Sharp ARB453PT Printer with list Error Codes and Epson BX-305FW+ Adjustment Program
– Printer model: Sharp ARB453PT
– Error codes on Sharp ARB453PT with details instruction fixing:
- Code: A0-30
- Description: Machine configuration error
- Causes: FAX PWB is broken
Wireless LAN PWB is not connected properly
Wireless LAN PWB is broken
RSPF/SPF is not connected properly
RSPF/SPF is broken - Troubleshooting Guides: Check connection of FAX PWB
Replace FAX modem PWB
Check connection of Wireless LAN PWB
Replace Wireless LAN PWB
Check connection of RSPF/SPF
Replace RSPF/SPF
- Code: E7-01
- Description: Image data error
- Causes: Image data transfer error in MFPC PWB
MFPC PWB trouble - Troubleshooting Guides: Check connection state of MFPC PWB connector, harness
Replace MFPC PWB
- Code: E7-20
- Description: LSU laser detection error
- Causes: Reduced laser power, lighting error, laser diode trouble
LSU connector, harness connection trouble
LSU unit trouble
MFPC PWB trouble - Troubleshooting Guides: SIM61-1 to execute
Check connection state of LSU connector, harness
Replace LSU unit
Replace MFPC PWB
- Code: E7-21
- Description: LSU laser deterioration error
- Causes: Reduced laser power, lighting error, laser diode trouble
LSU connector, harness connection trouble
LSU unit trouble
MFPC PWB trouble - Troubleshooting Guides: SIM61-1 to execute
Check connection state of LSU connector, harness
Replace LSU unit
Replace MFPC PWB
- Code: E7-38
- Description: Quatro chip AD adjustment error
- Causes: The voltage on MFPC PWB is not stable
The parts on the MFPC PWB are not soldered properly - Troubleshooting Guides: Replace the MFPC PWB.
- Code: E7-90
- Description: Communication error between ICU and PCU
- Causes: MFPC PWB trouble
- Troubleshooting Guides: Check connection state of MFPC PWB connector, harness
Replace MFPC PWB
- Code: E7-91
- Description: Decode error (FAX received image data)
- Causes: Image compression data corruption
HDD trouble
mSATA eMMC trouble
MFPC PWB trouble
FAX PWB trouble - Troubleshooting Guides: SIM60-1 to execute
Replace HDD
Replace mSATA eMMC
Replace MFPC PWB
Replace FAX PWB
- Code: E7-93
- Description: Decode error
- Causes: Image compression data corruption
HDD trouble
MFPC PWB trouble - Troubleshooting Guides: SIM60-1 to execute
Replace HDD
Replace MFPC PWB
- Code: EE-EC
- Description: Automatic toner density adjustment error (Sampling abnormal)
- Causes: Toner density sensor trouble.
Charging voltage / developing voltage trouble.
Toner density trouble.
Developing unit trouble.
MFPC PWB trouble. - Troubleshooting Guides: Replace Developing unit.
Replace MFPC PWB.
- Code: EE-EL
- Description: Automatic toner density adjustment error (Over toner)
- Causes: Toner density sensor trouble.
Charging voltage / developing voltage trouble.
Toner density trouble.
Developing unit trouble.
MFPC PWB trouble. - Troubleshooting Guides: Replace Developing unit.
Replace MFPC PWB.
- Code: EE-EU
- Description: Automatic toner density adjustment error (Under toner)
- Causes: Toner density sensor trouble.
Charging voltage / developing voltage trouble.
Toner density trouble.
Developing unit trouble.
MFPC PWB trouble. - Troubleshooting Guides: Replace Developing unit.
Replace MFPC PWB.
