Sharp ARC280 Printer with list Error Codes and Epson L850 Adjustment Program
– Printer model: Sharp ARC280
– Error codes on Sharp ARC280 with details instruction fixing:
- Code: A0 0
- Description: ROM trouble (PCU MAIN PWB)
- Causes: Mismatch between ROM and PCU MAIN PWB (mismatch in signal levels)
- Troubleshooting Guides: Case 1 Trouble position/ cause ROM trouble/Improper ROM insertion Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB ROM. (After work) Case 2 Trouble position/ cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power OFFON (After work) Reenter the set values and the adjustment values.
- Code: C1 10
- Description: Main charger trouble (BLACK)
- Causes: ‘In warm-up, the image density sensor detects the transfer belt surface and its output exceeds the specified level.’
- Troubleshooting Guides: Case 1 Trouble position / cause Main charger output trouble (Toner is attached to the transfer drum due to an abnormal output of the main charger in warm-up.) Troubleshooting Guides (Check) ‘Main charger contact check / Main charger unit check / High voltage PWB, high voltage interface PWB check / Main charger output voltage check’ (Repair) ‘Main charger unit replacement / High power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)’ / Power Source-ON (After-work) Execute image density correction (SIM 44-6). / Execute half tone density correction (SIM 44-26). Note Case 2 Trouble position/cause Image density sensor trouble Troubleshooting Guides (Check) ‘Image density sensor check (dirt, output) / Image density sensor calibration plate check / Image density sensor calibration plate switch operation check’ (Repair) ‘Image density sensor cleaning, replacement / Image density sensor calibration plate cleaning, replacement / Image density sensor calibration plate switch solenoid replacement’ / Power Source-ON (After-work) Execute ADJ M6. Note Case 3 Trouble position/cause ‘Transfer belt trouble (dirt, scratches)’ Troubleshooting Guides (Check) ‘Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit’ (Repair) ‘Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning’ / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) PCU MAIN PWB replacement / Power Source-ON (After-work) Re-enter the setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 5 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB image density sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON
- Code: C1 11
- Description: Main charger trouble (CYAN)
- Causes: ‘In warm-up, the image density sensor detects the transfer belt surface and its output exceeds the specified level. ‘
- Troubleshooting Guides: Case 1 Trouble position/cause Main charger output trouble (Toner is attached to the transfer drum due to an abnormal output of the main charger in warm-up.) Troubleshooting Guides (Check) ‘Main charger contact check / Main charger unit check / High voltage PWB, high voltage interface PWB check / Main charger output voltage check’ (Repair) ‘Main charger unit replacement / High power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)’ / Power Source-ON (After-work) Execute image density correction (SIM 44-6). / Execute half tone density correction (SIM 44-26). Note Case 2 Trouble position/cause Image density sensor trouble Troubleshooting Guides (Check) ‘Image density sensor check (dirt, output) / Image density sensor calibration plate check / Image density sensor calibration plate switch operation check’ (Repair) ‘Image density sensor cleaning, replacement / Image density sensor calibration plate cleaning, replacement / Image density sensor calibration plate switch solenoid replacement’ / Power Source-ON (After-work) Execute ADJ M6 Case 3 Trouble position/cause ‘Transfer belt trouble (dirt, scratches)’ Troubleshooting Guides (Check) ‘Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit’ (Repair) ‘Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning’ / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) PCU MAIN PWB replacement / Power Source-ON (After-work) Re-enter the setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 5 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB image density sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON
- Code: C1 12
- Description: Main charger trouble (MAGENTA)
- Causes: ‘In warm-up, the image density sensor detects the transfer belt surface and its output exceeds the specified level. ‘
- Troubleshooting Guides: Case 1 Trouble position/cause Main charger output trouble (Toner is attached to the transfer drum due to an abnormal output of the main charger in warm-up.) Troubleshooting Guides (Check) ‘Main charger contact check / Main charger unit check / High voltage PWB, high voltage interface PWB check / Main charger output voltage check’ (Repair) ‘Main charger unit replacement / High power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)’ / Power Source-ON (After-work) Execute image density correction (SIM 44-6). / Execute half tone density correction (SIM 44-26). Note Case 2 Trouble position/cause Image density sensor trouble Troubleshooting Guides (Check) ‘Image density sensor check (dirt, output) / Image density sensor calibration plate check / Image density sensor calibration plate switch operation check’ (Repair) ‘Image density sensor cleaning, replacement / Image density sensor calibration plate cleaning, replacement / Image density sensor calibration plate switch solenoid replacement’ / Power Source-ON (After-work) Execute ADJ M6. Note Case 3 Trouble position/cause ‘Transfer belt trouble (dirt, scratches)’ Troubleshooting Guides (Check) ‘Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit’ (Repair) ‘Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning’ / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) PCU MAIN PWB replacement / Power Source-ON (After-work) Re-enter the setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 5 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB image density sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON
- Code: C1 13
- Description: Main charger trouble (YELLOW)
- Causes: ‘In warm-up, the image density sensor detects the transfer belt surface and its output exceeds the specified level. ‘
- Troubleshooting Guides: Case 1 Trouble position/cause Main charger output trouble (Toner is attached to the transfer drum due to an abnormal output of the main charger in warm-up.) Troubleshooting Guides (Check) ‘Main charger contact check / Main charger unit check / High voltage PWB, high voltage interface PWB check / Main charger output voltage check’ (Repair) ‘Main charger unit replacement / High power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)’ / Power Source-ON (After-work) Execute image density correction (SIM 44-6). / Execute half tone density correction (SIM 44-26). Note Case 2 Trouble position/cause Image density sensor trouble Troubleshooting Guides (Check) ‘Image density sensor check (dirt, output) / Image density sensor calibration plate check / Image density sensor calibration plate switch operation check’ (Repair) ‘Image density sensor cleaning, replacement / Image density sensor calibration plate cleaning, replacement / Image density sensor calibration plate switch solenoid replacement’ / Power Source-ON (After-work) Execute ADJ M6. Note Case 3 Trouble position/cause ‘Transfer belt trouble (dirt, scratches)’ Troubleshooting Guides (Check) ‘Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit’ (Repair) ‘Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning’ / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) PCU MAIN PWB replacement / Power Source-ON (After-work) Re-enter the setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 5 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB image density sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON
- Code: E7 1
- Description: Image data memory trouble
- Causes: ‘When checking the ICU image data memory (Tandem memory), the memory capacity is judged as less than the specified capacity (128MB).’
- Troubleshooting Guides: Case 1 Trouble position/cause Tandem memory and its peripheral circuit trouble (ICU MAIN PWB trouble) Troubleshooting Guides (Check) Check read/write operation of Tandem memory. (SIM 60-1) (Repair) Replace the ICU MAIN PWB. / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROOM of the defective ICU MAIN PWB to a new ICU MAIN PWB.)
- Code: E7 10
- Description: Shading trouble (Black correction)
- Causes: ‘In shading correction, the CCD black reading level is abnormal (with the scanner lamp OFF).’
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection between the CCD unit and the ICU SCAN PWB Troubleshooting Guides (Check) Check connection of the flat cable between the CCD unit and the ICU SCAN PWB. (Repair) Replace the flat cable between the CCD unit and the ICU SCAN PWB. / Power Source-ON Case 2 Trouble position/cause CCD unit trouble Troubleshooting Guides (Check) Check the CCD black offset level (SIM 46-6). / Check the shading correction result (SIM 63-1). (Repair) Replace the CCD unit. / Power Source-ON (After-work) Adjust ADJM17-ADJ1. Note Case 3 Trouble position/cause ‘ICU SCAN PWB, ICU IMAGE PWB, ICU MAIN PWB trouble’ Troubleshooting Guides (Check) (Repair) ‘Replace ICU SCAN PWB, ICU IMAGE PWB, ICU MAIN PWB.’ / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.)
- Code: E7 11
- Description: Shading trouble (White correction)
- Causes: ‘In shading correction, the CCD white reading level is abnormal (with the scanner lamp OFF).’
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection of the flat cable between the CCD unit and the ICU SCAN PWB. Troubleshooting Guides (Check) Check connection of the flat cable between the CCD unit and the ICU SCAN PWB. (Repair) Replace the flat cable between the CCD unit and the ICU SCAN PWB. / Power Source-ON (After-work) Note Case 2 Trouble position/cause CCD unit trouble Troubleshooting Guides (Check) CCD black offset level check (SIM 46-6) / Shading correction result check (SIM 63-1) (Repair) Replace the CCD unit. / Power Source-ON (After-work) Adjust ADJM17-ADJ1. Note Case 3 Trouble position/cause ‘ICU SCAN PWB, ICU IMAGE PWB, ICU MAIN PWB trouble’ Troubleshooting Guides (Check) (Repair) ‘ICU SCAN PWB, ICU IMAGE PWB, ICU MAIN PWB.’ / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.) Note Case 4 Trouble position/cause ‘Scanner section dirt (Shading sheet trouble (dirt, scratch)/Lens dirt/Mirror dirt/Reflector dirt)’ Troubleshooting Guides (Check) Scanner section dirt check (Repair) Clean the scanner section (shading sheet/lens/CCD/mirror/reflector)./Power Source-ON (After-work) Note Case 5 Trouble position/cause Scanner lamp insufficient light quantity (Scanner lamp trouble/scanner lamp control PWB trouble) Troubleshooting Guides (Check) Check the scanner lamp applying voltage (62.3V) (SIM 5-3). (Repair) Replace the scanner lamp. / Replace the scanner lamp control PWB. / Power Source-ON (After-work) Adjust ADJM17-ADJ1.
- Code: E7 20
- Description: Laser beam sensor trouble (BLACK)
- Causes: The laser beam sensor cannot detect laser beam. (The sensor signal does not change.)
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection of the signal line between the ICU MAIN PWB and the scanner (writing) unit. Troubleshooting Guides (Check) Check connection between the ICU MAIN PWB and the scanner (writing) unit. (Repair) Replace the cable and the connector between the ICU MAIN PWB and the scanner (writing) unit. / Power Source-ON Case 2 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Optical system dirt) Troubleshooting Guides (Check) Check the scanner (writing) unit operation. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10. Note Case 3 Trouble position/cause ICU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the ICU MAIN PWB. / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.) Note Case 4 Trouble position/cause Scanner (writing) unit power line (24V/5V) trouble Troubleshooting Guides (Check) Check the door switch (DSWF). / Check the fuse (F706). (Repair) Replace the door switch (DSWF). / Replace the fuse (F706). / Power Source-ON
- Code: E7 21
- Description: Laser beam sensor trouble (CYAN)
- Causes: The laser beam sensor cannot detect laser beam. (The sensor signal does not change.)
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection of the signal line between the ICU MAIN PWB and the scanner (writing) unit. Troubleshooting Guides (Check) Check connection between the ICU MAIN PWB and the scanner (writing) unit. (Repair) Replace the cable and the connector between the ICU MAIN PWB and the scanner (writing) unit. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble/Laser beam sensor trouble/Optical system dirt) Troubleshooting Guides (Check) Check the scanner (writing) unit operation. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10. Note Case 3 Trouble position/cause ICU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the ICU MAIN PWB. / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.) Note Case 4 Trouble position/cause Scanner (writing) unit power line (24V/5V) trouble Troubleshooting Guides (Check) Check the door switch (DSWF). / Check the fuse (F706). (Repair) Replace the door switch (DSWF). / Replace the fuse (F706). / Power Source-ON
- Code: E7 22
- Description: Laser beam sensor trouble (MAGENTA)
- Causes: The laser beam sensor cannot detect laser beam. (The sensor signal does not change.)
