Sharp MXB455WZ Printer with list Error Codes and Epson XP-220 Adjustment Program
– Printer model: Sharp MXB455WZ
– Error codes on Sharp MXB455WZ with details instruction fixing:
- Code: A0-01
- Description: PCU ROM error
- Causes: The firmware version up is not completed properly by interruption of the power during the version up operation
PCU PWB trouble - Troubleshooting Guides: SIM49-1 to execute the firmware version up
Replace PCU PWB
- Code: A0-02
- Description: SCN ROM error
- Causes: The firmware version up is not completed properly by interruption of the power during the version up operation.
SCN-cnt PWB trouble - Troubleshooting Guides: SIM49-1 to execute the firmware version up
Replace SCN-cnt PWB
- Code: A0-06
- Description: FAX ROM error
- Causes: The content of FAX ROM is abnormal
The firmware version up is not completed properly by interruption of the power during the version up operation.
MFPC PWB trouble - Troubleshooting Guides: SIM49-1 to execute the firmware version up
Replace MFPC PWB
- Code: A0-10
- Description: MFP ROM error
- Causes: The content of the color profile is abnormal
Combination inconsistency between MFP firmware and color profile - Troubleshooting Guides: SIM49-1 to execute the firmware version up
Replace MFP PWB
- Code: A0-15
- Description: Stored DSK data conflict
- Causes: Inconsistency of ASIC MAIN firmware version
- Troubleshooting Guides: Check ASIC MAIN firmware version
Check installation state of TPM PWB
Check installation state of EEPROM
- Code: A0-17
- Description: UI data error
- Causes: Inconsistency between UI contents and UI firmware version
- Troubleshooting Guides: SIM49-1 to execute the firmware version up
- Code: A0-18
- Description: ASIC MAIN firmware inconsistent error
- Causes: Inconsistency of ASIC firmware version in MFP
- Troubleshooting Guides: SIM49-1 to execute the firmware version
- Code: A0-19
- Description: MFP boot error
- Causes: ASIC trouble
Memory trouble - Troubleshooting Guides: Confirm eMMC connection
Check and replace the following parts separately (If not improving, replace parts will be returned to original parts once each time)
Replace MFPC PWB
Replace eMMC and MFPC PWB
- Code: A0-20
- Description: Conflict firmware and EEPROM data version( MFP)
- Causes: Inconsistency between MFP firmware version and EEPROM data version
- Troubleshooting Guides: SIM49-1 to execute the firmware version up
- Code: A0-21
- Description: Conflict firmware and EEPROM data version( PCU)
- Causes: Inconsistency between PCU firmware version and EEPROM data version
- Troubleshooting Guides: SIM49-1 to execute the firmware version up
- Code: A0-22
- Description: Conflict firmware and EEPROM data version( SCU)
- Causes: Inconsistency between SCN firmware version and EEPROM data version
- Troubleshooting Guides: SIM49-1 to execute the firmware version up
- Code: E6-10
- Description: Shading error(Black level) (SPF)
- Causes: CCD unit connector, harness connection trouble
CCD unit trouble
DSPF PWB trouble - Troubleshooting Guides: Check connection state of CCD unit connector, harness
Replace CCD unit
Replace DSPF PWB
- Code: E6-11
- Description: Shading error(White level) (SPF)
- Causes: CCD unit connector, harness connection trouble
Scanner lamp lighting trouble
Dirt on mirror, reference white plate
CCD unit trouble
DSPF PWB trouble - Troubleshooting Guides: Check connection state of CCD unit connector, harness
Check connection state of scanner lamp connector, harness
Clean the reference white plate
Replace CCD unit
Replace DSPF PWB
SIM63-2 to execute
- Code: E6-14
- Description: CCD-ASIC error(SPF)
- Causes: DSPF PWB trouble
- Troubleshooting Guides: Replace DSPF PWB
- Code: E7-01
- Description: Image data error
- Causes: Image data transfer error in MFPC PWB
MFPC PWB trouble - Troubleshooting Guides: Check connection state of MFPC PWB connector, harness
Replace MFPC PWB
- Code: E7-03
- Description: HDD error
- Causes: MFPC PWB and HDD connector, harness connection trouble
HDD trouble
MFPC PWB trouble - Troubleshooting Guides: Check connection state of MFPC PWB and HDD connector, harness
SIM62-2, 62-3 to execute
Replace HDD
Replace MFPC PWB
- Code: E7-04
- Description: HDD-ASIC error
- Causes: HDD-ASIC trouble
- Troubleshooting Guides: Replace MFPC PWB
- Code: E7-10
- Description: Shading error(Black level)
- Causes: CCD unit connector, harness connection trouble
CCD unit trouble
SCN-cnt PWB trouble - Troubleshooting Guides: Check connection state of CCD unit connector, harness
Replace CCD unit
Replace SCN-cnt PWB
– Sharp MXB455WZ printer Error Codes and quick guide on repairing:
- Code: E7-11
- Description: Shading error(White level)
- Causes: CCD unit connector, harness connection trouble
Dirt on mirror, lens and white reference plate
Copy lamp lighting trouble
CCD unit trouble
SCN-cnt PWB trouble - Troubleshooting Guides: Check connection state of CCD unit connector, harness
Check connection state of Copy lamp unit connector, harness
Clean mirror, lens and white reference plate
Replace CCD unit
Replace SCN-cnt PWB
- Code: E7-14
- Description: CCD-ASIC error
- Causes: SCN-cnt PWB trouble
- Troubleshooting Guides: Replace SCN-cnt PWB
- Code: E7-20
- Description: LSU laser detection error
- Causes: Reduced laser power, lighting error, laser diode trouble
LSU connector, harness connection trouble
LSU unit trouble
LSU-cnt PWB trouble - Troubleshooting Guides: SIM61-1 to execute
Check connection state of LSU connector, harness
Replace LSU-cnt PWB
Replace LSU unit
- Code: E7-21
- Description: LSU laser deterioration error
- Causes: Reduced laser power, lighting error, laser diode trouble
LSU connector, harness connection trouble
LSU unit trouble
LSUcnt PWB trouble - Troubleshooting Guides: SIM61-1 to execute
Check connection state of LSU connector, harness
Replace LSUcnt PWB
Replace LSU unit
- Code: E7-28
- Description: Connection error between PCU and LSU
- Causes: Communication error between LSU ASIC and PCU PWB
Connector, harness connection trouble
PCU PWB trouble
LSUcnt PWB trouble - Troubleshooting Guides: Check connection of the connector and the harness between the PCU PWB and the LSUcnt PWB
Replace PCU PWB
Replace LSUcnt PWB
- Code: E7-29
- Description: LSU-ASIC error
- Causes: Oscillation abnormality of the external oscillator used in the LSU ASIC.
