Sharp DXC200P Printer with list Error Codes and Epson L8160 Adjustment Program
– Printer model: Sharp DXC200P
– Error codes on Sharp DXC200P with details instruction fixing:
- Code: 195
- Description: Serial Number Error
- Causes: The serial number stored in the memory (EGB) is not correct.
- Troubleshooting Guides: EEPROM defective EGB replaced without original EEPROM
- Code: 202
- Description: Polygon motor error 1: ON timeout
- Causes: The polygon mirror motor does not reach the targeted operating speed within 5 sec. after turning on or changing speed.
- Troubleshooting Guides:
- Code: 203
- Description: Polygon motor error 2: OFF timeout
- Causes: The polygon mirror motor does not leave the READY status within 3 sec. after the polygon motor switched off.
- Troubleshooting Guides:
- Code: 204
- Description: Polygon motor error 3: XSCRDY signal error
- Causes: The SCRDY_N signal remains HIGH for 200 ms while the LD unit is firing.
- Troubleshooting Guides: • Polygon motor/driver board harness loose or disconnected • Polygon motor/driver board defective • Laser optics unit defective • IPU (EGB) defective 1. Replace the interface harness of the laser optics unit. 2. Replace the laser optics unit. 3. Replace the EGB (Engine Board).
- Code: 220
- Description: Laser Synchronizing Detection Error: [K]/[Y]
- Causes: The laser synchronizing detection signal for LDB [K]/[Y] is not output after the LDB unit has turned on while the polygon motor is rotating normally.
- Troubleshooting Guides:
- Code: 222
- Description: Laser Synchronizing Detection Error: [M]/[C]
- Causes: The laser synchronizing detection signal for LDB [M]/[C] is not output after the LDB unit has turned on while the polygon motor is rotating normally.
- Troubleshooting Guides: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LDB • Defective EGB 1. Check the connectors. 2. Replace the laser optics unit. 3. Replace the EGB. ·
- Code: 240
- Description: LD error
- Causes: The IPU (EGB) detects a problem at the LD unit.
- Troubleshooting Guides: • Worn-out LD • Disconnected or broken harness of the LD. 1. Replace the laser optics unit.
- Code: 300
- Description: High voltage power output error
- Causes: The measured voltage is not correct when the EGB measures each charge output (charge, development, image transfer belt unit, and transfer unit).
- Troubleshooting Guides: • Disconnected or defective high voltage harness • Defective high voltage power supply • Defective EGB 1. Check or replace the harnesses. 2. Replace the high voltage power supply board 3. Replace the EGB.
- Code: 396
- Description: Black drum motor error
- Causes: The LOCK signal error is detected when the EGB monitors the black drum motor state. (This monitoring is done immediately after power-on, when the motor starts rotating, and immediately after the motor stops.)
- Troubleshooting Guides: • Disconnected or defective motor harness. • Motor slips due to excessive load 1. Check the harness from the black drum motor. Replace it if necessary.e hig
- Code: 397
- Description: Color drum motor error
- Causes: The LOCK signal error is detected when the EGB monitors the color drum motor state. (This monitoring is done immediately after power-on, when the motor starts rotating, and immediately after the motor stops.)
- Troubleshooting Guides: • Disconnected or defective motor harness. • Motor slips due to excessive load 1. Check the harness from the color drum motor. Replace it if necessary.
- Code: 400
- Description: TM sensor error
- Causes: The CPU detected a low voltage of the positive reflection output under the threshold in the TM sensor.
- Troubleshooting Guides: • TM sensors are dirty. • A solid print out due to an electrostatic charging error • The TM sensor is defective. 1. Clean the TM sensors. 2. Replace the TM sensors. 3. Check the image transfer unit. 4. Turn the power Off and On.
- Code: 445
- Description: ITB (Image Transfer Belt) Unit: Home Position Error
- Causes: The ITB contact sensor does not detect the home position of the ITB for 5 seconds after the ITB unit initialization has been done. ITB (Image Transfer Belt) Unit: Contact Position Error The ITB contact sensor does not detect the contact position of the ITB for 5 seconds after the ITB unit has moved to the contact position. ITB (Image Transfer Belt) Unit: No-contact Position Error The ITB contact sensor does not detect the home position of the ITB for 5 seconds after the ITB unit has moved to no-contact position.
- Troubleshooting Guides: • Defective ITB contact motor • Defective ITB contact sensor • Defective ITB unit 1. Replace the ITB contact motor. 2. Replace the ITB contact sensor. 3. Replace the ITB unit.
- Code: 480
- Description: Agitator Motor Error
- Causes: The agitator motor error is detected twice for 10 msec during the initialization at power-on or after the cover is closed.
