[SOLVED] Quick fix Konica-Minolta Pro 950 list error codes
– Compatible Printer model: Konica-Minolta bizhub Pro 950
– Konica-Minolta bizhub Pro 950 Error Codes with quick guides:
- Code: C-0001
- Description: I/O initial communication check in the printer control board (PRCB). Main body drive serial input abnormality 1. Within a specified period of time after the power ON ACK, a serial data is not received from the main body drive unit.
- Causes: Printer control board (PRCB)
- Code: C-0002
- Description: Main body drive serial input abnormality 2. Within a specified period of time after the power ON ACK, a serial data is not received from the main body drive unit.
- Causes: Printer control board (PRCB)
- Code: C-0003
- Description: Main body drive serial input abnormality 3. Within a specified period of time after the power ON ACK, a serial data is not received from the main body drive unit.
- Causes: Printer control board (PRCB)
- Code: C-0004
- Description: Main body drive serial input abnormality 4. Within a specified period of time after the power ON ACK, a serial data is not received from the main body drive unit.
- Causes: Printer control board (PRCB)
- Code: C-0005
- Description: Main body drive serial input abnormality 5. Within a specified period of time after the power ON ACK, a serial data is not received from the main body drive board.
- Causes: Printer control board (PRCB)
- Code: C-0010
- Description: Communication error check between the printer engine system boards. Drive communication reception error detection abnormality. A reception error interruption occurs while in the drive board serial data reception. Or, due to the occurrence of the data checksum error/ID information error, a retransmission request is made 3 times and an error is detected on the 4th time.
- Causes: Confirmation of the wiring harness and the connector ADU drive board (ADUDB) LU drive board (LUDB) Printer control board (PRCB)
- Code: C-0020
- Description: Initial communication check between the ADU drive board (ADUDB)/ printer control board (PRCB). ADU drive serial input abnormality 1. Within a specified period of time after the ACK at the time of the main power switch (SW1) being turned ON, a serial data from ID = 0 of the ADUDB is not received.
- Causes: Confirmation of the wiring harness and the connector ADU drive board (ADUDB) Printer control board (PRCB)
- Code: C-0021
- Description: Communication error check between the ADU drive board (ADUDB)/ printer control board (PRCB). ADU drive serial input abnormality 2. Within a specified period of time after the ACK at the time of the main power switch (SW1) being turned ON, a serial data from ID = 7 of the ADUDB is not received.
- Causes: Confirmation of the wiring harness and the connector ADU drive board (ADUDB) Printer control board (PRCB)
- Code: C-0022
- Description: Initial communication check between the ADU drive board (ADUDB)/ printer control board (PRCB). ADU drive serial input abnormality 3. Within a specified period of time after the ACK at the time of the main power switch (SW1) being turned ON, a serial data from ID = 9 of the ADUDB is not received.
- Causes: Confirmation of the wiring harness and the connector ADU drive board (ADUDB) Printer control board (PRCB)
- Code: C-0101
- Description: An abnormal speed signal of the paper feed motor (M4) is checked. An error detection signal is detected twice in succession a specified period of time after M4 was turned ON (the first signal is ignored).
- Causes: Confirmation of the wiring harness and the connector Paper feed motor (M4) Printer control board (PRCB)
- Code: C-0102
- Description: An abnormal speed signal of the paper feed motor (M101) is checked. An error detection signal is detected twice in succession a specified period of time after M101 was turned ON (the first signal is ignored).
- Causes: Confirmation of the wiring harness and the connector Paper feed motor (M101) Printer control board (PRCB)
- Code: C-0104
- Description: The 24V power source for SD/CL in the printer control board (PRCB) is checked. At the start, an error detection signal (blowout of ICP for the solenoid/clutch) is detected, and an error detection signal (24V cut off) is also detected.
- Causes: Confirmation of the wiring harness and the connector Wiring harness earth fault Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-0105
- Description: The blowout of ICP for the SD/CL in the printer control board (PRCB) is checked. At the start, an error detection signal (blowout of ICP for the solenoid/clutch) is detected. However, an error detection signal (24V cut off) is not detected.
- Causes: Loose connection (on PRCB) Solenoid (SD5 to SD10, SD4, SD11) Clutch (CL3 to CL8, CL9, CL10) Wiring harness earth fault Printer control board (PRCB)
- Code: C-0210
- Description: The locking of the paper lift motor /1 (M19) is detected. An error detection signal of M19 is detected while M19 is ON.
- Causes: Tray 1 paper improperly loaded Tray 1 rear end restriction plate misaligned Confirmation of the wiring harness and the connector Paper lift motor /1 (M19) Upper limit sensor /1 (PS20) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-0211#
- Description: When the upper limit sensor /1 (PS20) is OFF, PS20 does not turn ON within a specified period of time after the paper lift motor / 1 (M19) turns ON for lifting operation. And at this time, an error detection signal (24V cut off) is detected.
- Causes: Tray 1 paper improperly loaded Tray 1 rear end restriction plate misaligned Confirmation of the wiring harness and the connector Paper lift motor /1 (M19) Upper limit sensor /1 (PS20) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-0212#
- Description: When the upper limit sensor /1 (PS20) is OFF, PS20 does not turn ON within a specified period of time after the paper lift motor / 1 (M19) turns ON for lifting operation. At this time, an error detection signal (blowout of ICP) is detected.
- Causes: Tray 1 paper improperly loaded Tray 1 rear end restriction plate misaligned Confirmation of the wiring harness and the connector Paper lift motor /1 (M19) Upper limit sensor /1 (PS20) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-0213#
- Description: When the upper limit sensor /1 (PS20) is OFF, PS20 does not turn ON within a specified period of time after the paper lift motor / 1 (M19) turns ON for lifting operation. And at this time, an error detection signal is not detected.
- Causes: Tray 1 paper improperly loaded Tray 1 rear end restriction plate misaligned Confirmation of the wiring harness and the connector Paper lift motor /1 (M19) Upper limit sensor /1 (PS20) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-0220
- Description: The locking of the paper lift motor /2 (M20) is detected. When M20 is ON, an error detection signal of the M20 is detected.
- Causes: Tray 2 paper improperly loaded Tray 2 rear end restriction plate misaligned Confirmation of the wiring harness and the connector Paper lift motor /2 (M20) Upper limit sensor /1 (PS21) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-0221#
- Description: When the upper limit sensor /2 (PS21) is OFF, PS21 does not turn ON within a specified period of time after the paper lift motor / 2 (M20) turns ON for lifting operation. And at this time, an error detection signal (24V cut off) is detected.
- Causes: Tray 2 paper improperly loaded Tray 2 rear end restriction plate misaligned Confirmation of the wiring harness and the connector Paper lift motor /2 (M20) Upper limit sensor /1 (PS21) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-0222#
- Description: When the upper limit sensor /2 (PS21) is OFF, PS21 does not turn ON within a specified period of time after the paper lift motor / 2 (M20) turns ON for lifting operation. And at this time, an error detection signal (blowout of ICP) is detected.
- Causes: Tray 2 paper improperly loaded Tray 2 rear end restriction plate misaligned Confirmation of the wiring harness and the connector Paper lift motor /2 (M20) Upper limit sensor /1 (PS21) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-0223#
- Description: When the upper limit sensor /2 (PS21) is OFF, PS21 does not turn ON within a specified period of time after the paper lift motor / 2 (M20) turns ON for lifting operation. And at this time, an error detection signal is not detected.
- Causes: Tray 2 paper improperly loaded Tray 2 rear end restriction plate misaligned Confirmation of the wiring harness and the connector Paper lift motor /2 (M20) Upper limit sensor /1 (PS21) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-0230
- Description: The locking of the paper lift motor /3 (M21) is detected. When M21 is ON, an error detection signal of the M21 is detected.
- Causes: Tray 3 paper improperly loaded Tray 3 rear end restriction plate misaligned Confirmation of the wiring harness and the connector Paper lift motor /3 (M21) Upper limit sensor /1 (PS22) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-0231#
- Description: When the upper limit sensor /3 (PS22) is OFF, PS22 does not turn ON within a specified period of time after the paper lift motor / 3 (M21) turns ON for lifting operation. And at this time, an error detection signal (24V cut off) is detected.
- Causes: Tray 3 paper improperly loaded Tray 3 rear end restriction plate misaligned Confirmation of the wiring harness and the connector Paper lift motor /3 (M21) Upper limit sensor /1 (PS22) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-0232#
- Description: When the upper limit sensor /3 (PS22) is OFF, PS22 does not turn ON within a specified period of time after the paper lift motor / 3 (M21) turns ON for lifting operation. And at this time, an error detection signal (blowout of ICP) is detected.
- Causes: Tray 3 paper improperly loaded Tray 3 rear end restriction plate misaligned Confirmation of the wiring harness and the connector Paper lift motor /3 (M21) Upper limit sensor /1 (PS22) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-0233#
- Description: When the upper limit sensor /3 (PS22) is OFF, PS22 does not turn ON within a specified period of time after the paper lift motor / 3 (M21) turns ON for lifting operation. And at this time, an error detection signal is not detected.
- Causes: Tray 3 paper improperly loaded Tray 3 rear end restriction plate misaligned Confirmation of the wiring harness and the connector Paper lift motor /3 (M21) Upper limit sensor /1 (PS22) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-0240
- Description: The locking of the paper lift motor (M100) is detected. When the paper lift motor (M100) is ON, an error detection signal of M100 is detected in succession for 1 second.
- Causes: Confirmation of the wiring harness and the connector Paper lift motor (M100) Lower limit sensor (PS101) Upper limit sensor (PS109) LU drive board (LUDB) DC power supply /2 (DCPS2)
- Code: C-0241#
- Description: When the upper limit sensor (PS109) or the lower limit sensor (PS101) is OFF, PS109 or PS101 does not turn ON within a specified period of time after the paper lift motor (M100) turns ON for its lifting or lowering operation. And at this time, an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector Paper lift motor (M100) Lower limit sensor (PS101) Upper limit sensor (PS109) LU drive board (LUDB) DC power supply /2 (DCPS2)
- Code: C-0242#
- Description: When the upper limit sensor (PS109) or the lower limit sensor (PS101) is OFF, PS109 or PS101 does not turn ON within a specified period of time after the paper lift motor (M100) turns ON for its lifting or lowering operation. At this time, an error detection signal is detected.
- Causes: Confirmation of the wiring harness and the connector Paper lift motor (M100) Lower limit sensor (PS101) Upper limit sensor (PS109) LU drive board (LUDB) DC power supply /2 (DCPS2)
- Code: C-0243#
- Description: When the upper limit sensor (PS109) or the lower limit sensor (PS101) is OFF, PS109 or PS101 does not turn ON within a specified period of time after the paper lift motor (M100) turns ON for its lifting or lowering operation. And at this time, an error detection signal is not detected.
