– Compatible Printer model: Konica-Minolta Magicolor 5430DL
– Konica-Minolta Magicolor 5430DL Error Codes with quick guides:
- Code: 0010H
- Description: Color PC Drum Motor malfunction
• The Color PC Drum Motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The Motor Lock signal remains HIGH for a given period of consecutive time while the Color PC Drum Motor is being rotated. - Troubleshooting Guides: 1 Check the M2 connector for proper connection and correct as necessary. 2 Check M2 for proper drive coupling and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M2 operation check PWB-A PJ14A-8 (LOCK) PWB-A PJ14A-5 (REM) 11-B. 5 Change PWB-A. 6 Change LV.
- Code: 0017H
- Description: Intermediate Transport Motor malfunction
• The Intermediate Transport Motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The Motor Lock signal remains HIGH for a given period of consecutive time while the Intermediate Transport Motor is being rotated. - Troubleshooting Guides: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check M3 for proper drive coupling and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M3 operation check PWB-A PJ27A-8 (LOCK) PWB-A PJ27A-5 (REM) 2-I. 5 Change PWB-A. 6 Change LV.
- Code: 0018H
- Description: Developing Motor/K malfunction
• The Developing Motor/K does not rotate evenly even after the lapse of a given period of time while it is being started. • The Motor Lock signal remains HIGH for a given period of consecutive time while the Developing Motor/K is being rotated. - Troubleshooting Guides: 1 Check the M5 connector for proper connection and correct as necessary. 2 Check M5 for proper drive coupling and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M5 operation check PWB-A PJ33A-8 (LOCK) PWB-A PJ33A-5 (REM) 11-C. 5 Change PWB-A. 6 Change LV.
- Code: 001BH
- Description: Developing Motor/Y,M,C malfunction
• The Developing Motor/Y,M,C does not rotate evenly even after the lapse of a given period of time while it is being started. • The Motor Lock signal remains HIGH for a given period of consecutive time while the Developing Motor/Y,M,C is being rotated. - Troubleshooting Guides: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M1 operation check PWB-A PJ8A-8 (LOCK) PWB-A PJ8A-5 (REM) 11-A/ 5 Change PWB-A. 6 Change LV.
- Code: 0046H
- Description: Fusing Cooling Fan Motor malfunction
• The Motor Lock signal remains HIGH for a given period of consecutive time while the Fusing Cooling Fan Motor is being rotated. - Troubleshooting Guides: 1 Check the M11 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M11 operation check PWB-A PJ21A-3 (LOCK) PWB-A PJ21A-1 (ON) 2-F-E 4 Change PWB-A.
- Code: 004CH
- Description: Ozone Ventilation Fan Motor malfunction
• The Motor Lock signal remains HIGH for a given period of consecutive time while the Ozone Ventilation Fan Motor is being rotated. - Troubleshooting Guides: 1 Check the M12 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M12 operation check PWB-A PJ6A-7 (LOCK) PWB-A PJ6A-5 (ON) 14-I. 4 Change PWB-A.
- Code: 004EH
- Description: LV Cooling Fan Motor malfunction
• The Motor Lock signal remains HIGH for a given period of consecutive time while the LV Cooling Fan Motor is being rotated. • The Fusing Motor does not rotate evenly even after the lapse of a given period of time while it is being started. - Troubleshooting Guides: 1 Check the M10 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M10 operation check PWB-A PJ9A-3 (LOCK) PWB-A PJ9A-1 (ON) 12-J. 4 Change PWB-A.
- Code: 0060H
- Description: Fusing Motor malfunction
• The Motor Lock signal remains HIGH for a given period of consecutive time while the Fusing Motor is being rotated. - Troubleshooting Guides: 1 Check the M4 connector for proper connection and correct as necessary. 2 Check the Fusing Unit driving mechanism for possible overload and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M4 operation check PWB-A PJ19A-8 (LOCK) PWB-A PJ19A-5 (REM) 2-B-C 5 Change PWB-A.
- Code: 0094H
- Description: 2nd image transfer pressure/ retraction failure
• The Retraction Position Sensor/2nd Image Transfer is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd Transfer Roller has been started. • The Retraction Position Sensor/2nd Image Transfer is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd Transfer Roller has been started. - Troubleshooting Guides: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL5 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL5 for proper drive coupling and correct as necessary. 5 Check the PWB-A connector for proper connection and correct as necessary. 6 PC10 sensor check PWB-A PJ10A-6 (ON) 7-A. 7 CL5 operation check PWB-A PJ10A-8 (ON) 7-A. 8 M3 operation check PWB-A PJ27A-8 (LOCK) PWB-A PJ27A-5 (REM) 2-I. 9 Change PWB-A.
- Code: 0096H
- Description: 1st image transfer pressure/ retraction failure
• The Retraction Position Sensor/1st Image Transfer is not activated (retracted position) within a given period of time after the Intermediate Transport Motor has started rotating. • The Retraction Position Sensor/1st Image Transfer is not deactivated (pressed position) within a given period of time after the Intermediate Transport Motor has started rotating. - Troubleshooting Guides: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL4 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL4 for proper drive coupling and correct as necessary. 5 Check the PWB-A connector for proper connection and correct as necessary. 6 PC9 sensor check PWB-A PJ7A-13 (ON) 7-B-C. 7 CL4 operation check PWB-A PJ7A-10 (ON) 7-B. 8 M3 operation check PWB-A PJ27A-8 (LOCK) PWB-A PJ27A-5 (REM) 2-I. 9 Change PWB-A.
