[SOLVED] Quick fix Konica-Minolta C30P list error codes
– Compatible Printer model: Konica-Minolta bizhub C30P
– Konica-Minolta bizhub C30P Error Codes with quick guides:
- Code: 0010
- Display: P MOTOR 1
- Description: Color PC drum motor malfunction
• The color PC drum motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the color PC drum motor is being rotated. - Troubleshooting Guides: 1 Check the M2 connector for proper connection and correct as necessary. 2 Check M2 for proper drive coupling and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 M2 operation check. 5 Change M2. 6 Change MFPB. 7 Change DCPU.
- Code: 0017
- Display: P MOTOR 2
- Description: Intermediate transport motor malfunction
• The intermediate transport motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the intermediate transport motor is being rotated. - Troubleshooting Guides: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check M3 for proper drive coupling and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 M3 operation check. 5 Change M3. 6 Change MFPB. 7 Change DCPU.
- Code: 0018
- Display: D MOTOR 2
- Description: Developing motor /K malfunction
• The developing motor /K does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the developing motor /K is being rotated. - Troubleshooting Guides: 1 Check the M5 connector for proper connection and correct as necessary. 2 Check M5 for proper drive coupling and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 M5 operation check. 5 Change M5. 6 Change MFPB. 7 Change DCPU.
- Code: 001B
- Display: D MOTOR 1
- Description: Developing motor / Y,M,C malfunction
• The developing motor /Y,M,C does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the developing motor /Y,M,C is being rotated. - Troubleshooting Guides: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check the MFPB connector for proper connection and correct as necessary. 3 M1 operation check. 4 Change driving unit. 5 Change MFPB. 6 Change DCPU.
- Code: 0046
- Display: FUSER FAN
- Description: Fusing fan motor malfunction
• The fusing fan motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the fusing fan motor is being rotated. - Troubleshooting Guides: 1 Check the FM2 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM2 operation check. 4 Change FM2. 5 Change MFPB.
- Code: 004C
- Display: OZONE FAN
- Description: Ozone ventilation fan motor malfunction
• The ozone ventilation fan motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the ozone ventilation fan motor is being rotated. - Troubleshooting Guides: 1 Check the FM3 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM3 operation check. 4 Change FM3. 5 Change MFPB.
- Code: 004E
- Display: POWER FAN
- Description: DC power supply fan motor malfunction
• The DC power supply fan motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the DC power supply fan motor is being rotated. - Troubleshooting Guides: 1 Check the FM1 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM1 operation check. 4 Change FM1. 5 Change MFPB.
- Code: 0060
- Display: FUSER MOTOR
- Description: Fusing motor malfunction
• The fusing motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the fusing motor is being rotated. - Troubleshooting Guides: 1 Check the M4 connector for proper connection and correct as necessary. 2 Check the fusing unit driving mechanism for possible overload and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 M4 operation check. 5 Change M4. 6 Change MFPB.
- Code: 0094
- Display: XFER DETACH 2
- Description: 2nd image transfer pressure / retraction failure
• The retraction position sensor /2 is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd transfer roller has been started.
• The retraction position sensor /2 is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd transfer roller has been started. - Troubleshooting Guides: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL5 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL5 for proper drive coupling and correct as necessary. 5 Check the MFPB connector for proper connection and correct as necessary. 6 PS10 sensor check. 7 CL5 operation check. 8 M3 operation check. 9 Change M3. 10 Change CL5. 11 Change MFPB.
- Code: 0096
- Display: XFER DETACH 1
- Description: 1st image transfer pressure / retraction failure
• The retraction position sensor /1 is not activated (retracted position) within a given period of time after the intermediate transport motor has started rotating.
• The retraction position sensor /1 is not deactivated (pressed position) within a given period of time after the intermediate transport motor has started rotating. - Troubleshooting Guides: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL4 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL4 for proper drive coupling and correct as necessary. 5 Check the MFPB connector for proper connection and correct as necessary. 6 PS9 sensor check. 7 CL4 operation check. 8 M3 operation check. 9 Change M3. 10 Change CL4. 11 Change MFPB.
- Code: 0300
- Display: POLYGON MOTOR
- Description: Polygon motor malfunction
• The polygon motor does not rotate evenly even after the lapse of a given period of time after it has been started.
• The motor lock signal remains HIGH for a given period of consecutive time while the polygon motor is being rotated. - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change MFPB.
- Code: 0310
- Display: LASER ERROR
- Description: Laser malfunction
• The SOS signal is not detected within a given period of time after the output of the laser has been started. - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change MFPB.
- Code: 0500
- Display: FUSER ERROR
- Description: Heating roller warm-up failure
• The thermistor /1 does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started. - Troubleshooting Guides: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fusing unit. 4 Change MFPB. 5 Change DCPU.
- Code: 0501
- Display: FUSER ERROR
- Description: Fusing pressure roller warm-up failure
• The thermistor /2 does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started. - Troubleshooting Guides: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fusing unit. 4 Change MFPB. 5 Change DCPU.
