[SOLVED] Quick fix Konica-Minolta 4650EN list error codes
– Compatible Printer model: Konica-Minolta Magicolor 4650EN
– Konica-Minolta Magicolor 4650EN Error Codes with quick guides:
- Code: 0010
- Display: P MOTOR 1
- Description: Color PC drum motor malfunction
• The color PC drum motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the color PC drum motor is being rotated. - Troubleshooting Guides: 1 Check the M2 connector for proper connection and correct as necessary. 2 Check M2 for proper drive coupling and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 M2 operation check MFPB PJ11MFPB-8 to 14 J-2. 5 Change M2. 6 Change MFPB. 7 Change DCPU.
- Code: 0017
- Display: P MOTOR 2
- Description: Transport motor malfunction
• The transport motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the transport motor is being rotated. - Troubleshooting Guides: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check M3 for proper drive coupling and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 M3 operation check MFPB PJ11MFPB-1 to 7 J-3. 5 Change M3. 6 Change MFPB. 7 Change DCPU.
- Code: 0018
- Display: D MOTOR 2
- Description: K developing motor malfunction
• The K developing motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the K developing motor is being rotated. - Troubleshooting Guides: 1 Check the M5 connector for proper connection and correct as necessary. 2 Check M5 for proper drive coupling and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 M5 operation check MFPB PJ8MFPB-8 to 14 J-4. 5 Change M5. 6 Change MFPB. 7 Change DCPU.
- Code: 001B
- Display: D MOTOR 1
- Description: Color developing motor malfunction
• The color developing motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the color developing motor is being rotated. - Troubleshooting Guides: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check the MFPB connector for proper connection and correct as necessary. 3 M1 operation check. 4 Change driving unit. 5 Change MFPB. 6 Change DCPU.
- Code: 0046
- Display: FUSER FAN
- Description: Fusing fan motor malfunction
• The fusing fan motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the fusing fan motor is being rotated. - Troubleshooting Guides: 1 Check the FM2 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM2 operation check MFPB PJ21MFPB-3 (LOCK) C-10. 4 Change FM2. 5 Change MFPB.
- Code: 004A
- Display: DUPLEX FAN
- Description: Duplex cooling fan motor malfunction
• The duplex cooling fan motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the duplex cooling fan motor is being rotated. - Troubleshooting Guides: 1 Check the FM4 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM4 operation check MFPB PJ27MFPB-6 (LOCK) C-2 4 Change FM4. 5 Change MFPB.
- Code: 004C
- Display: OZONE FAN
- Description: Ozone ventilation fan motor malfunction
• The ozone ventilation fan motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the ozone ventilation fan motor is being rotated. - Troubleshooting Guides: 1 Check the FM3 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM3 operation check MFPB PJ31MFPB-3 (LOCK) C-11. 4 Change FM3. 5 Change MFPB.
- Code: 004E
- Display: POWER FAN
- Description: DC power supply fan motor malfunction
• The DC power supply fan motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the DC power supply fan motor is being rotated. - Troubleshooting Guides: 1 Check the FM1 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM1 operation check MFPB PJ9MFPB-3 (LOCK) C-10 to 11. 4 Change FM1. 5 Change MFPB.
- Code: 0060
- Display: FUSER MOTOR
- Description: Fusing motor malfunction
• The fusing motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the fusing motor is being rotated. - Troubleshooting Guides: 1 Check the M4 connector for proper connection and correct as necessary. 2 Check the fuser unit driving mechanism for possible overload and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 M4 operation check MFPB PJ19MFPB-3 to 9 J-3. 5 Change M4. 6 Change MFPB.
- Code: 0094
- Display: XFER DETACH 2
- Description: 2nd image transfer pressure / retraction failure
• The 2nd image transfer retraction position sensor is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd transfer roller has been started. • The 2nd image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd transfer roller has been started. - Troubleshooting Guides: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL5 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL5 for proper drive coupling and correct as necessary. 5 Check the MFPB connector for proper connection and correct as necessary. 6 PS10 sensor check MFPB PJ16MFPB-8 (ON) C-4 7 CL5 operation check MFPB PJ10MFPB-5 (ON) C-6 8 M3 operation check MFPB PJ11MFPB-1 to 7 J-3 9 Change M3. 10 Change CL5. 11 Change MFPB.
- Code: 0096
- Display: XFER DETACH 1
- Description: 1st image transfer pressure / retraction failure
• The 1st image transfer retraction position sensor is not activated (retracted position) within a given period of time after the intermediate transport motor has started rotating. • The 1st image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the intermediate transport motor has started rotating. - Troubleshooting Guides: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL4 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL4 for proper drive coupling and correct as necessary. 5 Check the MFPB connector for proper connection and correct as necessary. 6 PS9 sensor check MFPB PJ7MFPB-11 (ON) J-5. 7 CL4 operation check MFPB PJ19MFPB-2 (REM) J-3 to 4. 8 M3 operation check MFPB PJ11MFPB-1 to 7 J-3. 9 Change M3. 10 Change CL4. 11 Change MFPB.