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection of the signal line between the ICU MAIN PWB and the scanner (writing) unit. Troubleshooting Guides (Check) Check connection between the ICU MAIN PWB and the scanner (writing) unit. (Repair) Replace the cable and the connector between the ICU MAIN PWB and the scanner (writing) unit. / Power Source-ON Case 2 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Optical system dirt) Troubleshooting Guides (Check) Check the scanner (writing) unit operation. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10. Note Case 3 Trouble position/cause ICU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the ICU MAIN PWB. / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.) Note Case 4 Trouble position/cause Scanner (writing) unit power line (24V/5V) trouble Troubleshooting Guides (Check) Check the door switch (DSWF). / Check the fuse (F706). (Repair) Replace the door switch (DSWF). / Replace the fuse (F706). / Power Source-ON
- Code: E7 23
- Description: Laser beam sensor trouble (YELLOW)
- Causes: The laser beam sensor cannot detect laser beam. (The sensor signal does not change.)
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection of the signal line between the ICU MAIN PWB and the scanner (writing) unit. Troubleshooting Guides (Check) Check connection between the ICU MAIN PWB and the scanner (writing) unit. (Repair) Replace the cable and the connector between the ICU MAIN PWB and the scanner (writing) unit. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Optical system dirt) Troubleshooting Guides (Check) Check the scanner (writing) unit operation. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10. Note Case 3 Trouble position/cause ICU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the ICU MAIN PWB. / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.) Note Case 4 Trouble position/cause Scanner (writing) unit power line (24V/5V) trouble Troubleshooting Guides (Check) Check the door switch (DSWF). / Check the fuse (F706). (Repair) Replace the door switch (DSWF). / Replace the fuse (F706). / Power Source-ON
- Code: E7 24
- Description: Laser beam detection trouble (BLACK)
- Causes: The laser beam sensor cannot detect laser beam. (The sensor signal does not change.)
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection of the signal line between the ICU MAIN PWB and the scanner (writing) unit. Troubleshooting Guides (Check) Check connection between the ICU MAIN PWB and the scanner (writing) unit. (Repair) Replace the cable and the connector between the ICU MAIN PWB and the scanner (writing) unit. / Power Source-ON Case 2 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Optical system dirt) Troubleshooting Guides (Check) Check the scanner (writing) unit operation. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10. Note Case 3 Trouble position/cause ICU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the ICU MAIN PWB. / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.) Note Case 4 Trouble position/cause Scanner (writing) unit power line (24V/5V) trouble Troubleshooting Guides (Check) Check the door switch (DSWF). / Check the fuse (F706). (Repair) Replace the door switch (DSWF). / Replace the fuse (F706). / Power Source-ON
- Code: E7 25
- Description: Laser beam detection trouble (CYAN)
- Causes: The laser beam sensor cannot detect laser beam. (The sensor signal does not change.)
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection of the signal line between the ICU MAIN PWB and the scanner (writing) unit. Troubleshooting Guides (Check) Check connection between the ICU MAIN PWB and the scanner (writing) unit. (Repair) Replace the cable and the connector between the ICU MAIN PWB and the scanner (writing) unit. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Optical system dirt) Troubleshooting Guides (Check) Check the scanner (writing) unit operation. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10. Note Case 3 Trouble position/cause ICU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the ICU MAIN PWB. / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.) Note Case 4 Trouble position/cause Scanner (writing) unit power line (24V/5V) trouble Troubleshooting Guides (Check) Check the door switch (DSWF). / Check the fuse (F706). (Repair) Replace the door switch (DSWF). / Replace the fuse (F706). / Power Source-ON
- Code: E7 26
- Description: Laser beam detection trouble (MAGENTA)
- Causes: The laser beam sensor cannot detect laser beam. (The sensor signal does not change.)
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection of the signal line between the ICU MAIN PWB and the scanner (writing) unit. Troubleshooting Guides (Check) Check connection between the ICU MAIN PWB and the scanner (writing) unit. (Repair) Replace the cable and the connector between the ICU MAIN PWB and the scanner (writing) unit. / Power Source-ON Case 2 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Optical system dirt) Troubleshooting Guides (Check) Check the scanner (writing) unit operation. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10. Note Case 3 Trouble position/cause ICU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the ICU MAIN PWB. / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.) Note Case 4 Trouble position/cause Scanner (writing) unit power line (24V/5V) trouble Troubleshooting Guides (Check) Check the door switch (DSWF). / Check the fuse (F706). (Repair) Replace the door switch (DSWF). / Replace the fuse (F706). / Power Source-ON
- Code: E7 27
- Description: Laser beam detection trouble (YELLOW)
- Causes: The laser beam sensor cannot detect laser beam. (The sensor signal does not change.)
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection of the signal line between the ICU MAIN PWB and the scanner (writing) unit. Troubleshooting Guides (Check) Check connection between the ICU MAIN PWB and the scanner (writing) unit. (Repair) Replace the cable and the connector between the ICU MAIN PWB and the scanner (writing) unit. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Optical system dirt) Troubleshooting Guides (Check) Check the scanner (writing) unit operation. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10. Note Case 3 Trouble position/cause ICU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the ICU MAIN PWB. / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.) Note Case 4 Trouble position/cause Scanner (writing) unit power line (24V/5V) trouble Troubleshooting Guides (Check) Check the door switch (DSWF). / Check the fuse (F706). (Repair) Replace the door switch (DSWF). / Replace the fuse (F706). / Power Source-ON
- Code: E7 30
- Description: ICU PWB FLASH ROM trouble
- Causes: ‘After turning ON the power, consistency of the ICU MAIN PWB and the ROM (FLASH ROM) is checked and no consistency is found.’
- Troubleshooting Guides: Case 1 Trouble position/cause ICUMAIN PWB trouble / ICU MAIN PWB ROM(FLASH ROM) trouble Troubleshooting Guides (Check) Check whether the installed ICU MAIN PWB or the ICU FLASH ROM is of the other model (AR-C100/150). (Repair) Replace the ICUMAIN PWB. / Replace the ICU MAIN PWB ROM(FLASH ROM). / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.)
- Code: E7 90
- Description: ICUMAIN PWB – PCU MAIN PWB communication trouble (PCU side detection)
- Causes: Caused by line noise on the data line (Hardware trouble)
- Troubleshooting Guides: Case 1 Trouble position/cause PCUMAIN PWB / ICU MAIN PWB signal line connection trouble Troubleshooting Guides (Check) Check connection of the signal line between the PCUMAIN PWB and the ICU MAIN PWB. (Repair) Repair or replace the cable and the connector between the PCUMAIN PWB and the ICU MAIN PWB. / Power Source-ON (After-work) Note Case 2 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 3 Trouble position/cause ICU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) ICUMAIN PWB / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.)
– Sharp ARC280 printer Error Codes and quick guide on repairing:
- Code: E8 0
- Description: ICUMAIN PWB – PCU MAIN PWB communication trouble (PCU side detection)
- Causes: No response from ICU PWB for PCU PWB command (Caused by Hardware trouble)
- Troubleshooting Guides: Case 1 Trouble position/cause PCUMAIN PWB / ICU MAIN PWB signal line connection trouble Troubleshooting Guides (Check) Check connection of the signal line between the PCUMAIN PWB and the ICU MAIN PWB. (Repair) Repair or replace the cable and the connector between the PCUMAIN PWB and the ICU MAIN PWB. / Power Source-ON (After-work) Note Case 2 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 3 Trouble position/cause ICU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) ICUMAIN PWB / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.)
- Code: E8 1
- Description: ICUMAIN PWB – PCU MAIN PWB communication trouble (PCU side detection)
- Causes: No response from ICU PWB for PCU PWB command (Caused by software trouble)
- Troubleshooting Guides: Case 1 Trouble position/cause PCUMAIN PWB / ICU MAIN PWB signal line connection trouble Troubleshooting Guides (Check) Check connection of the signal line between the PCUMAIN PWB and the ICU MAIN PWB. (Repair) Repair or replace the cable and the connector between the PCUMAIN PWB and the ICU MAIN PWB. / Power Source-ON (After-work) Note Case 2 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 3 Trouble position/cause ICU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) ICUMAIN PWB / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.)
- Code: EE EL
- Description: Toner concentration reference control level setup trouble (Overtoner)
- Causes: ‘When setting the toner concentration reference control level , the toner concentration sensor output is not within the specified range. (The output level is 77 or less.)’
- Troubleshooting Guides: Case 1 Trouble position/cause Toner density sensor trouble / Toner density sensor signal line connection trouble Troubleshooting Guides (Check) Check the toner concentration output level with SIM 25-1. (Repair) Toner concentration sensor replacement (Developing unit replacement) / Power Source-ON (After-work) Execute ADJ M3. Note Case 2 Trouble position/cause Process control PWB trouble Troubleshooting Guides (Check) (Repair) Process control PWB replacement / Power Source-ON Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) PCU MAIN PWB replacement / Power Source-ON (After-work) Re-enter the setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: EE EU
- Description: Toner concentration reference control level setup trouble (Undertoner)
- Causes: ‘When setting the toner concentration reference control level , the toner concentration sensor output is not within the specified range. (The output level is179 or above.)’
- Troubleshooting Guides: Case 1 Trouble position/cause Toner density sensor trouble / Toner density sensor signal line connection trouble Troubleshooting Guides (Check) Check the toner concentration output level with SIM 25-1. (Repair) Toner concentration sensor replacement (Developing unit replacement) / Power Source-ON (After-work) Execute ADJ M3. Note Case 2 Trouble position/cause Process control PWB trouble Troubleshooting Guides (Check) Check the toner concentration sensor output level with SIM 25-1. (Repair) Process control PWB replacement / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) Check the toner concentration sensor output level with SIM 25-1. (Repair) PCU MAIN PWB replacement / Power Source-ON (After-work) Re-enter the setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: F1 70
- Description: PCU PWB – sorter control PWB communication trouble (PCU detection)
- Causes: Communication test error after turning ON the power or canceling a simulation.
- Troubleshooting Guides: Case 1 Trouble position/cause PCU MAIN PWB – Sorter signal line connection trouble Troubleshooting Guides (Check) Check connection of the signal line between the PCU MAIN PWB and the sorter. (Repair) Repair or replace the cable and the connector between the PCUMAIN PWB and the ICU MAIN PWB. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Sorter control PWB trouble Troubleshooting Guides (Check) (Repair) Replace the sorter control PWB. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: F1 80
- Description: Sorter power abnormality (Sorter side detection)
- Causes: Sorter control PWB +24V power abnormality (Low voltage)
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection between the DC main PWB and the sorter control PWB. Troubleshooting Guides (Check) Check connection between the DC main PWB and the sorter control PWB. (Repair) Repair or replace the harness and the connector between the DC main PWB and the sorter control PWB. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Sorter control PWB trouble Troubleshooting Guides (Check) Check the power source in the sorter control PWB. (SIM 3-2) (Repair) Replace the sorter control PWB. / Power Source-ON
- Code: F1 81
- Description: Sorter transport motor trouble (Sorter side detection)
- Causes: The motor rotation sensor output signal is not recognized within the specified time after outputting the sorter transport motor ON signal. / The transport guide sensor signal is not recognized within the specified time after outputting the transport guide ON signal.
