Sharp AL1622 Printer with list Error Codes and Epson Artisan-830 Adjustment Program
– Printer model: Sharp AL1622
– Error codes on Sharp AL1622 with details instruction fixing:
- Code: E1-00
- Description: Communication trouble between MCU and E-Sort.
Communication setup error, framing, parity, protocol error - Causes: E-Sort PWB connector disconnection E-Sort PWB MCU PWB harness failure E-Sort Motherboard connector pin breakage. E-Sort PWB ROM defect, data failure
- Code: E1-10
- Description: E-Sort PWB trouble
Communication trouble between MCU and E-Sort - Causes: E-Sort PWB connector disconnection E-Sort PWB MCU PWB harness failure E-Sort Motherboard connector pin breakage. E-Sort PWB ROM defect, data failure
- Code: E1-11
- Description: E-Sort PWB ASIC error
E-Sort PWB ASIC abnormality - Causes: An ASIC abnormality is detected in the E-Sort PWB. Control circuit hung up due to noises ASIC peripheral circuit error
- Code: E1-12
- Description: E-Sort PWB CODEC error
A CODEC error is detected in the E-Sort PWB. Control circuit hung up due to noises CODEC peripheral circuit error - Causes: Replace the E-Sort PWB. Check grounding of the machine.
- Code: E1-13
- Description: E-Sort PWB Flash ROM error
E-Sort PWB Flash ROM abnormality - Causes: A Flash ROM abnormality is detected in the E-Sort PWB. Control circuit hung up due to noises Flash ROM peripheral circuit error
- Code: E1-14
- Description: E-Sort PWB Work RAM error
E-Sort PWB Work RAM abnormality - Causes: A Work RAM abnormality is detected in the E-Sort PWB. Control circuit hung up due to noises RAM peripheral circuit error
- Code: E1-15
- Description: E-Sort PWB Page Memory error
E-Sort PWB Page Memory abnormality - Causes: A Page Memory abnormality is detected in the E-Sort PWB. Control circuit hung up due to noises Page Memory peripheral circuit error
- Code: E1-16
- Description: E-Sort PWB SIMM error
E-Sort PWB SIMM abnormality - Causes: A SIMM abnormality is detected in the E-Sort PWB. Control circuit hung up due to noises SIMM peripheral circuit error
- Code: E1-17
- Description: E-Sort PWB image rotating RAM error
E-Sort PWB image rotating RAM abnormality - Causes: An image rotating RAM abnormality is detected in the E-Sort PWB. Control circuit hung up due to noises Image rotating RAM peripheral circuit error
- Code: E1-80
- Description: E-Sort PWB communication trouble (protocol)
Communication trouble between MCU and printer PWB (Protocol error) - Causes: E-Sort PWB connector disconnection E-Sort PWB MCU PWB harness failure E-Sort Motherboard connector pin breakage. E-Sort PWB ROM defect, data failure
- Code: E1-81
- Description: E-Sort PWB communication trouble (Parity)
Communication trouble between MCU and printer E-Sort (Parity error) - Causes: E-Sort PWB connector disconnection E-Sort PWB MCU PWB harness failure E-Sort Motherboard connector pin breakage. E-Sort PWB ROM defect, data failure
- Code: E1-82
- Description: E-Sort PWB communication trouble (Overrun)
Communication trouble between MCU and E-Sort PWB (Overrun error) - Causes: E-Sort PWB connector disconnection E-Sort PWB MCU PWB harness failure E-Sort Motherboard connector pin breakage. E-Sort PWB ROM defect, data failure
- Code: E1-84
- Description: E-Sort PWB communication trouble (Framing)
Communication trouble between MCU and E-Sort PWB (Framing error) - Causes: E-Sort PWB connector disconnection E-Sort PWB MCU PWB harness failure E-Sort Motherboard connector pin breakage. E-Sort PWB ROM defect, data failure
- Code: E1-88
- Description: E-Sort PWB communication trouble (Time-out)
Communication trouble between MCU and E-Sort PWB (Time-out error) - Causes: E-Sort PWB connector disconnection E-Sort PWB and MCU PWB harness failure E-Sort Motherboard connector pin breakage. E-Sort PWB ROM defect, data failure
- Code: E7-03
- Description: LSU trouble