- Code: F2-22
- Description: Discharge lamp trouble
- Causes: Connector, harness connection trouble
Discharge lamp trouble
MFPC PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace discharge lamp
Replace MFPC PWB
- Code: F2-39
- Description: Temperature and humidity sensor trouble (temperature)
- Causes: Connector, harness connection trouble
Sensor (TH/HUD) trouble
MFPC PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace sensor (TH/HUD)
Replace MFPC PWB
- Code: F2-40
- Description: Toner concentration sensor trouble
- Causes: Connector, harness connection trouble
DV unit trouble
Sensor (TCS) trouble
MFPC PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace DV unit
Replace MFPC PWB
- Code: F2-58
- Description: Temperature and humidity sensor trouble (humidity)
- Causes: Connector, harness connection trouble
Sensor (TH/HUD) trouble
MFPC PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace sensor (TH/HUD)
Replace MFPC PWB
- Code: F2-64
- Description: Black toner supply trouble
- Causes: Connector, harness connection trouble
DV unit trouble
Toner cartridge trouble
Toner transport pipe section trouble
Sensor (TCS) trouble
Motor (TNM) trouble
MFPC PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace DV unit
Replace toner cartridge
Check transport pipe section
Replace motor (TNM)
Replace MFPC PWB
- Code: F2-70
- Description: Mismatched black toner cartridge
- Causes: Improper toner cartridge is inserted
Toner cartridge trouble - Troubleshooting Guides: Replace toner cartridge
- Code: F2-74
- Description: Black CRUM error
- Causes: Connector, harness connection trouble
Toner cartridge trouble
MFPC PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace toner cartridge
Replace MFPC PWB
– Sharp ARB453PT printer Error Codes and quick guide on repairing:
- Code: F2-78
- Description: Image density sensor error
- Causes: Connector, harness connection trouble
Sensor (PCS) dirt or trouble
MFPC PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Clean sensor (PCS) or replace
Replace MFPC PWB
- Code: H2-00
- Description: Thermistor open trouble (TH_UM_AD2)
- Causes: Thermistor connector, harness connection trouble
Fusing section connector connection trouble
Thermistor trouble
MFPC PWB trouble
AC PWB trouble
Fusing unit not installed - Troubleshooting Guides: SIM44-14 to execute
Check connection state of thermistor connector, harness
Check connection state of fusing section connector
Replace thermistor
Replace MFPC PWB
Replace AC PWB trouble
Check fusing unit installed
- Code: H2-02
- Description: Thermistor open trouble (TH_US)
- Causes: Thermistor connector, harness connection trouble
Fusing section connector connection trouble
Thermistor trouble
MFPC PWB trouble
AC PWB trouble
Fusing unit not installed - Troubleshooting Guides: SIM44-14 to execute
Check connection state of thermistor connector, harness
Check connection state of fusing section connector
Replace thermistor
Replace MFPC PWB
Replace AC PWB trouble
Check fusing unit installed
- Code: H2-03
- Description: Thermistor open trouble (TH_UM_CS)
- Causes: Thermistor connector, harness connection trouble
Fusing section connector connection trouble
Thermistor trouble
MFPC PWB trouble
Fusing unit not installed
Fusing unit trouble - Troubleshooting Guides: SIM44-14 to execute
Check connection state of thermistor connector, harness
Check connection state of fusing section connector
Replace thermistor
Replace MFPC PWB
Check fusing unit installed
Replace fusing unit
- Code: H2-06
- Description: Thermistor open trouble (TH_US2)
- Causes: Thermistor connector, harness connection trouble
Fusing section connector connection trouble
Thermistor trouble
MFPC PWB trouble
AC PWB trouble
Fusing unit not installed - Troubleshooting Guides: SIM44-14 to execute
Check connection state of thermistor connector, harness
Check connection state of fusing section connector
Replace thermistor
Replace MFPC PWB
Replace AC PWB trouble
Check fusing unit installed
- Code: H3-00
- Description: Fuser high temperature trouble (TH_UM_CS)
- Causes: Thermistor connector, harness connection trouble
Thermistor trouble
MFPC PWB trouble
AC PWB trouble - Troubleshooting Guides: SIM44-14 to execute