- Causes: Confirmation of the wiring harness and the connector Paper lift motor (M100) Lower limit sensor (PS101) Upper limit sensor (PS109) LU drive board (LUDB) DC power supply /2 (DCPS2)
- Code: C-0251#
- Description: When the upper limit sensor / bypass (PS23) or the lower limit sensor /bypass (PS43) is OFF, PS23 or PS43 does not turn ON within a specified period of time after the bypass tray lift motor (M22) turns ON for its lifting or lowering operation. And at this time, an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector Bypass tray lift motor (M22) Upper limit sensor /Bypass (PS23) Lower limit sensor /Bypass (PS43) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-0252#
- Description: When the upper limit sensor / bypass (PS23) or the lower limit sensor /bypass (PS43) is OFF, PS23 or PS43 does not turn ON within a specified period of time after the bypass tray lift motor (M22) turns ON for its lifting or lowering operation. And at this time, an error detection signal (blowout of ICP) is detected.
- Causes: Confirmation of the wiring harness and the connector Bypass tray lift motor (M22) Upper limit sensor /Bypass (PS23) Lower limit sensor /Bypass (PS43) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-0253#
- Description: When the upper limit sensor / bypass (PS23) or the lower limit sensor /bypass (PS43) is OFF, PS23 or PS43 does not turn ON within a specified period of time after the bypass tray lift motor (M22) turns ON for its lifting or lowering operation. And at this time, an error detection signal is not detected.
- Causes: Confirmation of the wiring harness and the connector Bypass tray lift motor (M22) Upper limit sensor /Bypass (PS23) Lower limit sensor /Bypass (PS43) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-0301
- Description: The rotation of the conveyance suction fan (FM2) is checked, and the 24V power source is also checked. An abnormal FM2 EM signal condition occurs a specified period of time after FM2 is turned ON. This abnormal condition recurs even a specified period of time after FM12 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector Conveyance suction fan (FM2) AC drive board (ACDB) DC power supply /2 (DCPS2)
- Code: C-0302
- Description: The blowout of ICP for the conveyance suction fan (FM2) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM2 EM signal a specified period of time after FM2 is turned ON. This abnormal condition recurs even a specified period of time after FM2 is turned OFF and then turned ON, and an error detection signal (blowout of ICP) is detected.
- Causes: Confirmation of the wiring harness and the connector Conveyance suction fan (FM2) AC drive board (ACDB) DC power supply /2 (DCPS2)
- Code: C-0303
- Description: The rotation of the conveyance suction fan (FM2) is checked. An abnormal condition occurs with the FM2 EM signal a specified period of time after FM2 is turned ON. This abnormal condition recurs even a specified period of time after FM2 is turned OFF and then turned ON, and an error detection signal (24V cut off/ blowout of ICP) is not detected.
- Causes: Confirmation of the wiring harness and the connector Conveyance suction fan (FM2) AC drive board (ACDB) DC power supply /2 (DCPS2)
- Code: C-0304
- Description: Rotation of paper exit cooling fan /Lw1 (FM13), /Lw2 (FM14) is checked. An abnormal condition occurs with the FM13, FM14 EM signal a specified period of time after FM 13, FM14 is turned ON. This abnormal condition is detected even a specified period of time after FM13, FM14 is turned OFF and then turned ON.
- Causes: Confirmation of the wiring harness and the connector Paper exit cooling fan /Lw1 (FM13) Paper exit cooling fan /Lw2 (FM14) Printer control board (PRCB)
- Code: C-0305
- Description: Rotation of paper exit cooling fan /Up1 (FM15), /Up2 (FM17) is checked. An abnormal condition occurs with the FM15, FM17 EM signal a specified period of time after FM 15, FM17 is turned ON. This abnormal condition is detected even a specified period of time after FM15, FM17 is turned OFF and then turned ON.
- Causes: Confirmation of the wiring harness and the connector Paper exit cooling fan /Up1 (FM15) Paper exit cooling fan /Up2 (FM17) Printer control board (PRCB)
- Code: C-0306
- Description: The blowout of ICP for the paper exit cooling fans /Lw1 (FM13), / Lw2 (FM14), /Up1 (FM15) and / Up2 (FM17) is detected. An abnormal condition occurs either with the FM13 EM signal and the FM14 EM signal a specified period of time after FM13 and FM14 are turned ON or with the FM15 EM signal and the FM17 EM signal a specified period of time after FM15 and FM17 are turned ON. With this abnormal condition, an error detection signal (blowout of ICP) is detected and the door close is detected 5 times in succession.
- Causes: Confirmation of the wiring harness and the connector Paper exit cooling fan /Lw1 (FM13) Paper exit cooling fan /Lw2 (FM14) Paper exit cooling fan /Up1 (FM15) Paper exit cooling fan /Up2 (FM17) Printer control board (PRCB)
- Code: C-0307
- Description: The rotation of the developing cooling fan (FM19) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM19 EM signal a specified period of time after FM19 is turned ON. This abnormal condition recurs even a specified period of time after FM is turned OFF and then ON again, and an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector DC power supply /2 (DCPS2) Printer control board (PRCB)
- Code: C-0308
- Description: The blowout of ICP for the developing cooling fan (FM19) is checked. An abnormal condition occurs with the FM19 EM signal a specified period of time after FM19 is turned ON. This abnormal condition recurs even a specified period of time after FM is turned OFF and then ON again, and an error detection signal (blowout of ICP) is detected. However, an error detection signal (24V cut off) is not detected.
- Causes: Confirmation of the wiring harness and the connector DC power supply /2 (DCPS2) Printer control board (PRCB)
- Code: C-0309
- Description: The rotation of the developing cooling fan (FM19) is checked. An abnormal condition occurs with the FM19 EM signal a specified period of time after FM19 is turned ON. This abnormal condition recurs even a specified period of time after FM19 is turned OFF and then ON again, and an error detection signal (24V cut off/blowout of ICP) is not detected.
- Causes: Confirmation of the wiring harness and the connector DC power supply /2 (DCPS2) Printer control board (PRCB)
- Code: C-0310
- Description: Rotation of paper exit cooling fan /Lw1 (FM13), /Lw2 (FM14) is checked. An abnormal condition occurs with the FM13, FM14 EM signal a specified period of time after FM13, FM 14 is turned ON. This abnormal condition is detected even a specified period of time after FM13, FM14 is turned OFF and then ON again.
- Causes: Confirmation of the wiring harness and the connector Paper exit cooling fan /Lw1 (FM13) Paper exit cooling fan /Lw2 (FM14) Printer control board (PRCB)
Solve Konica-Minolta bizhub Pro 950 Error codes
- Code: C-0311
- Description: Rotation of paper exit cooling fan /Up1 (FM15), /Up2 (FM17) is checked. An abnormal condition occurs with the FM15, FM17 EM signal a specified period of time after FM15, FM 17 is turned ON. This abnormal condition is detected even a specified period of time after FM15, FM17 is turned OFF and then ON again.
- Causes: Confirmation of the wiring harness and the connector Paper exit cooling fan /Up1 (FM15) Paper exit cooling fan /Up2 (FM17) Printer control board (PRCB)
- Code: C-0401
- Description: The blowout of a 12V ICP for the AC drive board (ACDB) is checked. In the serial initial communication, a signal of the blowout of a 12V ICP (AC drive) is detected.
- Causes: Confirmation of the wiring harness and the connector AC drive board (ACDB)
- Code: C-0402
- Description: The blowout of a 5V ICP for the AC drive board (ACDB) is checked. In the serial initial communication, a signal of the blowout of a 5V ICP (AC drive) is detected.
- Causes: Confirmation of the wiring harness and the connector (ACDB) AC drive board (ACDB)
- Code: C-0403
- Description: The 12V power source in the printer control board (PRCB) is checked. An error detection signal of the 12V in PRCB is detected.
- Causes: Confirmation of the wiring harness and the connector Printer control board (PRCB) DC power supply /1 (DCPS1)
- Code: C-0410
- Description: 12V ICP blowout in the ADU drive board (ADUDB). A -5V ICP blowout signal and blowout of a 12V ICP signal are detected for the serial initial communication.
- Causes: Confirmation of the wiring harness and the connector ADU drive board (ADUDB) DC power supply /2 (DCPS2)
- Code: C-0411
- Description: 24V power source of the ADU drive board is checked. At the start, an error detection signal (blowout of ICP for the transfer exposure lamp/solenoid) is detected, and an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector Centering sensor (PS1) Transfer exposure lamp (EL2) ADU lock solenoid (SD1) Reverse/exit solenoid (SD2) Fusing solenoid (SD3) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
- Code: C-0412
- Description: At the start, an error detection signal (blowout of the ICP for the transfer exposure lamp/solenoid) is detected. However, an error detection signal (24V cut off) is not detected.
- Causes: Confirmation of the wiring harness and the connector Centering sensor (PS1) Transfer exposure lamp (EL2) ADU lock solenoid (SD1) Reverse/exit solenoid (SD2) Fusing solenoid (SD3) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
- Code: C-1001
- Description: Communication error.
- Causes: Confirmation of the wiring harness and the connector FS control board (FSCB) Printer control board (PRCB: main body)
- Code: C-1002
- Description: Start-up response error.
- Causes: Confirmation of the wiring harness and the connector FS control board (FSCB) Printer control board (PRCB: main body)
- Code: C-1012
- Description: Communication error.
- Causes: Confirmation of the wiring harness and the connector Printer control board (PRCB) Punch Controller PCB
- Code: C-1047
- Description: Communication abnormality between FS-PK.
- Causes: Confirmation of the wiring harness and the connector PK drive board (PDB) FS control board (FSCB)
- Code: C-1091
- Description: Communication error when the sub CPU in the FS control board (FSCB) is receiving data.
- Causes: Confirmation of the wiring harness and the connector FS control board (FSCB)
- Code: C-1092
- Description: Communication error when the main CPU in the FS control board (FSCB) is receiving data.