LSU ASIC abnormality on the LSUcnt PWB.
Frequency abnormality of picture transfer clock of MFPC PWB.
MFPC PWB trouble - Troubleshooting Guides: Replace LSUcnt PWB
Replace MFPC PWB
Check connection of the connector and the harness between the MFPC PWB and the LSUcnt PWB.
- Code: E7-49
- Description: Water Mark data error
- Causes: Watermark data error HDD trouble
If watermark data is not installed, U2-60 is displayed at startup - Troubleshooting Guides: SIM62-02/SIM62-03 to execute
SIM49-5 to execute
Replace HDD
- Code: E7-50
- Description: PCU PWB and firmware inconsistent error
- Causes: Machine incompatible PWB and firmware
PCU PWB trouble
LSU unit trouble - Troubleshooting Guides: Check firmware version
Replace PCU PWB
Replace LSU unit
- Code: E7-55
- Description: PCU EEPROM sum check error
- Causes: Machine incompatible PWB and firmware PCU PWB trouble
- Troubleshooting Guides: Check firmware version
Replace PCU PWB
- Code: E7-60
- Description: Mismatched Board or Firmware with MFP
- Causes: Machine incompatible PWB and firmware
MFPC PWB trouble - Troubleshooting Guides: Check firmware version
Replace MFPC PWB
- Code: E7-61
- Description: Mismatched MFP and PCU
- Causes: Combination error of MFPC PWB and PCU PWB
MFPC PWB trouble - Troubleshooting Guides: Check combination of MFPC PWB and PCU PWB
Replace MFPC PWB
- Code: E7-62
- Description: MFPC connection error
- Causes: Combination error of MFPC PWB and scanner
MFPC PWB trouble - Troubleshooting Guides: Check combination of MFPC PWB and scanner
- Code: E7-80
- Description: Communication error between MFP and SCU
- Causes: MFPC PWB connector, harness connection trouble
MFPC PWB trouble - Troubleshooting Guides: Check connection state of MFPC PWB connector, harness
Replace MFPC PWB
- Code: E7-90
- Description: Communication error between MFP and PCU
- Causes: MFPC PWB, PCU PWB connector, harness connection trouble
MFPC PWB trouble
PCU PWB trouble - Troubleshooting Guides: Check connection state of SCN MFP PWB, PCU PWB connector, harness
Replace SCN MFP PWB
Replace PCU PWB
- Code: E7-91
- Description: Decode error(FAX received image data)
- Causes: Image compression data corruption
HDD trouble
mSATA eMMC trouble
MFPC PWB trouble
FAX PWB trouble - Troubleshooting Guides: SIM60-1 to execute
Replace HDD
Replace mSATA eMMC
Replace MFPC PWB
Replace FAX PWB
- Code: E7-92
- Description: Decode error(Copy image data)
- Causes: Image compression data corruption
MFPC PWB trouble - Troubleshooting Guides: SIM60-1 to execute
Replace HDD
Replace MFPC PWB
- Code: E7-93
- Description: Decode error(except Copy and Fax)
- Causes: Image compression data corruption
HDD trouble
MFPC PWB trouble - Troubleshooting Guides: SIM60-1 to execute
Replace HDD
Replace MFPC PWB
- Code: E7-94
- Description: Decode error(Filing image data)
- Causes: Image compression data corruption
HDD trouble
MFPC PWB trouble - Troubleshooting Guides: SIM60-1 to execute
Replace HDD
Replace MFPC PWB
- Code: E7-96
- Description: DIMM memory check error(MFPC PWB)
- Causes: Image compression data corruption
HDD trouble
MFPC PWB trouble - Troubleshooting Guides: SIM60-1 to execute
Replace HDD
Replace MFPC PWB
- Code: E7-A8
- Description: mSATA eMMC error
- Causes: mSATA eMMC contact trouble
mSATA eMMC trouble
MFPC PWB trouble - Troubleshooting Guides: Check contact state of mSATA eMMC
Replace mSATA eMMC
Replace MFPC PWB
- Code: E7-C0
- Description: TPM PWB data access error
- Causes: TPM PWB connection trouble
TPM PWB used in other MFP was attached - Troubleshooting Guides: Power OFF/ON to cancel
Check connection state of TPM PWB connector, harness
- Code: E7-C1
- Description: Security check error
- Causes: Program error
TPM PWB trouble - Troubleshooting Guides: Power OFF/ON to cancel
Check connection state of TPM PWB connector, harness
- Code: EE-EC
- Description: Automatic toner density adjustment error(Sampling abnormal)
- Causes: Sensor (TCS) trouble
Charging voltage / developing voltage problem trouble
Developing unit trouble
PCU PWB trouble - Troubleshooting Guides: Replace developing unit
Replace PCU PWB
- Code: EE-EL
- Description: Automatic toner density adjustment error (Over toner)
- Causes: Sensor (TCS) trouble
Charging voltage / developing voltage problem trouble
Developing unit trouble
PCU PWB trouble - Troubleshooting Guides: Replace developing unit
Replace PCU PWB
- Code: EE-EU
- Description: Automatic toner density adjustment error (Under toner)
- Causes: Sensor (TCS) trouble
Charging voltage / developing voltage problem trouble
Developing unit trouble
PCU PWB trouble - Troubleshooting Guides: Replace developing unit
Replace PCU PWB
- Code: F1-00