SIM5-2 to execute
Check connection state of thermistor connector, harness
Replace thermistor
Replace MFPC PWB
Replace AC PWB
SIM14 to cancel
- Code: H3-02
- Description: Fuser high temperature trouble (TH_US)
- Causes: Thermistor connector, harness connection trouble
Thermistor trouble
MFPC PWB trouble
AC PWB trouble - Troubleshooting Guides: SIM44-14 to execute
SIM5-2 to execute
Check connection state of thermistor connector, harness
Replace thermistor
Replace MFPC PWB
Replace AC PWB
SIM14 to cancel
- Code: H4-00
- Description: Fuser low temperature trouble (TH_UM)
- Causes: Thermistor connector, harness connection trouble
Thermistor trouble
Heater lamp trouble
MFPC PWB trouble
Thermostat trouble
AC PWB trouble - Troubleshooting Guides: SIM44-14 to execute
SIM5-2 to execute
Check connection state of thermistor connector, harness
Replace thermistor
Replace heater lamp
Replace MFPC PWB
Replace thermostat
Replace AC PWB
SIM14 to cancel
- Code: H4-02
- Description: Fuser low temperature trouble (TH_US)
- Causes: Thermistor connector, harness connection trouble
Thermistor trouble
Heater lamp trouble
MFPC PWB trouble
Thermostat trouble
AC PWB trouble - Troubleshooting Guides: SIM44-14 to execute
SIM5-2 to execute
Check connection state of thermistor connector, harness
Replace thermistor
Replace heater lamp
Replace MFPC PWB
Replace thermostat
Replace AC PWB
SIM14 to cancel
- Code: H4-30
- Description: Fuser differential input trouble (TH_UM)
- Causes: Thermistor connector, harness connection trouble
Thermistor trouble
Heater lamp trouble
MFPC PWB trouble - Troubleshooting Guides: SIM5-2 to execute
Check connection state of thermistor connector, harness
Replace thermistor
Replace heater lamp
Replace MFPC PWB
SIM14 to cancel
- Code: H5-01
- Description: 5 times continuous POD1 not reach jam
- Causes: Fusing jam was not cancel completely (jam paper remains)
Fusing unit installation trouble
Fusing unit, drive section trouble
Sensor (POD1) connector, harness connection trouble
Sensor (POD1) trouble - Troubleshooting Guides: Check fusing unit installed
Check fusing drive section
Check connection state of sensor (POD1) connector, harness
Replace sensor (POD1)
Replace fusing unit
SIM14 to cancel
- Code: H7-10
- Description: Recovery error from fuser low temperature (TH_UM_CS)
- Causes: Thermistor connector, harness connection trouble
Thermistor trouble
Heater lamp trouble
MFPC PWB trouble
Thermostat trouble
AC PWB trouble - Troubleshooting Guides: SIM5-2 to execute
Check connection state of thermistor connector, harness
Replace thermistor
Replace heater lamp
Replace MFPC PWB
Replace thermostat
Replace AC PWB
- Code: H7-12
- Description: Recovery error from fuser low temperature (TH_US)
- Causes: Thermistor connector, harness connection trouble
Thermistor trouble
Heater lamp trouble
MFPC PWB trouble
Thermostat trouble
AC PWB trouble - Troubleshooting Guides: SIM5-2 to execute
Check connection state of thermistor connector, harness
Replace thermistor
Replace heater lamp
Replace MFPC PWB
Replace thermostat
Replace AC PWB
- Code: L4-01
- Description: Main motor lock trouble
- Causes: Connector, harness connection trouble
Motor trouble(MM)
MFPC PWB trouble - Troubleshooting Guides: SIM6-1 to execute
Check connection state of connector, harness
Replace motor (MM)
Replace MFPC PWB
- Code: L4-14
- Description: Toner cartridge motor lock trouble
- Causes: Motor trouble(TNM)
Toner motor drive detect sensor trouble (TM_COUNT)
Connector, harness connection trouble
MFPC PWB trouble - Troubleshooting Guides: SIM10-1 to execute
SIM10-4 to execute
Check connection state of connector, harness
Replace motor (TNM)
Replace toner motor drive detect sensor
Replace MFPC PWB
Replace detect sensor
- Code: L4-17
- Description: Drum motor lock trouble
- Causes: Motor trouble(DM)
Connector, harness connection trouble
MFPC PWB trouble - Troubleshooting Guides: SIM25-1 to execute
Check connection state of connector, harness
Replace motor (DM)
Replace MFPC PWB
- Code: L4-31
- Description: Paper delivery cooling fan trouble
- Causes: Motor trouble(POFM)
Connector, harness connection trouble - Troubleshooting Guides: SIM6-2 to execute