- Causes: Confirmation of the wiring harness and the connector FS control board (FSCB)
- Code: C-1101
- Description: The shift unit does not get to the shift position or the HP within a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the shift unit drive parts Shift roller home sensor (PS18) Shift roller motor (M2) FS control board (FSCB)
- Code: C-1102
- Description: After start-up of the main tray up/ down motor (M3) operation, the main tray upper limit sensor (PS2) or the stapler paper exit upper limit sensor (PS7) does not turn ON within a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the main tray drive parts Main tray upper limit sensor (PS2) Stapler paper exit upper limit sensor (PS7) Main tray up/down motor (M3) FS control board (FSCB)
- Code: C-1103
- Description: After start-up of the alignment motor /Up (M5) operation, the alignment home sensor /Up (PS8) does not turn OFF within a specified period of time. Or, it does not turn ON after being turned OFF.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the alignment plate drive parts Alignment plate home sensor /Up (PS8) Alignment motor /Up (M5) Relay board (RB) FS control board (FSCB)
- Code: C-1105
- Description: After start-up of the paper exit opening motor (M8) operation, the open/close operation is not completed within a specified period of time. (The paper exit opening home sensor (PS12) does not turn ON or OFF. )
- Causes: Confirmation of the wiring harness and the connector Confirmation of the exit opening drive parts Paper exit opening home sensor (PS12) Paper exit opening motor (M8) FS control board (FSCB)
- Code: C-1106
- Description: After start-up of the stapler movement motor (M11) operation, the stapler movement home sensor (PS11) does not turn OFF. Or, it does not turn ON after being turned OFF.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the stapler movement parts Stapler movement home sensor (PS11) Stapler movement motor (M11) Relay board (RB) FS control board (FSCB)
- Code: C-1107
- Description: Stapler rotation motor (M6) abnormality. (FS-611 only)
- Causes: Confirmation of the wiring harness and the connector Confirmation of the stapler rotation parts Stapler rotation motor (M6) Relay board (RB) FS control board (FSCB)
- Code: C-1108
- Description: Stapler /Rr rotation abnormality. (FS-611 only)
- Causes: Confirmation of the wiring harness and the connector Confirmation of the stapler / Rr rotation parts Stapler rotation home sensor (PS13) Relay board (RB) FS control board (FSCB)
- Code: C-1109
- Description: After start-up of the paper exit belt motor (M400) operation, the paper exit belt home sensor (PS9) does not turn ON within a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the driving parts of the conveyance belt Paper exit belt motor (M400) FS control board (FSCB)
- Code: C-1111
- Description: The stapler motor home sensor /Fr (PS31) does not turn ON within a specified period of time after the stapler motor /Fr (M14) starts operations. (FS-528) Within a specified period of time after the start-up of the clincher motor /Fr (M15) or stapler motor /Fr (M14) operation, the clincher home sensor / Fr (PS33) or the stapler home sensor /Fr (PS31) does not turn ON. (FS-611)
- Causes: Confirmation of the wiring harness and the connector Replacement of the stapler / Fr Relay board (RB) FS control board (FSCB)
- Code: C-1112
- Description: The stapler motor home sensor / Rr (PS30) does not turn ON within a specified period of time after the stapler motor /Rr (M9) starts operations. (FS-528) Within a specified period of time after the start-up of the clincher motor /Rr (M10) or stapler motor / Rr (M9) operation, the clincher home sensor /Rr (PS32) or the stapler home sensor /Rr (PS30) does not turn ON. (FS-611)
- Causes: Confirmation of the wiring harness and the connector Replacement of the stapler / Rr Relay board (RB) FS control board (FSCB)
- Code: C-1113
- Description: The clincher home sensor /Fr (PS33) does not turn ON within a specified period of time after the clincher motor /Fr (M15) starts operation. (FS-611)
- Causes: Confirmation of the wiring harness and the connector Replacement of the stapler / Fr Relay board (RB) FS control board (FSCB)
- Code: C-1114
- Description: The clincher home sensor /Rr (PS32) does not turn ON within a specified period of time after the clincher motor /Rr (M10) starts operation. (FS-611)
- Causes: Confirmation of the wiring harness and the connector Replacement of the stapler / Rr Relay board (RB) FS control board (FSCB)
- Code: C-1115
- Description: Within a specified period of time after the start-up of the FS conveyance motor (M1) operation, the motor does not get to the predetermined speed.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the conveyance drive parts FS conveyance motor (M1) FS control board (FSCB)
- Code: C-1121
- Description: After the saddle stitching stopper motor (M18) starts the home position detection operation, the saddle stitching stopper home sensor (PS23) does not turn ON within a specified period of time. (FS-611 only)
- Causes: Confirmation of the wiring harness and the connector Confirmation of the saddle stitcher stopper drive parts Saddle stitching stopper home sensor (PS23) Saddle stitching stopper motor (M18) Relay board (RB) FS control board (FSCB)
- Code: C-1122
- Description: After the alignment motor /Lw (M16) starts the home position detection operation, the alignment plate home sensor /Lw (PS24) does not turn ON within a specified period of time. (FS-611 only)
- Causes: Confirmation of the wiring harness and the connector Confirmation of the alignment plate /Lw drive parts Alignment plate home sensor /Lw (PS24) Alignment motor /Lw (M16) Relay board (RB) FS control board (FSCB)
- Code: C-1125
- Description: After the folding blade motor (M19) starts the home position detection operation, the folding blade home sensor /Lw (PS22) does not turn ON within a specified period of time. (FS-611 only)
- Causes: Confirmation of the wiring harness and the connector Confirmation of the folding blade drive parts Folding blade home sensor (PS22) Folding blade motor (M19) Relay board (RB) FS control board (FSCB)
- Code: C-1126
- Description: After start-up of the folding conveyance motor (M20) operation, the M20 does not get to the predetermined speed within a specified period of time. (FS-611 only)
- Causes: Confirmation of the wiring harness and the connector Confirmation of the folding transfer drive parts Folding transfer motor (M20) Relay board (RB) FS control board (FSCB)
- Code: C-1131
- Description: After start-up of the conveyance motor (M101) operation, the M101 does not get to the predetermined speed within a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the trimming conveyance drive parts Conveyance motor (M101) TU drive board (TUDB)
- Code: C-1132
- Description: After the blade motor (M102) starts the home position detection operation, the blade home switch (MS101) does not turn ON within a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the blade drive parts Blade home switch (MS101) Blade motor (M102) TU drive board (TUDB)
- Code: C-1133
- Description: After the stopper motor (M103) starts the home position detection operation, the stopper home sensor (PS103) does not turn ON within a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the stopper drive parts Stopper home sensor (PS103) Stopper motor (M103) TU drive board (TUDB)
- Code: C-1134
- Description: After the stopper release motor (M104) starts the home position detection operation, the stopper release home sensor (PS104) does not turn ON within a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the stopper release drive parts Stopper release home sensor (PS104) Stopper release motor (M104) TU drive board (TUDB)
- Code: C-1135
- Description: After the press motor (M105) starts the home position detection operation, the press home sensor (PS105) does not turn ON within a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the press drive parts Press home sensor (PS105) Press motor (M105) TU drive board (TUDB)
- Code: C-1136
- Description: After the pusher motor (M107) starts the home position detection operation, the pusher home sensor (PS112) does not turn ON within a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the pusher drive parts Pusher home sensor (PS112) Pusher motor (M107) TU drive board (TUDB)
- Code: C-1137
- Description: After the holder motor (M106) starts the home position detection operation, the upper limit sensor (PS110) does not turn ON within a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the holder drive parts Upper limit sensor (PS110) Holder motor (M106) TU drive board (TUDB)
- Code: C-1141
- Description: After start-up of the tray lift motor /Lw (M202) operation, the tray lower limit sensor /Lw (PS210) does not turn ON within a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the tray /Lw drive parts Tray lower limit sensor /Lw (PS210) Tray lift motor /Lw (M202) PI drive board (PIDB) FS control board (FSCB)
- Code: C-1142
- Description: After start-up of the tray lift motor /Up (M201) operation, the tray upper limit sensor /Up (PS204) does not turn ON within a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the tray /Up drive parts Tray upper limit sensor /Up (PS204) Tray lift motor /Up (M201) PI drive board (PIDB) FS control board (FSCB)
- Code: C-1143
- Description: After the conveyance motor (M203) turns ON, the M203 does not get to the predetermined speed within a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Transfer motor (M203) PI drive board (PIDB) FS control board (FSCB)
- Code: C-1144
- Description: After the punch shift motor (M802) starts the home position search, the punch shift home sensor (PS803) does not turn ON even when a specified period of time elapses.
- Causes: Confirmation of the wiring harness and the connector Punch shift home sensor (PS803) Punch shift motor (M802) Punch drive board (PDB) FS control board (FSCB)
- Code: C-1152
- Description: After the 1st stopper motor (M2) starts the home position search, the 1st stopper home sensor (PS3) does not turn ON even when a specified period of time elapses.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the 1st stopper drive parts 1st stopper home sensor (PS3) 1st stopper motor (M2) ZU control board (ZUCB)
- Code: C-1153
- Description: After the 2nd stopper motor (M3) starts the home position search, the 2nd stopper home sensor (PS4) does not turn ON even when a specified period of time elapses.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the 2nd stopper drive parts 2nd stopper home sensor (PS4) 2nd stopper motor (M3) ZU control board (ZUCB)
- Code: C-1154
- Description: The punch home sensor (PS801) does not turn OFF within a specified period of time after the punch motor (M801) starts operation.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the punch drive parts Punch home sensor (PS801) Punch motor (M801) Punch drive board (PDB) FS control board (FSCB)
- Code: C-1155
- Description: After the punch shift motor (M5) starts the home position search, the punch shift home sensor (PS5) does not turn ON even when a specified period of time elapses.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the punch shift drive parts Punch shift home sensor (PS5) Punch shift motor (M5) ZU control board (ZUCB)
- Code: C-1157
- Description: After the punch motor (M4) turns on, the punch operation is not completed even when a specified period of time elapses. (The punch home sensor (PS6) does not turn OFF, or it does not turn ON after being turned OFF. )
- Causes: Confirmation of the wiring harness and the connector Confirmation of the punch drive parts Punch home sensor (PS6) Punch clutch (CL1) Punch motor (M4) ZU control board (ZUCB)
- Code: C-1158
- Description: After the punch switching motor (M8) starts the home position search, the punch switching switch (MS2) does not turn ON even when a specified period of time elapses.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the punch switchover drive parts Punch switchover switch (MS2) Punch switchover motor (M8) ZU control board (ZUCB)
- Code: C-1181
- Description: After the gate motor (M12) starts the home position search, the gate home sensor (PS16) does not turn ON even when a specified period of time elapses.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the gate drive parts Gate home sensor (PS16) Gate motor (M12) FS control board (FSCB)
- Code: C-1356
- Description: A specified period of time after the conveyance motor cooling fan (M10) is turned on, the EM signal of the M10 gets into an abnormal condition.
- Causes: Confirmation of the wiring harness and the connector Conveyance motor cooling fan (M10) ZU control board (ZUCB)
- Code: C-2101
- Description: When the charge cleaning home sensor (PS41) is OFF with the main power switch (SW1) ON, PS41 does not turn ON within a specified period of time after the charge cleaning motor (M23) turns ON for home position research operation (return operation). At this time, an error detection signal (blowout of ICP) is not detected. PS41 does not turn OFF within a specified period of time after the reverse operation (return operation) is started. At this time, an error detection signal (blowout of ICP) is not detected. It is checked that the time for the M23 operations is over. The charge cleaning limit sensor (PS42) does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS41 being OFF. Or, PS41 does not turn ON within a specified period of time after PS42 turns ON.
