- Code: 04H
- Description: Mechanical Control Board malfunction
• Communications with the M/C expansion IO G/A (IC on the Mechanical Control Board) are not properly carried out. - Troubleshooting Guides: 1 Check the PWB-A connector for proper connection and correct as necessary. 2 Change PWB-A.
- Code: 05H
- Description: Flash ROM malfunction
• Firmware upgrading has failed. - Troubleshooting Guides: 1 Check the PWB-A connector for proper connection and correct as necessary. 2 Change PWB-A.
- Code: 08H
- Description: Main Motor malfunction
• The Motor Lock signal remains HIGH for a predetermined consecutive period of time while the Main Motor remains energized. • The Motor Lock signal remains LOW for a predetermined consecutive period of time while the Main Motor remains deenergized. - Troubleshooting Guides: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M1 operation check. PWB-A PJ8A-5 (REM) PWB-A PJ8A-8 (LOCK) 2-G-H 5 Change PWB-A. 6 Change PU.
- Code: 0BH
- Description: Ventilation Fan Motor malfunction
• The Fan Motor Lock signal remains HIGH for a predetermined consecutive period of time while the Ventilation Fan Motor remains energized. - Troubleshooting Guides: 1 Check the M6 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M6 operation check. PWB-A PJ10A-1 (REM) PWB-A PJ10A-3 (LOCK) 2-H. 5 Change PWB-A. 6 Change PU.
- Code: 0CH
- Description: Power Supply Cooling Fan Motor malfunction
• The Fan Motor Lock signal remains HIGH for a predetermined consecutive period of time while the Power Supply Cooling Fan Motor remains energized. - Troubleshooting Guides: 1 Check the M4 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M4 operation check. PWB-A PJ4A-1 (REM) PWB-A PJ4A-3 (LOCK) 7-D. 5 Change PWB-A. 6 Change PU.U.
- Code: 10H
- Description: Polygon Motor malfunction
• A LOW Motor Lock signal is not detected even after the lapse of a predetermined period of time after the Polygon Motor has been started. • The Motor Lock signal remains HIGH for a predetermined consecutive period of time while the Polygon Motor remains energized. - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-A.
- Code: 12H
- Description: Laser malfunction
• The SOS signal is not detected within a predetermined period of time after the output of a laser has been started. • The SOS signal is never detected in the image area. - Troubleshooting Guides: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-A.
- Code: 14H
- Description: 2nd image transfer pressure /retraction failure
• The state of the Retraction Position Sensor/2nd Image Transfer is not changed from the unblocked to blocked state even after the lapse of a predetermined period of time during predrive. • The Retraction Position Sensor/2nd Image Transfer is in the unblocked state even after the lapse of a predetermined period of time during predrive. • The Retraction Position Sensor/2nd Image Transfer is not blocked (roller in the retracted position) within a predetermined period of time after the retraction sequence of the 2nd Transfer Roller has been started. • The Retraction Position Sensor/2nd Image Transfer is not unblocked (roller in the pressed position) within a predetermined period of time after the pressure sequence of the 2nd Transfer Roller has been started. - Troubleshooting Guides: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the SL4 connector for proper connection and correct as necessary. 4 Check the PWB-A connector for proper connection and correct as necessary. 5 PC5 sensor check. PWB-A PJ14A-3 (ON) 2-G 6 SL4 operation check. PWB-A PJ11A-2 (REM) 2-G 7 M1 operation check. PWB-A PJ8A-5 (REM) PWB-A PJ8A-8 (LOCK) 2-G-H 8 Change PWB-A.
- Code: 15H
- Description: Cleaning Blade pressure /retraction failure
• The state of the Retraction Position Sensor/Cleaning Blade is not changed from the blocked to unblocked state even after the lapse of a predetermined period of time during predrive. • The Retraction Position Sensor/Cleaning Blade is in the blocked state even after the lapse of a predetermined period of time during predrive. • The Retraction Position Sensor/Cleaning Blade is not unblocked (blade in the retracted position) within a predetermined period of time after the retraction sequence of the Cleaning Blade has been started. • The Retraction Position Sensor/Cleaning Blade is not blocked (blade in the pressed position) within a predetermined period of time after the pressure sequence of the Cleaning Blade has been started. - Troubleshooting Guides: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the SL3 connector for proper connection and correct as necessary. 4 Check the PWB-A connector for proper connection and correct as necessary. 5 PC6 sensor check. PWB-A PJ9A-11 (ON) 2-F 6 SL3 operation check. PWB-A PJ10-5 (REM) 2-F 7 M1 operation check. PWB-A PJ8A-5 (REM) PWB-A PJ8A-8 (LOCK) 2-G-H 8 Change PWB-A.
- Code: 16H
- Description: Transfer Belt rotation failure
• The Belt Positioning Sensor does not detect the Transfer Belt position detection hole a second time even after the lapse of a predetermined period of time after it has detected one while the Transfer Belt is rotated. - Troubleshooting Guides: 1 Check the PWB-A connector for proper connection and correct as necessary. 2 PC4 sensor check. PWB-A PJ9A-8 (ON) 2-E. 3 Change Transfer Belt Unit. 4 Change PWB-A.