- Troubleshooting Guides: Case 1 Trouble position/cause Transport motor trouble / Transport motor rotation sensor trouble Troubleshooting Guides (Check) ‘Check operations of the transport motor, the transport guide, and the sensor. (SIM 3-1/2)’ (Repair) Replace the transport motor. / Replace the transport motor rotation sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause ‘Transport guide sensor trouble, transport guide home position sensor trouble’ Troubleshooting Guides (Check) Check operations of the transport guide sensor and the transport guide home position sensor. (SIM 3-1/2) (Repair) Replace the transport guide sensor. / Replace the transport guide home position sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Paper transport mechanism section trouble Troubleshooting Guides (Check) Check operations of the paper transport mechanism section. (SIM 3-1/2) (Repair) Repair or replace the parts of the paper transport mechanism section. / Power Source-ON (After-work) Note Case 4 Trouble position/cause Sorter control PWB trouble. Troubleshooting Guides (Check) Check operations of the sorter control PWB. (SIM 3-1/2) (Repair) Replace the sorter control PWB. / Power Source-ON
- Code: F1 83
- Description: Sorter push bar motor trouble (Sorter side detection)
- Causes: The push bar sensor signal is not recognized within 2sec from start of initializing. / The push bar does not complete its operation within 2sec from start of operation
- Troubleshooting Guides: Case 1 Trouble position/cause Push bar motor trouble / Push bar home position sensor trouble Troubleshooting Guides (Check) Check operations of the push bar motor and the push bar home position sensor. (SIM 3-1/2) (Repair) Replace the push bar motor. / Replace the push bar home position sensor. / Power Source-ON Case 2 Trouble position/cause Circuit breaker operation Troubleshooting Guides (Check) Check the cause of an overcurrent. (Repair) Reset the circuit breaker. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Paper push bar mechanism section trouble Troubleshooting Guides (Check) Check operations of the paper push bar mechanism section. (SIM3-1/2) (Repair) Repair or replace the parts in the paper push bar mechanism section. / Power Source-ON (After-work) Note Case 4 Trouble position/cause Sorter control PWB trouble. Troubleshooting Guides (Check) Check operations of the sorter control PWB.(SIM3-1/2) (Repair) Replace the sorter control PWB. / Power Source-ON
- Code: F1 87
- Description: Sorter staple unit oscillation motor trouble (Sorter side detection)
- Causes: The stapler shift home position sensor signal is not recognized within 1sec from start of initializing. / The stapler shift home position sensor signal polarity change is not recognized within 1sec from start of stapler shift operation. / The rotation sensor output signal is not recognized within 0.25sec from output of the stapler shift motor ON signal.
- Troubleshooting Guides: Case 1 Trouble position/cause Stapler shift motor trouble / Stapler shift home position sensor trouble Troubleshooting Guides (Check) Check operations of the stapler shift motor/stapler shift home position sensor.(SIM3-1/2) (Repair) Replace the stapler shift motor. / Replace the stapler shift home position sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Staple shift mechanism section trouble Troubleshooting Guides (Check) Check operations of the staple shift mechanism section. (SIM3-1/2) (Repair) Repair or replace the parts of the staple shift mechanism section. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Circuit breaker operation Troubleshooting Guides (Check) Check the cause of an overcurrent. (Repair) Reset the circuit breaker. / Power Source-ON (After-work) Note Case 4 Trouble position/cause Sorter control PWB trouble. Troubleshooting Guides (Check) Check operations of the sorter control PWB.(SIM3-1/2) (Repair) Replace the sorter control PWB. / Power Source-ON
- Code: F1 89
- Description: Sorter bin shift motor trouble (Sorter side detection)
- Causes: The lead cam position sensor signal is not recognized within the specified time after outputting the bin shift motor ON signal. / The guide bar home position is not recognized within the specified time after start of the guide bar operation. / The rotation sensor output signal is not recognized within the specified time after outputting the bin shift motor ON signal.
- Troubleshooting Guides: Case 1 Trouble position/cause Bin shift motor trouble / Lead cam position sensor Troubleshooting Guides (Check) Check operations of the bin shift motor / lead cam home position sensor. (SIM3-1/2) (Repair) Replace the bin shift motor. / Replace the lead cam position sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bin shift mechanism section trouble Troubleshooting Guides (Check) Check operations of the bin shift mechanism section. (SIM 3-1/2) (Repair) Repair or replace the parts in the bin shift mechanism section. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Circuit breaker operation Troubleshooting Guides (Check) Check the cause of an overcurrent. (Repair) Reset the circuit breaker. / Power Source-ON (After-work) Note Case 4 Trouble position/cause Sorter control PWB trouble. Troubleshooting Guides (Check) Check operations of the sorter control PWB.(SIM3-1/2) (Repair) Replace the sorter control PWB. / Power Source-ON
- Code: F1 91
- Description: Bin paper sensor auto adjustment trouble (Sorter side detection)
- Causes: Sensor output abnormality in sensor detection level adjustment
- Troubleshooting Guides: Case 1 Trouble position/cause Bin paper sensor trouble Troubleshooting Guides (Check) Check operations of bin paper sensor.(SIM3-1/2) (Repair) Replace or adjust the bin paper sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Sorter control PWB trouble. Troubleshooting Guides (Check) Check operations of the sorter control PWB.(SIM3-1/2) (Repair) Replace the sorter control PWB. / Power Source-ON
- Code: F1 94
- Description: Sorter staple key trouble
- Causes: The continuous ON state of the manual staple key is recognized after 5 sec of starting copying.
- Troubleshooting Guides: Case 1 Trouble position/cause Staple key trouble Troubleshooting Guides (Check) Staple key operation check (SIM 3-2) (Repair) Staple key replacement/Power OFF/ON (After-work) Note Case 2 Trouble position/cause Sorter control PWB trouble. Troubleshooting Guides (Check) Sorter control PWB operation check (SIM 3-1/2) (Repair) Sorter control PWB replacement/Power OFF/ON
- Code: F2 40
- Description: Toner concentration sensor trouble (BLACK)
- Causes: Toner density sensor output line open
- Troubleshooting Guides: Case 1 Trouble position/cause ‘Bad connection of the toner density sensor, the process control PWB, and the PCU MAIN PWB’ Troubleshooting Guides (Check) ‘Check connections of the toner density sensor, the process control PWB, and the PCU MAIN PWB.’ (Repair) Replace the toner density sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Process control PWB trouble Troubleshooting Guides (Check) Check the toner density sensor output level with SIM 25-1. (Repair) Replace the process control PWB. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) Check the toner density sensor output level with SIM 25-1. (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: F2 41
- Description: Toner concentration sensor trouble (CYAN)
- Causes: Toner density sensor output line open
- Troubleshooting Guides: Case 1 Trouble position/cause ‘Bad connection of the toner density sensor, the process control PWB, and the PCU MAIN PWB’ Troubleshooting Guides (Check) ‘Check connections of the toner density sensor, the process control PWB, and the PCU MAIN PWB.’ (Repair) Replace the toner density sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Process control PWB trouble Troubleshooting Guides (Check) Check the toner density sensor output level with SIM 25-1. (Repair) Replace the process control PWB. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) Check the toner density sensor output level with SIM 25-1. (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: F2 42
- Description: Toner concentration sensor trouble (MAGENTA)
- Causes: Toner density sensor output line open
- Troubleshooting Guides: Case 1 Trouble position/cause ‘Bad connection of the toner density sensor, the process control PWB, and the PCU MAIN PWB’ Troubleshooting Guides (Check) ‘Check connections of the toner density sensor, the process control PWB, and the PCU MAIN PWB.’ (Repair) Replace the toner density sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Process control PWB trouble Troubleshooting Guides (Check) Check the toner density sensor output level with SIM 25-1. (Repair) Replace the process control PWB. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) Check the toner density sensor output level with SIM 25-1. (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: F2 43
- Description: Toner concentration sensor trouble (YELLOW)
- Causes: Toner density sensor output line open
- Troubleshooting Guides: Case 1 Trouble position/cause ‘Bad connection of the toner density sensor, the process control PWB, and the PCU MAIN PWB’ Troubleshooting Guides (Check) ‘Check connections of the toner density sensor, the process control PWB, and the PCU MAIN PWB.’ (Repair) Replace the toner density sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Process control PWB trouble Troubleshooting Guides (Check) Check the toner density sensor output level with SIM 25-1. (Repair) Replace the process control PWB. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) Check the toner density sensor output level with SIM 25-1. (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: F2 44
- Description: Image density sensor trouble (BLACK) (Transfer belt surface reflection abnormality)
- Causes: ‘In the image density correction, the transfer belt surface is read by the image density sensor and the sensor gain is adjusted so that the output becomes a fixed value. However, the output of the specified range cannot be obtained even though the sensor gain is changed.’
- Troubleshooting Guides: Case 1 Trouble position/cause Image density sensor trouble Troubleshooting Guides (Check) ‘Check the image density sensor (dirt, output)(SIM44-2) / Check the image density sensor calibration plate. / Check the operation of the image density sensor calibration plate switching.’ (Repair) Clean or replace the image density sensor. / Clean or replace the image density sensor calibration plate. / Replace the image density sensor calibration plate switch solenoid. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause ‘Transfer belt trouble (dirt, scratch)’ Troubleshooting Guides (Check) ‘Toner dispersion from the transfer belt, the OPC drum unit, and the developing unit’ (Repair) Clean or replace the transfer belt. / Replace the transfer belt cleaner. / Clean the OPC drum and the developing unit. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUM PWB image density sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON
- Code: F2 45
- Description: Image density sensor trouble (COLOR)(Calibration plate reflection abnormality)
- Causes: ‘In the image density correction, the transfer belt surface is read by the image density sensor and the sensor gain is adjusted so that the output becomes a fixed value. However, the output of the specified range cannot be obtained even though the sensor gain is changed.’
- Troubleshooting Guides: Case 1 Trouble position/cause Image density sensor trouble Troubleshooting Guides (Check) ‘Check the image density sensor (dirt, output)(SIM44-2) / Check the image density sensor calibration plate. / Check the operation of the image density sensor calibration plate switching.’ (Repair) Clean or replace the image density sensor. / Clean or replace the image density sensor calibration plate. / Replace the image density sensor calibration plate switch solenoid. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause ‘Transfer belt trouble (dirt, scratch)’ Troubleshooting Guides (Check) ‘Toner dispersion from the transfer belt, the OPC drum unit, and the developing unit’ (Repair) Clean or replace the transfer belt. / Replace the transfer belt cleaner. / Clean the OPC drum and the developing unit. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUM PWB image density sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON
- Code: F2 50
- Description: Drum marking detection trouble (BLACK)
- Causes: The drum marking is not recognized. / The size and the number of drum markings are not specified ones.
- Troubleshooting Guides: Case 1 Trouble position/cause ‘Drum marking sensor trouble (dirt, output)’ Troubleshooting Guides (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. Troubleshooting Guides (Check) Check connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. (Repair) Repair or replace the cable and the connector between PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause ‘OPC drum surface dirt, scratch / A different type of OPC drum is installed.’ Troubleshooting Guides (Check) ‘Check dirt and scratches on the OPC drum surface, and the type of OPC drum.’ (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
- Code: F2 51
- Description: Drum marking detection trouble (CYAN)
- Causes: The drum marking is not recognized. / The size and the number of drum markings are not specified ones.
- Troubleshooting Guides: Case 1 Trouble position/cause ‘Drum marking sensor trouble (dirt, output)’ Troubleshooting Guides (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. Troubleshooting Guides (Check) Check connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. (Repair) Repair or replace the cable and the connector between PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause ‘OPC drum surface dirt, scratch / A different type of OPC drum is installed.’ Troubleshooting Guides (Check) ‘Check dirt and scratches on the OPC drum surface, and the type of OPC drum.’ (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
- Code: F2 52
- Description: Drum marking detection trouble (MAGENTA)
- Causes: The drum marking is not recognized. / The size and the number of drum markings are not specified ones.
- Troubleshooting Guides: Case 1 Trouble position/cause ‘Drum marking sensor trouble (dirt, output)’ Troubleshooting Guides (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. Troubleshooting Guides (Check) Check connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. (Repair) Repair or replace the cable and the connector between PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause ‘OPC drum surface dirt, scratch / A different type of OPC drum is installed.’ Troubleshooting Guides (Check) ‘Check dirt and scratches on the OPC drum surface, and the type of OPC drum.’ (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
- Code: F2 53
- Description: Drum marking detection trouble (YELLOW)
- Causes: The drum marking is not recognized. / The size and the number of drum markings are not specified ones.