- Description: Finisher – PCU PWB communication error
- Causes: Connector, harness connection trouble
Finisher control PWB trouble
PCU PWB trouble - Troubleshooting Guides: Power OFF/ON to cancel
Check connection state of connector, harness
Replace finisher control PWB
Replace PCU PWB
- Code: F1-03
- Description: Finisher paper delivery roller lift operation trouble (FSWM)
- Causes: Connector, harness connection trouble
Sensor trouble
Motor trouble
Finisher control PWB trouble - Troubleshooting Guides: SIM3-3 to execute
Check connection state of connector, harness
Replace sensor
Replace motor
Replace finisher control PWB
- Code: F1-10
- Description: Finisher staple motor trouble (STPMOV_M)
- Causes: Connector, harness connection trouble
Sensor (FSHPS) trouble
Motor (FSM) trouble
Finisher control PWB trouble - Troubleshooting Guides: SIM3-3 to execute
Check connection state of connector, harness
Replace sensor (FSHPS)
Replace motor (FSM)
Replace finisher control PWB
- Code: F1-15
- Description: Finisher paper exit tray lift operation trouble (TRYLFT_M)
- Causes: Connector, harness connection trouble
Sensor trouble
Motor (FLM / FTLM) trouble
Finisher control PWB trouble - Troubleshooting Guides: SIM3-3 to execute
Check connection state of connector, harness
Replace sensor
Replace motor (FLM / FTLM)
Replace finisher control PWB
- Code: F1-19
- Description: Finisher paper alignment operation trouble F
- Causes: Connector, harness connection trouble
Sensor trouble
Motor (FPAM-F) trouble
Finisher control PWB trouble - Troubleshooting Guides: SIM3-3 to execute
Check connection state of connector, harness
Replace sensor
Replace motor (FPAM-F)
Replace finisher control PWB
- Code: F1-20
- Description: Finisher paper alignment operation trouble R
- Causes: Connector, harness connection trouble
Sensor trouble
Motor (FPAM-R) trouble
Finisher control PWB trouble - Troubleshooting Guides: SIM3-3 to execute
Check connection state of connector, harness
Replace sensor
Replace motor (FPAM-R)
Replace finisher control PWB
- Code: F1-21
- Description: Finisher fan trouble
- Causes: Finisher fan motor trouble
Finisher control PWB trouble
Harness and connector connection trouble - Troubleshooting Guides: SIM3-3 to check the operation of the fan motor
Check connection between the finisher control PWB and the fan
Replace the finisher fan
Replace the finisher control PWB
- Code: F1-29
- Description: Finisher Board Cooling Fan trouble
- Causes: Finisher board cooling fan lock
Finisher control PWB trouble
Connection trouble of the connector and the harness - Troubleshooting Guides: SIM3-3 to check the operation of the control board cooling fan (FBCF)
Replace the finisher board cooling fan
Replace the finisher control PWB
Connection trouble of the connector and the harness
- Code: F1-37
- Description: Finisher data backup RAM error
- Causes: Finisher control PWB trouble
Malfunction due to noises - Troubleshooting Guides: Replace the finisher control PWB
- Code: F1-50
- Description: Combination error Finisher and Main body
- Causes: Improper combination between main machine and finisher
Finisher control PWB trouble - Troubleshooting Guides: Install finisher which is proper for main machine
Replace finisher control PWB
- Code: F1-55
- Description: Finisher unit ROM error
- Causes: Finisher firmware inconsistency
- Troubleshooting Guides: SIM49-1 to execute
- Code: F2-22
- Description: Discharge lamp trouble
- Causes: Connector, harness connection trouble
Discharge lamp trouble
PCU PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace discharge lamp
Replace PCU PWB
- Code: F2-39
- Description: Temperature and humidity sensor trouble (temperature)
- Causes: Connector, harness connection trouble
Sensor (TH/HUD) trouble
PCU PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace sensor (TH/HUD)
Replace PCU PWB
- Code: F2-40
- Description: Toner concentration sensor trouble
- Causes: Connector, harness connection trouble
DV unit trouble
Sensor (TCS) trouble
PCU PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace DV unit
Replace PCU PWB
- Code: F2-58
- Description: Temperature and humidity sensor trouble (humidity)
- Causes: Connector, harness connection trouble
Sensor (TH/HUD) trouble
PCU PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace sensor (TH/HUD)
Replace PCU PWB
- Code: F2-64
- Description: Black toner supply trouble
- Causes: Connector, harness connection trouble
DV unit trouble
Toner cartridge trouble
Toner transport pipe section trouble
Sensor (TCS) trouble
Motor (TNM) trouble
PCU PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace DV unit
Replace toner cartridge
Check transport pipe section