- Code: 0300H
- Description: Polygon Motor malfunction
• The Polygon Motor does not rotate evenly even after the lapse of a given period of time after it has been started. • The Motor Lock signal remains HIGH for a given period of consecutive time while the Polygon Motor is being rotated. - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-A.
- Code: 0310H
- Description: Laser malfunction
• The SOS signal is not detected within a given period of time after the output of the laser has been started. - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-A.
- Code: 0500H
- Description: Heating Roller warm-up failure
• The Heating Roller Thermistor does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started. - Troubleshooting Guides: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
- Code: 0501H
- Description: Fusing Pressure Roller warm-up failure
• The Fusing Pressure Roller Thermistor does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started. - Troubleshooting Guides: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
- Code: 0510H
- Description: Abnormally low Heating Roller temperature
• The temperature detected by the Heating Roller Thermistor remains lower than the specified value for a given period of time or longer. - Troubleshooting Guides: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
- Code: 0511H
- Description: Abnormally low Fusing Pressure Roller temperature
• The temperature detected by the Fusing Pressure Roller Thermistor remains lower than the specified value for a given period of time or longer. - Troubleshooting Guides: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
- Code: 0520H
- Description: Abnormally high Heating Roller temperature
• The temperature detected by the Heating Roller Thermistor remains higher than the specified value for a given period of time or longer. - Troubleshooting Guides: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
- Code: 0521H
- Description: Abnormally high Fusing Pressure Roller temperature
• The temperature detected by the Fusing Pressure Roller Thermistor remains higher than the specified value for a given period of time or longer. - Troubleshooting Guides: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
- Code: 13D0H
- Description: Parameter Chip failure
• Data, which has been written, is read, checked, and found faulty; rewriting of the data is then executed and the data is checked to be found faulty during re-reading. • A count value is found faulty during reading. • Parameter Chip is detected to be not mounted during initial mounting detecting sequence. • Found to be access failure. - Troubleshooting Guides: 1 Unplug the power cord and plug it in, then turn OFF and ON the Power Switch. 2 Check Parameter Chip (IC15) on PWB-A for proper connection and correct as necessary. 3 Change PWB-A. 4 Change Parameter Chip.
- Code: 13E2H
- Description: Flash ROM write error
• Flash ROM writing is found faulty during a check. - Troubleshooting Guides: 1 Change PWB-A.
- Code: 13E3H
- Description: Flash ROM device fault
• An erase error occurs during erasing of data in Flash ROM. - Troubleshooting Guides: 1 Change PWB-A.
- Code: C002
- Description: RAM error
- Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check connection state of the extension memory and correct as necessary. 3 Check the PWB-P connector for proper connection and correct as necessary. 4 Changethe extension memory. 5 Change PWB-P.
- Code: C003
- Description: RAM error
- Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check connection state of the extension memory and correct as necessary. 3 Check the PWB-P connector for proper connection and correct as necessary. 4 Changethe extension memory. 5 Change PWB-P.
- Code: C013
- Description: MAC address
- Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check the PWB-P connector for proper connection and correct as necessary. 3 Change PWB-P.
- Code: C015
- Description: BOOT ROM error
- Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check the PWB-P connector for proper connection and correct as necessary. 3 Change PWB-P.
- Code: C022
- Description: NVRAM error
- Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check the PWB-P connector for proper connection and correct as necessary. 3 Change PWB-P.
- Code: C025
- Description: Controller ROM error
- Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check the PWB-P connector for proper connection and correct as necessary. 3 If this error message is displayed after update of firmware, conduct the firmware update procedures again. 4 Change PWB-P.
- Code: C026
- Description: Controller ROM error
- Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check the PWB-P connector for proper connection and correct as necessary. 3 If this error message is displayed after update of firmware, conduct the firmware update procedures again. 4 Change PWB-P.
- Code: C027
- Description: Controller ROM error
- Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check the PWB-P connector for proper connection and correct as necessary. 3 If this error message is displayed after update of firmware, conduct the firmware update procedures again. 4 Change PWB-P.
- Code: C050
- Description: Hard disk access error
- Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check the HDD connector for proper connection and correct as necessary. 3 Check the PWB-P connector for proper connection and correct as necessary. 4 Change HDD. 5 Change PWB-P.
- Code: C051
- Description: Hard disk full error
- Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Delete the job hold in PROOF/PRINT MENU to increase the available range for user space. 3 Check the HDD connector for proper connection and correct as necessary. 4 Format HDD with “SYS DEFAULT MENU/HDD FORMAT. 5 Change HDD.
- Code: C060
- Description: Firmware Update error
- Troubleshooting Guides: 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer.) 2 Check the cable that has been used for update of the firmware for proper connection and correct as necessary. 3 Update the firmware again. 4 Check the PWB-P connector for proper connection and correct as necessary. 5 Change PWB-P.
Solve Konica-Minolta Magicolor 5430DL Error codes
– Get more error code list with quick guide to fix printer product, click here
– About get help with reseting Epson inkpad or others, click here
– Get more information about Epson XP 15000 troubleshooting, click here
– Buy cheap key of Epson WIC Reset Tool, CLICK HERE
– Key Epson Adjustment Program, CLICK HERE
– Download Epson printer driver, CLICK HERE
– Download Epson XP-6100 Driver, Firmware and Manuals, CLICK HERE
Contact us to get support with Konica-Minolta Magicolor 5430DL Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.