- Troubleshooting Guides: Case 1 Trouble position/cause ‘Drum marking sensor trouble (dirt, output)’ Troubleshooting Guides (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. Troubleshooting Guides (Check) Check connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. (Repair) Repair or replace the cable and the connector between PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Case 4 Trouble position/cause ‘OPC drum surface dirt, scratch / A different type of OPC drum is installed.’ Troubleshooting Guides (Check) ‘Check dirt and scratches on the OPC drum surface, and the type of OPC drum.’ (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
- Code: F2 54
- Description: Drum marking sensor gain adjustment error (BLACK)
- Causes: ‘In the image density correction, the transfer belt surface is read by the image density sensor and the sensor gain is adjusted so that the output becomes a fixed value. However, the output of the specified range cannot be obtained even though the sensor gain is changed.’
- Troubleshooting Guides: Case 1 Trouble position/cause ‘Drum marking sensor trouble (dirt, output) ‘ Troubleshooting Guides (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line between PCU MAIN PWB / Process control PWB / Drum marking sensor Troubleshooting Guides (Check) Check connection of the signal line between PCU MAIN PWB / Process control PWB / Drum marking sensor. (Repair) Repair or replacement of the cable and the connector between the PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause ‘OPC drum surface dirt, scratch / A different type of OPC drum is installed.’ Troubleshooting Guides (Check) ‘Check dirt and scratches on the OPC drum surface, and the type of OPC drum.’ (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
- Code: F2 55
- Description: Drum marking sensor gain adjustment error (CYAN)
- Causes: ‘In the image density correction, the transfer belt surface is read by the image density sensor and the sensor gain is adjusted so that the output becomes a fixed value. However, the output of the specified range cannot be obtained even though the sensor gain is changed.’
- Troubleshooting Guides: Case 1 Trouble position/cause ‘Drum marking sensor trouble (dirt, output) ‘ Troubleshooting Guides (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON Case 2 Trouble position/cause Bad connection of the signal line between PCU MAIN PWB / Process control PWB / Drum marking sensor Troubleshooting Guides (Check) Check connection of the signal line between PCU MAIN PWB / Process control PWB / Drum marking sensor. (Repair) Repair or replacement of the cable and the connector between the PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause ‘OPC drum surface dirt, scratch / A different type of OPC drum is installed.’ Troubleshooting Guides (Check) ‘Check dirt and scratches on the OPC drum surface, and the type of OPC drum.’ (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
- Code: F2 56
- Description: Drum marking sensor gain adjustment error (MAGENTA)
- Causes: ‘In the image density correction, the transfer belt surface is read by the image density sensor and the sensor gain is adjusted so that the output becomes a fixed value. However, the output of the specified range cannot be obtained even though the sensor gain is changed.’
- Troubleshooting Guides: Case 1 Trouble position/cause ‘Drum marking sensor trouble (dirt, output) ‘ Troubleshooting Guides (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line between PCU MAIN PWB / Process control PWB / Drum marking sensor Troubleshooting Guides (Check) Check connection of the signal line between PCU MAIN PWB / Process control PWB / Drum marking sensor. (Repair) Repair or replacement of the cable and the connector between the PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause ‘OPC drum surface dirt, scratch / A different type of OPC drum is installed.’ Troubleshooting Guides (Check) ‘Check dirt and scratches on the OPC drum surface, and the type of OPC drum.’ (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
- Code: F2 57
- Description: Drum marking sensor gain adjustment error (YELLOW)
- Causes: ‘In the image density correction, the transfer belt surface is read by the image density sensor and the sensor gain is adjusted so that the output becomes a fixed value. However, the output of the specified range cannot be obtained even though the sensor gain is changed.’
- Troubleshooting Guides: Case 1 Trouble position/cause ‘Drum marking sensor trouble (dirt, output) ‘ Troubleshooting Guides (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line between PCU MAIN PWB / Process control PWB / Drum marking sensor Troubleshooting Guides (Check) Check connection of the signal line between PCU MAIN PWB / Process control PWB / Drum marking sensor. (Repair) Repair or replacement of the cable and the connector between the PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause ‘OPC drum surface dirt, scratch / A different type of OPC drum is installed.’ Troubleshooting Guides (Check) ‘Check dirt and scratches on the OPC drum surface, and the type of OPC drum.’ (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
- Code: F2 58
- Description: Process humidity sensor trouble
- Causes: Humidity concentration sensor output line open
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection between the image density sensor and the PCU SUB PWB. Troubleshooting Guides (Check) Check connection of the image density sensor and the PCU SUB PWB. (Repair) Replace the image density sensor. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB humidity sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON
- Code: F2 63
- Description: Temperature sensor trouble (Image process)
- Causes: Temperature sensor (image process) output line open
- Troubleshooting Guides: Case 1 Trouble position/cause ‘Bad connection of the temperature sensor, the process control PWB, and the PCU MAIN PWB.’ Troubleshooting Guides (Check) ‘Check connection of the temperature sensor, the process control PWB, and the PCU MAIN PWB.’ (Repair) Replace the temperature sensor (process control PWB). / Power Source-ON (After-work) Note Case 2 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) Check the output level of the PCU MAIN PWB humidity sensor. (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: F2 80
- Description: Half tone correction (1st patch) trouble (BLACK)
- Causes: ‘In half tone image density correction, the toner patch density is abnormally low or high.’
- Troubleshooting Guides: Case 1 Trouble position/cause Image density sensor trouble Troubleshooting Guides (Check) ‘Check the image density sensor (dirt, output).(SIM44-2)’ (Repair) Clean or replace the image density sensor. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause ‘Transfer belt trouble (dirt, scratch)’ Troubleshooting Guides (Check) ‘Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit’ (Repair) ‘Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning’ / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB humidity sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 5 Trouble position/cause Main charger output trouble Troubleshooting Guides (Check) ‘Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check ‘ (Repair) ‘Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)’ / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 6 Trouble position/cause Developing bias output trouble Troubleshooting Guides (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Case 7 Trouble position/cause Transfer trouble Troubleshooting Guides (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Troubleshooting Guides (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10
- Code: F2 81
- Description: Half tone correction (1st patch) trouble (CYAN)
- Causes: ‘In half tone image density correction, the toner patch density is abnormally low or high.’
- Troubleshooting Guides: Case 1 Trouble position/cause Image density sensor trouble Troubleshooting Guides (Check) ‘Check the image density sensor (dirt, output).(SIM44-2)’ (Repair) Clean or replace the image density sensor. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause ‘Transfer belt trouble (dirt, scratch)’ Troubleshooting Guides (Check) ‘Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit’ (Repair) ‘Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning’ / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB humidity sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 5 Trouble position/cause Main charger output trouble Troubleshooting Guides (Check) ‘Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check ‘ (Repair) ‘Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)’ / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 6 Trouble position/cause Developing bias output trouble Troubleshooting Guides (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Case 7 Trouble position/cause Transfer trouble Troubleshooting Guides (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Troubleshooting Guides (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10
- Code: F2 82
- Description: Half tone correction (1st patch) trouble (MAGENTA)
- Causes: ‘In half tone image density correction, the toner patch density is abnormally low or high.’
- Troubleshooting Guides: Case 1 Trouble position/cause Image density sensor trouble Troubleshooting Guides (Check) ‘Check the image density sensor (dirt, output).(SIM44-2)’ (Repair) Clean or replace the image density sensor. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause ‘Transfer belt trouble (dirt, scratch)’ Troubleshooting Guides (Check) ‘Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit’ (Repair) ‘Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning’ / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB humidity sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 5 Trouble position/cause Main charger output trouble Troubleshooting Guides (Check) ‘Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check ‘ (Repair) ‘Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)’ / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 6 Trouble position/cause Developing bias output trouble Troubleshooting Guides (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Case 7 Trouble position/cause Transfer trouble Troubleshooting Guides (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Troubleshooting Guides (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10
- Code: F2 83
- Description: Half tone correction (1st patch) trouble (YELLOW)
- Causes: ‘In half tone image density correction, the toner patch density is abnormally low or high.’
- Troubleshooting Guides: Case 1 Trouble position/cause Image density sensor trouble Troubleshooting Guides (Check) ‘Check the image density sensor (dirt, output).(SIM44-2)’ (Repair) Clean or replace the image density sensor. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause ‘Transfer belt trouble (dirt, scratch)’ Troubleshooting Guides (Check) ‘Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit’ (Repair) ‘Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning’ / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB humidity sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 5 Trouble position/cause Main charger output trouble Troubleshooting Guides (Check) ‘Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check ‘ (Repair) ‘Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)’ / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Case 6 Trouble position/cause Developing bias output trouble Troubleshooting Guides (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 7 Trouble position/cause Transfer trouble Troubleshooting Guides (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Troubleshooting Guides (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10
- Code: F2 84
- Description: Half tone correction (2nd patch) trouble (BLACK)
- Causes: ‘In the half toner image density correction, the toner patch densities at the boundary sections of the low density area, the medium density area, and the high density area are abnormally different from each other.’
- Troubleshooting Guides: Case 1 Trouble position/cause Image density sensor trouble Troubleshooting Guides (Check) ‘Check the image density sensor (dirt, output).(SIM44-2)’ (Repair) Clean or replace the image density sensor. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause ‘Transfer belt trouble (dirt, scratch)’ Troubleshooting Guides (Check) ‘Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit’ (Repair) ‘Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning’ / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB humidity sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Case 5 Trouble position/cause Main charger output trouble Troubleshooting Guides (Check) ‘Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check ‘ (Repair) ‘Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)’ / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 6 Trouble position/cause Developing bias output trouble Troubleshooting Guides (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 7 Trouble position/cause Transfer trouble Troubleshooting Guides (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Troubleshooting Guides (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10
- Code: F2 85
- Description: Half tone correction (2nd) patch trouble (CYAN)
- Causes: ‘In the half toner image density correction, the toner patch densities at the boundary sections of the low density area, the medium density area, and the high density area are abnormally different from each other.’
- Troubleshooting Guides: Case 1 Trouble position/cause Image density sensor trouble Troubleshooting Guides (Check) ‘Check the image density sensor (dirt, output).(SIM44-2)’ (Repair) Clean or replace the image density sensor. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause ‘Transfer belt trouble (dirt, scratch)’ Troubleshooting Guides (Check) ‘Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit’ (Repair) ‘Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning’ / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB humidity sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Case 5 Trouble position/cause Main charger output trouble Troubleshooting Guides (Check) ‘Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check ‘ (Repair) ‘Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)’ / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 6 Trouble position/cause Developing bias output trouble Troubleshooting Guides (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 7 Trouble position/cause Transfer trouble Troubleshooting Guides (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Troubleshooting Guides (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10
- Code: F2 86
- Description: Half tone correction (2nd) patch trouble (MAGENTA)
- Causes: ‘In the half toner image density correction, the toner patch densities at the boundary sections of the low density area, the medium density area, and the high density area are abnormally different from each other.’
- Troubleshooting Guides: Case 1 Trouble position/cause Image density sensor trouble Troubleshooting Guides (Check) ‘Check the image density sensor (dirt, output).(SIM44-2)’ (Repair) Clean or replace the image density sensor. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause ‘Transfer belt trouble (dirt, scratch)’ Troubleshooting Guides (Check) ‘Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit’ (Repair) ‘Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning’ / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB humidity sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Case 5 Trouble position/cause Main charger output trouble Troubleshooting Guides (Check) ‘Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check ‘ (Repair) ‘Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)’ / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 6 Trouble position/cause Developing bias output trouble Troubleshooting Guides (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 7 Trouble position/cause Transfer trouble Troubleshooting Guides (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Troubleshooting Guides (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10
- Code: F2 87
- Description: Half tone correction (2nd) patch trouble (YELLOW)
- Causes: ‘In the half toner image density correction, the toner patch densities at the boundary sections of the low density area, the medium density area, and the high density area are abnormally different from each other.’