- Causes: Confirmation of the wiring harness and the connector Charge cleaning motor (M23) Charge cleaning home sensor (PS41) Charge cleaning limit sensor (PS42) Printer control board (PRCB)
- Code: C-2102
- Description: The blowout of ICP for the charge cleaning motor (M23) in the printer control board (PRCB) is checked. When the charge cleaning home sensor (PS41) is OFF with the main power switch (SW1) ON, PS41 does not turn ON within a specified period of time after the M23 turns ON for home position research operation (return operation). And at this time, an error detection signal (blowout of ICP) is detected. PS41 does not turn OFF within a specified period of time after the reverse operation (return operation) is started. And at this time, an error detection signal (blowout of ICP) is detected. The charge cleaning limit sensor (PS42) does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS41 being OFF. Or, PS41 does not turn ON within a specified period of time after PS42 turns ON. At this time, an error detection signal (blowout of ICP) is detected.
- Causes: Confirmation of the wiring harness and the connector Charge cleaning motor (M23) Charge cleaning home sensor (PS41) Charge cleaning limit sensor (PS42) Printer control board (PRCB)
- Code: C-2103
- Description: The locking of the charge cleaning motor (M23) is detected. A motor lock signal is detected while moving from the charge cleaning limit sensor (PS42) side to the charge cleaning home sensor (PS41) side, and after a retry operation, a fifth motor lock signal is detected.
- Causes: Confirming the operation of the charging corona cleaning member Confirmation of the wiring harness and the connector Charge cleaning motor (M23) Charge cleaning home sensor (PS41) Charge cleaning limit sensor (PS42) Printer control board (PRCB)
- Code: C-2104
- Description: It is checked that the operations of the transfer/separation cleaning motor (M18) are over. When the transfer/separation cleaning home sensor (PS11) is OFF with the main power switch (SW1) ON, PS11 does not turn ON within a specified period of time after the M18 turns ON for a home position research operation (return operation). At this time, an error detection signal (blowout of ICP) is not detected. PS11 does not turn OFF within a specified period of time after the reverse operation (return operation) is started. At this time, an error detection signal (blowout of ICP) is not detected. It is checked that the operations of the M18 are over. The transfer/ separation cleaning limit sensor (PS12) does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS11 being OFF. Or, PS11 does not turn ON within a specified period of time after PS12 turns ON. At this time, an error detection signal (blowout of ICP) is not detected.
- Causes: Confirmation of the wiring harness and the connector Transfer/separation cleaning motor (M18) Transfer/separation cleaning home sensor (PS11) Transfer/separation cleaning limit sensor (PS12) ADU drive board (ADUDB)
- Code: C-2106
- Description: The locking of the transfer/separation cleaning motor (M18) is detected. Motor lock signals are detected while moving from the transfer/separation limit sensor (PS12) side to the transfer/separation home sensor (PS11) side, and after a retry operation, a fifth motor lock signal is detected.
- Causes: Confirmation of the transfer/ separation cleaning member Confirmation of the wiring harness and the connector Transfer/separation cleaning motor (M18) Transfer/separation cleaning home sensor (PS11) Transfer/separation cleaning limit sensor (PS12) ADU drive board (ADUDB)
- Code: C-2110
- Description: It is checked that the home position search time of the transfer assist motor (M25) is out. When the transfer assist home sensor (PS64) is turned OFF, PS64 is not turned ON a specified period of time after the home position search starts operation.
- Causes: Confirmation of the wiring harness and the connector Transfer assist motor (M25) Transfer assist home sensor (PS64) ADU drive board (ADUDB) DC power supply /1 (DCPS1) Power supply cooling fan /1 (FM30) Power supply cooling fan /2 (FM31)
- Code: C-2111
- Description: While the transfer assist motor (M25) is in operation, an error is detected. An error is detected of the transfer assist motor (M25) while in the print operation.
- Causes: Confirmation of the wiring harness and the connector Transfer assist motor (M25) Transfer assist home sensor (PS64) ADU drive board (ADUDB) DC power supply /1 (DCPS1) Power supply cooling fan /1 (FM30) Power supply cooling fan /2 (FM31)
- Code: C-2201
- Description: The speed error signal of the toner bottle motor (M15) is checked. An error detection signal is detected twice in succession a specified period of time after M15 turns ON (the first signal is ignored).
- Causes: Confirmation of the wiring harness and the connector Toner bottle motor (M15) Printer control board (PRCB)
- Code: C-2202
- Description: The speed error signal of the developing motor (M3) is checked. Since an error detection signal is detected a second after M3 turns ON, turn OFF M3 for a specified period of time. Then, an error detection signal is detected again a specified period of time after it is turned ON again.
- Causes: Confirmation of the wiring harness and the connector Developing motor (M3) Printer control board (PRCB)
- Code: C-2203
- Description: The locking of the blade motor (M14) is detected. The error detection signal (over current) of M14 is detected.
- Causes: Confirmation of the wiring harness and the connector Blade motor (M14) Printer control board (PRCB)
- Code: C-2204
- Description: It is checked that the movement of the blade motor (M14) is not completed, and the 24V power source is also checked. The drum READY1 signal (READY condition) cannot be detected within a specified period of time after the drum motor (M2) turns ON. Or, the drum READY1 signal (READY release condition) cannot be detected within a specified period of time after M2 turns OFF. At this time, an error detection signal (24V cut out) is detected.
- Causes: Confirmation of the wiring harness and the connector Blade sensor /1 (PS30) Blade sensor /2 (PS31) Blade motor (M14) Drum motor (M2) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-2205
- Description: The blowout of ICP for the blade motor (M14) in the printer control board (PRCB) is checked. The drum READY1 signal (READY condition) cannot be detected within a specified period of time after the drum motor (M2) turns ON. Or, the drum READY1 signal (READY release condition) cannot be detected within a specified period of time after M2 turns OFF. At this time, the error detection signal (blowout of ICP) of M14 is detected.
- Causes: Confirmation of the wiring harness and the connector Blade sensor /1 (PS30) Blade sensor /2 (PS31) Blade motor (M14) Drum motor (M2) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-2206
- Description: It is checked that the movement of the blade motor (M14) is not completed. The drum READY1 signal (READY condition) cannot be detected within a specified period of time after the drum motor (M2) turns ON. Or, the drum READY1 signal (READY release condition) cannot be detected within a specified period of time after M2 turns OFF. At this time, an error detection signal is not detected.
- Causes: Confirmation of the wiring harness and the connector Blade sensor /1 (PS30) Blade sensor /2 (PS31) Blade motor (M14) Drum motor (M2) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-2207
- Description: It is checked that the movement of the blade motor (M14) is not completed, and 24V power source is also checked. The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal (24V cut out) is detected.
- Causes: Confirmation of the wiring harness and the connector Blade sensor /1 (PS30) Blade sensor /2 (PS31) Blade motor (M14) Drum motor (M2) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-2208
- Description: The blowout of ICP for the blade motor (M14) in the printer control board (PRCB) is checked. The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, the error detection signal (blowout of ICP) of M14 is detected.
- Causes: Confirmation of the wiring harness and the connector Blade sensor /1 (PS30) Blade sensor /2 (PS31) Blade motor (M14) Drum motor (M2) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-2209
- Description: It is checked that the movement of the blade motor (M14) is not completed. The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal is not detected.
- Causes: Confirmation of the wiring harness and the connector Blade sensor /1 (PS30) Blade sensor /2 (PS31) Blade motor (M14) Drum motor (M2) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-2210
- Description: It is checked that the drum motor (M2) does not start. The drum READY2 signal (READY signal) is not detected within a specified period of time after M2 turns ON.
- Causes: Confirmation of the wiring harness and the connector Drum motor (M2) Printer control board (PRCB)
- Code: C-2211
- Description: The blowout of ICP for the toner supply motor (M11) in the printer control board (PRCB) is checked. An error detection signal (blowout of ICP) is detected when M11 turns ON.
- Causes: Confirmation of the wiring harness and the connector Toner supply motor (M11) Printer control board (PRCB)
- Code: C-2221
- Description: When the recycle cut motor (M24) is turned ON, an error detection signal is detected twice in a row within a specified period of time. (An error detection signal on the first time is ignored.)
- Causes: Confirmation of the wiring harness and the connector Recycle cut motor (M24) Recycle cut drive board (RCDB) Printer control board (PRCB)
- Code: C-2250
- Description: It is detected that the waste toner amount exceeds 80% of the toner collection box At this time, DIPSW5-0 is 0 and the operations of all the job, including the reservation, are completed.
- Causes: Waste toner recycle box
- Code: C-2401
- Description: The temperature of the drum temperature sensor (TH5) detected a specified period of time after the main power switch (SW1) is turned ON is -3°C or lower, and also, the drum temperature after a specified period of time is -3°C or lower.
- Causes: Confirmation of the wiring harness and the connector Drum temperature sensor (TH5) Printer control board (PRCB)
- Code: C-2402
- Description: When the main power switch (SW1) turns ON with the fusing temperature below 50°C, the detected temperature of the drum temperature sensor (TH5) is more than 52°C, and when the detected temperature is above 52°C after a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Drum temperature sensor (TH5) Printer control board (PRCB)
- Code: C-2403
- Description: The erase lamp (EL1) is unconnected.
- Causes: Confirmation of the wiring harness and the connector Erase lamp (EL1) Printer control board (PRCB)
- Code: C-2701
- Description: A charge leak is detected. After a charge error detection signal is detected while in the charge ON, up to 5 charge ON/OFF operations occur in succession.
- Causes: Confirmation of the charger power feeding contact Confirmation of the wiring harness and the connector High voltage unit /1 (HV1) Printer control board (PRCB)
- Code: C-2702
- Description: A transfer leak is detected. After a transfer error detection signal is detected while in the transfer ON, up to 5 transfer ON/OFF operations occur in succession.
- Causes: Confirmation of the transfer/ separation charger power feeding contact Confirmation of the wiring harness and the connector High voltage unit /2 (HV2) Printer control board (PRCB) ADU drive board (ADUDB)
- Code: C-2703
- Description: A separation leak is detected. After a separation error detection signal is detected while in the separation ON, up to 5 separation ON/OFF operations occur in succession.
- Causes: Confirmation of the transfer/ separation charger power feeding contact Confirmation of the wiring harness and the connector High voltage unit /2 (HV2) Printer control board (PRCB) ADU drive board (ADUDB)
- Code: C-2704
- Description: The error detection signal (blowout of a 24V ICP) of the high voltage unit /2 (HV2) is detected.
- Causes: Confirmation of the wiring harness and the connector High voltage unit /2 (HV2) ADU drive board (ADUDB)
- Code: C-2801
- Description: The dirt correction of the sensor is not completed. While in the maximum density correction, the dirt correction of the IDC sensor is not sufficient. When this condition is detected 10 times in succession, the error code is displayed.
