[SOLVED] Quick fix Konica-Minolta 2550 list error codes
– Compatible Printer model: Konica-Minolta Magicolor 2550
– Konica-Minolta Magicolor 2550 Error Codes with quick guides:
- Code: 04
- Description: Printer control board malfunction
• Communications with the M/C expansion IO G/A (IC on the printer control board) are not properly carried out. - Troubleshooting Guides: 1 Check the PRCB connector for proper connection and correct as necessary. 2 Change PRCB.
- Code: 05
- Description: Flash ROM malfunction
• Firmware upgrading has failed. - Troubleshooting Guides: 1 Check the PRCB connector for proper connection and correct as necessary. 2 Change PRCB.
- Code: 08
- Description: Main motor malfunction
• The motor lock signal remains HIGH for a predetermined consecutive period of time while the main motor remains energized. • The motor lock signal remains LOW for a predetermined consecutive period of time while the main motor remains deenergized. - Troubleshooting Guides: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M1 operation check. 2500W: PRCB PJ8PRCB-5 (REM) PRCB PJ8PRCB-8 (LOCK) 2530 DL: PRCB PJ8PRCB-5(REM) PRCB PJ8PRCB-5(LOCK) 2550/2550DN: PRCB PJ8PRCB-5(REM) PRCB PJ8PRCB-5(LOCK) 2500W: C-7 2530 DL: C-6 2550/2550DN: C-6. 5 Change PRCB. 6 Change DCPU.
- Code: 0B
- Description: Ventilation fan motor malfunction
• The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the ventilation fan motor remains energized. - Troubleshooting Guides: 1 Check the FM2 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 FM2 operation check. 2500W: PRCB PJ10PRCB-1 (REM) PRCB PJ10PRCB-3 (LOCK) 2530 DL: PRCB PJ10PRCB-1(REM) PRCB PJ8PRCB-3(LOCK) 2550/2550DN: PRCB PJ10PRCB-1(REM) PRCB PJ8PRCB-3(LOCK) 2500W: C-6 2530 DL: C-5 2550/2550DN: C-5. 5 Change PRCB. 6 Change DCPU.
- Code: 0C
- Description: Power supply cooling fan motor malfunction
• The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the power supply cooling fan motor remains energized. - Troubleshooting Guides: 1 Check the FM1 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 FM1 operation check. 2500W: PRCB PJ4PRCB-1 (REM) PRCB PJ4PRCBB-3 (LOCK) 2530 DL: PRCB PJ4PRCB-1 (REM) PRCB PJ4PRCB-3 (LOCK) 2550/2550DN: PRCB PJ4PRCB-1 (REM) PRCB PJ4PRCB-3 (LOCK) 2500W: C-5 2530 DL: C-4 2550/2550DN: C-4. 5 Change PRCB. 6 Change DCPU.
- Code: 0F
- Description: Cooling fan motor malfunction
- Troubleshooting Guides:
- Code: 10
- Description: Polygon motor malfunction
• A LOW motor lock signal is not detected even after the lapse of a predetermined period of time after the polygon motor has been started. • The motor lock signal remains HIGH for a predetermined consecutive period of time while the polygon motor remains energized. - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change PRCB.
- Code: 12
- Description: Laser malfunction
• The SOS signal is not detected within a predetermined period of time after the output of a laser has been started. • The SOS signal is never detected in the image area. - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change PRCB.