- Code: 0300
- Display: POLYGON MOTOR
- Description: Polygon motor malfunction
• The polygon motor does not rotate evenly even after the lapse of a given period of time after it has been started. • The motor lock signal remains HIGH for a given period of consecutive time while the polygon motor is being rotated. - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change MFPB.
- Code: 0310
- Display: LASER ERROR
- Description: Laser malfunction
• The SOS signal is not detected within a given period of time after the output of the laser has been started. - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change MFPB.
- Code: 0500
- Display: FUSER ERROR
- Description: Heating roller warm-up failure
• The thermistor /1 does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started. - Troubleshooting Guides: 1 Check the fuser unit for correct installation (whether it is secured in position). 2 Check the fuser unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fuser unit. 4 Change MFPB. 5 Change DCPU.
- Code: 0502
- Display: TERMISTOR1
- Description: Thermistor open-circuit failure
• The temperature detected by the thermistor does not reach a predetermined level even after the lapse of a given period time after the warm-up cycle has been started. - Troubleshooting Guides: 1 Check the fuser unit for correct installation (whether it is secured in position). 2 Check the fuser unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fuser unit. 4 Change MFPB. 5 Change DCPU.
- Code: 0503
- Display: TERMISTOR2
- Description: Thermistor resistance failure
• The difference between the temperature detected by thermistor/1 and that detected by thermistor/2 exceeds a predetermined value. - Troubleshooting Guides: 1 Check the fuser unit for correct installation (whether it is secured in position). 2 Check the fuser unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fuser unit. 4 Change MFPB. 5 Change DCPU.
- Code: 0510
- Display: FUSER ERROR
- Description: Abnormally low heating roller temperature
• The temperature detected by the thermistor /1 remains lower than the specified value for a given period of time or longer. - Troubleshooting Guides: 1 Check the fuser unit for correct installation (whether it is secured in position). 2 Check the fuser unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fuser unit. 4 Change MFPB. 5 Change DCPU.
- Code: 0520
- Display: FUSER ERROR
- Description: Abnormally high heating roller temperature
• The temperature detected by the thermistor /1 remains higher than the specified value for a given period of time or longer. • The heater lamp remains ON for a given period of time or longer. - Troubleshooting Guides: 1 Check the fuser unit for correct installation (whether it is secured in position). 2 Check the fuser unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fuser unit. 4 Change MFPB. 5 Change DCPU.
- Code: 0F50
- Display: PT SENSOR
- Description: OHP sensor malfunction
• It is determined that the OHP sensor is faulty through a check made at the end of the predrive. - Troubleshooting Guides: 1 Check the MFPB connector for proper connection and correct as necessary. 2 PS7 sensor check MFPB PJ15MFPB-5 (ON) C-5. 3 Change MFPB.
- Code: 0F52
- Display: TE SENSOR Y
- Description: Toner level sensor /Y malfunction
• An error occurs on the toner level sensor board (TLSB). - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change TLSB. 3 Change MFPB.
- Code: 0F53
- Display: TE SENSOR M
- Description: Toner level sensor /M malfunction
• An error occurs on the toner level sensor board (TLSB). - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change TLSB. 3 Change MFPB.
- Code: 0F54
- Display: TE SENSOR C
- Description: Toner level sensor /C malfunction
• An error occurs on the toner level sensor board (TLSB). - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change TLSB. 3 Change MFPB.
- Code: 0F55
- Display: TE SENSOR K
- Description: Toner level sensor /K malfunction
• An error occurs on the toner level sensor board (TLSB). - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change TLSB. 3 Change MFPB.
- Code: 13C0
- Display: ENGINE H/W ERROR
- Description: MFP board malfunction
• A communication error occurs in MFP board (MFPB). - Troubleshooting Guides: 1 Reboot the main body. 2 Change MFPB.
- Code: 13DD
- Display: EEPROM BK
- Description: Backup data error
• The printer determines that EEPROM is yet to be mounted when the main power switch is turned ON. - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PRCB. 3 Change MFPB.
- Code: 13E2
- Display: FLASH WRITE
- Description: Flash ROM write error
• Flash ROM writing is found faulty during a check. - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PRCB. 3 Change MFPB.
- Code: 13E3
- Display: FLASH DEVICE
- Description: Flash ROM device fault
• An erase error occurs during erasing of data in flash ROM. - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PRCB. 3 Change MFPB.
- Code: 13F0
- Display: ENGINE ERR
- Description: Engine control failure
• An undefined malfunction occurs in the engine section (PRCB, etc.). - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PRCB. 3 Change MFPB.
- Code: 3C00
- Display: EEPROM1
- Description: Trouble related to security
- Troubleshooting Guides:
- Code: 3C10
- Display: EEPROM2
- Description: Trouble related to security
- Troubleshooting Guides:
- Code: C003
- Display: RAM ERROR
- Description: RAM error at startup (expanded memory)
• RAM error at expanded memory is detected during printer start-up. - Troubleshooting Guides: 1 Reboot the main body. 2 Check connection state of the standard/ expanded memory and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 Change the expanded memory. 5 Change PRCB.