- Code: 17H
- Description: Rack rotation failure
• The Rack Positioning Sensor is in the blocked state when the Rack Motor remains deenergized. • The Rack Positioning Sensor is not blocked a second time even after the lapse of a predetermined period of time after it has been blocked once while the Rack Motor remains energized. • The Rack Positioning Sensor is unable to detect the• The count value of the edge of ON signal of the Rack Positioning Sensor during each developing positions are not a predetermined value while the Rack Motor is turning. deceleration control position after the lapse of a given period of time after the Rack Motor has started while the Rack Motor is turning. - Troubleshooting Guides: 1 Check the M2 connector for proper connection and correct as necessary. 2 Check M2 for proper drive coupling and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 PC3 sensor check. PWB-A PJ5A-11 (ON) 4-C 5 M2 operation check. PWB-A PJ5A-1-4 (Pulse Output) 4-B. 6 Change PWB-A.
- Code: 18H
- Description: Heating Roller warm-up failure
• The Thermistor does not detect a predetermined temperature value even after the lapse of a predetermined period of time after the current warm-up cycle has been started and the current warm-up cycle is thus not completed. - Troubleshooting Guides: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PU, and PWB-A for proper connection and correct as necessary. 3 Check the lever of the Safety Switch and correct as necessary. 4 Change the Fusing Unit. 5 Change PWB-A. 6 Change PU.
- Code: 19H
- Description: Abnormally low Heating Roller temperature
• The temperature detected by the Thermistor remains lower than a predetermined value for a predetermined period of time. - Troubleshooting Guides: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PU, and PWB-A for proper connection and correct as necessary. 3 Check the lever of the Safety Switch and correct as necessary. 4 Change the Fusing Unit. 5 Change PWB-A. 6 Change PU.
- Code: 1AH
- Description: Abnormally high Heating Roller temperature
• The temperature detected by the Thermistor is a predetermined value or higher for a predetermined period of time. - Troubleshooting Guides: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PU, and PWB-A for proper connection and correct as necessary. 3 Check the lever of the Safety Switch and correct as necessary. 4 Change the Fusing Unit. 5 Change PWB-A. 6 Change PU.
- Code: 1BH
- Description: Faulty Thermistor
• The condition of a temperature rise of less than 1°C extends continuously for a predetermined period of time that begins when the warm-up cycle is started. - Troubleshooting Guides: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PU, and PWB-A for proper connection and correct as necessary. 3 Check the lever of the Safety Switch and correct as necessary. 4 Change the Fusing Unit. 5 Change PWB-A. 6 Change PU.
- Code: 21H
- Description: Faulty OHP Sensor
• It is determined that the OHP Sensor is faulty through a check made at the end of the predrive. - Troubleshooting Guides: 1 Check the PWB-A connector for proper connection and correct as necessary. 2 PC2A sensor check. PWB-A PJ12A-6 (ON) 2-D. 3 Change PWB-A.
- Code: 23H
- Description: Faulty Waste Toner Near Full Detection Board
• It is determined that the LED and photoreceiver are faulty through a check made when a new Drum Cartridge is detected. - Troubleshooting Guides: 1 Check the PWB-C connector for proper connection and correct as necessary. 2 Check the PWB-A connector for proper connection and correct as necessary. 3 Change the Drum Cartridge. 4 Change PWB-C. 5 Change PWB-A.
- Code: 24H
- Description: Faulty Fusing Thermistor Resistor
• The Heater Lamp remains ON for a predetermined consecutive period of time. - Troubleshooting Guides:
- Code: 29H
- Description: Faulty memory counter
• It is determined that the life counter value is faulty when the parameter chip data is read as the Power Switch is turned ON. - Troubleshooting Guides: 1 Unplug the power cord and plug it in, then turn OFF and ON the Power Switch. 2 Check Parameter Chip (PJ26) on PWB-A for proper connection and correct as necessary. 3 Change PWB-A. 4 Change Parameter Chip.
- Code: 2AH
- Description: Faulty memory data
• It is determined that the parameter chip data is faulty when read. - Troubleshooting Guides: 1 Unplug the power cord and plug it in, then turn OFF and ON the Power Switch. 2 Check Parameter Chip (PJ26) on PWB-A for proper connection and correct as necessary. 3 Change PWB-A. 4 Change Parameter Chip.
- Code: 2BH
- Description: Memory access failure
• It is determined that there is a parameter chip data access failure. - Troubleshooting Guides: 1 Unplug the power cord and plug it in, then turn OFF and ON the Power Switch. 2 Check Parameter Chip (PJ26) on PWB-A for proper connection and correct as necessary. 3 Change PWB-A. 4 Change Parameter Chip.
- Code: 2CH
- Description: Memory mounting failure
• Mounting of the parameter chip on the Mechanical Control Board is faulty. - Troubleshooting Guides: 1 Unplug the power cord and plug it in, then turn OFF and ON the Power Switch. 2 Check Parameter Chip (PJ26) on PWB-A for proper connection and correct as necessary. 3 Change PWB-A. 4 Change Parameter Chip.
Solve Konica-Minolta Magicolor 2400W Error codes
– Get more error code list with quick guide to fix printer product, click here
– About get help with reseting Epson inkpad or others, click here
– Get more information about Epson XP 15000 troubleshooting, click here
– Buy cheap key of Epson WIC Reset Tool, CLICK HERE
– Key Epson Adjustment Program, CLICK HERE
– Download Epson printer driver, CLICK HERE
– Download Epson XP-6100 Driver, Firmware and Manuals, CLICK HERE
Contact us to get support with Konica-Minolta Magicolor 2400W Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.