[SOLVED] Quick fix Konica-Minolta 5450 list error codes
– Compatible Printer model: Konica-Minolta Magicolor 5450
– Konica-Minolta Magicolor 5450 Error Codes with quick guides:
- Code: 0010
- Display: P MOTOR COLOR
- Description: Color PC Drum Motor malfunction
• The Color PC Drum Motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The Motor Lock signal remains HIGH for a given period of consecutive time while the Color PC Drum Motor is being rotated. - Troubleshooting Guides: 1 Check the M2 connector for proper connection and correct as necessary. 2 Check M2 for proper drive coupling and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M2 operation check PWB-A PJ14A-8 (LOCK) PWB-A PJ14A-5 (REM) 11-B. 5 Change PWB-A. 6 Change LV.
- Code: 0017
- Display: P MOTOR BLACK
- Description: Intermediate Transport Motor malfunction
• The Intermediate Transport Motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The Motor Lock signal remains HIGH for a given period of consecutive time while the Intermediate Transport Motor is being rotated. - Troubleshooting Guides: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check M3 for proper drive coupling and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M3 operation check PWB-A PJ27A-8 (LOCK) PWB-A PJ27A-5 (REM) 2-I. 5 Change PWB-A. 6 Change LV.
- Code: 0018
- Display: D MOTOR BLACK
- Description: Developing Motor/K malfunction
• The Developing Motor/K does not rotate evenly even after the lapse of a given period of time while it is being started. • The Motor Lock signal remains HIGH for a given period of consecutive time while the Developing Motor/K is being rotated. - Troubleshooting Guides: 1 Check the M5 connector for proper connection and correct as necessary. 2 Check M5 for proper drive coupling and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M5 operation check PWB-A PJ33A-8 (LOCK) PWB-A PJ33A-5 (REM) 11-C. 5 Change PWB-A. 6 Change LV.
- Code: 001B
- Display: D MOTOR COLOR
- Description: Developing Motor/ Y,M,C malfunction
• The Developing Motor/Y,M,C does not rotate evenly even after the lapse of a given period of time while it is being started. • The Motor Lock signal remains HIGH for a given period of consecutive time while the Developing Motor/Y,M,C is being rotated. - Troubleshooting Guides: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M1 operation check PWB-A PJ8A-8 (LOCK) PWB-A PJ8A-5 (REM) 11-A. 5 Change PWB-A. 6 Change LV.
- Code: 0046
- Display: FUSER FAN
- Description: Fusing Cooling Fan Motor malfunction
• The Motor Lock signal remains HIGH for a given period of consecutive time while the Fusing Cooling Fan Motor is being rotated. - Troubleshooting Guides: 1 Check the M11 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M11 operation check PWB-A PJ21A-3 (LOCK) PWB-A PJ21A-1 (ON) 2-F-E 4 Change PWB-A.
- Code: 004C
- Display: OZONE FAN
- Description: Ozone Ventilation Fan Motor malfunction
• The Motor Lock signal remains HIGH for a given period of consecutive time while the Ozone Ventilation Fan Motor is being rotated. - Troubleshooting Guides: 1 Check the M12 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M12 operation check PWB-A PJ6A-7 (LOCK) PWB-A PJ6A-5 (ON) 14-I. 4 Change PWB-A.
- Code: 004E
- Display: POWER FAN
- Description: LV Cooling Fan Motor malfunction
• The Motor Lock signal remains HIGH for a given period of consecutive time while the LV Cooling Fan Motor is being rotated. - Troubleshooting Guides: 1 Check the M10 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M10 operation check PWB-A PJ9A-3 (LOCK) PWB-A PJ9A-1 (ON) 12-J. 4 Change PWB-A.
- Code: 0060
- Display: FUSER MOTOR
- Description: Fusing Motor malfunction
• The Fusing Motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The Motor Lock signal remains HIGH for a given period of consecutive time while the Fusing Motor is being rotated. - Troubleshooting Guides: 1 Check the M4 connector for proper connection and correct as necessary. 2 Check the Fusing Unit driving mechanism for possible overload and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M4 operation check PWB-A PJ19A-8 (LOCK) PWB-A PJ19A-5 (REM) 2-B-C 5 Change PWB-A.
- Code: 0094
- Display: XFER DETACH 2
- Description: 2nd image transfer pressure / retraction failure
• The Retraction Position Sensor/2nd Image Transfer is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd Transfer Roller has been started. • The Retraction Position Sensor/2nd Image Transfer is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd Transfer Roller has been started. - Troubleshooting Guides: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL5 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL5 for proper drive coupling and correct as necessary. 5 Check the PWB-A connector for proper connection and correct as necessary. 6 PC10 sensor check PWB-A PJ10A-6 (ON) 7-A. 7 CL5 operation check PWB-A PJ10A-8 (ON) 7-A. 8 M3 operation check PWB-A PJ27A-8 (LOCK) PWB-A PJ27A-5 (REM) 2-I. 9 Change PWB-A.
