurs during mechanical controller sub-CPU flash ROM writing. • CD706: A data error is determined to exist in the mechanical controller sub-CPU flash ROM during starting. - Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace MFPB.
- Code: CDF50, CDF70, CDFA0
- Description: • CDF50: ASIC image version failure • CDF70: ASIC image access failure • CDFA0: ASIC image error
Communication error is detected between the MFP board (MFPB) and the CCD board (CCDB). - Causes: • MFP board (MFPB) • CCD board (CCDB)
- Troubleshooting Guides: 1. Check the connector between MFPB CN9-CCDB PJ3 for proper connection and correct as necessary. 2. Update the firmware. 3. Replace the CCD unit. 4. Replace MFPB.
- Code: CDF51, CDF71, CDFA1
- Description: • CDF51: ASIC image version failure (back side) • CDF71: ASIC image access failure (back side) • CDFA1: ASIC image error (back side)
Communication error is detected between the MFP board (MFPB) and the dual scan image processing board (DSIPB). - Causes: • MFP board (MFPB) • Dual scan image processing board (DSIPB)
- Troubleshooting Guides: 1. Check the connector between MFPB CN24-DSIPB CN1 for proper connection and correct as necessary. 2. Update the firmware. 3. Replace DSIPB. 4. Replace MFPB.
- Code: CE001 … CE009
- Description: • CE001: Abnormal message queue • CE003: Task error • CE004: Event error • CE005: Memory access error • CE006: Header access error • CE007: DIMM initialize error • CE009: Memory resource shortage error.
MFP board (MFPB) is faulty. - Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connectors on MFPB for proper connection and correct as necessary. 2. Replace MFPB.
- Code: CE002
- Description: Message and method parameter failure. MFP board (MFPB) is faulty.
- Causes: • MFP board (MFPB) • Hard disk (A) (HDD (A)) • Hard disk (B) (HDD (B): HD-524)
- Troubleshooting Guides: 1. Turn OFF the main power switch and turn it ON again, and conduct the following setting. [Service Mode] -> [System 1] -> [Initialization] – > [Clear All Data]. 2. Format the hard disk. 3. Replace the hard disk. (HDD (A) / HDD (B)) 4. Replace MFPB.
- Code: CE101
- Description: Browser finish detected. • The browser is automatically recovered (restarted) after the main body detected that the browser (separate process) has stopped with fault. • When the “Malfunction finish is detected over predetermined number of times” or “the browser task process is except in idle (printing, etc)”.
- Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connectors on MFPB for proper connection and correct as necessary. 2. Replace MFPB.
- Code: CE201
- Description: Transmission operation log storage fault. When the transmission log storage failed, it repeats retrial until transmission operation log is stored. The trouble is detected when the retrial failed for predetermined number of times.
- Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connectors on MFPB for proper connection and correct as necessary. 2. Replace MFPB.
- Code: CE301 … CE305
- Description: • CE301: Referring incorrect memory • CE302: Incorrect command • CE303: Finished due to error inside Qt library • CE304: Finished due to error outside Qt library • CE305: Program forced to stop
Error occurred with the process inside the MFP controller. - Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connectors on MFPB for proper connection and correct as necessary. 2. Replace MFPB. 3. Acquire the debug logs in [Service Mode] -> [Debug Settings] and analyze them.
- Code: CED01
- Description: The authentication application information does not exist in the hard disk/eMMC board in the enhanced server authentication state. With “Enhanced Server Authentication” set, no authentication application registration information is found in the hard disk or the eMMC board (eMMC).
- Causes: • eMMC board (eMMC) • Hard disk (A) (HDD (A)) • Hard disk (B) (HDD (B): HD-524)
- Troubleshooting Guides: 1. Turn OFF and ON the main power switch. 2. Check the connector between hard disk (A)-MFPB CN8, CN10 for proper connection and correct as necessary. 3. Check the connector between hard disk (B)-MFPB CN7, CN11 for proper connection and correct as necessary. 4. Check the connector from eMMC to MFPB for proper connection and correct as necessary. 5. Logically format the hard disk. 6. Replace the hard disk. (HDD (A) / HDD (B)) 7. If the above actions do not solve the problem, contact KM.