- Code: 14
- Description: 2nd image transfer pressure /retraction failure
• The state of the retraction position sensor/2nd image transfer is not changed from the unblocked to blocked state even after the lapse of a predetermined period of time during predrive. • The retraction position sensor/2nd image transfer is in the unblocked state even after the lapse of a predetermined period of time during predrive. • The retraction position sensor/2nd image transfer is not blocked (roller in the retracted position) within a predetermined period of time after the retraction sequence of the 2nd transfer roller has been started. • The retraction position sensor/2nd image transfer is not unblocked (roller in the pressed position) within a predetermined period of time after the pressure sequence of the 2nd transfer roller has been started. - Troubleshooting Guides: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the SD4 connector for proper connection and correct as necessary. 4 Check the PRCB connector for proper connection and correct as necessary. 5 PS5 sensor check. 2500W: PRCB PJ14PRCB-3 (ON) 2530 DL: PRCB PJ14PRCB-3 (ON) 2550/2550DN: PRCB PJ14PRCB-3 (ON) 2500W: J-4 2530 DL: J-3 2550/2550DN: J-3 6 SD4 operation check. 2500W: PRCB PJ11PRCB-2 (REM) 2530 DL: PRCB PJ11PRCB-2 (REM) 2550/2550DN: PRCB PJ11PRCB-2 (REM) 2500W: C-11 2530 DL: C-10 2550/2550DN: C-10. 7 M1 operation check. 2500W: PRCB PJ8PRCB-5 (REM) PRCB PJ8PRCB-8 (LOCK) 2530 DL: PRCB PJ8PRCB-5(REM) PRCB PJ8PRCB-5(LOCK) 2550/2550DN: PRCB PJ8PRCB-5(REM) PRCB PJ8PRCB-5(LOCK) 2500W: C-7 2530 DL: C-6 2550/2550DN: C-6. 8 Change PRCB.
- Code: 15
- Description: Cleaning blade pressure /retraction failure
• The state of the retraction position sensor/cleaning blade is not changed from the blocked to unblocked state even after the lapse of a predetermined period of time during predrive. • The retraction position sensor/cleaning blade is in the blocked state even after the lapse of a predetermined period of time during predrive. • The retraction position sensor/cleaning blade is not unblocked (blade in the retracted position) within a predetermined period of time after the retraction sequence of the cleaning blade has been started. • The retraction position sensor/cleaning blade is not blocked (blade in the pressed position) within a predetermined period of time after the pressure sequence of the cleaning blade has been started. - Troubleshooting Guides: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the SD3 connector for proper connection and correct as necessary. 4 Check the PRCB connector for proper connection and correct as necessary. 5 PS6 sensor check. 2500W: PRCB PJ9PRCB-11 (ON) 2530 DL: PRCB PJ9PRCB-11 (ON) 2550/2550DN: PRCB PJ9PRCB-11 (ON) 2500W: C-7 2530 DL: C-6 2550/2550DN: C-6. 6 SD3 operation check. 2500W: PRCB PJ10PRCB-5 (REM) 2530 DL: PRCB PJ10PRCB-5 (REM) 2550/2550DN: PRCB PJ10PRCB-5 (REM) 2500W: C-6 2530 DL: C-5 2550/2550DN: C-5 7 M1 operation check. 2500W: PRCB PJ8PRCB-5 (REM) PRCB PJ8PRCB-8 (LOCK) 2530 DL: PRCB PJ8PRCB-5(REM) PRCB PJ8PRCB-5(LOCK) 2550/2550DN: PRCB PJ8PRCB-5(REM) PRCB PJ8PRCB-5(LOCK) 2500W: C-7 2530 DL: C-6 2550/2550DN: C-6. 8 Change PRCB.
- Code: 16
- Description: Transfer belt rotation failure
• The belt positioning sensor does not detect the transfer belt position detection hole a second time even after the lapse of a predetermined period of time after it has detected one while the transfer belt is rotated. - Troubleshooting Guides: 1 Check the PRCB connector for proper connection and correct as necessary. 2 PS4 sensor check. 2500W: PRCB PJ9PRCB-8 (ON) 2530 DL: PRCB PJ9PRCB-8 (ON) 2550/2550DN: PRCB PJ9PRCB-8 (ON) 2500W: C-8 2530 DL: C-6 2550/2550DN: C-6. 3 Change transfer belt unit. 4 Change PRCB.