- Code: 0510
- Display: FUSER ERROR
- Description: Abnormally low heating roller temperature
• The temperature detected by the thermistor /1 remains lower than the specified value for a given period of time or longer. - Troubleshooting Guides: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fusing unit. 4 Change MFPB. 5 Change DCPU.
- Code: 0511
- Display: FUSER ERROR
- Description: Abnormally low fusing pressure roller temperature
• The temperature detected by the thermistor /2 remains lower than the specified value for a given period of time or longer. - Troubleshooting Guides: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fusing unit. 4 Change MFPB. 5 Change DCPU.
- Code: 0520
- Display: FUSER ERROR
- Description: Abnormally high heating roller temperature
• The temperature detected by the thermistor /1 remains higher than the specified value for a given period of time or longer.
• The heater lamp remains ON for a given period of time or longer. - Troubleshooting Guides: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fusing unit. 4 Change MFPB. 5 Change DCPU.
- Code: 0521
- Display: FUSER ERROR
- Description: Abnormally high fusing pressure roller temperature
• The temperature detected by the thermistor /2 remains higher than the specified value for a given period of time or longer - Troubleshooting Guides: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fusing unit. 4 Change MFPB. 5 Change DCPU.
- Code: 0B30
- Display: FINISHER ERROR
- Description: Finisher aligning plate drive malfunction
- Troubleshooting Guides:
- Code: 0B47
- Display: FINISHER ERROR
- Description: Finisher media holding drive malfunction
- Troubleshooting Guides:
- Code: 0B48
- Display: FINISHER ERROR
- Description: Finisher exit roller pressure/retraction malfunction
- Troubleshooting Guides:
- Code: 0B4A
- Display: FINISHER ERROR
- Description: Finisher aligning belt pressure/retraction malfunction
- Troubleshooting Guides:
- Code: 0B4C
- Display: FINISHER ERROR
- Description: Finisher media ejector motor malfunction
- Troubleshooting Guides:
- Code: 0BA0
- Display: FINISHER ERROR
- Description: Finisher tray up/down motor ascent/descent drive malfunction
- Troubleshooting Guides:
- Code: 0BE1
- Display: FINISHER ERROR
- Description: Finisher fan motor malfunction
- Troubleshooting Guides:
- Code: 0F52
- Display: TE SENSOR Y
- Description: Toner level sensor /Y malfunction
• An error occurs on the toner level sensor board (TLSB). - Troubleshooting Guides: 1 Check the TLSB and MFPB for proper connection and correct as necessary. 2 Change TLSB. 3 Change MFPB.
- Code: 0F53
- Display: TE SENSOR M
- Description: Toner level sensor /M malfunction
• An error occurs on the toner level sensor board (TLSB). - Troubleshooting Guides: 1 Check the TLSB and MFPB for proper connection and correct as necessary. 2 Change TLSB. 3 Change MFPB.
- Code: 0F54
- Display: TE SENSOR C
- Description: Toner level sensor /C malfunction
• An error occurs on the toner level sensor board (TLSB). - Troubleshooting Guides: 1 Check the TLSB and MFPB for proper connection and correct as necessary. 2 Change TLSB. 3 Change MFPB.
- Code: 0F55
- Display: TE SENSOR K
- Description: Toner level sensor /K malfunction
• An error occurs on the toner level sensor board (TLSB). - Troubleshooting Guides: 1 Check the TLSB and MFPB for proper connection and correct as necessary. 2 Change TLSB. 3 Change MFPB.
- Code: 133B
- Display: FINISHERE COMMUNICATION
- Description: Finisher communication error
• A communication error occurs between the main body and the finisher. - Troubleshooting Guides: 1 Reboot the main body. 2 Change FSCB. 3 Change MFPB.
- Code: 13C0
- Display: ENGINE H/W ERROR
- Description: MFP board malfunction
• A communication error occurs in MFP board (MFPB). - Troubleshooting Guides: 1 Reboot the main body. 2 Change MFPB.
- Code: 13E2
- Display: FLASH WRITE
- Description: Flash ROM write error
• Flash ROM writing is found faulty during a check. - Troubleshooting Guides: 1 Check the MFPB for proper connection and correct as necessary. 2 Change PRCB. 3 Change MFPB.
- Code: 13E3
- Display: FLASH DEVICE
- Description: Flash ROM device fault
• An erase error occurs during erasing of data in flash ROM. - Troubleshooting Guides: 1 Check the MFPB for proper connection and correct as necessary. 2 Change PRCB. 3 Change MFPB.
- Code: 3C00
- Display: EEPROM1
- Description: Trouble related to security
• Contact the responsible people of KONICA MINOLTA when not returning in power switch OFF/ON. - Troubleshooting Guides:
- Code: 3C10
- Display: EEPROM2
- Description: Trouble related to security
• Contact the responsible people of KONICA MINOLTA when not returning in power switch OFF/ON. - Troubleshooting Guides:
- Code: 3FFB
- Display: FINISHER ROM
- Description: Finisher flash ROM error
• An error occurs with flash ROM of the optional staple finisher. - Troubleshooting Guides: 1 Check the FSCB for proper connection and correct as necessary. 2 Change FSCB.
