[SOLVED] Quick fix Konica-Minolta 160 list error codes
– Compatible Printer model: Konica-Minolta bizhub 160
– Konica-Minolta bizhub 160 Error Codes with quick guides:
- Code: C0045
- Description: Fuser fan motor error
– The LOCK signal remains HIGH or LOW continuously for a predetermined period of time while the Cooling Fan Motor remains energized - Troubleshooting Guides: 1 Check the Motor connectors for connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M2 operation check 4 M3 operation check 5 Replace PWB-P.
- Code: C0210
- Description: H. V. abnormal
– The Drum Charge Monitor Voltage (HVC_MON) signal falls outside a predetermined range at any time after the lapse of a predetermined period of time after the Power Switch has been turned ON.
– The Image Transfer Voltage Monitor signal (T_MON_V) and Image Transfer Current Monitor signal (T_MON_I) fall outside a corresponding predetermined range - Troubleshooting Guides: 1 Replace Fusing Unit. 2 Replace PWB-P.
- Code: C0500
- Description: Fuser warm up error
– The voltage of the Thermistor remains low for a predetermined period of time when a warm-up cycle is started.
– The temperature detected by the Thermistor remains lower than a reference value for a predetermined period of time for the period of time that begins 5 sec. after, and ends 9 sec. after, the start of the warm-up cycle (where the temperature detected by the Thermistor is 80 °C or less).
– The temperature detected by the Thermistor does not increase for a 3-sec. period or more for the period of time that begins after the lapse of a predetermined period of time after the Fusing Roller Heater Lamp has been turned ON and ends when the lamp is turned OFF.
– The Fusing Roller Heater Lamp remains ON for a 30-sec. period or more (except during the period through which the Main Motor remains energized). - Troubleshooting Guides: 1 Replace Thermistor (TH1). 2 Replace Fusing Unit. 3 Replace Controller/Mechanical Control Board (PWB-P). 4 Replace Power Unit (PU1).
- Code: C0510
- Description: Fuser temperature low
– The temperature detected by the Thermistor remains lower than the set temperature continuously for a predetermined period of time while the fusing temperature control is being provided. (The set temperatures are as follows: 140 °C during a print mode at 600 dpi; 70 °C during the standby mode.) - Troubleshooting Guides: 1 Replace Thermistor (TH1). 2 Replace Fusing Unit. 3 Replace Controller/Mechanical Control Board (PWB-P). 4 Replace Power Unit (PU1).
- Code: C0520
- Description: Fuser overheat
– The temperature detected by the Thermistor remains higher than 235 °C for a predetermined period of time while the fusing temperature control is being provided. - Troubleshooting Guides: 1 Replace Thermistor (TH1). 2 Replace Fusing Unit. 3 Replace Controller/Mechanical Control Board (PWB-P). 4 Replace Power Unit (PU1).
- Code: C0650
- Description: Scanner home sensor error
– The Scanner Home Position Sensor is not detected within the predetermined period of time after the Scanner Motor has started turning. - Troubleshooting Guides: 1 M4 operation check. 2 Replace PWB-P.
- Code: C1200
- Description: ASIC memory abnormal
– An error occurred while writing to or reading the SRAM on the Control Board (PWB-C). - Troubleshooting Guides: 1 Turn the copier off, then on again. 2 Check the connection of the memory on the PWB-P, and then correct it if necessary. 3 Replace PWB-P.r unit.
- Code: C1300
- Description: Polygon mirror motor error
– The LOCK signal is not detected within a predetermined period of time that begins 1 sec. after the Polygon Motor has been energized.
– No new LOCK signal is detected for a 1-sec. period that begins 1.5 sec. after the first LOCK signal was detected.
– The LOCK signal is not detected for a continuous 0.5-sec. period in a state in which the Polygon Motor runs stably.
– The LOCK signal remains ON for a continuous 5-sec. period or more when the Polygon Motor remains deenergized. - Troubleshooting Guides: 1 Check cables for connection and correct as necessary. 2 Replace PH Unit. 3 Replace PWB-P.
- Code: C133B
- Description: Communication with option error
– Communication could not be established with the Controller Control Board within 5 seconds while printing. - Troubleshooting Guides:
- Code: C133C
- Description: Modem error
– A malfunction occurred in the Modem. - Troubleshooting Guides: 1 Replace NCU.
- Code: C133D
- Description: ROM checksum error
– A malfunction occurred in the ROM - Troubleshooting Guides: 1 Replace PWB-P.
- Code: C13F0
- Description: Laser error
– The laser output exceeds the upper limit value.
– The laser output remains lower than the lower limit value. - Troubleshooting Guides: 1 Check cables for connection and correct as necessary. 2 Replace PH Unit. 3 Replace PWB-P.
- Code: C1468
- Description: Parameter Chip error
– An Parameter Chip not written with initial data was detected. - Troubleshooting Guides: 1 Unplug, then plug in the power cord, and turn off the copier, then turn it on again. 2 Check the connection of the Parameter Chip on the PWBP, and then correct it if necessary. 3 Replace PWBP. 4 Replace Parameter Chip.
- Code: C14A3
- Description: IR lamp malfunction
– The luminosity level of the Exposure Lamp is not stabilized within the predetermined period of time. - Troubleshooting Guides: 1 Check the connection of the connectors, and then correct them if necessary. 2 Replace PWB-P. 3 Replace the Scanner Assy.
Solve Konica-Minolta bizhub 160 Error codes
– Get more error code list with quick guide to fix printer product, click here
– About get help with reseting Epson inkpad or others, click here
– Get more information about Epson XP 15000 troubleshooting, click here
– Buy cheap key of Epson WIC Reset Tool, CLICK HERE
– Key Epson Adjustment Program, CLICK HERE
– Download Epson printer driver, CLICK HERE
– Download Epson XP-6100 Driver, Firmware and Manuals, CLICK HERE
Contact us to get support with Konica-Minolta bizhub 160 Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.