- Causes: Cleaning of the IDC sensor Confirmation of the wiring harness and the connector IDC sensor board (IDCB) Printer control board (PRCB)
- Code: C-2802#
- Description: The maximum density correction is not completed. While in the maximum density correction, the number of rotations of the developing roller gets to the maximum.
- Causes: Cleaning of the IDC sensor Confirmation of the wiring harness and the connector IDC sensor board (IDCB) Developing motor (M3) Printer control board (PRCB) Overall control board (OACB) Write unit
- Code: C-2803#
- Description: The IDC sensor board (IDCB) output abnormality. While in the maximum density correction, a patch for control is not output. (No output is made from the IDCS. )
- Causes: Cleaning of the IDC sensor Confirmation of the wiring harness and the connector IDC sensor board (IDCB) Developing motor (M3) Printer control board (PRCB) Overall control board (OACB) Write unit
- Code: C-2804#
- Description: The dirt correction of the sensor is not completed. While in gamma correction, the dirt correction of the IDC sensor is not sufficient. When C-2804 or C- 2807 is detected 10 times in succession, the error code is displayed.
- Causes: Cleaning of the IDC sensor Confirmation of the wiring harness and the connector IDC sensor board (IDCB) Developing motor (M3) Printer control board (PRCB) Overall control board (OACB) Write unit
- Code: C-2805#
- Description: The IDC sensor board (IDCB) output abnormality. While in the gamma correction, a patch for control is not output. (No output is made from the IDCB. )
- Causes: Cleaning of the IDC sensor Confirmation of the wiring harness and the connector IDC sensor board (IDCB) Developing motor (M3) Printer control board (PRCB) Overall control board (OACB) Write unit
- Code: C-2806#
- Description: The gamma correction data is defective. The gamma correction output is abnormal. A regression error when carrying out a gamma curve operation while in the gamma correction.
- Causes: Cleaning of the IDC sensor Confirmation of the wiring harness and the connector IDC sensor board (IDCB) Developing motor (M3) Printer control board (PRCB) Overall control board (OACB) Write unit
- Code: C-2807#
- Description: The dirt correction of the sensor is not completed. While in the dot diameter correction, the dirt correction of the IDC sensor is not sufficient. When C-2804 or C- 2807 is detected 10 times in succession, the error code is displayed.
- Causes: Cleaning of the IDC sensor Confirmation of the wiring harness and the connector IDC sensor board (IDCB) Developing motor (M3) Printer control board (PRCB) Overall control board (OACB) Write unit
- Code: C-2808#
- Description: Correction abnormality. While in the dot diameter correction, the correction is terminated with an abnormal value.
- Causes: Cleaning of the IDC sensor Confirmation of the wiring harness and the connector IDC sensor board (IDCB) Developing motor (M3) Printer control board (PRCB) Overall control board (OACB) Write unit
- Code: C-2809#
- Description: Drum potential sensor (DPS) output abnormality. While in the 0V check of the DPS, more than 100V of the drum surface potential is detected more than 5 times. When this condition is detected 5 times in succession, the error code is displayed.
- Causes: Confirmation of the wiring harness and the connector Drum potential sensor board (DPSB) Drum potential sensor (DPS) Printer control board (PRCB)
- Code: C-2810
- Description: Drum potential sensor (DPS) output abnormality. While in the drum potential correction, a patch for control is not output with the V1 getting to more than 350V. When this condition is detected 5 times in succession, the error code is displayed.
- Causes: Confirmation of the wiring harness and the connector Drum potential sensor board (DPSB) Drum potential sensor (DPS) Printer control board (PRCB)
- Code: C-2811
- Description: The data is defective. While in the drum potential correction, no convergence is obtained even after correction is made more than 10 times. When this condition is detected 5 times in succession, the error code is displayed.
- Causes: Confirmation of the wiring harness and the connector Drum potential sensor board (DPSB) Drum potential sensor (DPS) Printer control board (PRCB)
- Code: C-2812#
- Description: Auto adjustment monitor value abnormality. No convergence is made in the auto adjustment of the transfer current.
- Causes: Confirmation of the transfer/ separation charger power feeding contact Confirmation of the wiring harness and the connector High voltage unit /2 (HV2) Printer control board (PRCB) ADU drive board (ADUDB)
- Code: C-2813#
- Description: Auto adjustment monitor value abnormality. No convergence is made in the auto adjustment of the separation (AC) current.
- Causes: Confirmation of the transfer/ separation charger power feeding contact Confirmation of the wiring harness and the connector High voltage unit /2 (HV2) Printer control board (PRCB) ADU drive board (ADUDB)
- Code: C-2814#
- Description: Auto adjustment monitor value abnormality. No convergence is made in the auto adjustment of the separation (DC) current.
- Causes: Confirmation of the transfer/ separation charger power feeding contact Confirmation of the wiring harness and the connector High voltage unit /2 (HV2) Printer control board (PRCB) ADU drive board (ADUDB)
- Code: C-2815#
- Description: Auto adjustment monitor value abnormality. No convergence is made in the auto adjustment of the developing bias.
- Causes: Confirmation of the charger power feeding contact Confirmation of the wiring harness and the connector High voltage unit /1 (HV1) Printer control board (PRCB)
- Code: C-3101
- Description: The blowout of ICP for the web motor (M16) in the printer control board (PRCB) is checked, and the 24V power source is also checked. When M16 turn ON from OFF, error detection signals (blowout of ICP and the 24V cut off) are detected.
- Causes: Confirmation of the wiring harness and the connector Web motor (M16) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-3102
- Description: The blowout of ICP for the web motor (M16) in the printer control board (PRCB) is checked. When M16 turns ON from OFF, the blowout of ICP abnormality is detected with a 24V down signal normal.
- Causes: Confirmation of the wiring harness and the connector Web motor (M16) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-3301
- Description: The rotation of the fusing fan /1 (FM1) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM1 EM signal a specified period of time after FM1 is turned ON. This abnormal condition recurs even a specified period of time after FM1 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector Fusing fan /1 (FM1) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
- Code: C-3302
- Description: Rotation of the fusing fan /1 (FM1) is checked. An abnormal condition occurs with the FM1 EM signal a specified period of time after FM1 is turned ON. This abnormal condition recurs even a specified period of time after FM1 is turned OFF and then turned ON, and an error detection signal (24V cut off/ blowout of ICP) is not detected.
- Causes: Confirmation of the wiring harness and the connector Fusing fan /1 (FM1) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
- Code: C-3303#
- Description: When the print is completed, the fusing fan /1 (FM1) EM signal gets into an abnormal condition.
- Causes: Confirmation of the wiring harness and the connector Fusing fan /1 (FM1) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
- Code: C-3304
- Description: The rotation of the fusing fan /2 (FM4) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM4 EM signal a specified period of time after FM4 is turned ON. This abnormal condition recurs even a specified period of time after FM4 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector Fusing fan /2 (FM4) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
- Code: C-3305
- Description: Rotation of the fusing fan /2 (FM4) is checked. An abnormal condition occurs with the FM4 EM signal a specified period of time after FM4 is turned ON. This abnormal condition recurs even a specified period of time after FM4 is turned OFF and then ON again, and an error detection signal (24V cut off) is not detected.
- Causes: Confirmation of the wiring harness and the connector Fusing fan /2 (FM4) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
- Code: C-3306
- Description: When the print is completed, the fusing fan /2 (FM4) EM signal gets into an abnormal condition.
- Causes: Confirmation of the wiring harness and the connector Fusing fan /2 (FM4) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
- Code: C-3501
- Description: Fusing roller /Up high temperature detection (software). TH1 detects a temperature of 235°C or above 5 times in a specified period of time. Or, the fusing temperature sensor /2 (TH2) detects a temperature of 240°C or above.
- Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 1 (TH1) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB)
- Code: C-3502
- Description: Fusing heating roller high temperature abnormality (software). TH3 detects a temperature of 230°C or above 5 times in a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB)
- Code: C-3503
- Description: Fusing roller /Up high temperature abnormality (hardware). An abnormal condition is detected with the fusing error detection signal 1.
- Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 1 (TH1) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB)
- Code: C-3504
- Description: Fusing heating roller high temperature abnormality (hardware). An abnormal condition is detected with the fusing error detection signal 4.
- Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB)
- Code: C-3801
- Description: Fusing roller /Up low temperature abnormality (software). TH1 does not get to 75°C when a specified period of time has elapsed after the main switch (SW1) is turned ON for the fusing ON control.
- Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 1 (TH1) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB)
- Code: C-3802
- Description: Fusing heating roller low temperature abnormality (software). TH3 does not get to 50°C when a specified period of time has elapsed after the main switch (SW1) is turned ON for the fusing ON control.
- Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB)
- Code: C-3901
- Description: Fusing roller /Up sensor abnormality (software). TH1 detects a temperature of 230°C or above 30 times in a row in a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 1 (TH1) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB)
- Code: C-3902
- Description: Fusing heating roller sensor abnormality (software). TH3 detects a temperature of 220°C or above 30 times in a row in a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB)
- Code: C-3903
- Description: Fusing roller /Up sensor abnormality (hardware). The output voltage of the TH1 is detected as a low temperature abnormality (- 6°C or lower) in the comparator circuit.
- Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 1 (TH1) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB)
- Code: C-3904
- Description: Fusing heating roller sensor abnormality (hardware). The output voltage of the TH3 is detected as a low temperature abnormality (-6°C or lower) in the comparator circuit.
- Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB)
- Code: C-3905
- Description: Fusing roller /Up abnormality detection (hardware). The output voltage of the TH2 is detected as a low temperature (-6°C or lower) or high temperature (240.5°C or higher) abnormality in the comparator circuit.
- Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 2 (TH2) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB)
- Code: C-3906
- Description: Fusing heating roller abnormality detection (hardware). The output voltage of the TH4 is detected as a low temperature (-6°C or lower) or high temperature (240.5°C or higher) abnormality in the comparator circuit.
- Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 4 (TH4) Fusing heater lamp / 3 (L3) Printer control board (PRCB) AC drive board (ACDB)
- Code: C-4101
- Description: When the speed of the polygon motor (M17) is being switched, a speed lock signal is not detected within a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Write unit (Polygon motor drive board (PMDB) Polygon motor (M17) ) DC power supply /2 (DCPS2)
- Code: C-4301
- Description: The rotation of the write unit cooling fan /1 (FM5) is checked, and 24V power source is also checked. An abnormal condition occurs with the FM5 EM signal a specified period of time after FM5 turns ON. This abnormal condition recurs even a specified period of time after FM5 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector Write unit cooling fan /1 (FM5) AC drive board (ACDB) DC power supply /2 (DCPS2)
- Code: C-4302
- Description: The blowout of ICP for the write unit cooling fan /1 (FM5) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM5 EM signal a specified period of time after FM5 turns ON. This abnormal condition recurs even a specified period of time after FM5 is turned OFF and then turned ON, and an error detection signal (blowout of ICP) is detected.