Replace motor (TNM)
Replace PCU PWB
- Code: F2-70
- Description: Mismatched black toner cartridge
- Causes: Improper toner cartridge is inserted
Toner cartridge trouble
PCU PWB trouble - Troubleshooting Guides: Replace toner cartridge
Replace PCU PWB
- Code: F2-74
- Description: Black CRUM error
- Causes: Connector, harness connection trouble
Toner cartridge trouble
PCU PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace toner cartridge
Replace PCU PWB
- Code: F2-78
- Description: Image density sensor error
- Causes: Connector, harness connection trouble
Sensor (PCS) dirt or trouble
PCU PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Clean sensor (PCS) or replace
Replace PCU PWB
- Code: F6-00
- Description: Communication error(MFP-FAX)
- Causes: Connector, harness connection trouble FAX PWB trouble
- Troubleshooting Guides: Check connection state of connector, harness
Replace FAX PWB
- Code: F6-01
- Description: FAX EEPROM error
- Causes: FAX EEPROM trouble
FAX EEPROM access trouble - Troubleshooting Guides: SIM66-3 to execute
Replace FAX EEPROM
Replace FAX PWB
- Code: F6-02
- Description: FAX PWB power supply trouble
- Causes: Connector, harness connection trouble
DC PWB trouble
MFPC PWB trouble
FAX PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace DC PWB
Replace MFPC PWB
Replace FAX PWB
- Code: F6-04
- Description: FAX modem error
- Causes: FAX modem chip operation trouble
- Troubleshooting Guides: Replace FAX PWB
- Code: F6-21
- Description: Combination error(LIU-FAX soft SW setting)
- Causes: Improper destination of LIU PWB
LIU PWB trouble - Troubleshooting Guides: Check proper destination of LIU PWB
Replace LIU PWB
- Code: F6-30
- Description: FAX power controller access error
- Causes: Improper destination of TEL/LIU PWB
TEL/LIU PWB trouble - Troubleshooting Guides: Check proper destination of TEL/LIU PWB
Replace TEL/LIU PWB
- Code: F6-97
- Description: Combination error(FAX PWB-Main body)
- Causes: Improper FAX PWB
FAX PWB trouble - Troubleshooting Guides: Replace FAX PWB
- Code: F6-98
- Description: Combination error(FAX-Main body destination)
- Causes: Main machine and FAX destination inconsistency
- Troubleshooting Guides: SIM26-6 to execute
Check FAX destination
- Code: H2-00
- Description: Thermistor open trouble (TH_UM_AD2)
- Causes: Thermistor connector, harness connection trouble
Fusing section connector connection trouble
Thermistor trouble
PCU PWB trouble
AC PWB trouble
Fusing unit not installed - Troubleshooting Guides: SIM44-14 to execute
Check connection state of thermistor connector, harness
Check connection state of fusing section connector
Replace thermistor
Replace PCU PWB
Replace AC PWB trouble
Check fusing unit installed
- Code: H2-02
- Description: Thermistor open trouble (TH_US)
- Causes: Thermistor connector, harness connection trouble
Fusing section connector connection trouble
Thermistor trouble
PCU PWB trouble
AC PWB trouble
Fusing unit not installed - Troubleshooting Guides: SIM44-14 to execute
Check connection state of thermistor connector, harness
Check connection state of fusing section connector
Replace thermistor
Replace PCU PWB
Replace AC PWB trouble
Check fusing unit installed
- Code: H2-03
- Description: Thermistor open trouble (TH_UM_AD1)
- Causes: Thermistor connector, harness connection trouble
Fusing section connector connection trouble
Thermistor trouble
PCU PWB trouble
Fusing unit not installed
Fusing unit trouble - Troubleshooting Guides: SIM44-14 to execute
Check connection state of thermistor connector, harness
Check connection state of fusing section connector
Replace thermistor
Replace PCU PWB
Check fusing unit installed
Replace fusing unit
- Code: H2-06
- Description: Thermistor open trouble (TH_US2)
- Causes: Thermistor connector, harness connection trouble
Fusing section connector connection trouble
Thermistor trouble
PCU PWB trouble
AC PWB trouble
Fusing unit not installed - Troubleshooting Guides: SIM44-14 to execute
Check connection state of thermistor connector, harness
Check connection state of fusing section connector
Replace thermistor
Replace PCU PWB
Replace AC PWB trouble
Check fusing unit installed
- Code: H3-00
- Description: Fuser high temperature trouble (TH_UM)
- Causes: Thermistor connector, harness connection trouble
Thermistor trouble
PCU PWB trouble
AC PWB trouble - Troubleshooting Guides: SIM44-14 to execute
SIM5-2 to execute
Check connection state of thermistor connector, harness
Replace thermistor
Replace PCU PWB
Replace AC PWB
SIM14 to cancel
- Code: H3-02
- Description: Fuser high temperature trouble (TH_US)
- Causes: Thermistor connector, harness connection trouble
Thermistor trouble