Check connection state of connector, harness
Replace fan (POFM)
- Code: L4-32
- Description: Power supply unit fan trouble
- Causes: Motor trouble(PSFM)
Connector, harness connection trouble - Troubleshooting Guides: SIM6-2 to execute
Check connection state of connector, harness
Replace fan (PSFM)
- Code: L4-35
- Description: Fuser cooling fan trouble
- Causes: Motor trouble(FUFM)
Connector, harness connection trouble - Troubleshooting Guides: SIM6-2 to execute
Check connection state of connector, harness
Replace fan (FUFM)
- Code: L4-39
- Description: Machine cooling fan trouble
- Causes: Motor trouble(VFM)
Connector, harness connection trouble - Troubleshooting Guides: SIM6-2 to execute
Check connection state of connector, harness
Replace motor (VFM)
- Code: L4-43
- Description: Paper cooling fan trouble
- Causes: Motor trouble(POFM2)
Connector, harness connection trouble
MFPC PWB trouble - Troubleshooting Guides: SIM6-2 to execute
Check connection state of connector, harness
Replace motor (POFM2)
Replace MFPC PWB
- Code: L6-10
- Description: Polygon motor trouble
- Causes: Connector, harness connection trouble
Motor (PGM) trouble
MFPC PWB trouble - Troubleshooting Guides: SIM6-1 to execute
Check connection state of connector, harness
Replace MFPC PWB
Replace LSU unit
- Code: L8-01
- Description: Full wave signal detection error
- Causes: Connector, harness connection trouble
Power supply unit trouble
MFPC PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace power supply unit
Replace MFPC PWB
- Code: L8-02
- Description: Abnormal full wave signal error
- Causes: Connector, harness connection trouble
Power supply unit trouble
MFPC PWB trouble - Troubleshooting Guides: Check connection state of connector, harness
Replace power supply unit
Replace MFPC PWB
- Code: U1-01
- Description: Battery trouble
- Causes: Battery life
Battery circuit trouble - Troubleshooting Guides: Check battery voltage is 2.5V or above
Replace battery
- Code: U2-00
- Description: MFP EEPROM read/write error
- Causes: MFPC PWB EEPROM trouble.
EEPROM socket contact trouble.
MFPC PWB trouble.
Strong external noises. - Troubleshooting Guides: Replace the MFPC PWB EEPROM.
Replace the MFPC PWB.
Check the power environment.
- Code: U2-05
- Description: Account data error (HDD-MFP SRAM)
- Causes: EEPROM is broken
The device access error/connection error of EEPROM by the noise - Troubleshooting Guides: Cancel the error by SIM16
- Code: U2-06
- Description: Memory content Error (Flash ROM sector management error) detection eMMC Read Error Detection
- Causes: Flash ROM data error/Program ROM data error
Flash ROM device contact trouble/Program device trouble
Device access trouble by the noise - Troubleshooting Guides: Export the backup data using SIM56-2/3, restore the data, import again.
Replace the MFPC PWB.
- Code: U2-11
- Description: MFP EEPROM counter check sum error
- Causes: EEPROM device trouble
EEPROM device contact trouble
Device access trouble by the noise - Troubleshooting Guides: Cancel the error by SIM16
- Code: U2-91
- Description: PCU EEPROM check sum error
- Causes: EEPROM socket contact trouble
Replace EEPROM
Replace MFPC PWB - Troubleshooting Guides: Check contact of EEPROM socket
Replace EEPROM
Replace MFPC PWB
SIM16 to cancel
- Code: U6-00
- Description: MFPC PWB – Paper feed desk (paper feed tray 2) communication error
- Causes: Malfunction due to noises
Connector, harness connection trouble
Desk control PWB trouble
MFPC PWB trouble - Troubleshooting Guides: Power OFF/ON to cancel
Check connection state of connector, harness
Replace desk control PWB
Replace MFPC PWB
- Code: U6-01
- Description: Desk paper feed tray 1 lift trouble
- Causes: Connector, harness connection trouble
Sensor (D1LUD) trouble
Desk tray1 control PWB trouble
Lift unit trouble - Troubleshooting Guides: SIM4-2 to execute
Check connection state of connector, harness
Replace sensor (D1LUD)
Replace desk tray1 control PWB
Replace lift unit
- Code: U6-11
- Description: Desk paper feed tray 1 transport trouble
- Causes: Connector, harness connection trouble
Motor (D1PFM) trouble
Desk tray1 control PWB trouble - Troubleshooting Guides: SIM4-3 to execute
Check connection state of connector, harness
