[SOLVED] Quick fix Konica-Minolta Di3510 list error codes
– Compatible Printer model: Konica-Minolta Di3510
– Konica-Minolta Di3510 Error Codes with quick guides:
- Code: C0000
- Description: Main Motor Failure
• The Transport Motor Lock signal remains set to H for a set period of time while the Transport Motor is turning. - Troubleshooting Guides: 1 Check the M2 connector for proper connection, and correct as necessary 2 Check the M2 for proper drive coupling, and correct as necessary. 3 M2 operation check. 4 Replace PWB-A. 5 Replace PU1.
- Code: C0010
- Description: Imaging Unit Motor Failure
• The Imaging Unit Motor Lock signal remains set to H for a set period of time while the Imaging Unit Motor is turning. • The Imaging Unit Motor Lock signal remains set to L for a set period of time while the Imaging Unit Motor remains stopped. - Troubleshooting Guides: 1 Check the M1 connector for proper connection, and correct as necessary. 2 Check the M1 for proper drive coupling, and correct as necessary 3 M1 operation check. 4 Replace PWB-A. 5 Replace PU1.
- Code: C0044
- Description: EDH Fan Motor Failure
• Refer to the Service Manual for the relevant option. - Troubleshooting Guides:
- Code: C0045
- Description: Cooling Fan Failure
• The Cooling Fan Motor Lock signal remains set to H for a set period of time while the Cooling Fan Motor is turning. • The Cooling Fan Motor Lock signal remains set to L for a set period of time while the Cooling Fan Motor remains stopped. - Troubleshooting Guides: 1 Check the motor connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M5 operation check. 4 Replace PWB-A.
- Code: C004E
- Description: Power Unit Cooling Fan Failure
• The Power Unit Cooling Fan Motor Lock signal remains set to H for a set period of time while the Power Unit Cooling Fan Motor is turning. • The Power Unit Cooling Fan Motor Lock signal remains set to L for a set period of time while the Power Unit Cooling Fan Motor remains stopped. - Troubleshooting Guides: 1 Check the motor connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M4 operation check. 4 Replace PWB-A.
- Code: C004F
- Description: IU Cooling Fan Failure
• The I/U Cooling Fan Motor Lock signal remains set to H for a set period of time while the I/U Cooling Fan Motor is turning. • The I/U Cooling Fan Motor Lock signal remains set to L for a set period of time while the I/U Cooling Fan Motor remains stopped. - Troubleshooting Guides: 1 Check the motor connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M6 operation check. 4 Replace PWB-A.
- Code: C0214
- Description: Abnormal Image Transfer Voltage
• The image transfer voltage exceeds 100 V for the set period of time while the Imaging Unit Motor remains stopped. - Troubleshooting Guides: 1 Check the installation of the Image Transfer Roller. 2 Replace TH1.
- Code: C0500
- Description: Fusing Warm-Up Failure (Main)
• The Fusing Roller Thermistor does not detect the required temperature within 30 sec. after a warm-up cycle has begun; therefore, the copier does not complete the warm-up cycle. • The temperature of the Fusing Rollers does not reach the required level even after the set period of time has elapsed during a warm-up cycle. - Troubleshooting Guides: 1 Check that the Fusing Roller Heater Lamp comes on when the Power Switch is set to ON, and correct or replace as necessary. 2 Check that the Fusing Roller Sub Heater Lamp comes on when the Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the Fusing Roller Thermistor and the Fusing Roller Sub Thermistor, and correct or clean as necessary. 4 Check the operation of the Fusing Roller Thermistor. Remove CN80 (4P), and then check that the resistance across CN80-2 and – 3 on the Thermistor is infinity. 5 Check the operation of the Fusing Roller Sub Thermistor. Remove CN81 (4P), and then check that the resistance across CN81-2 and – 3 on the Thermistor is infinity. 6 Check the continuity of the Fusing Roller Heater Lamp. Correct or replace as necessary. 7 Check the continuity of the Fusing Roller Sub Heater Lamp. Correct or replace as necessary. 8 Replace PU1. 9 Replace PWB-A.