PCU PWB trouble
AC PWB trouble - Troubleshooting Guides: SIM44-14 to execute
SIM5-2 to execute
Check connection state of thermistor connector, harness
Replace thermistor
Replace PCU PWB
Replace AC PWB
SIM14 to cancel
- Code: H4-00
- Description: Fuser low temperature trouble (TH_UM)
- Causes: Thermistor connector, harness connection trouble
Thermistor trouble
Heater lamp trouble
PCU PWB trouble
Thermostat trouble
AC PWB trouble - Troubleshooting Guides: SIM44-14 to execute
SIM5-2 to execute
Check connection state of thermistor connector, harness
Replace thermistor
Replace heater lamp
Replace PCU PWB
Replace thermostat
Replace AC PWB
SIM14 to cancel
- Code: H4-02
- Description: Fuser low temperature trouble (TH_US)
- Causes: Thermistor connector, harness connection trouble
Thermistor trouble
Heater lamp trouble
PCU PWB trouble
Thermostat trouble
AC PWB trouble - Troubleshooting Guides: SIM44-14 to execute
SIM5-2 to execute
Check connection state of thermistor connector, harness
Replace thermistor
Replace heater lamp
Replace PCU PWB
Replace thermostat
Replace AC PWB
SIM14 to cancel
- Code: H4-30
- Description: Fuser differential input trouble (TH_UM)
- Causes: Thermistor connector, harness connection trouble
Thermistor trouble
Heater lamp trouble
PCU PWB trouble - Troubleshooting Guides: SIM5-2 to execute
Check connection state of thermistor connector, harness
Replace thermistor
Replace heater lamp
Replace PCU PWB
SIM14 to cancel
- Code: H5-01
- Description: 5 times continuous POD1 not reach jam
- Causes: Fusing jam was not cancel completely (jam paper remains)
Fusing unit installation trouble
Fusing unit, drive section trouble
Sensor (POD1) connector, harness connection trouble
Sensor (POD1) trouble
PCU PWB trouble - Troubleshooting Guides: Check fusing unit installed
Check fusing drive section
Check connection state of sensor (POD1) connector,
harness
Replace sensor (POD1)
Replace PCU PWB
Replace fusing unit
SIM14 to cancel
- Code: H7-10
- Description: Recovery error from fuser low temperature (TH_UM)
- Causes: Thermistor connector, harness connection trouble
Thermistor trouble
Heater lamp trouble
PCU PWB trouble
Thermostat trouble
AC PWB trouble - Troubleshooting Guides: SIM5-2 to execute
Check connection state of thermistor connector, harness
Replace thermistor
Replace heater lamp
Replace PCU PWB
Replace thermostat
Replace AC PWB
- Code: H7-12
- Description: Recovery error from fuser low temperature (TH_US)
- Causes: Thermistor connector, harness connection trouble
Thermistor trouble
Heater lamp trouble
PCU PWB trouble
Thermostat trouble
AC PWB trouble - Troubleshooting Guides: SIM5-2 to execute
Check connection state of thermistor connector, harness
Replace thermistor
Replace heater lamp
Replace PCU PWB
Replace thermostat
Replace AC PWB
- Code: L1-00
- Description: Scanner feed trouble
- Causes: Connector, harness connection trouble
Scanner unit trouble
Sensor (MHPS) trouble
Motor (MIM) trouble
SCN-cnt PWB trouble - Troubleshooting Guides: SIM1-1 to execute
Check connection state of connector, harness
Replace scanner unit
Replace sensor (MHPS)
Replace motor (MIM)
Replace SCN-cnt PWB
- Code: L3-00
- Description: Scanner return trouble
- Causes: Connector, harness connection trouble
Scanner unit trouble
Sensor (MHPS) trouble
Motor (MIM) trouble
SCN-cnt PWB trouble - Troubleshooting Guides: SIM1-1 to execute
Check connection state of connector, harness
Replace scanner unit
Replace sensor (MHPS)
Replace motor (MIM)
Replace SCN-cnt PWB
- Code: L4-01
- Description: Main motor lock trouble
- Causes: Connector, harness connection trouble
Motor trouble(MM)
PCU PWB trouble - Troubleshooting Guides: SIM6-1 to execute
Check connection state of connector, harness
Replace motor (MM)
Replace PCU PWB
- Code: L4-14
- Description: Toner cartridge motor lock trouble
- Causes: Motor trouble(TNM)
Toner motor drive detect sensor trouble (TM_COUNT)
Connector, harness connection trouble
PCU PWB trouble - Troubleshooting Guides: SIM10-1 to execute
SIM10-4 to execute
Check connection state of connector, harness
Replace motor (TNM)
Replace toner motor drive detect sensor
Replace PCU PWB
Replace detect sensor
- Code: L4-17
- Description: Drum motor lock trouble
- Causes: Motor trouble(DM)
Connector, harness connection trouble
PCU PWB trouble - Troubleshooting Guides: SIM25-1 to execute
Check connection state of connector, harness
Replace motor (DM)
Replace PCU PWB
- Code: L4-31
- Description: Paper delivery cooling fan trouble
- Causes: Motor trouble(POFM)
Connector, harness connection trouble
PCU PWB trouble - Troubleshooting Guides: SIM6-2 to execute
Check connection state of connector, harness