- Code: C013
- Display: H/W ADDRESS
- Description: MAC address error at startup
• Invalid MAC address is detected during printer start-up - Troubleshooting Guides: 1 Reboot the main body. 2 Check the PRCB connector for proper connection and correct as necessary. 3 Change PRCB.
- Code: C015
- Display: BOOT ROM
- Description: Boot ROM error at startup
• Boot ROM error is detected during printer startup. - Troubleshooting Guides: 1 Reboot the main body. 2 Check the PRCB connector for proper connection and correct as necessary. 3 Change PRCB.
- Code: C025
- Display: CONTROLLER ROM
- Description: Controller ROM error (Configuration information error)
• Lead error of destination setting file is detected during the printer starting. - Troubleshooting Guides: 1 Reboot the main body. 2 Check the PRCB connector for proper connection and correct as necessary. 3 If this error message is displayed after update of firmware, conduct the firmware update procedures again. 4 Change PRCB.
- Code: C026
- Display: CONTROLLER ROM
- Description: Controller ROM error (Access error)
• Flash ROM access error is detected during the printer starting. - Troubleshooting Guides: 1 Reboot the main body. 2 Check the PRCB connector for proper connection and correct as necessary. 3 If this error message is displayed after update of firmware, conduct the firmware update procedures again. 4 Change PRCB.
- Code: C027
- Display: CONTROLLER ROM
- Description: Controller ROM error (Data error)
• Final check sum error is detected during the printer starting. - Troubleshooting Guides: 1 Reboot the main body. 2 Check the PRCB connector for proper connection and correct as necessary. 3 If this error message is displayed after update of firmware, conduct the firmware update procedures again. 4 Change PRCB.
- Code: C050
- Display: HDD ERROR
- Description: HDD access error
• When correct access to the hard disk kit is failed during access. - Troubleshooting Guides: 1 Reboot the main body. 2 Check the HDD connector for proper connection and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 Change HDD. 5 Change PRCB.
- Code: C051
- Display: HDD DISK FULL
- Description: HDD full error
• Range for user space is full during access to the hard disk kit. - Troubleshooting Guides: 1 Reboot the main body. 2 Delete the job hold in [PROOF/PRINT MENU] to increase the available range for user space. 3 Check the HDD connector for proper connection and correct as necessary. 4 Format HDD with [SYS DEFAULT MENU]- [HDD FORMAT.] 5 Change HDD.
- Code: C052
- Display: CARD ERROR
- Description: Compact flash access error
• When correct access to the compact flash card is failed during access. - Troubleshooting Guides: 1 Reboot the main body. 2 Check the compact flash for proper connection and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 Change compact flash. 5 Change PRCB.
- Code: C053
- Display: CARD FULL
- Description: Compact flash full error
• Range for user space is full during access to the compact flash card. - Troubleshooting Guides: 1 Reboot the main body. 2 Delete the job hold in [PROOF/PRINT MENU] to increase the available range for user space. 3 Check the compact flash for proper connection and correct as necessary. 4 Format compact flash with [SYS DEFAULT MENU]-[CARD FORMAT.] 5 Change compact flash.
- Code: C060
- Display: UPDATE ERROR
- Description: Firmware update error
• Firmware update fails to complete correctly during update. - Troubleshooting Guides: 1 Reboot the main body. 2 Check the cable that has been used for update of the firmware for proper connection and correct as necessary. 3 Check the firmware update file and if the file is not the correct one, update the firmware again. 4 Check the firmware update procedure and if the procedure is not correct, update the firmware again. 5 Update the firmware again. . . 6 Check the PRCB connector for proper connection and correct as necessary. 7 Change PRCB.
- Code: C071
- Display: H/W CONFIG ERROR
- Description: Hardware configuration error
• An error occurs with hardware configuration (video clock etc.). - Troubleshooting Guides: 1 Reboot the main body. 2 Check the PRCB connector for proper connection and correct as necessary. 3 Change PRCB.
Solve Konica-Minolta Magicolor 4650EN Error codes
- Code: FFFF
- Display: I/F COMM ERROR
- Description: Interface Communication error
• Correct communication is failed when receiving/ sending the command between MFPB and PRCB. - Troubleshooting Guides: 1 Reboot the main body. 2 Check the PRCB connector for proper connection and correct as necessary 3 Check the MFPB connector for proper connection and correct as necessary. 4 Change MFPB. 5 Change PRCB.
– Get more error code list with quick guide to fix printer product, click here
– About get help with reseting Epson inkpad or others, click here
– Get more information about Epson XP 15000 troubleshooting, click here
– Buy cheap key of Epson WIC Reset Tool, CLICK HERE
– Key Epson Adjustment Program, CLICK HERE
– Download Epson printer driver, CLICK HERE
– Download Epson XP-6100 Driver, Firmware and Manuals, CLICK HERE
Contact us to get support with Konica-Minolta Magicolor 4650EN Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.