- Code: C0501
- Description: Fusing Warm-Up Failure (Sub)
• The Fusing Roller Sub Thermistor does not detect the required temperature within 30 sec. after a warm-up cycle has begun; therefore, the copier does not complete the warm-up cycle. • The temperature of the Fusing Rollers does not reach the required level even after the set period of time has elapsed during a warm-up cycle. - Troubleshooting Guides: 1 Check that the Fusing Roller Heater Lamp comes on when the Power Switch is set to ON, and correct or replace as necessary. 2 Check that the Fusing Roller Sub Heater Lamp comes on when the Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the Fusing Roller Thermistor and the Fusing Roller Sub Thermistor, and correct or clean as necessary. 4 Check the operation of the Fusing Roller Thermistor. Remove CN80 (4P), and then check that the resistance across CN80-2 and – 3 on the Thermistor is infinity. 5 Check the operation of the Fusing Roller Sub Thermistor. Remove CN81 (4P), and then check that the resistance across CN81-2 and – 3 on the Thermistor is infinity. 6 Check the continuity of the Fusing Roller Heater Lamp. Correct or replace as necessary. 7 Check the continuity of the Fusing Roller Sub Heater Lamp. Correct or replace as necessary. 8 Replace PU1. 9 Replace PWB-A.
- Code: C0510
- Description: Low Fuser Temperature Failure (Main)
• The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105C during standby. • The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105C during printing. - Troubleshooting Guides: 1 Check that the Fusing Roller Heater Lamp comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary. 2 Check that the Fusing Roller Sub Heater Lamp comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary. 3 Check the installation of the Fusing Roller Thermistor and the Fusing Roller Sub Thermistor, and correct or clean as necessary. 4 Check the operation of the Fusing Roller Thermistor. Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity. 5 Check the operation of the Fusing Roller Sub Thermistor. Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity. 6 Check the continuity of the Fusing Roller Heater Lamp. Correct or replace as necessary. 7 Check the continuity of the Fusing Roller Sub Heater Lamp. Correct or replace as necessary. 8 Replace PU1. 9 Replace PWB-A.
- Code: C0511
- Description: Low Fuser Temperature Failure (Sub)
• The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105C during standby. • The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105C during printing. - Troubleshooting Guides: 1 Check that the Fusing Roller Heater Lamp comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary. 2 Check that the Fusing Roller Sub Heater Lamp comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary. 3 Check the installation of the Fusing Roller Thermistor and the Fusing Roller Sub Thermistor, and correct or clean as necessary. 4 Check the operation of the Fusing Roller Thermistor. Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity. 5 Check the operation of the Fusing Roller Sub Thermistor. Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity. 6 Check the continuity of the Fusing Roller Heater Lamp. Correct or replace as necessary. 7 Check the continuity of the Fusing Roller Sub Heater Lamp. Correct or replace as necessary. 8 Replace PU1. 9 Replace PWB-A.
- Code: C0520
- Description: High Fuser Temperature Failure (Main)
• The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature above 240C when the Power Switch is set to ON. • The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature above 240C when the Power Switch is set to ON. - Troubleshooting Guides: 1 Check that the Fusing Roller Heater Lamp comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary. 2 Check that the Fusing Roller Sub Heater Lamp comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary. 3 Check the installation of the Fusing Roller Thermistor and the Fusing Roller Sub Thermistor, and correct or clean as necessary. 4 Check the operation of the Fusing Roller Thermistor. Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity. 5 Check the operation of the Fusing Roller Sub Thermistor. Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity. 6 Check the continuity of the Fusing Roller Heater Lamp. Correct or replace as necessary. 7 Check the continuity of the Fusing Roller Sub Heater Lamp. Correct or replace as necessary. 8 Replace PU1. 9 Replace PWB-A.