- Troubleshooting Guides: Case 1 Trouble position/cause Image density sensor trouble Troubleshooting Guides (Check) ‘Check the image density sensor (dirt, output).(SIM44-2)’ (Repair) Clean or replace the image density sensor. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause ‘Transfer belt trouble (dirt, scratch)’ Troubleshooting Guides (Check) ‘Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit’ (Repair) ‘Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning’ / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB humidity sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Case 5 Trouble position/cause Main charger output trouble Troubleshooting Guides (Check) ‘Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check ‘ (Repair) ‘Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)’ / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 6 Trouble position/cause Developing bias output trouble Troubleshooting Guides (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 7 Trouble position/cause Transfer trouble Troubleshooting Guides (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Troubleshooting Guides (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10
- Code: F2 90
- Description: Half tone correction trouble
- Causes: The max. value of the difference (between colors) between the half tone correction value and the previous correction value exceeds the specified level.
- Troubleshooting Guides: Case 1 Trouble position/cause Image density sensor trouble Troubleshooting Guides (Check) ‘Check the image density sensor (dirt, output)(SIM44-2) / Check the image density sensor calibration plate. / Check the operation of the image density sensor calibration plate switching.’ (Repair) Clean or replace the image density sensor. / Clean or replace the image density sensor calibration plate. / Replace the image density sensor calibration plate switch solenoid. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause ‘Transfer belt trouble (dirt, scratch)’ Troubleshooting Guides (Check) ‘Toner dispersion from the transfer belt, the OPC drum unit, and the developing unit’ (Repair) Clean or replace the transfer belt. / Replace the transfer belt cleaner. / Clean the OPC drum and the developing unit. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB image density sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Case 5 Trouble position/cause Main charger output trouble Troubleshooting Guides (Check) ‘Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check ‘ (Repair) ‘Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)’ / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 6 Trouble position/cause Developing bias output trouble Troubleshooting Guides (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 7 Trouble position/cause Transfer trouble Troubleshooting Guides (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Troubleshooting Guides (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10
- Code: F3 12
- Description: Lift up trouble (Paper 1)
- Causes: Lifting is not completed (LUD1) is not turned ON) within the specified time after turning ON the lift motor.
- Troubleshooting Guides: Case 1 Trouble position/cause LUD1 detector trouble Troubleshooting Guides (Check) Check operation of the LUD1 detector (SIM 30-2). (Repair) Replace the LUD1 detector. / Power Source-ON (After-work) Note Case 2 Trouble position/cause ‘Lift mechanism (motor, etc.) trouble’ Troubleshooting Guides (Check) ‘Check operations of the lift mechanism section (motor, etc.).’ (Repair) replace the e lift unit. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Bad connection between the PCU MAIN PWB and the lift unit. Troubleshooting Guides (Check) Check connection between the PCU MAIN PWB and the lift unit. (Repair) Repair or replace the connector and cables of the PCU MAIN PWB and the lift unit. / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: F3 22
- Description: Lift up trouble (Paper 2)
- Causes: Lifting is not completed (LUD2) is not turned ON) within the specified time after turning ON the lift motor.
- Troubleshooting Guides: Case 1 Trouble position/cause LUD2 detector trouble Troubleshooting Guides (Check) Check operation of the LUD2 detector (SIM 30-2). (Repair) Replace the LUD2 detector. / Power Source-ON (After-work) Note Case 2 Trouble position/cause ‘Lift mechanism (motor, etc..) trouble’ Troubleshooting Guides (Check) ‘Check operations of the lift mechanism section (motor, etc.).’ (Repair) replace the e lift unit. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Bad connection between the PCU MAIN PWB and the lift unit. Troubleshooting Guides (Check) Check connection between the PCU MAIN PWB and the lift unit. (Repair) Repair or replace the connector and cables of the PCU MAIN PWB and the lift unit. / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: F3 32
- Description: Lift up trouble (Paper 3)
- Causes: Lifting is not completed (LUD3) is not turned ON) within the specified time after turning ON the lift motor.
- Troubleshooting Guides: Case 1 Trouble position/cause LUD3 detector trouble Troubleshooting Guides (Check) Check operation of the LUD3 detector (SIM 30-2). (Repair) Replace the LUD3 detector. / Power Source-ON (After-work) Note Case 2 Trouble position/cause ‘Lift mechanism (motor, etc.) trouble’ Troubleshooting Guides (Check) ‘Check operations of the lift mechanism section (motor, etc.).’ (Repair) replace the e lift unit. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Bad connection between the PCU MAIN PWB and the lift unit. Troubleshooting Guides (Check) Check connection between the PCU MAIN PWB and the lift unit. (Repair) Repair or replace the connector and cables of the PCU MAIN PWB and the lift unit. / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: F3 42
- Description: Lift up trouble (Paper 4)
- Causes: Lifting is not completed (LUD4) is not turned ON) within the specified time after turning ON the lift motor.
- Troubleshooting Guides: Case 1 Trouble position/cause LUD4 detector trouble Troubleshooting Guides (Check) Check operation of the LUD4 detector (SIM 30-2). (Repair) Replace the LUD4 detector. / Power Source-ON (After-work) Note Case 2 Trouble position/cause ‘Lift mechanism (motor, etc.) trouble’ Troubleshooting Guides (Check) ‘Check operations of the lift mechanism section (motor, etc.).’ (Repair) replace the e lift unit. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Bad connection between the PCU MAIN PWB and the lift unit. Troubleshooting Guides (Check) Check connection between the PCU MAIN PWB and the lift unit. (Repair) Repair or replace the connector and cables of the PCU MAIN PWB and the lift unit. / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: F9 0
- Description: ICU PWB-printer controller communication trouble (ICU detection)
- Causes: ‘Communication (protocol, data) error’
- Troubleshooting Guides: Case 1 Trouble position/cause Printer I/F PWB trouble Troubleshooting Guides (Check) Check the printer I/F PWB. (Repair) Replace the printer I/F PWB. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line between the printer controller and the ICU image PWB. Troubleshooting Guides (Check) Check the signal line between the printer controller and the ICU image PWB. (Repair) Repair or replace the cable and the connector between the printer controller and the ICU image PWB. / Power Source-ON (After-work) Note Case 3 Trouble position/cause ICU IMAGE PWB trouble Troubleshooting Guides (Check) (Repair) ICU IMAGE PWB replacement / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause Printer controller trouble Troubleshooting Guides (Check) Check the printer controller. (Repair) Repair or replace the printer controller. / Power Source-ON
- Code: H2 0
- Description: Fusing main temperature sensor (upper) (Thermistor) open / Fusing unit not-installed (THS1)
- Causes: Fusing main temperature sensor (upper) (Thermistor) output line open (A voltage of 4.6V or above is detected.) / The fusing unit is not installed.
- Troubleshooting Guides: Case 1 Trouble position/cause Fusing main temperature sensor (upper) (Thermistor) output line open trouble Troubleshooting Guides (Check) Bad connection between the fusing main temperature sensor (upper)(Thermistor) and the PCU SUB PWB (Repair) Check connection of the fusing main temperature sensor (upper)(Thermistor) and the PCU SUB PWB. / Power Source-ON (After-work) Repair or replace the harness and connector between the fusing main temperature sensor (upper)(Thermistor) and the PCU SUB PWB. Note Case 2 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON
- Code: H2 1
- Description: Fusing main temperature sensor (lower) (Thermistor) open / Fusing unit not-installed (THS2)
- Causes: Fusing main temperature sensor (lower) (Thermistor) output line open (A voltage of 4.6V or above is detected.) / The fusing unit is not installed.
- Troubleshooting Guides: Case 1 Trouble position/cause Fusing main temperature sensor (lower) (Thermistor) output line open trouble Troubleshooting Guides (Check) Bad connection between the fusing main temperature sensor (lower)(Thermistor) and the PCU SUB PWB (Repair) Check connection of the fusing main temperature sensor (lower)(Thermistor) and the PCU SUB PWB. / Power Source-ON (After-work) Repair or replace the harness and connector between the fusing main temperature sensor (lower)(Thermistor) and the PCU SUB PWB. Note Case 2 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON
- Code: H2 2
- Description: Fusing sub temperature sensor (upper) (Thermistor) open / Fusing unit not-installed (THS3)
- Causes: Fusing sub temperature sensor (upper) (Thermistor) output line open (A voltage of 4.6V or above is detected.) / The fusing unit is not installed.
- Troubleshooting Guides: Case 1 Trouble position/cause Fusing sub temperature sensor (upper) (Thermistor) output line open trouble Troubleshooting Guides (Check) Bad connection between the fusing sub temperature sensor (upper)(Thermistor) and the PCU SUB PWB (Repair) Check connection of the fusing sub temperature sensor (upper)(Thermistor) and the PCU SUB PWB. / Power Source-ON (After-work) Repair or replace the harness and connector between the fusing sub temperature sensor (upper)(Thermistor) and the PCU SUB PWB. Case 2 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON
- Code: H2 3
- Description: Fusing sub temperature sensor (lower) (Thermistor) open / Fusing unit not-installed (THS4)
- Causes: Fusing main temperature sensor (lower) (Thermistor) output line open (A voltage of 4.6V or above is detected.) / The fusing unit is not installed.
- Troubleshooting Guides: Case 1 Trouble position/cause Fusing main temperature sensor (lower) (Thermistor) output line open trouble Troubleshooting Guides (Check) Bad connection between the fusing main temperature sensor (lower)(Thermistor) and the PCU SUB PWB (Repair) Check connection of the fusing main temperature sensor (lower)(Thermistor) and the PCU SUB PWB. / Power Source-ON (After-work) Repair or replace the harness and connector between the fusing main temperature sensor (lower)(Thermistor) and the PCU SUB PWB. Note Case 2 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON
- Code: H3 0
- Description: Fusing section high temperature trouble (THS1)
- Causes: The fusing temperature rises above 220°C. (The temperature sensor (Thermistor) voltage of 0.85V or less is detected.)
- Troubleshooting Guides: Case 1 Trouble position/cause Temperature sensor (Thermistor) trouble Troubleshooting Guides (Check) Check for dirt on the temperature sensor (Thermistor). (Repair) Clean or replace the temperature sensor (Thermistor). / SIM 14 (After-work) Note Case 2 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / SIM 14 (After-work) Note Case 3 Trouble position/cause Heater lamp control PWB (AC SUB PWB) trouble Troubleshooting Guides (Check) Check the operation of the heater lamp. (SIM 5-2) (Repair) Replace the heater lamp control PWB (AC SUB PWB). / SIM 14
- Code: H3 1
- Description: Fusing section high temperature trouble (THS2)
- Causes: The fusing temperature rises above 220°C. (The temperature sensor (Thermistor) voltage of 0.85V or less is detected.)
- Troubleshooting Guides: Case 1 Trouble position/cause Temperature sensor (Thermistor) trouble Troubleshooting Guides (Check) Check for dirt on the temperature sensor (Thermistor). (Repair) Clean or replace the temperature sensor (Thermistor). / SIM 14 (After-work) Note Case 2 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / SIM 14 (After-work) Note Case 3 Trouble position/cause Heater lamp control PWB (AC SUB PWB) trouble Troubleshooting Guides (Check) Check the operation of the heater lamp. (SIM 5-2) (Repair) Replace the heater lamp control PWB (AC SUB PWB). / SIM 14
- Code: H3 2
- Description: Fusing section high temperature trouble (THS3)
- Causes: The fusing temperature rises above 220°C. (The temperature sensor (Thermistor) voltage of 0.85V or less is detected.)
- Troubleshooting Guides: Case 1 Trouble position/cause Temperature sensor (Thermistor) trouble Troubleshooting Guides (Check) Check for dirt on the temperature sensor (Thermistor). (Repair) Clean or replace the temperature sensor (Thermistor). / SIM 14 (After-work) Note Case 2 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / SIM 14 (After-work) Note Case 3 Trouble position/cause Heater lamp control PWB (AC SUB PWB) trouble Troubleshooting Guides (Check) Check the operation of the heater lamp. (SIM 5-2) (Repair) Replace the heater lamp control PWB (AC SUB PWB). / SIM 14
- Code: H3 3
- Description: Fusing section high temperature trouble (THS4)
- Causes: The fusing temperature rises above 220°C. (The temperature sensor (Thermistor) voltage of 0.85V or less is detected.)
