[SOLVED] Quick fix Konica-Minolta 164 list error codes
– Compatible Printer model: Konica-Minolta bizhub 164
– Konica-Minolta bizhub 164 Error Codes with quick guides:
- Code: C0211
- Description: Bypass tray lift-up failure
– When a print cycle is completed, a jam is fixed, or the power switch is turned ON, if the bypass lift sensor (PS4) does not change from the unblocked to blocked condition after the lapse of a given period of time after the bypass pick-up solenoid (SD1) is turned ON, the machine retries the depressing motion. This trouble code is displayed if the PS4 is not blocked after the retry
– While the bypass lift sensor (PS4) is blocked, if the PS4 is not unblocked after the lapse of a given period of time after the bypass pick-up solenoid (SD1) is turned ON, the machine retries the lifting motion. This trouble code is displayed if the PS4 is not unblocked after the retry - Troubleshooting Guides: 1 Check the connector between M1-PRCB CN6 for proper connection and correct as necessary. 2 Check M1 for correct drive coupling and correct as necessary. 3 Check the connector between PS4-relay CN6-PRCB CN8 for proper connection and correct as necessary. 4 Check the connector between SD1-relay CN4-relay CN6-PRCB CN8 for proper connection and correct as necessary. 5 PS4 I/O check, sensor check. 6 M1 operation check. 7 SD1 operation check. 8 Change PRCB.
- Code: C2351
- Description: Suction fan motor malfunction
– The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary. - Troubleshooting Guides: 1 Check the connector between FM5-relay CN13-PRCB CN14 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM5 operation check. 4 Change PRCB.
- Code: C2557
- Description: Abnormally low T/C ratio
– The T/C ratios detected by the TCR sensor board (TCRSB) are below the threshold for the detection of abnormally low T/C ratio for three successive times. However, if a toner empty condition is detected, this abnormality is not detected. - Troubleshooting Guides: 1 Check to see if developer is available. 2 Check the connector between TCRSBrelay CN14-PRCB CN10 for proper connection and correct as necessary. 3 Change TCRSB. 4 Execute “TCR AUTO ADJUST. 5 Change PRCB.
- Code: C2558
- Description: Abnormally high T/C ratio
– The T/C ratios detected by the TCR sensor board (TCRSB) are above the threshold for the detection of abnormally high T/C ratio for three successive times.
– The connector between TCRSB to PRCC is disconnected - Troubleshooting Guides: 1 Check to see if developer is available. 2 Check the connector between TCRSBrelay CN14-PRCB CN10 for proper connection and correct as necessary. 3 Change TCRSB. 4 Execute “TCR AUTO ADJUST. 5 Change PRCB.
- Code: C255C
- Description: TCR sensor adjustment failure
– When AUTO ADJUST is performed, the difference between the TCR sensor output voltage determined by TCR AUTO ADJUST and the standard voltage is greater than the given value. - Troubleshooting Guides: 1 Check to see if developer is available. 2 Check the connector between TCRSBrelay CN14-PRCB CN10 for proper connection and correct as necessary. 3 Change TCRSB. 4 Execute “TCR AUTO ADJUST. 5 Change PRCB.
- Code: C2702
- Description: Abnormal image transfer voltage
– The image transfer voltage remains more than 100 V continuously for a given period of time while the drum remains stationary. - Troubleshooting Guides: 1 Check the transfer roller unit for installation. 2 Change HV1. 3 Change PRCB.
- Code: C3451
- Description: Warming-up failure
– The surface temperature of the fusing roller does not reach a given level even after the lapse of a given period of time during a warm-up cycle. - Troubleshooting Guides: 1 Check the fusing unit for correct installation. 2 Check the open/close operation of the right door. 3 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.
- Code: C3751
- Description: Fusing failure (abnormally high fusing temperature 1)
– The temperature detected by the thermistor/1 (TH1) remains higher than a given temperature for a given period of time. - Troubleshooting Guides: 1 Check the fusing unit for correct installation. 2 Check the open/close operation of the right door. 3 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.
- Code: C3752
- Description: Fusing failure (abnormally high fusing temperature 2)
– The temperature detected by the thermistor/1 (TH1) remains higher than a given temperature for a given period of time. - Troubleshooting Guides: 1 Check the fusing unit for correct installation. 2 Check the open/close operation of the right door. 3 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.
- Code: C3851
- Description: Fusing failure (abnormally low fusing temperature)
– The temperature detected by the thermistor/2 (TH2) remains higher than a given temperature for a given period of time. - Troubleshooting Guides: 1 Check the fusing unit for correct installation. 2 Check the open/close operation of the right door. 3 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.