- Causes: Confirmation of the wiring harness and the connector Write unit cooling fan /1 (FM5) AC drive board (ACDB) DC power supply /2 (DCPS2)
- Code: C-4303
- Description: The rotation of the write unit cooling fan /1 (FM5) is checked. An abnormal condition occurs with the FM5 EM signal a specified period of time after FM5 turns ON. This abnormal condition recurs even a specified period of time after FM5 is turned OFF and then turned ON, and an error detection signal (24V cut off/ blowout of ICP) is not detected.
- Causes: Confirmation of the wiring harness and the connector Write unit cooling fan /1 (FM5) AC drive board (ACDB) DC power supply /2 (DCPS2)
- Code: C-4304
- Description: When the print is started, an error detection signal of the writing section cooling fan /1 (FM5) is detected.
- Causes: Confirmation of the wiring harness and the connector Write unit cooling fan /1 (FM5) AC drive board (ACDB) DC power supply /2 (DCPS2)
- Code: C-4305
- Description: The rotation of the write unit cooling fan /2 (FM8) is checked and the 24V power source is also checked. An abnormal condition occurs with the FM8 EM signal a specified period of time after the write unit cooling fan /2 (FM8) turns ON. This abnormal condition recurs even a specified period of time after FM8 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector Write unit cooling fan /2 (FM8) AC drive board (ACDB) DC power supply /2 (DCPS2)
- Code: C-4306
- Description: The blowout of ICP for the write unit cooling fan /2 (FM8) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM8 EM signal a specified period of time after the write unit cooling fan /2 (FM8) turns ON. This abnormal condition recurs even a specified period of time after FM8 is turned OFF and then turned ON, and an error detection signal (blowout of ICP) is detected.
- Causes: Confirmation of the wiring harness and the connector Write unit cooling fan /2 (FM8) AC drive board (ACDB) DC power supply /2 (DCPS2)
- Code: C-4307
- Description: The rotation of the write unit cooling fan /2 (FM8) is checked. An abnormal condition occurs with the FM8 EM signal a specified period of time after the write unit cooling fan /2 (FM8) turns ON. This abnormal condition recurs even a specified period of time after FM8 is turned OFF and then turned ON, and an error detection signal (24V cut off/ blowout of ICP) is not detected.
- Causes: Confirmation of the wiring harness and the connector Write unit cooling fan /2 (FM8) AC drive board (ACDB) DC power supply /2 (DCPS2)
- Code: C-4308
- Description: When the print is started, an error detection signal of the writing section cooling fan /2 (FM8) is detected.
- Causes: Confirmation of the wiring harness and the connector Write unit cooling fan /2 (FM8) AC drive board (ACDB) DC power supply /2 (DCPS2)
- Code: C-4309
- Description: The rotation of the cooling fan /4 (FM12) is checked and the 24V power source is also checked. An abnormal condition occurs with the FM12 EM signal a specified period of time after FM12 turns ON. This abnormal condition recurs even a specified period of time after FM12 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector Cooling fan /4 (FM12) AC drive board (ACDB) DC power supply /2 (DCPS2)
- Code: C-4310
- Description: The blowout of ICP for the cooling fan /4 (FM12) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM12 EM signal a specified period of time after FM12 turns ON. This abnormal condition recurs even a specified period of time after FM12 is turned OFF and then turned ON, and an error detection signal (blowout of ICP) is detected.
- Causes: Confirmation of the wiring harness and the connector Cooling fan /4 (FM12) AC drive board (ACDB) DC power supply /2 (DCPS2)
- Code: C-4311
- Description: Rotation of the cooling fan /4 (FM12) is checked. An abnormal condition occurs with the FM12 EM signal a specified period of time after FM12 turns ON. This abnormal condition recurs even a specified period of time after FM12 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of ICP) is not detected.
- Causes: Confirmation of the wiring harness and the connector Cooling fan /4 (FM12) AC drive board (ACDB) DC power supply /2 (DCPS2)
- Code: C-4312
- Description: The rotation of the polygon cooling fan (FM9) is checked and the 24V power source is also checked. An abnormal condition occurs with the FM9 EM signal a specified period of time after FM9 is turned ON. This abnormal condition recurs even a specified period of time after FM9 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector Polygon cooling fan (FM9) AC drive board (ACDB) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-4313
- Description: The blowout of ICP for the polygon cooling fan (FM9) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM9 EM signal a specified period of time after FM9 turns ON. This abnormal condition recurs even a specified period of time after FM9 is turned OFF and then turned ON, and an error detection signal (blowout of ICP) is detected.
- Causes: Confirmation of the wiring harness and the connector Polygon cooling fan (FM9) AC drive board (ACDB) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-4314
- Description: The rotation of the polygon cooling fan (FM9) is checked. An abnormal condition occurs with the FM9 EM signal a specified period of time after FM9 turns ON. This abnormal condition recurs even a specified period of time after FM9 is turned OFF and then turned ON, and an error detection signal (24V cut off/ blowout of ICP) is not detected.
- Causes: Confirmation of the wiring harness and the connector Polygon cooling fan (FM9) AC drive board (ACDB) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-4315#
- Description: When the print is started, an error detection signal of the polygon cooling fan (FM9) is detected.
- Causes: Confirmation of the wiring harness and the connector Polygon cooling fan (FM9) AC drive board (ACDB) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-4701
- Description: FIFO address abnormality for the printer. While in the image write, the expansion processing of image data that is read in is not correctly terminated.
- Causes: Confirmation of the wiring harness and the connector Overall control board (OACB) Gate array damaged
- Code: C-4702
- Description: An error interrupt occurs with the compression/expansion chip FIFO.
- Causes: Confirmation of the wiring harness and the connector Overall control board (OACB) Gate array damaged
- Code: C-4703
- Description: Elongation abnormality.
- Causes: Confirmation of the wiring harness and the connector Overall control board (OACB) Gate array damaged
- Code: C-4704
- Description: While in the execution of APC, no change is found in the output of the index sensor.
- Causes: Confirmation of the wiring harness and the connector Overall control board (OACB) Write unit DC power supply /1 (DCPS1)
- Code: C-4705
- Description: While in the image write, the expansion processing from the memory to the printer does not terminate within a specified period of time. The output from the page memory to the printer does not terminate within a specified period of time. The PVV is not detected within a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Overall control board (OACB) Printer control board (PRCB)
- Code: C-4706
- Description: When writing images, in spite of no resource provided, an inappropriate processing such as an access to the elongation device is made.
- Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB) Printer control board (PRCB)
- Code: C-4707
- Description: While in the image write, APC is not applicable for the correction of the sub scan beam. Due to the 12V DC power for the laser drive not supplied, the MPC being wrong and the laser defective, the laser does not light up. Also, due to the rotation of the polygon mirror unavailable, the displacement of the index sensor, and the index sensor being defective, the index sensor cannot detect the laser.
- Causes: Confirmation of the wiring harness and the connector Overall control board (OACB) Write unit DC power supply /1 (DCPS1)
- Code: C-4708
- Description: When accessing to the memory device, a defective software is detected.
- Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB) Printer control board (PRCB)
- Code: C-4709
- Description: The expansion processing from the memory to the page memory is not terminated within a specified period of time. The compression processing from the page memory to the memory is not terminated within a specified period of time. The development from the memory into the page memory is not terminated within a specified period of time. The transmission of the compressed data from memory to memory is not terminated within a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB) Printer control board (PRCB)
- Code: C-4721#
- Description: The print operation starts before the paper mis-centering adjustment is terminated. (The mis-centering adjustment is too late.)
- Causes: Confirmation of the wiring harness and the connector Centering sensor (PS1) ADU drive board (ADUDB)
- Code: C-4722#
- Description: A PWM gamma curve is not created properly.
- Causes: Cleaning of the IDC sensor Confirmation of the wiring harness and the connector IDC sensor board (IDCB) Printer control board (PRCB)
- Code: C-5010#
- Description: Communication error check between OACB/PRCB. Overall control board (OACB) communication serial reception error detection abnormality.
- Causes: Confirmation of the wiring harness and the connector Overall control board (OACB) Printer control board (PRCB)
- Code: C-5101
- Description: A speed error signal of the fusing motor (M1) is checked. An error detection signal is detected twice in succession a specified period of time after M1 turns ON. (The first signal is ignored.)
- Causes: Confirmation of the wiring harness and the connector Fusing motor (M1) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-5102#
- Description: The 24V power source for the total counter (TCT) is checked. When TCT is turned ON from OFF, an error detection signal (blowout of ICP/24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector Total Counter (TCT) AC drive board (ACDB) DC power supply /2 (DCPS2)
- Code: C-5103#
- Description: The blowout of ICP for TC in the AC drive board (ACDB) is checked. When the total counter (TCT) is turned ON from OFF, an error detection signal (blowout of ICP) is detected. However, an error detection signal (24V cut off) is not detected.
- Causes: Confirmation of the wiring harness and the connector Total Counter (TCT) AC drive board (ACDB) DC power supply /2 (DCPS2)
- Code: C-5104#
- Description: The 24V power source for the key counter (KCT) is checked. When KCT is turned ON from OFF, an error detection signal (blowout of ICP/24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector Key counter (KCT) AC drive board (ACDB) DC power supply /2 (DCPS2)
- Code: C-5105#
- Description: The blowout of ICP for KCT in the AC drive board (ACDB) is checked. When the key counter (KCT) is turned ON from OFF, an error detection signal (blowout of ICP) is detected. However, an error detection signal (24V cut off) is not detected.
- Causes: Confirmation of the wiring harness and the connector Key counter (KCT) AC drive board (ACDB) DC power supply /2 (DCPS2)
- Code: C-5301
- Description: The rotation of the cooling fan /1 (FM26) and /2 (FM27) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM26 and FM27 EM signals a specified period of time after FM26 and FM27 are turned ON. This abnormal condition recurs even a specified period of time after FM26 and FM27 are turned OFF and then ON again, and an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector Cooling fan /1 (FM26) Cooling fan /2 (FM27) AC drive board (ACDB) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-5302
- Description: The rotation of the cooling fan /1 (FM26) and /2 (FM27) is checked. An abnormal condition occurs with the FM26 and FM27 EM signals a specified period of time after FM26 and FM27 are turned ON. This abnormal condition recurs even a specified period of time after FM26 and FM27 are turned OFF and then ON again, and an error detection signal (24V cut off) is not detected.
- Causes: Confirmation of the wiring harness and the connector Cooling fan /1 (FM26) Cooling fan /2 (FM27) AC drive board (ACDB) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-5303#
- Description: The blowout of ICP for the cooling fan /1 (FM26) is checked. An abnormal condition occurs with the FM26 EM signal a specified period of time after FM26 is turned ON. This abnormal condition recurs even a specified period of time after FM26 is turned OFF and then ON again, and an error detection signal (blowout of ICP) is detected.