- Troubleshooting Guides: Case 1 Trouble position/cause Temperature sensor (Thermistor) trouble Troubleshooting Guides (Check) Check for dirt on the temperature sensor (Thermistor). (Repair) Clean or replace the temperature sensor (Thermistor). / SIM 14 (After-work) Note Case 2 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / SIM 14 Case 3 Trouble position/cause Heater lamp control PWB (AC SUB PWB) trouble Troubleshooting Guides (Check) Check the operation of the heater lamp. (SIM 5-2) (Repair) Replace the heater lamp control PWB (AC SUB PWB). / SIM 14
- Code: H4 0
- Description: Fusing section (upper) low temperature trouble (HL1)
- Causes: The specified temperature is not reached within the specified time (5 min) after starting warm-up.
- Troubleshooting Guides: Case 1 Trouble position/cause Temperature sensor (Thermistor) trouble Troubleshooting Guides (Check) Check for dirt on the temperature sensor (Thermistor). (Repair) Clean or replace the temperature sensor (Thermistor). / SIM 14 (After-work) Note Case 2 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / SIM 14 (After-work) Note Case 3 Trouble position/cause Heater lamp control PWB (AC SUB PWB) trouble Troubleshooting Guides (Check) Check the operation of the heater lamp. (SIM 5-2) (Repair) Replace the heater lamp control PWB (AC SUB PWB). / SIM 14 (After-work) Note Case 4 Trouble position/cause AC main power PWB trouble Troubleshooting Guides (Check) Check the operation of the heater lamp. (SIM 5-2). (Repair) AC main power PWB replacement / SIM 14 (After-work) Note Case 5 Trouble position/cause Interlock switch (door) trouble Troubleshooting Guides (Check) Check the interlock switch (door). (Repair) Replace the interlock switch (door). / SIM 14 (After-work) Note Case 6 Trouble position/cause Thermostat operation or trouble Troubleshooting Guides (Check) Check the thermostat contact. (Repair) Reset or replace the thermostat. / SIM 14 (After-work) Note Case 7 Trouble position/cause Heater lamp trouble Troubleshooting Guides (Check) Check the operation of the heater lamp. (SIM5-2) (Repair) Replace the heater lamp. / SIM 14
- Code: H4 1
- Description: Fusing section (lower) low temperature trouble (HL2)
- Causes: The specified temperature is not reached within the specified time (5 min) after starting warm-up.
- Troubleshooting Guides: Case 1 Trouble position/cause Temperature sensor (Thermistor) trouble Troubleshooting Guides (Check) Check for dirt on the temperature sensor (Thermistor). (Repair) Clean or replace the temperature sensor (Thermistor). / SIM 14 (After-work) Note Case 2 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / SIM 14 (After-work) Note Case 3 Trouble position/cause Heater lamp control PWB (AC SUB PWB) trouble Troubleshooting Guides (Check) Check the operation of the heater lamp. (SIM 5-2) (Repair) Replace the heater lamp control PWB (AC SUB PWB). / SIM 14 (After-work) Note Case 4 Trouble position/cause AC main power PWB trouble Troubleshooting Guides (Check) Check the operation of the heater lamp. (SIM 5-2). (Repair) AC main power PWB replacement / SIM 14 (After-work) Note Case 5 Trouble position/cause Interlock switch (door) trouble Troubleshooting Guides (Check) Check the interlock switch (door). (Repair) Replace the interlock switch (door). / SIM 14 (After-work) Note Case 6 Trouble position/cause Thermostat operation or trouble Troubleshooting Guides (Check) Check the thermostat contact. (Repair) Reset or replace the thermostat. / SIM 14 (After-work) Note Case 7 Trouble position/cause Heater lamp trouble Troubleshooting Guides (Check) Check the operation of the heater lamp. (SIM5-2) (Repair) Replace the heater lamp. / SIM 14
- Code: H5 1
- Description: Paper jam in the fusing/paper exit section
- Causes: POD/DPID do not detect 3 sheets of paper continuously.
- Troubleshooting Guides: Case 1 Trouble position/cause Paper remaining in the fusing section Troubleshooting Guides (Check) Check for remaining paper. (Repair) Remove remaining paper. / SIM 14 (After-work) Note Case 2 Trouble position/cause POD/DPID detector trouble Troubleshooting Guides (Check) Check operations of POD/DPID detectors. (SIM30-1) (Repair) Replace the POD/DPID detectors. / SIM 14 (After-work) Note Case 3 Trouble position/cause Fusing unit installation trouble Troubleshooting Guides (Check) Check installation of the fusing unit. (Repair) Install the fusing unit properly. / SIM 14 Case 4 Trouble position/cause Fusing unit installation trouble Troubleshooting Guides (Check) (Repair) SIM 14 (After-work) Note Case 5 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / SIM 14 (After-work) Note Case 6 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / SIM 14 (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: H5 2
- Description: Paper jam in the fusing/paper exit sections (paper jam winding around the upper fusing roller) (Upper fusing roller temperature distribution abnormality)
- Causes: A difference is generated in the upper roller temperature distribution. (A difference between the detected outputs of the fusing main temperature sensor (THS1) and the sub temperature sensor (THS3) is greater than the specified level. (Winding of paper is detected.)
- Troubleshooting Guides: Case 1 Trouble position/cause Paper is winding around the fusing roller. Troubleshooting Guides (Check) Check for winding jam of paper around the fusing roller. (Repair) Remove paper winding around the fusing roller. / SIM 14 (After-work) Note Case 2 Trouble position/cause Temperature sensor (Thermistor) trouble Troubleshooting Guides (Check) Check for dirt on the temperature sensor (Thermistor). (Repair) Clean or replace the temperature sensor (Thermistor). / SIM 14 (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / SIM 14
- Code: H5 3
- Description: Paper jam in the fusing/paper exit sections (paper jam winding around the lower fusing roller) (Lower fusing roller temperature distribution abnormality)
- Causes: A difference is generated in the lower roller temperature distribution. (A difference between the detected outputs of the fusing main temperature sensor (THS2) and the sub temperature sensor (THS4) is greater than the specified level. (Winding of paper is detected.)
- Troubleshooting Guides: Case 1 Trouble position/cause Paper is winding around the fusing roller. Troubleshooting Guides (Check) Check for winding jam of paper around the fusing roller. (Repair) Remove paper winding around the fusing roller. / SIM 14 Case 2 Trouble position/cause Temperature sensor (Thermistor) trouble Troubleshooting Guides (Check) Check for dirt on the temperature sensor (Thermistor). (Repair) Clean or replace the temperature sensor (Thermistor). / SIM 14 (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / SIM 14
- Code: H6 0
- Description: Fusing oil empty (Oil sensor trouble)
- Causes: Fussing oil empty is detected.
- Troubleshooting Guides: Case 1 Trouble position/cause Insufficient remaining quantity of fusing oil Troubleshooting Guides (Check) Check the remaining quantity of fusing oil. (Repair) Supply fusing oil. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Fusing oil sensor trouble Troubleshooting Guides (Check) Check operation of the fusing oil sensor. (SIM30-1) (Repair) Replace the fusing oil sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB fusing oil sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON
- Code: H7 0
- Description: AC input voltage (HLV) trouble
- Causes: An AC input voltage of 0.5V or less or 4.0Vor above is detected more than 50 times repeatedly in sampling. (Sampling interval: 10msec)
- Troubleshooting Guides: Case 1 Trouble position/cause DC SUB power PWB trouble Troubleshooting Guides (Check) Check the DC SUB power PWB HLV signal circuit. (Repair) DC SUB power PWB replacement / Power Source-ON (After-work) Note Case 2 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the PCU SUB PWB HLV signal circuit. (Repair) PCU SUB PWB replacement / Power Source-ON
- Code: L1 0
- Description: Scanner feed trouble
- Causes: Scanner feed is not completed within the specified time. (The scanner home position sensor (MHPS) does not turn OFF within the specified time after outputting the scanner motor ON (feeding start) signal.)
- Troubleshooting Guides: Case 1 Trouble position/cause Scanner home position sensor (MHPS) trouble Troubleshooting Guides (Check) Check the scanner home position sensor (MHPS) operation. (SIM 1-1/1-2) (Repair) Replace the scanner home position sensor (MHPS). / Power Source-ON (After-work) Note Case 2 Trouble position/cause Scanner motor trouble / Scanner motor control PWB trouble Troubleshooting Guides (Check) Check the scanner motor. / Check the scanner motor control PWB. (SIM 1-1) (Repair) Replace the scanner motor. / Replace the scanner motor control PWB. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Scanner mechanism section trouble Troubleshooting Guides (Check) Check the scanner mechanism section. (Repair) ‘Repair the scanner mechanism section (scanner driver wire, drive pulley, etc.).’ / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: L3 0
- Description: Scanner return trouble
- Causes: Scanner feed is not completed within the specified time. (The scanner home position sensor (MHPS) does not turn OFF within the specified time after outputting the scanner motor ON (feeding start) signal.)
- Troubleshooting Guides: Case 1 Trouble position/cause Scanner home position sensor (MHPS) trouble Troubleshooting Guides (Check) Check the scanner home position sensor (MHPS) operation. (SIM 1-1/1-2) (Repair) Replace the scanner home position sensor (MHPS). / Power Source-ON (After-work) Note Case 2 Trouble position/cause Scanner motor trouble / Scanner motor control PWB trouble Troubleshooting Guides (Check) Check the scanner motor. / Check the scanner motor control PWB. (SIM 1-1) (Repair) Replace the scanner motor. / Replace the scanner motor control PWB. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Scanner mechanism section trouble Troubleshooting Guides (Check) Check the scanner mechanism section. (Repair) ‘Repair the scanner mechanism section (scanner driver wire, drive pulley, etc.).’ / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: L4 1
- Description: Paper feed motor trouble
- Causes: The motor lock signal is detected for 1.5sec or more during rotation of the paper feed motor.
- Troubleshooting Guides: Case 1 Trouble position/cause Paper feed motor trouble Troubleshooting Guides (Check) Check the paper feed motor operation. (SIM 6-1) (Repair) Replace the paper feed motor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 3 Trouble position/cause Paper feed/transport mechanism section trouble. Troubleshooting Guides (Check) Check the loads in the paper feed/transport mechanism section. (Repair) Repair or replace parts in the paper feed/transport mechanism section. / Power Source-ON
- Code: L4 3
- Description: Fusing motor trouble
- Causes: The encoder pulse is not detected for 50ms or more when the fusing motor is ON.
- Troubleshooting Guides: Case 1 Trouble position/cause Fusing motor trouble Troubleshooting Guides (Check) Check the fusing motor operation.(SIM 6-1) (Repair) Replace the fusing motor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 3 Trouble position/cause Fusing mechanism section trouble Troubleshooting Guides (Check) Check the loads of the fusing mechanism section. (Repair) Repair or replace the parts in the fusing mechanism section. / Power Source-ON
- Code: L4 4
- Description: Developing motor trouble (BLACK)
- Causes: The motor lock signal is detected for 1.5sec or more when the developing motor is ON.
- Troubleshooting Guides: Case 1 Trouble position/cause Developing motor trouble Troubleshooting Guides (Check) Check the developing motor operation (SIM 25-1). (Repair) Replace the developing motor. / Power Source-ON Case 2 Trouble position/cause Developing mechanism section trouble Troubleshooting Guides (Check) Check the loads of the developing mechanism section. (Repair) Repair or replace the parts in the developing mechanism section. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: L4 5
- Description: Developing motor trouble (COLOR)
- Causes: The motor lock signal is detected for 1.5sec or more when the developing motor is ON.