- Code: C0521
- Description: High Fuser Temperature Failure (Sub)
• The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature above 240C when the Power Switch is set to ON. • The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature above 240C when the Power Switch is set to ON. - Troubleshooting Guides: 1 Check that the Fusing Roller Heater Lamp comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary. 2 Check that the Fusing Roller Sub Heater Lamp comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary. 3 Check the installation of the Fusing Roller Thermistor and the Fusing Roller Sub Thermistor, and correct or clean as necessary. 4 Check the operation of the Fusing Roller Thermistor. Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity. 5 Check the operation of the Fusing Roller Sub Thermistor. Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity. 6 Check the continuity of the Fusing Roller Heater Lamp. Correct or replace as necessary. 7 Check the continuity of the Fusing Roller Sub Heater Lamp. Correct or replace as necessary. 8 Replace PU1. 9 Replace PWB-A.
- Code: C0900
- Description: 3rd Drawer Lift-Up Motor Failure
- Troubleshooting Guides: 1 Check the connectors of each motor and sensor for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection, and correct as necessary. 4 PC6 sensor check. 5 PC12 sensor check. 6 PC114-PF sensor check. 7 PC123-PF sensor check. 8 M7 operation check. 9 M8 operation check. 10 M124-PF operation check. 11 M125-PF operation check. 12 Replace PWB-A. 13 Replace the PWB-C2 PF Control Board. 14 Replace PU1.
- Code: C0910
- Description: 2nd Drawer Lift-Up Motor Failure
- Troubleshooting Guides: 1 Check the connectors of each motor and sensor for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection, and correct as necessary. 4 PC6 sensor check. 5 PC12 sensor check. 6 PC114-PF sensor check. 7 PC123-PF sensor check. 8 M7 operation check. 9 M8 operation check. 10 M124-PF operation check. 11 M125-PF operation check. 12 Replace PWB-A. 13 Replace the PWB-C2 PF Control Board. 14 Replace PU1.
- Code: C0920
- Description: 1st Drawer Lift-Up Motor Failure
- Troubleshooting Guides: 1 Check the connectors of each motor and sensor for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection, and correct as necessary. 4 PC6 sensor check. 5 PC12 sensor check. 6 PC114-PF sensor check. 7 PC123-PF sensor check. 8 M7 operation check. 9 M8 operation check. 10 M124-PF operation check. 11 M125-PF operation check. 12 Replace PWB-A. 13 Replace the PWB-C2 PF Control Board. 14 Replace PU1.
- Code: C0950
- Description: 4th Drawer Lift-Up Motor Failure
- Troubleshooting Guides: 1 Check the connectors of each motor and sensor for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection, and correct as necessary. 4 PC6 sensor check. 5 PC12 sensor check. 6 PC114-PF sensor check. 7 PC123-PF sensor check. 8 M7 operation check. 9 M8 operation check. 10 M124-PF operation check. 11 M125-PF operation check. 12 Replace PWB-A. 13 Replace the PWB-C2 PF Control Board. 14 Replace PU1.
- Code: C0960
- Description: Manual Bypass Paper-Lifting Failure
• The Manual Feed Tray Lift-Up Sensor (PC29) is not blocked or unblocked even after the set period of time has elapsed after the Manual Paper Feed Pick-Up Solenoid (SL3) is energized after the manual feed paper take-up operation has begun. - Troubleshooting Guides: 1 Check the SL3 connector for proper connection, and correct as necessary. 2 PC29 sensor check. 3 SL3 operation check. 4 Replace PWB-A. 5 Replace PU1.
- Code: C0990
- Description: LCC Elevator Motor Failure
• The Elevator Motor Pulse Sensor (PC10-LCC) cannot detect both edges of H/L even after the set period of time has elapsed while the Elevator Motor (M5-LCC) is turning backward/forward (raise/lower). - Troubleshooting Guides: 1 Check the motor connectors and other connectors for proper connection, and correct as necessary. 2 PC10-LCC sensor check. 3 M5-LCC operation check. 4 Replace PWB-A.