- Code: C4001
- Description: Faulty HSYNC
– The SOS sensor does not detect a rising edge of SOS within a given period of time after the polygon motor has started turning and a laser output has been started.
– The SOS sensor detects no rising edges of SOS while VIA (image area control) is ON. - Troubleshooting Guides: 1 Turn OFF and ON the power switch. 2 Check the connector between PH unit- PRCB CN1, CN2 for proper connection and correct as necessary. 3 Change PH unit. 4 Change PRCB.
- Code: C4101
- Description: Polygon motor malfunction
– A HIGH polygon motor lock signal is not detected within a given period of time that begins 0.5 sec. after the polygon motor has started turning.
– A LOW polygon motor lock signal is not detected for a continuous given period of time while the rotation of the polygon motor remains stabilized. - Troubleshooting Guides: 1 Turn OFF and ON the power switch. 2 Check the connector between PH unit- PRCB CN1, CN2 for proper connection and correct as necessary. 3 Change PH unit. 4 Change PRCB.
- Code: C5102
- Description: Main motor malfunction
– The main motor (M1) lock signal remains HIGH for a continuous 1-sec. period at any time 1 sec. after the main motor has started turning. - Troubleshooting Guides: 1 Check the connector between M1-PRCB CN6 for proper connection and correct as necessary. 2 Check M1 for correct drive coupling and correct as necessary. 3 M1 operation check. 4 Change PRCB. 5 Change DCPU.
- Code: C6101
- Description: Scanner home detection failure
– When the power switch is turned ON or a scan operation is completed, detecting the home position fails. - Troubleshooting Guides: 1 Turn OFF and ON the power switch. 2 Check the connector between M4-PRCB P101 for proper connection and correct as necessary. 3 Check M4 for correct drive coupling and correct as necessary. 4 Check the connector between CIS-PRCB P102 for proper connection and correct as necessary. 5 M4 operation check 6 Change M4. 7 Change CIS 8 Change MFPB.
- Code: C9401
- Description: Scanner lamp error
– When the power switch is turned ON or a scan operation is completed, the light quantity is checked and the shading compensation is performed. At this time, trouble is detected. - Troubleshooting Guides: 1 Turn OFF and ON the power switch. 2 Check the connector between CIS-PRCB P102 for proper connection and correct as necessary. 3 Change CIS 4 Change MFPB.
- Code: CC102
- Description: Controller – engine connection failure
– The engine control system can not communicate with the controller. - Troubleshooting Guides: 1 Turn OFF and ON the power switch. 2 Change PRCB.
- Code: CC151
- Description: Flash ROM error
– The copier determines that there is an error if writing to the flash ROM fails during upgrading of the firmware.
– When the power switch is turned ON, the error indicator lights up steadily and a corresponding message appears on the display.
– If this error message appears, no operations can then be performed. It is not possible to upgrade the firmware from a PC connected through USB connection, either. - Troubleshooting Guides: 1 Check the PRCB connectors for proper connection and correct as necessary. 2 Identify the specific firmware that is responsible for the error. 3 Perform upgrading of the firmware. 4 Unplug EEPROM (R22) from PRCB and then plug it back in. 5 Change PRCB.
- Code: CC153
- Description: Engine flash ROM error
– Data of flash ROM of the engine control system is determined to be faulty. - Troubleshooting Guides: 1 Check the PRCB connectors for proper connection and correct as necessary. 2 Identify the specific firmware that is responsible for the error. 3 Perform upgrading of the firmware. 4 Unplug EEPROM (R22) from PRCB and then plug it back in. 5 Change PRCB.
- Code: CC163
- Description: Engine connection failure
– The controller can not communicate with the engine control system - Troubleshooting Guides: 1 Turn OFF and ON the power switch. 2 Check the PRCB connectors for proper connection and correct as necessary. 3 Change PRCB.
- Code: CD301
- Description: EEPROM error
– Contact the responsible people of KMBT before taking some countermeasures. - Troubleshooting Guides:
Solve Konica-Minolta bizhub 164 Error codes
– Get more error code list with quick guide to fix printer product, click here
– About get help with reseting Epson inkpad or others, click here
– Get more information about Epson XP 15000 troubleshooting, click here
– Buy cheap key of Epson WIC Reset Tool, CLICK HERE
– Key Epson Adjustment Program, CLICK HERE
– Download Epson printer driver, CLICK HERE
– Download Epson XP-6100 Driver, Firmware and Manuals, CLICK HERE
Contact us to get support with Konica-Minolta bizhub 164 Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.