- Code: 17
- Description: Rack rotation failure
• The rack positioning sensor is in the blocked state when the rack motor remains deenergized. • The rack positioning sensor is not blocked a second time even after the lapse of a predetermined period of time after it has been blocked once while the rack motor remains energized. • The rack positioning sensor is unable to detect the deceleration control position after the lapse of a given period of time after the rack motor has started while the rack motor is turning. • The count value of the edge of ON signal of the rack positioning sensor during each developing positions are not a predetermined value while the rack motor is turning. - Troubleshooting Guides: 1 Check the M2 connector for proper connection and correct as necessary. 2 Check M2 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 PS3 sensor check. 2500W: PRCB PJ5PRCB-11 (ON) 2530 DL: PRCB PJ5PRCB-11 (ON) 2550/2550DN: PRCB PJ5PRCB-11 (ON) 2500W: C-8 2530 DL: C-7 2550/2550DN: C-7. 5 M2 operation check. 2500W: PRCB PJ5PRCB-1?«4 (Pulse Output) 2530 DL: PRCB PJ5PRCB-1?«4 (Pulse Output) 2550/2550DN: PRCB PJ5PRCB-1?«4 (Pulse Output) 2500W: C-9 2530 DL: C-8 2550/2550DN: C-8. 6 Change PRCB.
- Code: 18
- Description: Heating roller warm-up failure
• The thermistor does not detect a predetermined temperature value even after the lapse of a predetermined period of time after the current warm-up cycle has been started and the current warm-up cycle is thus not completed. - Troubleshooting Guides: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, PDCU, and PRCB for proper connection and correct as necessary. 3 check the lever of the safety switch and correct as necessary. 4 change the fusing unit. 5 Change PRCB. 6 Change PDCU.
- Code: 19
- Description: Abnormally low heating roller temperature
• The temperature detected by the thermistor remains lower than a predetermined value for a predetermined period of time. - Troubleshooting Guides: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, PDCU, and PRCB for proper connection and correct as necessary. 3 check the lever of the safety switch and correct as necessary. 4 change the fusing unit. 5 Change PRCB. 6 Change PDCU.
- Code: 1A
- Description: Abnormally high heating roller temperature
• The temperature detected by the thermistor is a predetermined value or higher for a predetermined period of time. - Troubleshooting Guides: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, PDCU, and PRCB for proper connection and correct as necessary. 3 check the lever of the safety switch and correct as necessary. 4 change the fusing unit. 5 Change PRCB. 6 Change PDCU.
- Code: 1B
- Description: Faulty thermistor
• The condition of a temperature rise of less than 1°C extends continuously for a predetermined period of time that begins when the warm-up cycle is started. - Troubleshooting Guides: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, PDCU, and PRCB for proper connection and correct as necessary. 3 check the lever of the safety switch and correct as necessary. 4 change the fusing unit. 5 Change PRCB. 6 Change PDCU.
- Code: 21
- Description: Faulty OHP sensor
• It is determined that the OHP sensor is faulty through a check made at the end of the predrive. - Troubleshooting Guides: 1 Check the PRCB connector for proper connection and correct as necessary. 2 PS2 sensor check. 2500W: PRCB PJ12PRCB-6 (ON) 2530 DL: PRCB PJ12PRCB-6 (ON) 2550/2550DN: PRCB PJ12PRCB-6 (ON) 2500W: C-10 2530 DL: C-9 2550/2550DN: C-9. 3 Change PRCB.
- Code: 24
- Description: Faulty fusing thermistor resistor
• The heater lamp remains ON for a predetermined consecutive period of time. - Troubleshooting Guides: 1 Check the PRCB connector for proper connection and correct as necessary. 2 Change fusing unit. 3 Change PRCB.
- Code: 29
- Description: Trouble related to security
- Troubleshooting Guides:
- Code: 2A
- Description: Trouble related to security
- Troubleshooting Guides:
- Code: 2B
- Description: Trouble related to security
- Troubleshooting Guides:
- Code: 2C
- Description: Trouble related to security
- Troubleshooting Guides:
Solve Konica-Minolta Magicolor 2550 Error codes
– Get more error code list with quick guide to fix printer product, click here
– About get help with reseting Epson inkpad or others, click here
– Get more information about Epson XP 15000 troubleshooting, click here
– Buy cheap key of Epson WIC Reset Tool, CLICK HERE
– Key Epson Adjustment Program, CLICK HERE
– Download Epson printer driver, CLICK HERE
– Download Epson XP-6100 Driver, Firmware and Manuals, CLICK HERE
Contact us to get support with Konica-Minolta Magicolor 2550 Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.