- Code: C0991
- Description: LCC Lift Failure
• The Tray Upper Limit Sensor (PC4-LCC) is not unblocked even after the set period of time has elapsed after the paper lift-up operation has begun. • The Tray Upper Limit Sensor (PC4-LCC) is not unblocked even after the set pulse is detected by the Elevator Motor Pulse Sensor (PC10-LCC) after the paper lift-up operation has begun. • The Tray Upper Limit Sensor (PC4-LCC) is not unblocked even after the set period of time has elapsed with paper loaded during the paper lift-up operation. • The Tray Lower Position Sensor (PC13-LCC) is not blocked even after the set pulse is detected by the Elevator Motor Pulse Sensor (PC10-LCC) after the paper lift-up operation has begun. • The Tray Lower Position Sensor (PC13-LCC) is not blocked even after the set period of time has elapsed after the lowering operation has begun. • The Tray Lower Position Sensor (PC13-LCC) is not unblocked even after the set pulse is detected by the Elevator Motor Pulse Sensor (PC10-LCC) after the lowering operation has begun. • The Tray Upper Limit Sensor (PC4-LCC) is not blocked even after the set pulse is detected by the Elevator Motor Pulse Sensor (PC10-LCC) after the paper lift-up operation has begun. • The Lower Limit Sensor (PC7-LCC) is not unblocked during the lowering operation. - Troubleshooting Guides: 1 Check the sensor connector for proper connection, and correct as necessary. 2 PC4-LCC sensor check. 3 PC13-LCC sensor check. 4 PC10-LCC sensor check. 5 PC7-LCC sensor check. 6 Replace PWB-C1 LCC.
- Code: C0996
- Description: LCC Lock Release Failure
• The drawer cannot be determined to be out of position even after the set period of time has elapsed after the Tray Lock Solenoid (SL1-LCC) is energized after the lowering operation is finished. - Troubleshooting Guides: 1 Check the SL1-LCC connector for proper connection, and correct as necessary. 2 SL1-LCC operation check. 3 Replace PWB-C1 LCC.
- Code: C0997
- Description: LCC Shift Gate Operation Failure
• The Shift Gate Home Position Sensor (PC14-LCC) cannot be set to L even after the set period of time has elapsed after the operation of the Shift Gate Motor (M3-LCC) has begun with the Shift Gate Home Position Sensor (PC14-LCC) set to L. - Troubleshooting Guides: 1 Check the PC14-LCC connector for proper connection, and correct as necessary. 2 PC14-LCC sensor check. 3 M3-LCC operation check. 4 Replace PWB-C1 LCC.
- Code: C0998
- Description: LCC Shift Failure
• The Shifter Return Position Sensor (PC11-LCC) is not unblocked even after the set period of time has elapsed after the shift operation has begun (shifter is moved to the right). • The Shifter Return Position Sensor (PC11-LCC) is not unblocked even after the set pulse is detected by the Shift Motor Pulse Sensor (PC8-LCC) after the shift operation has begun (shifter is moved to the right). • The Shifter Home Position Sensor (PC12-LCC) is not unblocked even after the set pulse is detected by the Shift Motor Pulse Sensor (PC8-LCC) after the shift operation has begun (shifter is moved to the right). • The Shifter Home Position Sensor (PC12-LCC) is not unblocked even after the set period of time has elapsed after the return operation has begun (shifter is moved to the left). • The Shifter Home Position Sensor (PC12-LCC) is not unblocked even after the set pulse is detected by the Shift Motor Pulse Sensor (PC8-LCC) after the return operation has begun (shifter is moved to the left). • The Shifter Return Position Sensor (PC11-LCC) is not unblocked even after the set pulse is detected by the Shift Motor Pulse Sensor (PC8-LCC) after the return operation has begun (shifter is moved to the left). - Troubleshooting Guides: 1 Check the connector for proper connection, and correct as necessary. 2 PC8-LCC sensor check. 3 PC11-LCC sensor check. 4 PC12-LCC sensor check. 5 Replace PWB-C1 LCC.