- Code: CEEE1, CEEE3
- Description: • CEEE1: MFP board (MSC) malfunction • CEEE3: MFP board (ENG) malfunction
MFP board (MFPB) is faulty. - Causes: MFP board (MFPB)
- Troubleshooting Guides: 1. Check the connectors on MFPB for proper connection and correct as necessary. 2. Replace MFPB.
- Code: CEEE2
- Description: Scanner section malfunction. A scanner part is faulty.
- Causes: • LED exposure unit • CCD board (CCDB) • Scanner drive board (SCDB)
- Troubleshooting Guides: 1. Check the connectors on CCDB or MFPB for proper connection and correct as necessary. 2. Replace SCDB 3. Replace the CCD unit.
- Code: D-1
- Description: Split line detect (front side). • While recovering from the power save mode or when the main power switch and power key are ON, it detects whether or not stain exist at the original reading glass when the DF is closed. This warning will be displayed if the original is set to DF when stain exist. • The thin line detection level and the warning display can be changed by [Service Mode] -> [System 2] -> [ADF Scan Glass Contamin. Set.] -> [Front Side].
- Causes: • Front side cleaning motor (M8) • Front side cleaning home sensor (PS18) • DF control board (DFCB)
- Troubleshooting Guides: 1. Wipe clean the glass surface of the original reading glass. 2. Check the front side glass cleaning roller unit for proper installation and correct if necessary. Clean the front side glass cleaning roller unit if dirty. 3. Select [Service Mode] -> [System 2] ->[ADF Scan Glass Contamin. Set.] -> [Front Side], and change the setting. 4. Check the DFCB connector for proper connection and correct as necessary. 5. M8 operation check 6. Replace the front side glass cleaning roller unit. 7. Replace DFCB.
- Code: D-3
- Description: Split line detect (back side). • While recovering from the power save mode or when the main power switch and power key are ON, it detects whether or not stain exist at the back side original scanning section (CIS) when the DF is closed. This warning will be displayed if the original is set to DF when stain exist. • The thin line detection level and the warning display can be changed by [Service Mode] -> [System 2] -> [ADF Scan Glass Contamin. Set.] -> [Back Side].
- Causes: • CIS module (CIS) • DF power supply (DFPU) • Dual scan image processing board (DSIPB)
- Troubleshooting Guides: 1. Wipe clean the CIS glass surface. 2. Check the back side glass cleaning roller unit for proper installation and correct if necessary. Clean the back side glass cleaning roller unit if dirty. 3. If there is a problem in the CIS module connection, correct the faulty connection. 4. Replace CIS. 5. Replace DFPU. 6. Replace DSIPB.
- Code: P-16, P-18
- Description: • PC charge cleaning trouble 1 <P-16> • PC charge cleaning trouble 2 <P-18>
<P-16> Charging cleaner home sensor is not transmitted even after the specified time has passed while the charging cleaner material or serrate electrode material is moving forward.
<P-18> Charging cleaner return sensor is not interrupted even after the specified time has passed when the charging cleaner material or serrate electrode material is moving forward. * Under the situation above occurs, control will be switched to the return operation after the warning is given. When the charging cleaner home sensor is not interrupted after the specified time has passed during the return operation, trouble code C-2101 will be given. - Causes: • Drum unit • Charge cleaning motor/K (M15) • Charging cleaner home sensor (PS43) • Charging cleaner return sensor (PS44) • PH relay board (PHRYB) • MFP board (MFPB)
- Troubleshooting Guides: 1. PS43 I/O check, sensor check 2. PS44 I/O check, sensor check 3. M15 operation check 4. Replace the drum unit. 5. Replace M15. 6. PHRYB F2 conduction check. 7. Replace PHRYB. 8. Replace MFPB.