- Troubleshooting Guides: • Disconnected or defective harness • Defective agitator motor 1. Check or replace the harness. 2. Replace the agitator motor.
- Code: 490
- Description: ITB (Image Transfer Belt) Unit Set Error
- Causes: The TM sensor does not detect the reflection from the ITB.
- Troubleshooting Guides: • No ITB unit in the machine • Dirty TM sensor 1. Check the installation of the ITB unit. 2. Clean the TM sensor.S
- Code: 500
- Description: Transport/Fusing Motor Error
- Causes: The LOCK signal error is detected when the EGB monitors the transport/fusing motor state. (This monitoring is done immediately after power-on, when the motor starts rotating, and immediately after the motor stops.)
- Troubleshooting Guides: • Disconnected or defective motor harness. • Motor slips due to excessive load 1. Check the harness from the transport/fusing motor. Replace it if necessary.
- Code: 530
- Description: LSU Fan Motor Error
- Causes: A LOCK signal is not detected for more than ten seconds while the motor START signal is on and if this error occurs twice consecutively, this SC is issued.
- Troubleshooting Guides: • Disconnected or defective motor harness. • Defective LSU fan motor 1. Check or replace the motor harness. 2. Replace the LSU fan motor.
- Code: 531
- Description: Fusing Fan Motor Error
- Causes: A LOCK signal is not detected for more than ten seconds while the motor START signal is on and if this error occurs twice consecutively, this SC is issued.
- Troubleshooting Guides: • Disconnected or defective motor harness. • Defective LSU fan motor 1. Check or replace the motor harness. 2. Replace the fusing fan motor.
- Code: 541
- Description: Thermistor Error
- Causes: The thermistor output is less than 0°C for 7 seconds.
- Troubleshooting Guides: • Disconnected thermistor • Defective harness connection 1. Check the harness connection of the thermistor. 2. Replace the fusing unit. • Execute ‘Engine Maintenance Menu’ to recover the machine after completing the recovery procedure. Otherwise, the machine continues to issue this SC code and cannot be operated.
– Sharp DXC200P printer Error Codes and quick guide on repairing:
- Code: 542
- Description: Print Ready Temperature Error
- Causes: • The heating roller temperature increase during a set time is not correct. • The fusing temperature does not reach the print ready temperature within a set time after the fusing lamp has turned on.
- Troubleshooting Guides: • Defective thermistor • Incorrect power supply input at the main power socket • Defective fusing lamp 1. Check the voltage of the wall outlet. 2. Replace the fusing unit 3. Replace the fusing lamp. • Execute ‘Engine Maintenance Menu’ to recover the machine after completing the recovery procedure. Otherwise, the machine continues to issue this SC code and cannot be operated.
- Code: 543
- Description: High Temperature Detection Error
- Causes: This SC is issued if one of following conditions occurs: • The thermistor (center) detects 255?XC or thermistor (end) detects 245?XC. • The thermistor (center) detects a 3?XC increment or more for five seconds at 220?XC or more or the thermistor (end) detects a 4?XC increment or more for five seconds at 210?XC or more.ne
- Troubleshooting Guides: • Defective I/O control (EGB) • Defective EGB 1. Replace the EGB • Execute ‘Engine Maintenance Menu’ to recover the machine after completing the recovery procedure. Otherwise, the machine continues to issue this SC code and cannot be operated.
- Code: 545
- Description: Heating Lamp Full-Power Error
- Causes: The fusing lamp is fully-powered for a certain time while the fusing unit stays in the stand-by mode and is not rotating.
- Troubleshooting Guides: • Deformed thermistor • Thermistor not in the correct position • Defective fusing lamp 1. Replace the fusing unit. 2. Replace the fusing lamp. • Execute ‘Engine Maintenance Menu’ to recover the machine after completing the recovery procedure. Otherwise, the machine continues to issue this SC code and cannot be operated.
- Code: 547
- Description: Zero Cross Error
- Causes: The zero cross signal is not detected for three seconds even though the fusing lamp relay is on after turning on the main power or closing the front door.
- Troubleshooting Guides: • Defective fusing lamp relay 1. Turn the main power switch off and on. • Execute ‘Engine Maintenance Menu’ to recover the machine after completing the recovery procedure. Otherwise, the machine continues to issue this SC code and cannot be operated. The power should be turned off and on after the recovery procedure.
- Code: 548
- Description: Low Temperature Error
- Causes: The center thermistor detects 100°C or less for 4 seconds.
- Troubleshooting Guides: • Defective fusing lamp • Defective thermistor 1. Replace the fusing unit. 2. Replace the fusing lamp. • Execute ‘Engine Maintenance Menu’ to recover the machine after completing the recovery procedure. Otherwise, the machine continues to issue this SC code and cannot be operated.d
- Code: 557
- Description: Zero Cross Frequency Error
- Causes: The detection error occurs ten times consecutively in ten zero cross signal detections. This error is defined when the detected zero cross signal is 17 or less/27 or more for 0.2 seconds.