After the polygon motor becomes active, BD signal (HSYNC) from the LSU is not detected at the specified times (41 +- 10 times within 20msec). - Causes: LSU connector disconnection or LSU’s inside harness disconnection or breakage Polygon motor rotation abnormality Improper positioning of the laser home position sensor in the LSU. Laser power voltage failure Laser emitting diode abnormality MCU PWB abnormality
- Code: E7-04
- Description: CCD white level trouble
CCD white reference level which is read during the copy lamp lighting is abnormal. - Causes: Flat cable installation failure to CCD unit Dirt on the mirror, lens, and reference white plate Copy lamp lighting failure CCD unit installation failure CCD unit abnormality MCU PWB abnormality
- Code: E7-05
- Description: CCD black level trouble
CCD black level which is read while the copy lamp is off is abnormal. - Causes: Flat cable installation failure CCD unit abnormality MCU PWB abnormality
- Code: F1-06
- Description: Shifter motor trouble
The home position is not detected within 1 sec after shifter motor drive. - Causes: The shifter home position sensor is defective. The shifter motor is defective. The shifter motor periphery circuit is defective. The condition of the MCU PWB JP4 is wrong. The assembly of the shifter motor unit is improper.
– Sharp AL1622 printer Error Codes and quick guide on repairing:
- Code: F2-04
- Description: CRUM data read trouble
Communication error between CRUM PWB and MCU PWB - Causes: CRUM PWB data error MCU PWB error MCU PWB EEPROM error Disconnection between CRUM (toner cartridge) and MCU PWB
- Code: F5-02
- Description: Copy lamp error
Copy lamp voltage detection error - Causes: Power unit trouble Copy lamp trouble Inverter trouble MCU PWB trouble
- Code: F9-00
- Description: Communication trouble between MCU and printer PWB (MCU detection)
Communication establishment error, framing error, parity error, protocol error - Causes: Bad connection of printer PWB connector Defective harness between printer PWB and MCU PWB. Motherboard connector pin breakage Printer PWB ROM error, data error
- Code: F9-10
- Description: Printer PWB trouble
Communication trouble between MCU and printer PWB - Causes: Bad connection of printer PWB connector Defective harness between printer PWB and MCU PWB. Motherboard connector pin breakage Printer PWB ROM error, data error
- Code: F9-80
- Description: Printer PWB communication trouble (Protocol)
Communication trouble between MCU and printer PWB (Protocol error) - Causes: Bad connection of printer PWB connector Defective harness between printer PWB and MCU PWB. Motherboard connector pin breakage Printer PWB ROM error, data error
- Code: F9-81
- Description: Printer PWB communication trouble (Parity)
Communication trouble between MCU and printer PWB (Parity error) - Causes: Printer PWB connector disconnection Printer PWB MCU PWB harness failure Printer PWB mother board connector pin breakage. Printer PWB ROM defect, data failure
- Code: F9-82
- Description: Printer PWB communication trouble (Overrun)
Communication trouble between MCU and printeu PWB (Overrun error) - Causes: Printer PWB connector disconnection Printer PWB MCU PWB harness failure Printer PWB mother board connector pin breakage. Printer PWB ROM defect, data failure
- Code: F9-84
- Description: Printer PWB communication trouble (Framing)
Communication trouble between MCU and printer PWB (Framing error) - Causes: Printer PWB connector disconnection Printer PWB MCU PWB harness failure Printer PWB mother board connector pin breakage. Printer PWB ROM defect, data failure
- Code: F9-88
- Description: Printer PWB communication trouble (Time-out)
Communication trouble between MCU and printeu PWB (Time-out error) - Causes: Printer PWB connector disconnection Printer PWB MCU PWB harness failure Printer PWB mother board connector pin breakage. Printer PWB ROM defect, data failure
- Code: H2-00
- Description: Thermistor open detection
Fusing thermistor open - Causes: Thermistor defect MCU PWB defect Fusing section connector contact failure Power supply failure Fusing unit not installed
- Code: H3-00
- Description: Heat roller abnormally high temperature