- Code: P-27
- Description: Secondary transfer ATVC failure. An abnormal average value is detected during an adjustment of the second transfer ATVC value.
- Causes: • High voltage unit/2 (HV2) • MFP board (MFPB) • Image transfer entrance guide • 2nd transfer assy • Transfer belt unit
- Troubleshooting Guides: 1. Check the contact between the roller opposed to the 2nd transfer roller in the transfer belt unit and the grounding terminal. Clean the joint or correct if necessary. 2. Check the image transfer entrance guide for proper installation and correct if necessary. 3. Check that the spring does not come off during the pressure operation of the transfer roller and correct if necessary. 4. Check the contact at the joint of the 2nd transfer assy and HV2. Clean the joint or correct if necessary. 5. Replace the transfer belt unit. 6. Replace HV2. 7. MFPB F12E conduction check 8. Replace MFPB.
- Code: P-32
- Description: Heating roller temperature sensor/1 temperature detection failure (bizhub 808/758) Fusing belt temperature sensor/1 temperature detection failure (bizhub 958, bizhub PRO 958)
bizhub 958, bizhub PRO 958 • During warm up, the temperature detected by the fusing belt thermistor/1 exceeded the warm up complete temperature of the heating roller for over the predetermined value, and stayed for a predetermined period of time. • When the predetermined period of time had passed after the warm up became complete, detected temperature of the fusing belt thermistor/1 exceeded the temperature detected by the fusing belt temperature sensor/1 for over the predetermined value for more than the predetermined period of time. • While printing, temperature detected by the fusing belt thermistor/1 exceeded the temperature detected by the fusing belt temperature sensor/1 for more than the predetermined value for a predetermined period of time. • This warning indicates that condensation or dirt on the fusing belt temperature sensor/1 was detected, and the alternate temperature control is being conducted. With condensation, the warning is cleared when the condensation is detected to be removed. When the dirt on the sensor is detected, it is considered as a failure and the trouble code C-392A is issued.
bizhub 808/758: • During warm up, the temperature detected by the heating roller thermistor/1 exceeded the warm up complete temperature of the heating roller for over the predetermined value, and stayed for a predetermined period of time. • When the predetermined period of time had passed after the warm up became complete, detected temperature of the heating roller thermistor/1 exceeded the temperature detected by the heating roller temperature sensor/1 for over the predetermined value for more than the predetermined period of time. • While printing, temperature detected by the heating roller thermistor/1 exceeded the temperature detected by the heating roller temperature sensor/1 for more than the predetermined value for a predetermined period of time. • This warning indicates that condensation or dirt on the heating roller temperature sensor/1 was detected, and the alternate temperature control is being conducted. With condensation, the warning is cleared when the condensation is detected to be removed. When the dirt on the sensor is detected, it is considered as a failure and the trouble code C-392A is issued. - Causes: • Fusing unit • bizhub 808/758: Heating roller thermistor/1 (TH1) • bizhub 958, bizhub PRO 958: Fusing belt thermistor/1 (TH1) • bizhub 808/758: Heating roller temperature sensor/1 (TEMS1) • bizhub 958, bizhub PRO 958: Fusing belt temperature sensor/1 (TEMS1)
- Troubleshooting Guides: 1. Wipe the TEMS1 clean of dirt if any. <Cleaning procedure> • Clear away a dirt or a foreign object on the sensor with a cotton swab. • When a dirt is left even if you cleaned the sensor by above procedure, clear away a dirt or a foreign object on the sensor using a cotton swab dampened with the alcohol. And, wipe off the sensor with a dry cotton swab afterwards. 2. Check the connection of the fusing unit. 3. Replace the fusing unit.