- Troubleshooting Guides: Case 1 Trouble position/cause Developing motor trouble Troubleshooting Guides (Check) Check the developing motor operation (SIM 25-1). (Repair) Replace the developing motor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Developing mechanism section trouble Troubleshooting Guides (Check) Check the loads of the developing mechanism section. (Repair) Repair or replace the parts in the developing mechanism section. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause Developing motor power line trouble Troubleshooting Guides (Check) Check the fuse (F707). (Repair) Replace the fuse (F707). / Power Source-ON
- Code: L4 6
- Description: Transfer belt lift trouble
- Causes: The transfer unit home position sensor (BLLD) ON/OFF is not detected (kept ON or OFF) when the transfer unit is lifted up and down.
- Troubleshooting Guides: Case 1 Trouble position/cause Transfer belt lift motor trouble Troubleshooting Guides (Check) Check the transfer belt lift motor. (SIM 6-1) (Repair) Replace the transfer belt lift motor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Transfer unit home position sensor (BLUD) trouble Troubleshooting Guides (Check) Check the transfer unit home position sensor (BLUD) operation. (SIM 30-1) (Repair) Replace the transfer unit home position sensor (BLUD). / Power Source-ON Case 3 Trouble position/cause Transfer unit lift mechanism section trouble Troubleshooting Guides (Check) Check the transfer unit lift mechanism section. (Repair) Repair the transfer unit lift mechanism or replace the parts. / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) PCU SUB PWB transfer lift motor circuit check. (Repair) PCU SUB PWB replacement / Power Source-ON
- Code: L6 10
- Description: Scanner (writing) motor lock detection (BLACK)
- Causes: Scanner (writing) unit (LSU) polygon motor lock signal detection trouble (The lock signal is not detected for 10 sec after turning on the polygon motor.)
- Troubleshooting Guides: Case 1 Trouble position/cause Scanner (writing) unit (LSU) trouble Troubleshooting Guides (Check) Scanner (writing) unit (LSU) operation check (SIM 61-1) (Repair) Replace the scanner (writing) unit (LSU). / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10 Note Case 2 Trouble position/cause ICU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) ICUMAIN PWB replacement / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.)
- Code: L6 11
- Description: Scanner (writing) motor lock detection (CYAN)
- Causes: Scanner (writing) unit (LSU) polygon motor lock signal detection trouble (The lock signal is not detected for 10 sec after turning on the polygon motor.)
- Troubleshooting Guides: Case 1 Trouble position/cause Scanner (writing) unit (LSU) trouble Troubleshooting Guides (Check) Scanner (writing) unit (LSU) operation check (SIM 61-1) (Repair) Replace the scanner (writing) unit (LSU). / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10 Note Case 2 Trouble position/cause ICU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) ICUMAIN PWB replacement / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.)
- Code: L6 12
- Description: Scanner (writing) motor lock detection (MAGENTA)
- Causes: Scanner (writing) unit (LSU) polygon motor lock signal detection trouble (The lock signal is not detected for 10 sec after turning on the polygon motor.)
- Troubleshooting Guides: Case 1 Trouble position/cause Scanner (writing) unit (LSU) trouble Troubleshooting Guides (Check) Scanner (writing) unit (LSU) operation check (SIM 61-1) (Repair) Replace the scanner (writing) unit (LSU). / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10 Note Case 2 Trouble position/cause ICU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) ICUMAIN PWB replacement / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.)
- Code: L6 13
- Description: Scanner (writing) motor lock detection (YELLOW)
- Causes: Scanner (writing) unit (LSU) polygon motor lock signal detection trouble (The lock signal is not detected for 10 sec after turning on the polygon motor.)
- Troubleshooting Guides: Case 1 Trouble position/cause Scanner (writing) unit (LSU) trouble Troubleshooting Guides (Check) Scanner (writing) unit (LSU) operation check (SIM 61-1) (Repair) Replace the scanner (writing) unit (LSU). / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10 Note Case 2 Trouble position/cause ICU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) ICUMAIN PWB replacement / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.)
- Code: L8 1
- Description: Power full wave signal (FWS) trouble
- Causes: ‘The power full wave signal (FWS) is not detected. / AC power waveform distortion, noise’
- Troubleshooting Guides: Case 1 Trouble position/cause Fusing oil collection pipe section short connector trouble Troubleshooting Guides (Check) Check the fusing oil collection pipe section short connector. (Repair) Replace the fusing oil collection pipe section short connector. / Power Source-ON (After-work) Note Case 2 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the power full wave signal (FWS) circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) Check the power full wave signal (FWS) circuit. (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause DC SUB power PWB trouble Troubleshooting Guides (Check) Check the power full wave signal (FWS) circuit. (Repair) DC SUB power PWB replacement / Power Source-ON
- Code: L8 2
- Description: Power full wave signal (FWS) width trouble
- Causes: ‘The power full wave signal (FWS) is not detected. / AC power waveform distortion, noise (When the detection cycle is judged as 69Hz or more or 42.5Hz or less.)’
- Troubleshooting Guides: Case 1 Trouble position/cause Fusing oil collection pipe section short connector trouble Troubleshooting Guides (Check) Check the fusing oil collection pipe section short connector. (Repair) Replace the fusing oil collection pipe section short connector. / Power Source-ON (After-work) Note Case 2 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the power full wave signal (FWS) circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) Check the power full wave signal (FWS) circuit. (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) Check the power full wave signal (FWS) circuit. (Repair) PCU SUB PWB replacement / Power Source-ON
- Code: PF 0
- Description: RIC copy inhibit signal reception
- Causes: The RIC copy inhibit command is received through RIC I/F from the host.
- Troubleshooting Guides: Case 1 Trouble position/cause The copy inhibit command is received from the host. Troubleshooting Guides (Check) (Repair) Use SIM 27-1 to ignore the copy inhibit command. / SIM 17 (After-work) Note Case 2 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) RIC I/F circuit check (Repair) Replace the PCU MAIN PWB. / SIM 17 (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: U0 0
- Description: Operation control PWB – PCU MAIN PWB communication trouble (OPE/PCU detection)
- Causes: ‘Communication (protocol, data) error’
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection of the signal line between the PCU MAIN PWB and the operation control PWB Troubleshooting Guides (Check) Check the signal line between the PCU MAIN PWB and the operation control PWB. (Repair) Repair or replace the cable and the connector between the PCU MAIN PWB and the operation control PWB. / Power Source-ON Case 2 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 3 Trouble position/cause Operation control PWB trouble Troubleshooting Guides (Check) (Repair) Operation control PWB replacement / Power Source-ON
- Code: U0 80
- Description: PCU MAIN PWB – PCU SUB PWB communication trouble (PCU detection)
- Causes: ‘Communication (protocol, data) error’
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection of the signal line between the PCUMAIN PWB and the PCU SUB PWB. Troubleshooting Guides (Check) Check connection of the signal line between the PCU MAIN PWB and the PCU SUB PWB. (Repair) Repair or replace the cable and the connector of the PCU MAIN PWB and the PCU SUB PWB. / Power Source-ON (After-work) Note Case 2 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 3 Trouble position/cause PCU SUB PWB trouble Troubleshooting Guides (Check) (Repair) PCU SUB PWB replacement / Power Source-ON
- Code: U2 0
- Description: EEPROM read/write error (PCU MAIN PWB)
- Causes: EEPROM read/write error
- Troubleshooting Guides: Case 1 Trouble position/cause EEPROM trouble Troubleshooting Guides (Check) (Repair) Replace the EEPROM. / SIM 16 (After-work) Note Case 2 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / SIM 16 (After-work) Re-enter the set values and the adjustment values.
- Code: U2 11
- Description: Counter data (EEPROM) check sum error (PCU MAIN PWB)
- Causes: Counter data area check sum error
- Troubleshooting Guides: Case 1 Trouble position/cause EEPROM trouble Troubleshooting Guides (Check) (Repair) Replace the EEPROM. / SIM 16 (After-work) Note Case 2 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / SIM 16 (After-work) Re-enter the set values and the adjustment values.
- Code: U2 12
- Description: Setup/adjustment value data (EEPROM) check sum error (PCU MAIN PWB)
- Causes: Setup/adjustment data area check sum error
- Troubleshooting Guides: Case 1 Trouble position/cause EEPROM trouble Troubleshooting Guides (Check) (Repair) Replace the EEPROM. / SIM 16 (After-work) Note Case 2 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / SIM 16 (After-work) Re-enter the set values and the adjustment values.
- Code: U2 20
- Description: EEPROM read/write error (ICU MAIN PWB)
- Causes: EEPROM read/write error
- Troubleshooting Guides: Case 1 Trouble position/cause EEPROM trouble Troubleshooting Guides (Check) (Repair) Replace the EEPROM. / SIM 16 (After-work) Note Case 2 Trouble position/cause ICU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) ICU MAIN PWB replacement / SIM 16 (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.)
- Code: U2 21
- Description: Counter (EEPROM) check sum error (ICU MAIN PWB)
- Causes: Counter data area check sum error
- Troubleshooting Guides: Case 1 Trouble position/cause EEPROM trouble Troubleshooting Guides (Check) (Repair) Replace the EEPROM. / SIM 16 (After-work) Note Case 2 Trouble position/cause ICU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) ICU MAIN PWB replacement / SIM 16 (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.)
- Code: U2 22
- Description: Setup, adjustment value (EEPROM) check sum error (ICU MAIN PWB)
- Causes: Setup/adjustment data area check sum error
- Troubleshooting Guides: Case 1 Trouble position/cause EEPROM trouble Troubleshooting Guides (Check) (Repair) Replace the EEPROM. / SIM 16 (After-work) Note Case 2 Trouble position/cause ICU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) ICUMAIN PWB replacement / SIM 16 (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.)
- Code: U2 30
- Description: Manufacturing No. data (ICU MAIN PWB / PCU MAIN PWB) discrepancy
- Causes: The serial No. data stored in the ICU MAIN PWB (EEPROM) and that in the PCU MAIN PWB (EEPROM) do not coincide.
- Troubleshooting Guides: Case 1 Trouble position/cause ‘When replacing the ICU MAIN PWB or the PCU MAIN PWB, the serial No. data is not entered.’ Troubleshooting Guides (Check) (Repair) Enter the correct serial No. data to the ICU MAIN PWB and the PCU MAIN PWB (EEPROM) (SIM 29-1/2). / SIM 16
- Code: U4 0
- Description: PCU MAIN PWB – ADU communication trouble
- Causes: Communication test error in warm-up
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection of the signal line between the PCU MAIN PWB and the ADU control PWB. Troubleshooting Guides (Check) Check connection of the signal line between the PCU MAIN PWB and the ADU control PWB. (Repair) Repair or replace the cable and the connector between the PCU MAIN PWB and the ADU control PWB. / Power Source-ON Case 2 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 3 Trouble position/cause ADU control PWB trouble Troubleshooting Guides (Check) (Repair) ADU control PWB replacement / Power Source-ON
- Code: U4 12
- Description: ADU transport motor trouble
- Causes: ‘The motor rotation sensor (RE) signal cycle becomes 50msec or more after 1sec from turning ON the ADU transport motor. / The motor rotation sensor (RE) signal is detected more than 100 times during 100msec after 5sec from turning OFF the ADU transport motor.’
- Troubleshooting Guides: Case 1 Trouble position/cause Duplex transport motor trouble Troubleshooting Guides (Check) Check the duplex transport motor operation. (SIM9-1/2/4) (Repair) Replace the duplex transport motor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Duplex transport motor rotation sensor (DMRE) trouble Troubleshooting Guides (Check) Duplex transport motor rotation sensor (DMRE) operation check (SIM 9-1/2/4) (Repair) Replace the duplex transport motor rotation sensor (DMRE). / Power Source-ON (After-work) Note Case 3 Trouble position/cause Duplex mechanism section trouble Troubleshooting Guides (Check) Duplex mechanism section operation check (SIM9-1/2/4) (Repair) Repair or replace the duplex mechanism section. / Power Source-ON (After-work) Note Case 4 Trouble position/cause ADU control PWB trouble Troubleshooting Guides (Check) (Repair) ADU control PWB replacement / Power Source-ON
- Code: U4 2
- Description: ADU alignment plate operation trouble
- Causes: The home position sensor (DPHPS) detects the home position sensor for 1sec or more after starting separating operation of the alignment plate from the home position. / The home position is not detected within 5sec after starting returning operation to the home position.