- Code: C002
- Display: RAM ERROR
- Description: RAM error at startup (standard memory)
• RAM error at standard memory is detected during printer start-up. - Troubleshooting Guides: 1 Reboot the main body. 2 Check connection state of the standard/ expanded memory and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 Change the standard/expanded memory. 5 Change PRCB.
- Code: C003
- Display: RAM ERROR
- Description: RAM error at startup (expanded memory)
• RAM error at expanded memory is detected during printer start-up. - Troubleshooting Guides: 1 Reboot the main body. 2 Check connection state of the standard/ expanded memory and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 Change the standard/expanded memory. 5 Change PRCB.
- Code: C013
- Display: H/W ADDRESS
- Description: MAC address error at startup
• Invalid MAC address is detected during printer start-up. - Troubleshooting Guides: 1 Reboot the main body. 2 Check the PRCB connector for proper connection and correct as necessary. 3 Change PRCB.
- Code: C015
- Display: BOOT ROM
- Description: Boot ROM error at startup
• Boot ROM error is detected during printer startup. - Troubleshooting Guides: 1 Reboot the main body. 2 Check the PRCB connector for proper connection and correct as necessary. 3 Change PRCB.
- Code: C025
- Display: CONTROLLER ROM
- Description: Controller ROM error (Configuration information error)
• Lead error of destination setting file is detected during the printer starting. - Troubleshooting Guides:
- Code: C026
- Display: CONTROLLER ROM
- Description: Controller ROM error (Access error)
• Flash ROM access error is detected during the printer starting. - Troubleshooting Guides: 1 Reboot the main body. 2 Check the PRCB connector for proper connection and correct as necessary. 3 If this error message is displayed after update of firmware, conduct the firmware update procedures again. 4 Change PRCB.
Solve Konica-Minolta bizhub C30P Error codes
- Code: C027
- Display: CONTROLLER ROM
- Description: Controller ROM error (Data error)
• Final check sum error is detected during the printer starting. - Troubleshooting Guides: 1 Reboot the main body. 2 Check the PRCB connector for proper connection and correct as necessary. 3 If this error message is displayed after update of firmware, conduct the firmware update procedures again. 4 Change PRCB.
- Code: C050
- Display: HDD ERROR
- Description: HDD access error
• When correct access to the hard disk kit is failed during access. - Troubleshooting Guides: 1 Reboot the main body. 2 Check the HDD connector for proper connection and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 Change HDD. 5 Change PRCB.
- Code: C051
- Display: HDD DISK FULL
- Description: HDD full error
• Range for user space is full during access to the hard disk kit. - Troubleshooting Guides: 1 Reboot the main body. 2 Delete the job hold in “PROOF/PRINT MENU” to increase the available range for user space. 3 Check the HDD connector for proper connection and correct as necessary. 4 Format HDD with “SYS DEFAULT MENU/ HDD FORMAT.” 5 Change HDD.
- Code: C052
- Display: CARD ERROR
- Description: Compact flash access error
• When correct access to the compact flash card is failed during access. - Troubleshooting Guides: 1 Reboot the main body. 2 Check the compact flash for proper connection and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 Change compact flash. 5 Change PRCB.
- Code: C053
- Display: CARD FULL
- Description: Compact flash full error
• Range for user space is full during access to the compact flash card. - Troubleshooting Guides: 1 Reboot the main body. 2 Check the compact flash for proper connection and correct as necessary. 3 Change compact flash.pr
- Code: C060
- Display: UPDATE ERROR
- Description: Firmware update error
• Firmware update fails to complete correctly during update. - Troubleshooting Guides: 1 Reboot the main body. 2 Check the cable that has been used for update of the firmware for proper connection and correct as necessary. 3 Check the firmware update file and if the file is not the correct one, update the firmware again. 4 Check the firmware update procedure and if the procedure is not correct, update the firmware again. 5 Update the firmware again. . . 6 Check the PRCB connector for proper connection and correct as necessary. 7 Change PRCB.
- Code: C071
- Display: H/W CONFIG ERROR
- Description: Hardware configuration error
• An error occurs with hardware configuration (video clock etc.). - Troubleshooting Guides: 1 Reboot the main body. 2 Check the PRCB connector for proper connection and correct as necessary. 3 Change PRCB.
- Code: FFFF
- Display: I/F COMM ERROR
- Description: Interface Communication error
• Correct communication is failed when receiving/ sending the command between MFPB and PRCB. - Troubleshooting Guides: 1 Reboot the main body. 2 Check the PRCB connector for proper connection and correct as necessary 3 Check the MFPB connector for proper connection and correct as necessary. 4 Change MFPB. 5 Change PRCB.
– Get more error code list with quick guide to fix printer product, click here
– About get help with reseting Epson inkpad or others, click here
– Get more information about Epson XP 15000 troubleshooting, click here
– Buy cheap key of Epson WIC Reset Tool, CLICK HERE
– Key Epson Adjustment Program, CLICK HERE
– Download Epson printer driver, CLICK HERE
– Download Epson XP-6100 Driver, Firmware and Manuals, CLICK HERE
Contact us to get support with Konica-Minolta bizhub C30P Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.