- Code: 0096
- Display: XFER DETACH 1
- Description: 1st image transfer pressure / retraction failure
• The Retraction Position Sensor/1st Image Transfer is not activated (retracted position) within a given period of time after the Intermediate Transport Motor has started rotating. • The Retraction Position Sensor/1st Image Transfer is not deactivated (pressed position) within a given period of time after the Intermediate Transport Motor has started rotating. - Troubleshooting Guides: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL4 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL4 for proper drive coupling and correct as necessary. 5 Check the PWB-A connector for proper connection and correct as necessary. 6 PC9 sensor check PWB-A PJ7A-13 (ON) 7-B-C. 7 CL4 operation check PWB-A PJ7A-10 (ON) 7-B. 8 M3 operation check PWB-A PJ27A-8 (LOCK) PWB-A PJ27A-5 (REM) 2-I. 9 Change PWB-A.
- Code: 0300
- Display: POLYGON MOTOR
- Description: Polygon Motor malfunction
• The Polygon Motor does not rotate evenly even after the lapse of a given period of time after it has been started. • The Motor Lock signal remains HIGH for a given period of consecutive time while the Polygon Motor is being rotated. - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-A.
- Code: 0310
- Display: LASER ERROR
- Description: Laser malfunction
• The SOS signal is not detected within a given period of time after the output of the laser has been started. - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-A.
- Code: 0500
- Display: FUSER ERROR
- Description: Heating Roller warm-up failure
• The Heating Roller Thermistor does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started. - Troubleshooting Guides: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
- Code: 0501
- Display: FUSER ERROR
- Description: Fusing Pressure Roller warm-up failure
• The Fusing Pressure Roller Thermistor does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started. - Troubleshooting Guides: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
- Code: 0510
- Display: FUSER ERROR
- Description: Abnormally low Heating Roller temperature
• The temperature detected by the Heating Roller Thermistor remains lower than the specified value for a given period of time or longer. - Troubleshooting Guides: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
- Code: 0511
- Display: FUSER ERROR
- Description: Abnormally low Fusing Pressure Roller temperature
• The temperature detected by the Fusing Pressure Roller Thermistor remains lower than the specified value for a given period of time or longer. - Troubleshooting Guides: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
- Code: 0520
- Display: FUSER ERROR
- Description: Abnormally high Heating Roller temperature
• The temperature detected by the Heating Roller Thermistor remains higher than the specified value for a given period of time or longer. - Troubleshooting Guides: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
- Code: 0521
- Display: FUSER ERROR
- Description: Abnormally high Fusing Pressure Roller temperature
• The temperature detected by the Fusing Pressure Roller Thermistor remains higher than the specified value for a given period of time or longer. - Troubleshooting Guides: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
- Code: 13D0
- Display: EEPROM1
- Description: Parameter Chip failure
• Data, which has been written, is read, checked, and found faulty; rewriting of the data is then executed and the data is checked to be found faulty during re-reading. • A count value is found faulty during reading. • Parameter Chip is detected to be not mounted during initial mounting detecting sequence. • Found to be access failure. - Troubleshooting Guides: 1 Unplug the power cord and plug it in, then turn OFF and ON the Power Switch. 2 Check Parameter Chip (IC15) on PWB-A for proper connection and correct as necessary. 3 Change PWB-A. 4 Change Parameter Chip.
- Code: 13E2
- Display: FLASH WRITE
- Description: Flash ROM write error
• Flash ROM writing is found faulty during a check. - Troubleshooting Guides: 1 Change PWB-A.
- Code: 13E3
- Display: FLASH DEVICE
- Description: Flash ROM device fault • An erase error occurs during erasing of data in Flash ROM.
- Troubleshooting Guides: 1 Change PWB-A.
- Code: C002
- Display: RAM
- Description: RAM error at Standard Memory
• RAM error at Standard Memory is detected during printer start-up. - Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check connection state of the extension memory and correct as necessary. 3 Check the PWB-P connector for proper connection and correct as necessary. 4 Changethe extension memory. 5 Change PWB-P.
- Code: C003
- Display: ERROR
- Description: RAM error at Extension Memory
• RAM error at Extension Memory is detected during printer start-up. - Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check connection state of the extension memory and correct as necessary. 3 Check the PWB-P connector for proper connection and correct as necessary. 4 Changethe extension memory. 5 Change PWB-P.
- Code: C013
- Display: H/W ADDRESS
- Description: MAC address error
• Invalid Mac address is detected during printer start-up. - Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check the PWB-P connector for proper connection and correct as necessary. 3 Change PWB-P.A.
- Code: C015
- Display: BOOT ROM
- Description: Boot ROM error
• Boot ROM error is detected during printer startup. - Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check the PWB-P connector for proper connection and correct as necessary. 3 Change PWB-P.A.