- Code: C099C
- Description: LCC Shift Motor Failure
• The Shift Motor Pulse Sensor (PC8-LCC) cannot detect both the rising and falling edges of H/L even after the set period of time has elapsed while the Shift Motor (M4-LCC) is turning backward/forward (raise/lower). - Troubleshooting Guides: 1 Check the motor connectors and other connectors for proper connection, and correct as necessary. 2 PC8-LCC sensor check. 3 M4-LCC operation check. 4 Replace PWB-C1 LCC.
- Code: C099D
- Description: LCC Communication Failure
• Due to a software malfunction, etc., the time on the watchdog timer has run out and a reset is performed. - Troubleshooting Guides: 1 Turn the copier off, then on again. 2 Check the connector for proper connection, and correct as necessary. 3 Replace PWB-C1 LCC.
- Code: C0B20
- Description: Staple Unit CD Drive Failure
- Troubleshooting Guides:
- Code: C0B30
- Description: Aligning Plate 1 Drive Failure
- Troubleshooting Guides:
- Code: C0B32
- Description: Aligning Plate 2 Drive Failure
- Troubleshooting Guides:
- Code: C0B47
- Description: Paper-Lifter Drive Failure
- Troubleshooting Guides:
- Code: C0B48
- Description: Exit Roller Pressure/ Retraction Failure
- Troubleshooting Guides:
- Code: C0B4A
- Description: Saddle Exit Roller Pressure/Retraction Failure
- Troubleshooting Guides:
- Code: C0B4B
- Description: Shutter Drive Failure
- Troubleshooting Guides:
- Code: C0B4C
- Description: Saddle Exit Motor Failure
- Troubleshooting Guides:
- Code: C0B4D
- Description: Saddle Advance/ Retract Guide Motor Failure
- Troubleshooting Guides:
- Code: C0B4F
- Description: Saddle Movable Guide Drive Failure
- Troubleshooting Guides:
- Code: C0B50
- Description: Staple Drive Failure
- Troubleshooting Guides:
- Code: C0B56
- Description: Saddle Staple 1 Drive Failure
- Troubleshooting Guides:
- Code: C0B57
- Description: Saddle Staple 2 Drive Failure
- Troubleshooting Guides:
- Code: C0B73
- Description: Punch Cam Motor Unit Failure
- Troubleshooting Guides:
- Code: C0BA0
- Description: Elevator Motor Ascent/ Descent Drive Failure
- Troubleshooting Guides:
- Code: C0BC2
- Description: Crease Motor Drive Failure
- Troubleshooting Guides:
- Code: C0F32
- Description: ATDC Sensor Failure
• The scanning value of the ATDC Sensor is less than 7% while the Imaging Unit Motor is turning. • The scanning value of the ATDC Sensor is more than 19% while the Imaging Unit Motor is turning. - Troubleshooting Guides: 1 Check the ATDC sensor connector for proper connection, and correct as necessary. 2 Remove the Developing Unit from the Imaging Unit, and then replace UN2. 3 Run F8. 4 Replace PWB-A. 5 Replace PU1.
Solve Konica-Minolta Di3510 Error codes
- Code: C0F33
- Description: ATDC Adjustment Failure
• The adjustment of the ATDC control voltage could not be completed in the set period of time when function F8 is run. • The ATDC control voltage was not within the range of 5.39 V to 8.15 V when function F8 is run. - Troubleshooting Guides: 1 Check the ATDC sensor connector for proper connection, and correct as necessary. 2 Remove the Developing Unit from the Imaging Unit, and then replace UN2. 3 Run F8. 4 Replace PWB-A. 5 Replace PU1.