- Troubleshooting Guides: • Defective fusing lamp relay • Unstable input power source 1. Check the power supply source. 2. Replace the fusing unit. 3. Turn the main power switch off and on. • Execute ‘Engine Maintenance Menu’ to recover the machine after completing the recovery procedure. Otherwise, the machine continues to issue this SC code and cannot be operated. The power should be turned off and on after the recovery procedure.
- Code: 559
- Description: Consecutive Fusing Jam
- Causes: The paper jam counter for the fusing unit reaches 3. The paper jam counter is cleared if the paper is fed correctly. This SC is activated only when this function is enabled with ‘Engine Maintenance’ (default ‘OFF’).
- Troubleshooting Guides: • Defective fusing unit • Defective fusing control 1. Clear this SC to send a command after a jam removal. 2. Turn off this function after a jam removal. • Execute ‘Engine Maintenance Menu’ to recover the machine after completing the recovery procedure. Otherwise, the machine continues to issue this SC code and cannot be operated.
- Code: 669
- Description: EEPROM Error
- Causes: An unexpected value exists in the initialization flag of the EEPROM
- Troubleshooting Guides: • EEPROM not initialized • Defective EEPROM
- Code: 690
- Description: GAVD Communication Error
- Causes: The ID of the GAVD is not identified during initialization. The chip ID of the GAVD cannot be detected by the machine at power-on.
- Troubleshooting Guides: • Defective EGB 1. Replace the EGB. EE
- Code: 819
- Description: Service Cycle Power
- Causes: • Incorrect combination of EGB and controller board. • An unexpected error occurs in the EEPROM on the controller board.
- Troubleshooting Guides: • Controller board defective 1. Install the correct EGB and controller boards for this machine. 2. Replace the controller boardng fan
- Code: 823
- Description: USB/ Network Device Error
- Causes: An interface error in the USB connection or NIB connection occurs.
- Troubleshooting Guides: • Controller board detective 1. Replace the controller board.
- Code: 824
- Description: EEPROM Error
- Causes: An EEPROM check error at power-on occurs.
- Troubleshooting Guides: • Controller board detective 1. Replace the controller board.
- Code: 827
- Description: On-Board Memory Check Error
- Causes: An on-board memory check error at power-on occurs.
- Troubleshooting Guides: • Controller board detective 1. Replace the controller board.
- Code: 828
- Description: ROM Checksum Error
- Causes: A ROM checksum error at power-on occurs.
- Troubleshooting Guides: 1. Replace the controller board.
Epson L8160 Adjustment Program
– OS Support: only Windows Operating System.
– Because Adjprog.exe gets Hardware ID info => Antivirus will misunderstand Adjprog.exe is the virus ==> you need to disable antivirus before extract and run Epson L8160 Adjustment Program or add to exclusion folder
– Limitation: Unlimited using on only 1 Computer.
– Epson L8160 AdjProg or Epson L8160 Adjustment Program or Epson L8160 Adj Program, is a middleware developed by third-party software to supply for Epson L8160 printer, making printer continuous printing without error.
– Epson L8160 Adjustment Program is featured with clearing the waste ink counter, ultra-deep clean to clean the printhead, adjust the smoothness of the printhead, adjust the motor headers, and fix the errors: no printing, lack of colour printing, colour blur, prints with horizontal and vertical stripes…
Epson L8160 Adjustment Functions:
– Bi-D Adjustment
– USB ID Input
– Initial Ink Charge
– Deep Cleaning the Print Head
– Reset Waste Ink Pad Counter
– Head ID Setting
– EEPROM initial setting
– Top margin Adjustment
Using Epson L8160 Adjustment Program
– Choose printer model and usb connection
– Choose Particular Adjustment Mode
– Choose Waste Ink Pad Counter
– Read Waste Ink Pad Counter
– Reset Waste Ink Pad Counter
Active Epson L8160 Adjustment Program
– Run Adjprog.exe, Copy L8160 Hardware ID, send it to admin email : [email protected] to get serial key and then active Epson L8160 Adjustment Program.
– More information about Epson L8160 Adjustment Program: https://shop.nguyendangnam.com/product/epson-l8160-adjustment-program/
– Download Canon driver and firmware in specific model: https://dnasofts.com/canon-ipf8400-printer-driver-firmware-and-user-manual-free-download/
– Download Epson driver and firmware in specific model: https://dnasofts.com/download-epson-ap-5000+-driver-firmware-and-manuals/