- Code: C022
- Display: NVRAM ERROR
- Description: NVRAM access error
• Correct access to NVRAM is failed during the printer starting. - Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check the PWB-P connector for proper connection and correct as necessary. 3 Change PWB-P.A.
- Code: C025
- Display: NVRAM ERROR
- Description: NVRAM access error
• Lead error of destination setting file is detected during the printer starting. - Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check the PWB-P connector for proper connection and correct as necessary. 3 If this error message is displayed after update of firmware, conduct the firmware update procedures again. 4 Change PWB-P.
- Code: C026
- Display: CONTROLLER ROM
- Description: Controller ROM error
• Flash ROM access error is detected during the printer starting. - Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check the PWB-P connector for proper connection and correct as necessary. 3 If this error message is displayed after update of firmware, conduct the firmware update procedures again. 4 Change PWB-P.
- Code: C027
- Display: CONTROLLER ROM
- Description: Controller ROM error
• Final check sum error is detected during the printer starting. - Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check the PWB-P connector for proper connection and correct as necessary. 3 If this error message is displayed after update of firmware, conduct the firmware update procedures again. 4 Change PWB-P.
- Code: C050
- Display: HDD ERROR
- Description: HDD access error
• When correct access to the hard disc unit is failed during access. - Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check the HDD connector for proper connection and correct as necessary. 3 Check the PWB-P connector for proper connection and correct as necessary. 4 Change HDD. 5 Change PWB-P
- Code: C051
- Display: HDD DISK FULL
- Description: HDD full error
• Range for user space is full during access to the Hard Disk unit. - Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Delete the job hold in “PROOF/PRINT MENU” to increase the available range for user space. 3 Check the HDD connector for proper connection and correct as necessary. 4 Format HDD with SYS DEFAULT MENU/HDD FORMAT. 5 Change HDD.
- Code: C060
- Display: UPDATE ERROR
- Description: Firmware update error
• Firmware update fails to complete correctly during update. - Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check the cable that has been used for update of the firmware for proper connection and correct as necessary. 3 Update the firmware again. 4 Check the PWB-P connector for proper connection and correct as necessary. 5 Change PWB-P
- Code: C061
- Display: HOLD JOB ERROR DUPLEX
- Description: Hold job error/No Duplex unit
• The Duplex Option is not installed, but it is required for printing the job held in the HDD. - Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Return to the same state as the device configuration when job was held. 3 Check the options that are mounted on the printer for proper connection and correct as necessary. 4 Check the PWB-A connector for proper connection and correct as necessary. 5 Delete the job hold in PROOF/PRINT MENU.
- Code: C062
- Display: HOLD JOB ERROR TRAY 3
- Description: Hold job error/No Tray 3
• Tray 3 is not set when the tray 3 is required for printing of the job hold in HDD. - Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Return to the same state as the device configuration when job was held. 3 Check the options that are mounted on the printer for proper connection and correct as necessary. 4 Check the PWB-A connector for proper connection and correct as necessary. 5 Delete the job hold in PROOF/PRINT MENU.
- Code: C063
- Display: HOLD JOB ERROR TRAY 4
- Description: Hold job error/No Tray 4
• Tray 4 is not set when the tray 4 is required for printing of the job hold in HDD. - Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Return to the same state as the device configuration when job was held. 3 Check the options that are mounted on the printer for proper connection and correct as necessary. 4 Check the PWB-A connector for proper connection and correct as necessary. 5 Delete the job hold in PROOF/PRINT MENU.
- Code: C064
- Display: HOLD JOB ERROR MEMORY
- Description: Hold job error/No Memory
• Expansion memory is not set when the expansion memory is required for printing of the job hold in HDD. - Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Return to the same state as the device configuration when job was held. 3 Check the options that are mounted on the printer for proper connection and correct as necessary. 4 Check the PWB-A connector for proper connection and correct as necessary. 5 Delete the job hold in PROOF/PRINT MENU.
- Code: FFFF
- Display: I/F COMM ERROR
- Description: Interface Communication error
• Correct communication is failed when receiving/ sending the command between PWB-A and PWB-P. - Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check the PWB-P connector for proper connection and correct as necessary 3 Check the PWB-A connector for proper connection and correct as necessary. 4 Change PWB-A.
Solve Konica-Minolta Magicolor 5450 Error codes
– Get more error code list with quick guide to fix printer product, click here
– About get help with reseting Epson inkpad or others, click here
– Get more information about Epson XP 15000 troubleshooting, click here
– Buy cheap key of Epson WIC Reset Tool, CLICK HERE
– Key Epson Adjustment Program, CLICK HERE
– Download Epson printer driver, CLICK HERE
– Download Epson XP-6100 Driver, Firmware and Manuals, CLICK HERE
Contact us to get support with Konica-Minolta Magicolor 5450 Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.