Fusing temperature of 220 ~ 240°C. - Causes: Thermistor defect MCU PWB defect Fusing connector connection failure Power supply failure
- Code: H4-00
- Description: Heat roller abnormally low temperature
When the temperature does not reach 155°C within 55 sec after turning on the power, or when it falls under 145°C during printing, or when it falls under 100°C during pre-heating - Causes: Thermistor failure Heater lamp failure MCU PWB failure Thermostat failure Power supply failure Interlock switch failure
- Code: L1-00
- Description: Mirror base feed trouble
The mirror home position (MHPS) does not turn off though the feed operation is completed during mirror initial operation after turning on the power. The mirror home position (MHPS) does not turn off during shading operation. The mirror home position (MHPS) does not turn on when the mirror base is returned for the specified time after copy feed is started and SPF scanning position shift is performed. - Causes: Mirror unit defect Mirror home position sensor defect MCU PWB defect Scanner wire disconnection
- Code: L3-00
- Description: Mirror base return trouble
The mirror home position (MHPS) does not turn on though the mirror base returning is completed during mirror initial operation after turning on the power. The mirror home position does not turn on when the mirror is returned to the home position during shading. The mirror home position (MHPS) does not turn on when the mirror base returning is completed for the specified time (about 6 sec) after copy return start. - Causes: Mirror unit Mirror home position sensor defect MCU PWB defect Scanner wire disconnection
- Code: L4-01
- Description: Main motor lock
The main motor encoder pulse is not detected for 400msec. - Causes: Main motor defect Harness disconnection between the MCU PWB and the main motor. Control circuit failure
- Code: L4-10
- Description: Job separator motor trouble
When the home is not detected within 2.5 sec after the job separator tray starts to move upwards. - Causes: The job separator upper limit detection sensor is defective. The job separator motor is defective. The job separator motor periphery circuit is defective. The condition of the MCU PWB JP5 is wrong.
- Code: L6-10
- Description: Polygon motor lock
The lock signal (the specified rotation speed signal) is not supplied within the specified time (about 6 sec) after starting the polygon motor rotation. - Causes: LSU connector disconnection or harness disconnection in the LSU.
- Code: L8-01
- Description: Zero cross pulse (FW) trouble
Zero cross pulse width is shifted by 55Hz +-10% or more. - Causes: MCU PWB defect Power supply unit breakdown
- Code: U2-04
- Description: EEPROM serial communication error
Error in communication with EEPROM - Causes: EEPROM failure Installation of uninitialized EEPROM MCU PWB EERPOM access circuit faiure
- Code: U2-11
- Description: Counter check sum error
Counter check sum value stored in the EEPROM is abnormal. - Causes: EEPROM failure Control circuit hung up by noises MCU PWB EEPROM access circuit defect
- Code: U2-12
- Description: Adjustment value check sum error (EEPROM)
Adjustment value data area check sum error - Causes: EEPROM failure Control circuit hung up by noises MCU PWB EEPROM access circuit failure
- Code: U2-40
- Description: CRUM communication error
Toner cartridge CRUM data read error - Causes: A toner cartridge of a different destination is installed. EEPROM trouble Check the destination setup. Toner cartridge CRUM PWB trouble MCU PWB trouble CRUM connector disconnection
- Code: U3-29
- Description: Mirror base home position error
Home position is not detected when starting mirror base shift. - Causes: Mirror unit defect Mirror home position sensor defect MCU PWB decfect Scanner wire disconnection
- Code: U9-00
- Description: Communication trouble between MCU and OPE (OPE detection)
Communication setup error, framing, parity, protocol error - Causes: Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
- Code: U9-80
- Description: Operation control PWB communication trouble (Protocol)