- Troubleshooting Guides: Case 1 Trouble position/cause Alignment home position sensor (DPHPS) trouble Troubleshooting Guides (Check) Check the alignment home position sensor (DPHPS) operation. (SIM9-1/2/4) (Repair) Replace the alignment home position sensor (DPHPS). / Power Source-ON (After-work) Note Case 2 Trouble position/cause Duplex alignment motor trouble. Troubleshooting Guides (Check) Check the duplex alignment motor operation. (SIM9-1/2/4) (Repair) Replace the duplex alignment motor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Duplex mechanism section trouble Troubleshooting Guides (Check) Check the duplex mechanism section operation. (SIM9-1/2/4) (Repair) Repair or replace the duplex mechanism section. / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 5 Trouble position/cause ADU control PWB trouble Troubleshooting Guides (Check) (Repair) ADU control PWB replacement / Power Source-ON
- Code: U5 0
- Description: PCU MAIN PWB – RADF communication trouble
- Causes: Communication test error in warm-up
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection of the signal line between the PCU MAIN PWB and the RADF control PWB. Troubleshooting Guides (Check) Check connection of the signal line between the PCU MAIN PWB and the RADF control PWB. (Repair) Repair or replace the cable and the connector between the PCU MAIN PWB and the RADF control PWB. / Power Source-ON (After-work) Note Case 2 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 3 Trouble position/cause RADF control PWB trouble Troubleshooting Guides (Check) (Repair) RADF control PWB replacement / Power Source-ON
- Code: U5 1
- Description: RADF resist sensor trouble
- Causes: RADF resist sensor detection trouble
- Troubleshooting Guides: Case 1 Trouble position/cause RADF resist sensor trouble Troubleshooting Guides (Check) Check operation of the RADF resist sensor. (SIM 2-2) (Repair) Replace the RADF resist sensor. / Power Source-ON Case 2 Trouble position/cause RADF control PWB trouble Troubleshooting Guides (Check) (Repair) RADF control PWB replacement / Power Source-ON
- Code: U5 11
- Description: RADF paper feed motor trouble
- Causes: RADF paper feed motor lock / Motor rpm abnormality / Overcurrent to the motor
- Troubleshooting Guides: Case 1 Trouble position/cause RADF paper feed motor trouble Troubleshooting Guides (Check) Check the RADF paper feed motor operation. (SIM2-1/2/3) (Repair) Replace the RADF paper feed motor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause RADF control PWB trouble Troubleshooting Guides (Check) (Repair) RADF control PWB replacement / Power Source-ON
- Code: U5 2
- Description: RADF exit sensor trouble
- Causes: RADF paper exit sensor detection trouble
- Troubleshooting Guides: Case 1 Trouble position/cause RADF paper exit sensor trouble Troubleshooting Guides (Check) Check the RADF paper exit sensor operation. (SIM 2-2) (Repair) Replace the RADF paper exit sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause RADF control PWB trouble Troubleshooting Guides (Check) (Repair) RADF control PWB replacement / Power Source-ON
- Code: U5 3
- Description: RADF timing sensor trouble
- Causes: RADF timing sensor detection trouble
- Troubleshooting Guides: Case 1 Trouble position/cause RADF timing sensor trouble Troubleshooting Guides (Check) Check the RADF timing sensor operation. (SIM 2-2) (Repair) Replace the RADF timing sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause RADF control PWB trouble Troubleshooting Guides (Check) (Repair) RADF control PWB replacement / Power Source-ON
- Code: U6 20
- Description: PCU MAIN PWB- Large capacity tray (LCC) communication trouble
- Causes: Communication test error in warm-up
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection of the signal line between the PCU MAIN PWB and the large capacity tray (LCC) control PWB Troubleshooting Guides (Check) Check connection of the signal line between the PCU MAIN PWB and the large capacity tray (LCC) control PWB. (Repair) Repair or replace the cable and the connector between the PCU MAIN PWB and the large capacity tray (LCC) control PWB. / Power Source-ON (After-work) Note Case 2 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 3 Trouble position/cause Large capacity tray (LCC) control PWB trouble Troubleshooting Guides (Check) (Repair) Large capacity tray (LCC) control PWB replacement / Power Source-ON
- Code: U6 21
- Description: Large capacity tray (LCC) transport motor trouble
- Causes: The rotation sensor output signal does not change when the transport motor is turned ON. / The rotation sensor output signal changes after turning OFF the transport motor.
- Troubleshooting Guides: Case 1 Trouble position/cause Transport motor trouble Troubleshooting Guides (Check) Check the transport motor operation. (SIM 4-3) (Repair) Replace the transport motor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Transport mechanism section trouble Troubleshooting Guides (Check) Check the transport mechanism section operation. (SIM 4-3) (Repair) Repair or replace the transport mechanism section. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Large capacity tray (LCC) control PWB trouble Troubleshooting Guides (Check) (Repair) Large capacity tray (LCC) control PWB replacement / Power Source-ON
- Code: U6 22
- Description: Large capacity tray (LCC) 24V power trouble
- Causes: DC24V power is not supplied to the large capacity tray (LCC).
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection between the DC MAIN power PWB and the large capacity tray (LCC) Troubleshooting Guides (Check) ‘Check connection between the fuse (F708), the DC MAIN power PWB and the large capacity tray (LCC).’ (Repair) Replace the fuse (F708). Repair or replace the wire and the connector between the DC MAIN power PWB and the large capacity tray (LCC) control PWB. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Large capacity tray (LCC) control PWB trouble Troubleshooting Guides (Check) (Repair) Large capacity tray (LCC) control PWB replacement / Power Source-ON
- Code: U6 9
- Description: Large capacity tray (LCC) lift motor trouble
- Causes: The rotation sensor output signal does not change when the lift motor is turned ON. / The rotation sensor output signal changes after turning OFF the lift motor.
- Troubleshooting Guides: Case 1 Trouble position/cause Lift motor rotation sensor trouble Troubleshooting Guides (Check) Check the lift motor rotation sensor operation. (Repair) Replace the lift motor rotation sensor. / SIM 15 (After-work) Note Case 2 Trouble position/cause ‘Lift mechanism (motor, etc.) trouble’ Troubleshooting Guides (Check) ‘Check the lift mechanism (motor, etc.) operation. (SIM4-3)’ (Repair) Replace the lift unit (lift motor). / SIM 15 (After-work) Note Case 3 Trouble position/cause Large capacity tray (LCC) control PWB trouble Troubleshooting Guides (Check) (Repair) Replace the large capacity tray (LCC) control PWB. / SIM 15 (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / SIM 15 (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: U7 0
- Description: RIC communication trouble
- Causes: Communication test error in warm-up
- Troubleshooting Guides: Case 1 Trouble position/cause Bad connection of the signal line between the PCU MAIN PWB and the RIC I/F. Troubleshooting Guides (Check) Check connection of the signal line between the PCU MAIN PWB and the RIC I/F. (Repair) Repair or replace the cable and the connector between the PCU MAIN PWB and the RIC I/F / Power Source-ON (After-work) Note Case 2 Trouble position/cause PCU MAIN PWB trouble Troubleshooting Guides (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
- Code: UC 0
- Description: ICU SCAN PWB -CPT PWB communication trouble
- Causes: ICU SCAN PWB / CPT PWB
- Troubleshooting Guides: Case 1 Trouble position/cause CPT PWB trouble Troubleshooting Guides (Check) CPT PWB connector check (Repair) CPT PWB replacement / Power Source-ON (After-work) Note Case 2 Trouble position/cause ICU SCAN PWB trouble Troubleshooting Guides (Check) ICU SCAN PWB connector check (Repair) ICU SCAN PWB replacement / Power Source-ON
- Code: UC 1
- Description: CPT board program trouble
- Causes: CPT PWB program hung up
- Troubleshooting Guides: Case 1 Trouble position/cause CPT PWB trouble Troubleshooting Guides (Check) ‘If the trouble cannot be canceled by turning ON/OFF the power repeatedly, replace the CPT PWB..’ (Repair) CPT PWB replacement / Power Source-ON
- Code: UC 2
- Description: CPT board ASIC trouble
- Causes: Gate array abnormality on the CPT PWB
- Troubleshooting Guides: Case 1 Trouble position/cause CPT PWB trouble Troubleshooting Guides (Check) ‘If the trouble cannot be canceled by turning ON/OFF the power repeatedly, replace the CPT PWB..’ (Repair) CPT PWB replacement / Power Source-ON
- Code: UC 3
- Description: CPT board ROM trouble
- Causes: CPT PWB ROM abnormality
- Troubleshooting Guides: Case 1 Trouble position/cause CPT PWB trouble Troubleshooting Guides (Check) (Repair) CPT PWB replacement / Power Source-ON
- Code: UC 4
- Description: CPT board RAM trouble
- Causes: CPT PWB RAM abnormality
- Troubleshooting Guides: Case 1 Trouble position/cause CPT PWB trouble Troubleshooting Guides (Check) (Repair) CPT PWB replacement / Power Source-ON
- Code: UC 5
- Description: CPT board model code data trouble
- Causes: The model code data sent from the CPU PWB to the ICU SCAN PWB is abnormal.
- Troubleshooting Guides: Case 1 Trouble position/cause CPT PWB trouble Troubleshooting Guides (Check) (Repair) CPT PWB replacement / Power Source-ON
Epson L850 Adjustment Program
– OS Support: only Windows Operating System.
– Because Adjprog.exe gets Hardware ID info => Antivirus will misunderstand Adjprog.exe is the virus ==> you need to disable antivirus before extract and run Epson L850 Adjustment Program or add to exclusion folder
– Limitation: Unlimited using on only 1 Computer.
– Epson L850 AdjProg or Epson L850 Adjustment Program or Epson L850 Adj Program, is a middleware developed by third-party software to supply for Epson L850 printer, making printer continuous printing without error.
– Epson L850 Adjustment Program is featured with clearing the waste ink counter, ultra-deep clean to clean the printhead, adjust the smoothness of the printhead, adjust the motor headers, and fix the errors: no printing, lack of colour printing, colour blur, prints with horizontal and vertical stripes…
Epson L850 Adjustment Functions:
– Bi-D Adjustment
– USB ID Input
– Initial Ink Charge
– Deep Cleaning the Print Head
– Reset Waste Ink Pad Counter
– Head ID Setting
– EEPROM initial setting
– Top margin Adjustment
Using Epson L850 Adjustment Program
– Choose printer model and usb connection
– Choose Particular Adjustment Mode
– Choose Waste Ink Pad Counter
– Read Waste Ink Pad Counter
– Reset Waste Ink Pad Counter
Active Epson L850 Adjustment Program
– Run Adjprog.exe, Copy L850 Hardware ID, send it to admin email : [email protected] to get serial key and then active Epson L850 Adjustment Program.
– More information about Epson L850 Adjustment Program: https://shop.nguyendangnam.com/product/epson-l850-adjustment-program/
– Download Canon driver and firmware in specific model: https://dnasofts.com/canon-cp730-printer-driver-firmware-and-user-manual-free-download/
– Download Epson driver and firmware in specific model: https://dnasofts.com/download-epson-lq-200-driver-firmware-and-manuals/
Source:
https://chiplessprinter.com
https://dnasofts.com
https://shop.nguyendangnam.com/
https://nguyendangnam.me/
https://chiplessprinter.com/reset-epson-waste-ink-pad-counter.html
Contact us to get support with Sharp ARC280 Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/