- Causes: Confirmation of the wiring harness and the connector Cooling fan /1 (FM26) AC drive board (ACDB) Printer control board (PRCB)
- Code: C-5304#
- Description: Rotation of the cooling fan /1 (FM26) is checked. An abnormal condition occurs with the FM26 EM signal a specified period of time after FM26 is turned ON. This abnormal condition recurs even a specified period of time after FM26 is turned OFF and then ON again, and an error detection signal (blowout of ICP) is not detected.
- Causes: Confirmation of the wiring harness and the connector Cooling fan /1 (FM26) AC drive board (ACDB) Printer control board (PRCB)
- Code: C-5305#
- Description: The blowout of ICP for the cooling fan /2 (FM27) is checked. An abnormal condition occurs with the FM27 EM signal a specified period of time after FM27 is turned ON. This abnormal condition recurs even a specified period of time after FM27 is turned OFF and then ON again, and an error detection signal (blowout of ICP) is detected.
- Causes: Confirmation of the wiring harness and the connector Cooling fan /2 (FM27) AC drive board (ACDB) Printer control board (PRCB)
- Code: C-5306#
- Description: Rotation of the cooling fan /2 (FM27) is checked. An abnormal condition occurs with the FM27 EM signal a specified period of time after FM27 is turned ON. This abnormal condition recurs even a specified period of time after FM27 is turned OFF and then ON again, and an error detection signal (blowout of ICP) is not detected.
- Causes: Confirmation of the wiring harness and the connector Cooling fan /2 (FM27) AC drive board (ACDB)
- Code: C-5307#
- Description: The rotation of the cooling fan /3 (FM6) is checked and +24V power source is also checked. An abnormal condition occurs with the FM6 EM signal a specified period of time after FM6 turns ON. This abnormal condition recurs even a specified period of time after FM6 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector Cooling fan /3 (FM6) AC drive board (ACDB) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-5308
- Description: The blowout of ICP for the cooling fan /3 (FM6) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM6 EM signal a specified period of time after FM6 turns ON. This abnormal condition recurs even a specified period of time after FM6 is turned OFF and then turned ON, and an error detection signal (blowout of ICP) is detected.
- Causes: Confirmation of the wiring harness and the connector Cooling fan /3 (FM6) AC drive board (ACDB) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-5309
- Description: Rotation of the cooling fan /3 (FM6) is checked. An abnormal condition occurs with the FM6 EM signal a specified period of time after FM6 turns ON. This abnormal condition recurs even a specified period of time after FM6 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of ICP) is not detected.
- Causes: Confirmation of the wiring harness and the connector Cooling fan /3 (FM6) AC drive board (ACDB) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-5310
- Description: When the print is started, an error detection signal of the cooling fan /1 (FM26) or the cooling fan /2 (FM27) is detected.
- Causes: Confirmation of the wiring harness and the connector Cooling fan /1 (FM26) Cooling fan /2 (FM27) AC drive board (ACDB) Printer control board (PRCB)
- Code: C-5311
- Description: When the print is started, an error detection signal of the cooling fan /3 (FM6) is detected.
- Causes: Confirmation of the wiring harness and the connector Cooling fan /3 (FM6) AC drive board (ACDB) Printer control board (PRCB)
- Code: C-5312
- Description: An abnormal condition occurs with the FM10 EM signal a specified period of time after the ADU cooling fan /1 (FM10) is turned ON. This abnormal condition recurs even a specified period of time after FM10 is turned OFF and then ON again, and an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector ADU cooling fan /1 (FM10) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
- Code: C-5313
- Description: Rotation of the ADU cooling fan / 1 (FM10) is checked. An abnormal condition occurs with the FM10 EM signal a specified period of time after FM10 is turned ON. This abnormal condition recurs even a specified period of time after FM10 is turned OFF and then ON again, and an error detection signal (24V cut off) is not detected.
- Causes: Confirmation of the wiring harness and the connector ADU cooling fan /1 (FM10) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
- Code: C-5314
- Description: An abnormal condition occurs with the FM11 EM signal a specified period of time after the ADU cooling fan /2 (FM11) is turned ON. This abnormal condition recurs even a specified period of time after FM11 is turned OFF and then ON again, and an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector ADU cooling fan /2 (FM11) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
- Code: C-5315
- Description: Rotation of the ADU cooling fan / 2 (FM11) is checked. An abnormal condition occurs with the FM11 EM signal a specified period of time after FM11 is turned ON. This abnormal condition recurs even a specified period of time after FM11 is turned OFF and then ON again, and an error detection signal (24V cut off) is not detected.
- Causes: Confirmation of the wiring harness and the connector ADU cooling fan /2 (FM11) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
- Code: C-5316
- Description: An abnormal condition occurs with the FM23 EM signal a specified period of time after the ADU cooling fan /4 (FM23) is turned ON. This abnormal condition recurs even a specified period of time after FM23 is turned OFF and then ON again, and an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector ADU cooling fan /4 (FM23) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
- Code: C-5317
- Description: Rotation of the ADU cooling fan / 4 (FM23) is checked. An abnormal condition occurs with the FM23 EM signal a specified period of time after FM23 is turned ON. This abnormal condition recurs even a specified period of time after FM23 is turned OFF and then ON again, and an error detection signal (24V cut off) is not detected.
- Causes: Confirmation of the wiring harness and the connector ADU cooling fan /4 (FM23) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
- Code: C-5318
- Description: An abnormal condition occurs with the FM25 EM signal a specified period of time after the ADU cooling fan /5 (FM25) is turned ON. This abnormal condition recurs even a specified period of time after FM25 is turned OFF and then ON again, and an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector ADU cooling fan /5 (FM25) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
- Code: C-5319
- Description: Rotation of the ADU cooling fan / 5 (FM25) is checked. An abnormal condition occurs with the FM25 EM signal a specified period of time after FM25 is turned ON. This abnormal condition recurs even a specified period of time after FM25 is turned OFF and then ON again, and an error detection signal (24V cut off) is not detected.
- Causes: Confirmation of the wiring harness and the connector ADU cooling fan /5 (FM25) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
- Code: C-5320
- Description: An abnormal condition occurs with the FM18 EM signal a specified period of time after the cooling fan /5 (FM18) is turned ON. This abnormal condition recurs even a specified period of time after FM18 is turned OFF and then ON again, and an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector Cooling fan /5 (FM18) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-5321
- Description: The blowout of ICP for the cooling fan /5 (FM18) is checked. An abnormal condition occurs with the FM18 EM signal a specified period of time after FM18 is turned ON. This abnormal condition recurs even a specified period of time after FM18 is turned OFF and then ON again, and an error detection signal (blowout of ICP) is detected.
- Causes: Confirmation of the wiring harness and the connector Cooling fan /5 (FM18) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-5322
- Description: Rotation of the cooling fan /5 (FM18) is checked. An abnormal condition occurs with the FM18 EM signal a specified period of time after FM18 is turned ON. This abnormal condition recurs even a specified period of time after FM18 is turned OFF and then ON again, and an error detection signal (24V cut off) is not detected.
- Causes: Confirmation of the wiring harness and the connector Cooling fan /5 (FM18) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-5330
- Description: The rotation of the power supply cooling fan /3 (FM32) is checked. An abnormal condition occurs with the FM32 EM signal a specified period of time after FM32 is turned ON. This abnormal condition recurs even a specified period of time after FM32 is turned OFF and then ON again, and an error detection signal (24V cut off) is not detected.
- Causes: Confirmation of the wiring harness and the connector Power supply cooling fan /3 (FM32) DC power supply /2 (DCPS2)
- Code: C-6101
- Description: The scanner home sensor (PS5) does not turn ON within a specified period of time after the home position search is started.
- Causes: Confirmation of the wiring harness and the connector Scanner motor (M13) Scanner home sensor (PS5) Scanner drive board (SDB) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-6301
- Description: The rotation of the scanner cooling fan (FM7) is checked, and 24V power source is also checked. An abnormal condition occurs with the FM7 EM signal a specified period of time after FM7 turns ON. This abnormal condition recurs even a specified period of time after FM7 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
- Causes: Confirmation of the wiring harness and the connector Scanner cooling fan (FM7) Scanner drive board (SDB) Printer control board (PRCB) DC power supply /2 (DCPS2)
- Code: C-6701
- Description: When processing images, a filter coefficient cannot be created normally.
- Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB)
- Code: C-6702
- Description: FIFO address abnormality for the scanner. While in the image read, the compression of image data that is read in is not correctly terminated.
- Causes: Confirmation of the wiring harness and the connector Overall control board (OACB) (Gate array damaged)
- Code: C-6703
- Description: After negation of SVV, the compression of images that are read in and their development into the page memory are not terminated within a specified period of time.
- Causes: Confirmation of the wiring harness and the connector Overall control board (OACB) (Gate array damaged)
- Code: C-6704
- Description: While in the image read, the compression processing from the scanner into the memory does not terminate within a specified period of time. The development from the scanner into the page memory does not terminate within a specified period of time. The SVV is not detected within a specified period of time.
- Causes: Confirming the DF operation Confirmation of the wiring harness and the connector Overall control board (OACB) Printer control board (PRCB)
- Code: C-6705
- Description: When reading images, in spite of no resource provided, an inappropriate processing such as an access to the compression device is made.
- Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB
- Code: C-6706
- Description: While in the image read, SVV does not turn OFF within a specified period of time and the preparation for scanning the next page cannot be started.
- Causes: Confirmation of the wiring harness and the connector Overall control board (OACB)
- Code: C-6707
- Description: Shading correction abnormality (GA abnormality).
- Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB)
- Code: C-6708
- Description: AOC/AGC adjustment abnormality. The light blocking cover at the read section and the lens cover are removed. • The connector of the CCD board is disconnected. • The power cable of the CCD board is unplugged. • The ICP of the CCD board is cut off. The light volume of the exposure lamp is excessive. The exposure lamp does not light up.
- Causes: 1. CCD related parts Confirmation of the wiring harness and the connector CCD board (CCDB) Overall control board (OACB) 2. Exposure lamp related parts Confirmation of the wiring harness and the connector Exposure lamp (L4) L4 inverter (L4INVB) Scanner drive board (SDB)
- Code: C-6709#
- Description: The adjustment data evacuated by resolutions is not available.
- Causes: Confirmation of the wiring harness and the connector Overall control board (OACB)
- Code: C-6710#
- Description: A density conversion gamma curve cannot be created normally.
- Causes: Confirmation of the wiring harness and the connector Overall control board (OACB)
- Code: C-6711
- Description: Calibration start abnormality.
- Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB)
- Code: C-6712
- Description: Calibration completion abnormality.
- Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB)
- Code: C-6713
- Description: Despite of the MPC not being terminated, the initial sampling of the APC is attempted.
- Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB)
- Code: C-6714
- Description: While executing the APC, the execution of the MPC is attempted.
- Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB)
- Code: C-6716
- Description: When a clock for the image write is abnormal, the sub scan beam interval is attempted to be corrected.
- Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB)
- Code: C-6717
- Description: Sequentially shot page area abnormality. Due to an image area abnormality on the memory, images cannot be developed on the memory.
- Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB)
- Code: C-6718
- Description: The PVV is turned ON before the initial APC start processing is completed.
- Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Write unit Overall control board (OACB) Printer control board (PRCB)
- Code: C-6719
- Description: The scan operation starts before the original skew adjustment is terminated. (The skew adjustment is too late.)
- Causes: Confirming the DF operation Confirmation of the wiring harness and the connector Original skew sensor /Rr (PS311: DF) Original skew sensor /Rr (PS312: DF) Overall control board (OACB)
- Code: C-6721
- Description: The AGC is retried due to the decreased light volume of the exposure lamp. However, no error occurs.
- Causes: Confirmation of the wiring harness and the connector Exposure lamp (L4) L4 inverter (L4INVB) Scanner drive board (SDB)
- Code: C-6723
- Description: Due to the paper skew correction amount being in excess of the permissible limit, the print is made with the leading edge shifted.
- Causes: Confirming the DF operation Confirmation of the wiring harness and the connector Original skew sensor /Rr (PS311: DF) Original skew sensor /Rr (PS312: DF) Overall control board (OACB)
- Code: C-6801
- Description: A communication error between OACB and OB1 is checked.
- Causes: Confirmation of the wiring harness and the connector Operation board /1 (OB1) Operation board /3 (OB3) Overall control board (OACB)
- Code: C-8001
- Description: Although the main body sends out data according to the data retransmission request made by the DF, a retransmission request signal is received again.
- Causes: Confirmation of the wiring harness and the connector DF control board (DFCB: DF) Overall control board (OACB: main body)
- Code: C-8002
- Description: When a checksum error or an SRGA reception error was detected while in the reception in serial communication, a signal was sent to make a request for sending data again. And when data is being received upon this request, a checksum error or an SRGA reception error is detected again.
- Causes: Confirmation of the wiring harness and the connector DF control board (DFCB: DF) Overall control board (OACB: main body)
- Code: C-8003
- Description: When the main power switch (SW1) is ON, there is no response to the initial communication request from the main body to the DF even after a specified period of time elapses.
- Causes: Confirmation of the wiring harness and the connector DF control board (DFCB)
- Code: C-8201
- Description: Tray up/down motor (M303) abnormality.
- Causes: Confirmation of the wiring harness and the connector Confirmation of the original tray up/down drive parts Tray up/down motor (M303) DF control board (DFCB)
- Code: C-8301
- Description: Cooling fan (FM301) abnormality.
- Causes: Confirmation of the wiring harness and the connector Cooling fan (FM301) DF control board (DFCB)
- Code: C-8401
- Description: Original registration sensor (PS306) abnormality.
- Causes: Confirming the sensor operation Confirmation of the wiring harness and the connector Original registration sensor (PS306) DF control board (DFCB)
- Code: C-8402
- Description: Original conveyance sensor (PS308) abnormality.
- Causes: Confirming the sensor operation Confirmation of the wiring harness and the connector Original conveyance sensor (PS308) DF control board (DFCB)
- Code: C-8403
- Description: Original reverse sensor (PS309) abnormality.
- Causes: Confirming the sensor operation Confirmation of the wiring harness and the connector Original reverse sensor (PS309) DF control board (DFCB)
- Code: C-8404
- Description: Non-volatile memory error.
- Causes: Confirmation of the wiring harness and the connector DF control board (DFCB)
- Code: C-8405
- Description: Reverse jam sensor (PS304) abnormality.
- Causes: Confirming the sensor operation Confirmation of the wiring harness and the connector Reverse jam sensor (PS304) DF control board (DFCB)
- Code: C-8406
- Description: Original reverse/exit sensor (PS313) abnormality.
- Causes: Confirming the sensor operation Confirmation of the wiring harness and the connector Original reverse/exit sensor (PS313) DF control board (DFCB)
- Code: C-A001
- Description: DMA abnormality.
- Causes:
- Code: C-A002
- Description: HDD/2 (HDD2) abnormality.
- Causes: Confirmation of the wiring harness and the connector HDD/2 (HDD2) PCI relay board (PCIRB) IC board (ICB) Overall control board (OACB)
- Code: C-A003
- Description: IC cooling fan (FM28) abnormality.
- Causes: Confirmation of the wiring harness and the connector IC cooling fan (FM28) PCI relay board (PCIRB) IC board (ICB) Overall control board (OACB)
- Code: C-A004
- Description: FATAL error.
- Causes:
- Code: C-A005
- Description: The CF card in ICB is different from the program version of the HDD/2 (HDD2).
- Causes: Reinstalling IC firmware IC board (ICB)
- Code: C-A006
- Description: While in the security ON, the unlock of the HDD/2 (HDD2) results in failure. (Due to the mismatch of the password)
- Causes: Confirmation of the wiring harness and the connector HDD/2 (HDD2) IC board (ICB)
- Code: C-A007
- Description: While in the security ON, an unlocked HDD is connected.
- Causes: Confirmation of the wiring harness and the connector HDD/2 (HDD2) IC board (ICB)
- Code: C-A008
- Description: An unformatted HDD/2 (HDD2) is detected.
- Causes: Confirmation of the wiring harness and the connector Hard disk format HDD/2 (HDD2)
- Code: C-A101
- Description: The communication from ICB to the overall control board (OACB) is blocked.
- Causes: Confirmation of the wiring harness and the connector PCI relay board (PCIRB) IC board (ICB) Overall control board (OACB)
- Code: C-C101
- Description: Initial communication error between OACB/PRCB. When the main power switch (SW1) is turned ON, a response from the printer control board (PRCB) is not received even after a specified period of time elapses.
- Causes: Confirmation of the wiring harness and the connector Overall control board (OACB) Printer control board (PRCB)
- Code: C-C102
- Description: Communication error between OACB/PRCB.
- Causes: Confirmation of the wiring harness and the connector Overall control board (OACB) Printer control board (PRCB)
- Code: C-C103
- Description: Communication error between OACB/OB1.
- Causes: Confirmation of the wiring harness and the connector Operation board /1 (OB1) Operation board /3 (OB3) Overall control board (OACB)
- Code: C-C104
- Description: When the main power switch (SW1) is ON, a region into which no write was made by the ISW is detected in the printer control program.
- Causes: S and CA program
- Code: C-C106
- Description: While in the data transmission by the ISW, a formal header information cannot be received within a specified period of time.
- Causes: USB cable USB port on PC
- Code: C-C107
- Description: While in the data transmission by the ISW, a checksum error or header error is detected with the download data.
- Causes: USB cable Program file corruption
- Code: C-C108
- Description: When ISW transfers data, the data is not written into the flash ROM correctly.
- Causes: USB cable The board to which the data is transferred.
- Code: C-C109
- Description: When the main power switch (SW1) is ON, a region into which no write was made by the ISW is detected in the FS control program.
- Causes: FS control program
- Code: C-C117
- Description: When turning the sub power switch (SW2) ON, ISW unwritten area in the GP program was detected.
- Causes: GP control firmware
- Code: C-C119
- Description: When turning the sub power switch (SW2) ON, ISW unwritten area in the MK program was detected.
- Causes: I/F board (IFB)
- Code: C-C120
- Description: When the main power switch (SW1) is ON, a region into which no write was made by the ISW is detected in the DF control program.
- Causes: Confirmation of the wiring harness and the connector DF control board (DFCB: DF) Overall control board (OACB: main body)
- Code: C-C125
- Description: When the main power switch (SW1) is ON, a region into which no write was made by the ISW is detected in the IC program.
- Causes: IC program
- Code: C-D001
- Description: HDD/1 (HDD1) initialization abnormality. The HDD1 is defective, or the connector is poorly connected.
- Causes: Confirmation of the wiring harness and the connector Reinstalling firmware HDD/1 (HDD1) Overall control board (OACB)
- Code: C-D002
- Description: The JOB information cannot be stored on the HDD/1 (HDD1).
- Causes: Confirmation of the wiring harness and the connector Reinstalling firmware HDD/1 (HDD1) Overall control board (OACB)
- Code: C-D003
- Description: When HDD/1 (HDD1) JOB auto deletion is being executed, a route cannot be opened.
- Causes: Confirmation of the wiring harness and the connector Reinstalling firmware HDD/1 (HDD1) Overall control board (OACB)
- Code: C-D004
- Description: HDD/1 (HDD1) access defective. The HDD1 is defective, or the connector is poorly connected.
- Causes: Confirmation of the wiring harness and the connector Reinstalling firmware HDD/1 (HDD1) Overall control board (OACB)
- Code: C-D010
- Description: HDD overwrite erase is conducted.
- Causes:
- Code: C-D101
- Description: Tandem communication error
- Causes: Confirmation of the wiring harness and the connector Confirmation of the network connection for tandem Confirmation of the tandem setting of both machine Overall control board (OACB)
- Code: C-D102
- Description: Tandem image transmission error
- Causes: Confirmation of the wiring harness and the connector Confirmation of the network connection for tandem Confirmation of the tandem setting of both machine Overall control board (OACB)
- Code: C-E001
- Description: The message queue is insufficient or destroyed.
- Causes: Confirmation of the wiring harness and the connector PCI relay board (PCIRB) IC board (ICB) Overall control board (OACB)
- Code: C-E002
- Description: The parameter value is in excess of the permissible limits.
- Causes: Confirmation of the wiring harness and the connector PCI relay board (PCIRB) IC board (ICB) Overall control board (OACB)
- Code: C-E003
- Description: The ID of the task that sends the message queue is undefined.
- Causes: Confirmation of the wiring harness and the connector PCI relay board (PCIRB) IC board (ICB) Overall control board (OACB)
- Code: C-E004
- Description: The receiving event of the message is undefined.
- Causes: Confirmation of the wiring harness and the connector PCI relay board (PCIRB) IC board (ICB) Overall control board (OACB)
- Code: C-E005
- Description: Memory access abnormality.
- Causes: Confirmation of the wiring harness and the connector PCI relay board (PCIRB) IC board (ICB) Overall control board (OACB)
- Code: C-E006
- Description: Header readout address abnormality.
- Causes:
– Get more error code list with quick guide to fix printer product, click here
– About get help with reseting Epson inkpad or others, click here
– Get more information about Epson XP 15000 troubleshooting, click here
– Buy cheap key of Epson WIC Reset Tool, CLICK HERE
– Key Epson Adjustment Program, CLICK HERE
– Download Epson printer driver, CLICK HERE
– Download Epson XP-6100 Driver, Firmware and Manuals, CLICK HERE
Contact us to get support with Konica-Minolta bizhub Pro 950 Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.