- Code: C12D0
- Description: MIO Device Failure
• The MIO device does not operate properly. - Troubleshooting Guides: 1 Turn OFF, then ON, the power. 2 Check the CLAN Board connectors for proper connection and correct as necessary. 3 Check the MFB3 Board connectors for proper connection and correct as necessary. 4 Change the CLAN Board. 5 Change the MFB3 Board.
- Code: C1300
- Description: Polygon Motor Failure
• The Polygon Motor Lock signal could not be detected within the set period of time after the Polygon Motor is energized. (Faulty start detection) • No First Lock signals are detected during the 1second period that starts 1 second after a First Lock signal. (Faulty lock signal detection) • The Polygon Motor Lock signal could not be detected after the set period of time has elapsed while the Polygon Motor is turning. (Out-of-timing lock detection) • The Polygon Motor Lock signal is set to ON for longer than the set period of time while the Polygon Motor remains stopped. (Abnormal lock detection) - Troubleshooting Guides: 1 Check the PH connector for proper connection, and correct as necessary. 2 Replace PH Unit. 3 Replace PWB-A.
- Code: C1330
- Description: Main Unit Communication Failure
• Communications with the Master Board and the MFB3 Board fail. - Troubleshooting Guides: 1 Check the MFB3 Board connector for proper connection, and correct as necessary. 2 Check the PWB-A Board connector for proper connection, and correct as necessary. 3 Check the flat cable between MFB3 and lPWB-A for proper connection, and correct as necessary. 4 Turn the copier off, then on again. 5 Replace the MFB3 Board. 6 Replace the PWB-A Board.
- Code: C133A
- Description: Main Unit G/A Communication Failure
• Communications with the gate array for expansion I/O (the IC mounted on the Master Board) fail. - Troubleshooting Guides: 1 Turn the copier off, then on again. 2 Check each control board and the Master Board for proper connection, and correct as necessary. 3 Replace the Master Board if necessary.
- Code: C133B
- Description: Exit Option Paper Transport Failure
• The connection status of a finishing option is changed after the copier has been turned on. - Troubleshooting Guides: 1 Turn the copier off, then on again. 2 Check each control board and the Master Board for proper connection, and correct as necessary. 3 Replace the appropriate Control Board and the Master Board if necessary.
- Code: C13D0
- Description: EEPROM Failure
• An EEPROM where no initial data is written is detected. - Troubleshooting Guides: 1 Unplug and plug in the power cord, and then turn off and turn on the copier. 2 Check the EEPROM on the Master Board for proper connection, and correct as necessary. 3 Replace PWB-A. 4 Replace the EEPROM.
- Code: C13E0
- Description: Flash ROM Failure
• The Flash ROM data was determined to be faulty when the unit was turned on. - Troubleshooting Guides: 1 Unplug and plug in the power cord, and then turn off and turn on the copier. 2 The firmware data is overwritten. 3 Replace PWB-A.
- Code: C13F0
- Description: HSYNC Detection Failure
• No SOS falling edges are detected within the set period of time after laser emission began while the Polygon Motor is turning. • No SOS falling edges are detected while VIA remains ON. - Troubleshooting Guides: 1 Turn the copier off, then on again. 2 Check PH Unit and the Master Board connectors for proper connection, and correct as necessary. 3 Replace the PH Unit. 4 Replace PWB-A.
– Get more error code list with quick guide to fix printer product, click here
– About get help with reseting Epson inkpad or others, click here
– Get more information about Epson XP 15000 troubleshooting, click here
– Buy cheap key of Epson WIC Reset Tool, CLICK HERE
– Key Epson Adjustment Program, CLICK HERE
– Download Epson printer driver, CLICK HERE
– Download Epson XP-6100 Driver, Firmware and Manuals, CLICK HERE
Contact us to get support with Konica-Minolta Di3510 Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.