Replace fan (POFM)
Replace PCU PWB
- Code: L4-32
- Description: Power supply unit fan trouble
- Causes: Motor trouble(PSFM)
Connector, harness connection trouble
PCU PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace fan (PSFM)
Replace PCU PWB
- Code: L4-35
- Description: Fuser cooling fan trouble
- Causes: Motor trouble(FUFM)
Connector, harness connection trouble
PCU PWB trouble - Troubleshooting Guides: SIM6-2 to execute
Check connection state of connector, harness
Replace fan (FUFM)
Replace PCU PWB
- Code: L4-39
- Description: Machine cooling fan trouble
- Causes: Motor trouble(VFM)
Connector, harness connection trouble
PCU PWB trouble - Troubleshooting Guides: SIM6-2 to execute
Check connection state of connector, harness
Replace motor (VFM)
Replace PCU PWB
- Code: L4-43
- Description: Paper cooling fan trouble
- Causes: Motor trouble(POFM2)
Connector, harness connection trouble
PCU PWB trouble - Troubleshooting Guides: SIM6-2 to execute
Check connection state of connector, harness
Replace motor (POFM2)
Replace PCU PWB
- Code: L6-10
- Description: Polygon motor trouble
- Causes: Connector, harness connection trouble
Motor (PGM) trouble
LSU PWB trouble - Troubleshooting Guides: SIM6-1 to execute
Check connection state of connector, harness
Replace LSU PWB
Replace LSU unit
- Code: L8-01
- Description: Full wave signal detection error
- Causes: Connector, harness connection trouble
Power supply unit trouble
PCU PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace power supply unit
Replace PCU PWB
- Code: L8-02
- Description: Abnormal full wave signal error
- Causes: Connector, harness connection trouble
Power supply unit trouble
PCU PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace power supply unit
Replace PCU PWB
- Code: L8-20
- Description: Communication error of MFP/Mother board
- Causes: MFPC PWB trouble
SCN-cnt PWB trouble - Troubleshooting Guides: Check main body ground
Replace MFPC PWB
Replace SCN-cnt PWB
- Code: U1-01
- Description: Battery trouble
- Causes: Battery life
Battery circuit trouble - Troubleshooting Guides: Check battery voltage is 2.5V or above
Replace battery
- Code: U2-00
- Description: MFP EEPROM read/write error
- Causes: EEPROM trouble
EEPROM socket contact trouble
Strong external noises - Troubleshooting Guides: Check power environment
Replace EEPROM
Replace MFPC PWB
- Code: U2-05
- Description: Account data error(HDD-MFP SRAM)
- Causes: Authentication table error If frequent occurrence of this error is found, the following devices may possibly be damaged
HDD/mSATA eMMC trouble
MFPC PWB trouble - Troubleshooting Guides: Replace HDD/mSATA eMMC
Replace MFPC PWB
- Code: U2-11
- Description: MFP EEPROM counter check sum error
- Causes: EEPROM trouble
EEPROM socket contact trouble
Strong external noises - Troubleshooting Guides: Replace MFPC PWB
SIM16 to cancel
- Code: U2-30
- Description: MFP and PCU manufacturing No. data inconsistency
- Causes: When replacing MFPC PWB or PCU PWB, EEPROM which was mounted on PWB before replacement is not mounted on new PWB
Replace MFPC PWB
Replace PCU PWB - Troubleshooting Guides: Check EEPROM is properly set
Replace MFPC PWB
Replace PCU PWB
- Code: U2-40
- Description: mSATA eMMC system storage data area error
- Causes: mSATA eMMC system storage data area error
- Troubleshooting Guides: Power OFF/ON and backup data is written into mSATA eMMC and machine is automatically booted
Leave trouble occurrence in trouble history
- Code: U2-41
- Description: HDD storage data area error
- Causes: File error occurs saved data area, disabling backup of saved file of machine adjustment value in HDD
- Troubleshooting Guides: Power OFF/ON to cancel
Replace HDD
SIM62 to execute HDD format
SIM16 to cancel
- Code: U2-42
- Description: Machine adjustment data error
- Causes: Saved file of machine adjustment value in mSATA eMMC and system saved data in HDD error
- Troubleshooting Guides: Perform backup of mSATA eMMC and HDD
Replace HDD
SIM62 to execute HDD format
Ajust machine again and set adjustment values
- Code: U2-50
- Description: HDD user authentication data check sum error
- Causes: HDD trouble
MFPC PWB trouble
Strong external noises - Troubleshooting Guides: Check data related to check sum error (address book, image send system registration data) and register again
Replace HDD
Replace MFPC PWB
SIM16 to cancel
- Code: U2-60
- Description: Water Mark check error
- Causes: Watermark data trouble
MFPC PWB trouble - Troubleshooting Guides: SIM49-5 to execute
Replace MFPC PWB
- Code: U2-70
- Description: OCR dictionary check error
- Causes: OCR dictionary data trouble
- Troubleshooting Guides: SIM49-6 to execute