Communication trouble between MCU and the operation control PWB (Protocol error) - Causes: Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
- Code: U9-81
- Description: Operation control PWB communication trouble (Parity)
Communication trouble between MCU and the operation control PWB (Parity error) - Causes: Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
- Code: U9-82
- Description: Operation control PWB communication trouble (Overrun)
Communication trouble between MCU and the operation control PWB (Overrun error) - Causes: Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
- Code: U9-84
- Description: Operation control PWB communication trouble (Framing)
Communication trouble between MCU and the operation control PWB (Framing error) - Causes: Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
- Code: U9-88
- Description: Operation control PWB communication trouble (Time-out)
Communication trouble between MCU and the operation PWB (Time-out error) - Causes: Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
- Code: U95
- Description: Operation control PWB communication error
Communication error between the operation control PWB and the MCU PWB (Detected by the OPE-PWB) - Causes: Disconnection or reverse connection of the flat cable between the Operation control PWB and the MCU PWB. Operation control PWB trouble MCU PWB trouble Connector trouble of the operation control PWB and the MCU PWB
- Code: U99
- Description: Operation control PWB communication error
Communication error between the operation control PWB and the MCU PWB (Detected by the OPE-PWB) - Causes: Disconnection or reverse connection of the flat cable between the Operation control PWB and the MCU PWB. Operation control PWB trouble MCU PWB trouble Connector trouble of the operation control PWB and the MCU PWB
Epson Artisan-830 Adjustment Program
– OS Support: only Windows Operating System.
– Because Adjprog.exe gets Hardware ID info => Antivirus will misunderstand Adjprog.exe is the virus ==> you need to disable antivirus before extract and run Epson Artisan-830 Adjustment Program or add to exclusion folder
– Limitation: Unlimited using on only 1 Computer.
– Epson Artisan-830 AdjProg or Epson Artisan-830 Adjustment Program or Epson Artisan-830 Adj Program, is a middleware developed by third-party software to supply for Epson Artisan-830 printer, making printer continuous printing without error.
– Epson Artisan-830 Adjustment Program is featured with clearing the waste ink counter, ultra-deep clean to clean the printhead, adjust the smoothness of the printhead, adjust the motor headers, and fix the errors: no printing, lack of colour printing, colour blur, prints with horizontal and vertical stripes…
Epson Artisan-830 Adjustment Functions:
– Bi-D Adjustment
– USB ID Input
– Initial Ink Charge
– Deep Cleaning the Print Head
– Reset Waste Ink Pad Counter
– Head ID Setting
– EEPROM initial setting
– Top margin Adjustment
Using Epson Artisan-830 Adjustment Program
– Choose printer model and usb connection
– Choose Particular Adjustment Mode
– Choose Waste Ink Pad Counter
– Read Waste Ink Pad Counter
– Reset Waste Ink Pad Counter
Active Epson Artisan-830 Adjustment Program
– Run Adjprog.exe, Copy Artisan-830 Hardware ID, send it to admin email : [email protected] to get serial key and then active Epson Artisan-830 Adjustment Program.
– More information about Epson Artisan-830 Adjustment Program: https://shop.nguyendangnam.com/product/epson-artisan-830-adjustment-program/
– Download Canon driver and firmware in specific model: https://dnasofts.com/canon-ip3500-printer-driver-firmware-and-user-manual-free-download/
– Download Epson driver and firmware in specific model: https://dnasofts.com/download-epson-xp-970-driver-firmware-and-manuals/
Source:
https://chiplessprinter.com
https://dnasofts.com
https://shop.nguyendangnam.com/
https://nguyendangnam.me/
https://chiplessprinter.com/reset-epson-waste-ink-pad-counter.html
Contact us to get support with Sharp AL1622 Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/