- Code: P-5
- Description: IDC sensor failure. • When adjusting the IDC sensor, output voltage detected for all eight sample patterns are above 4.9 V. • When adjustment is complete, sensor’s output voltage with selected light intensity is under 1.0 V. • During image stabilization (gamma correction control), detected output value for IDC sensor did not go below threshold (half the value of what is detected by IDC sensor on the belt surface) for three consecutive times (position of the pattern end is not detected). • During image stabilization (gamma correction control), sensor’s output value for hyper 0 gradation after the primary approximation is half the detection level on the belt surface or under.
- Causes: • IDC sensor/Fr (IDCS/Fr) • MFP board (MFPB) • High voltage unit/1 (HV1) • Transfer belt unit
- Troubleshooting Guides: 1. Wipe clean the surface of the transfer belt with a soft cloth, if it is dirty. 2. Replace the transfer belt unit if the transfer belt is damaged. 3. Reinstall or reconnect IDCS/Fr, sensor shutter or connector, if it is installed or connected improperly. 4. Clean IDCS/Fr if it is dirty. 5. Check the HV1 connector for proper connection and correct as necessary. 6. Open/close the front door, run an image stabilization sequence, and select [State Confirmation] -> [Level History 1] to check the IDC value. If the value is 1.0 V or less, replace IDCS/Fr. • IDC1: IDCS/Fr 7. MFPB F12E, F13E or IC80E conduction check 8. Replace MFPB.
- Code: P-9
- Description: Drum/Development unit failure. All density readings taken from the density pattern produced on the transfer belt are 1.0 g/m2 (IDC sensor photo receiver output) or less during max. density adjustment (Vg/Vdc adjustment).
- Causes: • Drum unit • Developing unit • Transfer belt unit • High voltage unit/1 (HV1) • IDC sensor/Fr (IDCS/Fr) • MFP board (MFPB)
- Troubleshooting Guides: 1. Select [Imaging Process Adjustment] -> [Max Image Density Adj] and, if the setting value is negative, readjust. 2. Check the drive transmission portion of the drum unit and developing unit, and correct as necessary. 3. Clean the IDC sensor/Fr window if dirty. 4. Clean the contact of the drum unit connector and developing unit connector if dirty. 5. Check the HV1 connector for proper connection and correct as necessary. 6. Replace the drum unit. 7. Replace the developing unit. 8. Replace the transfer belt unit. 9. Replace HV1. 10. MFPB F12E or IC80E conduction check 11. Replace MFPB.
- Code: S-1
- Description: CCD gain adjustment failure. It is detected that the CCD clamp gain adjustment value is faulty.
- Causes: • LED exposure unit (LU201) • Scanner drive board (SCDB) • CCD board (CCDB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Correct the harness connection between CCDB and MFPB if faulty. 2. Check for possible extraneous light and correct as necessary. 3. Clean the lens, mirrors, CCD surface, and shading sheet if dirty. 4. Correct reflective mirror of the scanner if faulty, or change scanner mirror. 5. Replace the CCD unit. 6. Replace SCDB. 7. Replace MFPB.
- Code: S-2
- Description: CIS gain adjustment failure. It is detected that the CIS clamp gain adjustment value is faulty.
- Causes: • CIS module (CIS) • Dual scan image processing board (DSIPB) • MFP board (MFPB)
- Troubleshooting Guides: 1. Correct the harness connection between CIS and DSIPB if faulty. 2. Correct the harness connection between DSIPB and MFPB if faulty. 3. Check for possible extraneous light and correct as necessary. 4. Wipe clean the back side scanning glass surface and shading sheet. 5. Replace CIS. 6. Replace DSIPB. 7. Replace MFPB.
– Get more error code list with quick guide to fix printer product, click here
– About get help with reseting Epson inkpad or others, click here
– Get more information about Epson XP 15000 troubleshooting, click here
– Buy cheap key of Epson WIC Reset Tool, CLICK HERE
– Key Epson Adjustment Program, CLICK HERE
– Download Epson printer driver, CLICK HERE
– Download Epson XP-6100 Driver, Firmware and Manuals, CLICK HERE
Contact us to get support with Konica-Minolta bizhub Pro 958 Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.