- Code: U2-80
- Description: SCU EEPROM read write error
- Causes: EEPROM socket contact trouble
EEPROM trouble
SCN-cnt PWB trouble - Troubleshooting Guides: Check contact of EEPROM socket
Replace EEPROM
Replace SCN-cnt PWB
SIM16 to cancel
- Code: U2-81
- Description: SCU EEPROM check sum error
- Causes: EEPROM socket contact trouble
EEPROM trouble
SCN-cnt PWB trouble - Troubleshooting Guides: Check contact of EEPROM socket
Replace EEPROM
Replace SCN-cnt PWB
SIM16 to cancel
- Code: U2-90
- Description: PCU EEPROM read write error
- Causes: EEPROM socket contact trouble
EEPROM trouble
PCU PWB trouble - Troubleshooting Guides: Check contact of EEPROM socket
Check SIM adjustment values of engine and adjust again if they are improper
Replace EEPROM
Replace PCU PWB
SIM16 to cancel
- Code: U2-91
- Description: PCU EEPROM check sum error
- Causes: EEPROM socket contact trouble
Replace EEPROM
Replace PCU PWB - Troubleshooting Guides: Check contact of EEPROM socket
Replace EEPROM
Replace PCU PWB
SIM16 to cancel
- Code: U5-00
- Description: Communication error between SPF and SCN-cnt PWB
- Causes: Malfunction due to noises
Connector, harness connection trouble
SCN-cnt PWB trouble
DSPF PWB trouble - Troubleshooting Guides: Power OFF/ON to cancel
Check connection state of connector, harness
Replace SCN-cnt PWB
Replace DSPF PWB
- Code: U5-20
- Description: SPF paper feed motor transport trouble
- Causes: Connector, harness connection trouble
Motor (SPFM) trouble - Troubleshooting Guides: SIM2-3 to execute
Check connection state of connector, harness
Replace motor (SPFM)
- Code: U6-00
- Description: PCU PWB – Paper feed desk (paper feed tray3, 4) communication error
- Causes: Malfunction due to noises
Connector, harness connection trouble
Desk control PWB trouble
PCU PWB trouble - Troubleshooting Guides: Power OFF/ON to cancel
Check connection state of connector, harness
Replace desk control PWB
Replace PCU PWB
- Code: U6-01
- Description: Desk paper feed tray 1 lift trouble
- Causes: Connector, harness connection trouble
Sensor (D1LUD) trouble
Desk tray1 control PWB trouble
Lift unit trouble
PCU PWB trouble - Troubleshooting Guides: SIM4-2 to execute
Check connection state of connector, harness
Replace sensor (D1LUD)
Replace desk tray1 control PWB
Replace lift unit
Replace PCU PWB
- Code: U6-02
- Description: Desk paper feed tray 2 lift trouble
- Causes: Connector, harness connection trouble
Sensor (D2LUD) trouble
Desk tray2 control PWB trouble
Lift unit trouble
PCU PWB trouble - Troubleshooting Guides: SIM4-2 to execute
Check connection state of connector, harness
Replace sensor (D2LUD)
Replace desk tray2 control PWB
Replace lift unit
Replace PCU PWB
- Code: U6-03
- Description: Desk paper feed tray 3 lift trouble
- Causes: Connector, harness connection trouble
Sensor (D3LUD) trouble
Desk tray3 control PWB trouble
Lift unit trouble
PCU PWB trouble - Troubleshooting Guides: SIM4-2 to execute
Check connection state of connector, harness
Replace sensor (D3LUD)
Replace desk tray3 control PWB
Replace lift unit
Replace PCU PWB
- Code: U6-11
- Description: Desk paper feed tray 1 transport trouble
- Causes: Connector, harness connection trouble
Motor (D1PFM) trouble
Desk tray1 control PWB trouble
PCU PWB trouble - Troubleshooting Guides: SIM4-3 to execute
Check connection state of connector, harness
Replace motor (D1PFM)
Replace desk tray1 control PWB
Replace PCU PWB
- Code: U6-12
- Description: Desk paper feed tray 2 transport trouble
- Causes: Connector, harness connection trouble
Motor (D2PFM) trouble
Desk tray2 control PWB trouble
PCU PWB trouble - Troubleshooting Guides: SIM4-3 to execute
Check connection state of connector, harness
Replace motor (D2PFM)
Replace desk tray2 control PWB
Replace PCU PWB
- Code: U6-13
- Description: Desk paper feed tray 3 transport trouble
- Causes: Connector, harness connection trouble
Motor (D3PFM) trouble
Desk tray3 control PWB trouble
PCU PWB trouble - Troubleshooting Guides: SIM4-3 to execute
Check connection state of connector, harness
Replace motor (D3PFM)
Replace desk tray3 control PWB
Replace PCU PWB
- Code: U6-30
- Description: Desk communication error between paper feed tray 1 and tray 2
- Causes: Desk paper feed tray 1 and 2 connector, harness connection trouble
Desk tray1 control PWB trouble
Desk tray2 control PWB trouble
Malfunction due to noise - Troubleshooting Guides: Power OFF/ON to cancel
Check connection state of connector, harness
Replace desk tray1 control PWB
Replace desk tray2 control PWB
- Code: U6-40
- Description: Desk communication error between paper feed tray 2 and tray
- Causes: Desk paper feed tray 2 and 3 connector, harness connection trouble
