[SOLVED] Quick fix Konica-Minolta 2350 list error codes
– Compatible Printer model: Konica-Minolta Magicolor 2350
– Konica-Minolta Magicolor 2350 Error Codes with quick guides:
- Code: 04
- Description: • If abnormal transmissions are detected in the master board (PWB-A)
- Troubleshooting Guides: 1 Replace PWB-A.
- Code: 08
- Description: • If the main motor (M1) does not rotate when the unit is turned on
- Troubleshooting Guides: 1 Check M1 operation. M1_REM 5-A. 3 Replace PU. 4 Replace PWB-A. 5 Replace PWB-P.
- Code: 0B
- Description: • If the ventilation fan motor (M6) does not rotate when the unit is turned on
- Troubleshooting Guides: 1 Check M6 operation. M6_REM 3-E. 2 Replace PU. 3 Replace PWB-A. 4 Replace PWB-P.
- Code: 0C
- Description: • If the power supply cooling fan motor does not rotate when the unit is turned on
- Troubleshooting Guides: 1 Check M4 operation. M4_REM 3-D. 2 Replace PU. 3 Replace PWB-A. 4 Replace PWB-P.
- Code: 0E
- Description: • If the fusing cooling fan motor does not rotate when the unit is turned on
- Troubleshooting Guides: 1 Check M5 operation. M5_REM 11-E. 2 Replace PU. 3 Replace PWB-A. 4 Replace PWB-P.
- Code: 10
- Description: • If the polygon motor does not rotate
- Troubleshooting Guides: 1 Replace the print head unit. 2 Replace PU. 3 Replace PWB-A. 4 Replace PWB-P.
- Code: 14
- Description: • If there is no pressure by or separation from the Second image transfer roller
- Troubleshooting Guides: 1 Check PC7 operation. 149 PC7_ON 5-C. 2 Replace the Second image transfer roller pressure/separation mechanisms. 3 Check SL2 operation. SL2_REM 5-E. 4 Replace PWB-A. 5 Replace PWB-P.
- Code: 15
- Description: • If there is no pressure by or separation from the transfer belt cleaner
- Troubleshooting Guides: 1 Check PC9 operation. PC9_ON 3-G. 2 Replace the belt cleaner pressure/ separation mechanisms. 3 Check SL4 operation. SL4_REM 2-H 4 Replace PWB-A. 5 Replace PWB-P.
- Code: 16
- Description: • If the transfer belt of the transport image transfer belt unit does not rotate
- Troubleshooting Guides: 1 Replace the image transfer belt unit.
- Code: 17
- Description: • If the toner cartridge does not rotate
- Troubleshooting Guides: 1 Check PC4 operation. PC4_ON 3-F. 2 Check CL1 operation. CL1_REM 2-F. 3 Check M2 operation 3-E. 4 Replace PWB-A. 5 Replace PWB-P.
- Code: 18
- Description: • If the unit does reach 80° C within 100 seconds from the time that warm-up begins • If the temperature of the fusing roller falls below 70° C in 10 seconds during standby • If the temperature of the fusing roller increases to 220°C in 0.1 second
- Troubleshooting Guides: 1 Check for continuity at H1 and H2. NO Replace H1 and H2. 2-B, 2-C 2 Check for continuity at TS1. NO Replace TS1. 2-C. 3 Is the resistance at TH1 infinite? (between CN18-1 and -2 on the thermistor) YES Clean TH1 or replace the fusing unit. HEATER 2-D NO Replace PU. Replace PWB-A.1
- Code: 19
- Description: • If the unit does reach 80° C within 100 seconds from the time that warm-up begins • If the temperature of the fusing roller falls below 70° C in 10 seconds during standby • If the temperature of the fusing roller increases to 220°C in 0.1 second
- Troubleshooting Guides: 1 Check for continuity at H1 and H2. NO Replace H1 and H2. 2-B, 2-C 2 Check for continuity at TS1. NO Replace TS1. 2-C. 3 Is the resistance at TH1 infinite? (between CN18-1 and -2 on the thermistor) YES Clean TH1 or replace the fusing unit. HEATER 2-D NO Replace PU. Replace PWB-A.1
- Code: 1A
- Description: • If the temperature of the fusing roller when the fusing unit begins warming up does not remain increased by 5°C for 1 second within the 40 to 50 seconds after the fusing roller begins warming up
- Troubleshooting Guides: 1 Is there a short circuit at TH1? (between CN18-1 and -2 on the thermistor) YES Clean TH1. HEATER 2-D Replace the fusing unit. NO Replace PU. Replace PWB-AP.
- Code: 1B
- Description: • If the temperature of the fusing roller when the fusing unit begins warming up does not remain increased by 5°C for 1 second within the 40 to 50 seconds after the fusing roller begins warming up
- Troubleshooting Guides: 1 Is there a short circuit at TH1? (between CN18-1 and -2 on the thermistor) YES Clean TH1. HEATER 2-D Replace the fusing unit. NO Replace PU. Replace PWB-AP.
- Code: 21
- Description: • If a overhead projector transparency is not detected
- Troubleshooting Guides: 1 Check PC3A operation. PC3_REM 5-D. 2 Replace PWB-A. 3 Replace PWB-P.
- Code: 29
- Description: • If the EEPROM malfunctioned
- Troubleshooting Guides: 1 Replace the EEPROM. 2 Replace PWB-A.
- Code: 2A
- Description: • If the EEPROM malfunctioned
- Troubleshooting Guides: 1 Replace the EEPROM. 2 Replace PWB-A.
- Code: 2B
- Description: • If the EEPROM malfunctioned
- Troubleshooting Guides: 1 Replace the EEPROM. 2 Replace PWB-A.
Solve Konica-Minolta Magicolor 2350 Error codes
– Get more error code list with quick guide to fix printer product, click here
– About get help with reseting Epson inkpad or others, click here
– Get more information about Epson XP 15000 troubleshooting, click here
– Buy cheap key of Epson WIC Reset Tool, CLICK HERE
– Key Epson Adjustment Program, CLICK HERE
– Download Epson printer driver, CLICK HERE
– Download Epson XP-6100 Driver, Firmware and Manuals, CLICK HERE
Contact us to get support with Konica-Minolta Magicolor 2350 Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.