Replace motor (D1PFM)
Replace desk tray1 control PWB
- Code: U6-50
- Description: Desk – Main unit combination trouble
- Causes: Improper combination between main machine and desk
Desk control PWB trouble - Troubleshooting Guides: Install desk which is proper for main machine
Replace desk control PWB
- Code: U6-56
- Description: Desk paper feed tray 1 firmware error
- Causes: Firmware version is inconsistency
- Troubleshooting Guides: SIM49-1 to execute
- Code: U9-00
- Description: Communication trouble between the controller and OPU
- Causes: OPU connector connection trouble
Harness trouble between OPU PWB and MFPC PWB
Break connector pin of OPU PWB - Troubleshooting Guides: Check connector connection and harness of OPU
PWB and MFPC PWB
Replace OPU PWB or MFPC PWB
Check ground point
Power off/on
- Code: U9-81
- Description: OPU communication trouble (parity)
- Causes: Harness trouble between OPU PWB and MFPC PWB
- Troubleshooting Guides: Check connector connection and harness of OPU
PWB and MFPC PWB
Replace OPU PWB or MFPC PWB
Check ground point
Power off/on
- Code: U9-82
- Description: OPU communication trouble (overrun)
- Causes: Harness trouble between OPU PWB and MFPC PWB
- Troubleshooting Guides: Check connector connection and harness of OPU
PWB and MFPC PWB
Replace OPU PWB or MFPC PWB
Check ground point
Power off/on
- Code: U9-84
- Description: OPU communication trouble (flaming)
- Causes: Harness trouble between OPU PWB and MFPC PWB
- Troubleshooting Guides: Check connector connection and harness of OPU
PWB and MFPC PWB
Replace OPU PWB or MFPC PWB
Check ground point
Power off/on
- Code: U9-88
- Description: OPU communication trouble (time-out)
- Causes: Command size error from MFPC to OPU
- Troubleshooting Guides: Replace OPU PWB or MFPC PWB
Power off/on
- Code: U9-99
- Description: OPU language error
- Causes: Command size error from MFPC to OPU
- Troubleshooting Guides: Replace OPU PWB or MFPC PWB
Power off/on
Epson BX-305FW+ Adjustment Program
– OS Support: only Windows Operating System.
– Because Adjprog.exe gets Hardware ID info => Antivirus will misunderstand Adjprog.exe is the virus ==> you need to disable antivirus before extract and run Epson BX-305FW+ Adjustment Program or add to exclusion folder
– Limitation: Unlimited using on only 1 Computer.
– Epson BX-305FW+ AdjProg or Epson BX-305FW+ Adjustment Program or Epson BX-305FW+ Adj Program, is a middleware developed by third-party software to supply for Epson BX-305FW+ printer, making printer continuous printing without error.
– Epson BX-305FW+ Adjustment Program is featured with clearing the waste ink counter, ultra-deep clean to clean the printhead, adjust the smoothness of the printhead, adjust the motor headers, and fix the errors: no printing, lack of colour printing, colour blur, prints with horizontal and vertical stripes…
Epson BX-305FW+ Adjustment Functions:
– Bi-D Adjustment
– USB ID Input
– Initial Ink Charge
– Deep Cleaning the Print Head
– Reset Waste Ink Pad Counter
– Head ID Setting
– EEPROM initial setting
– Top margin Adjustment
Using Epson BX-305FW+ Adjustment Program
– Choose printer model and usb connection
– Choose Particular Adjustment Mode
– Choose Waste Ink Pad Counter
– Read Waste Ink Pad Counter
– Reset Waste Ink Pad Counter
Active Epson BX-305FW+ Adjustment Program
– Run Adjprog.exe, Copy BX-305FW+ Hardware ID, send it to admin email : [email protected] to get serial key and then active Epson BX-305FW+ Adjustment Program.
– More information about Epson BX-305FW+ Adjustment Program: https://shop.nguyendangnam.com/product/epson-bx-305fw+-adjustment-program/
– Download Canon driver and firmware in specific model: https://dnasofts.com/canon-ts6120-printer-driver-firmware-and-user-manual-free-download/
– Download Epson driver and firmware in specific model: https://dnasofts.com/download-epson-fx-850+-driver-firmware-and-manuals/
Source:
https://chiplessprinter.com
https://dnasofts.com
https://shop.nguyendangnam.com/
https://nguyendangnam.me/
https://chiplessprinter.com/reset-epson-waste-ink-pad-counter.html
Contact us to get support with Sharp ARB453PT Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/