Desk tray2 control PWB trouble
Desk tray3 control PWB trouble
Malfunction due to noise - Troubleshooting Guides: Power OFF/ON to cancel
Check connection state of connector, harness
Replace desk tray2 control PWB
Replace desk tray3 control PWB
- Code: U6-50
- Description: Desk – Main unit combination trouble
- Causes: Improper combination between main machine and desk
Desk control PWB trouble - Troubleshooting Guides: Install desk which is proper for main machine
Replace desk control PWB
- Code: U6-55
- Description: Desk firmware inconsistent error
- Causes: Firmware version is inconsistency
- Troubleshooting Guides: SIM49-1 to execute
- Code: U6-56
- Description: Desk paper feed tray 1 firmware error
- Causes: Firmware version is inconsistency
- Troubleshooting Guides: SIM49-1 to execute
- Code: U6-57
- Description: Desk paper feed tray 2 firmware error
- Causes: Firmware version is inconsistency
- Troubleshooting Guides: SIM49-1 to execute
- Code: U6-58
- Description: Desk paper feed tray 3 firmware error
- Causes: Firmware version is inconsistency
- Troubleshooting Guides: SIM49-1 to execute
- Code: U7-50
- Description: Communication error of Vendor machine / MFP
- Causes: Strong external noises
Improper setting of vendor machine specifications
Vendor machine trouble
Connector, harness connection trouble
MFPC PWB trouble - Troubleshooting Guides: Power OFF/ON to cancel
Change specification of vendor machine
Check connection state of connector, harness
Replace MFPC PWB
- Code: U7-51
- Description: Vendor machine error
- Causes: Vendor machine trouble
Connector, harness connection trouble - Troubleshooting Guides: Repair vendor machine referring to detailed error code
Check connection state of connector, harness
- Code: U9-01
- Description: Touch panel trouble
- Causes: Connector, harness connection trouble
Touch panel trouble
MFPC PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace touch panel
Replace MFPC PWB
- Code: UC-02
- Description: SCAN ASIC IPD error
- Causes: SCN-cnt PWB trouble
- Troubleshooting Guides: Replace SCN-cnt PWB
- Code: UC-12
- Description: SCAN ASIC IPD error (DSPF detection)
- Causes: DSPF PWB trouble
- Troubleshooting Guides: Replace DSPF PWB
- Code: UC-20
- Description: SCAN ASIC DOCC error
- Causes: SCN-cnt PWB trouble
- Troubleshooting Guides: Replace SCN-cnt PWB
- Code: UC-30
- Description: SCAN ASIC DOCC error (DSPF detection)
- Causes: DSPF PWB trouble
- Troubleshooting Guides: Replace DSPF PWB
Epson XP-220 Adjustment Program
– OS Support: only Windows Operating System.
– Because Adjprog.exe gets Hardware ID info => Antivirus will misunderstand Adjprog.exe is the virus ==> you need to disable antivirus before extract and run Epson XP-220 Adjustment Program or add to exclusion folder
– Limitation: Unlimited using on only 1 Computer.
– Epson XP-220 AdjProg or Epson XP-220 Adjustment Program or Epson XP-220 Adj Program, is a middleware developed by third-party software to supply for Epson XP-220 printer, making printer continuous printing without error.
– Epson XP-220 Adjustment Program is featured with clearing the waste ink counter, ultra-deep clean to clean the printhead, adjust the smoothness of the printhead, adjust the motor headers, and fix the errors: no printing, lack of colour printing, colour blur, prints with horizontal and vertical stripes…
Epson XP-220 Adjustment Functions:
– Bi-D Adjustment
– USB ID Input
– Initial Ink Charge
– Deep Cleaning the Print Head
– Reset Waste Ink Pad Counter
– Head ID Setting
– EEPROM initial setting
– Top margin Adjustment
Using Epson XP-220 Adjustment Program
– Choose printer model and usb connection
– Choose Particular Adjustment Mode
– Choose Waste Ink Pad Counter
– Read Waste Ink Pad Counter
– Reset Waste Ink Pad Counter
Active Epson XP-220 Adjustment Program
– Run Adjprog.exe, Copy XP-220 Hardware ID, send it to admin email : [email protected] to get serial key and then active Epson XP-220 Adjustment Program.
– More information about Epson XP-220 Adjustment Program: https://shop.nguyendangnam.com/product/epson-xp-220-adjustment-program/
– Download Canon driver and firmware in specific model: https://dnasofts.com/canon-mf264dw-printer-driver-firmware-and-user-manual-free-download/
– Download Epson driver and firmware in specific model: https://dnasofts.com/download-epson-sp-gs6000-driver-firmware-and-manuals/
Source:
https://chiplessprinter.com
https://dnasofts.com
https://shop.nguyendangnam.com/
https://nguyendangnam.me/
https://chiplessprinter.com/reset-epson-waste-ink-pad-counter.html
Contact us to get support with Sharp MXB455WZ Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/