Repair Canon MF9150c Printer Error Codes Canon Servie Tool
– Printer model: Canon MF9150c
– Error codes on Canon MF9150c model and its description:
– Canon MF9150c printer Error Codes and quick guide to troubleshooting:
- Code: E000-0000
- Description: Error in start-up of fixing assembly
- Causes: When 1 sec passed after energization of the heater, the detected temperature of the main thermistor is not 5 deg C or more (0 deg C at power on). Cause Disconnection of main thermistor, disconnection of fixing heater, error in DC controller PCB.
- Solutions: – Check of the connector of the low-voltage power supply PCB – Replacement of fixing sleeve unit – Replacement of DC controller PCB
- Code: E001-0000
- Description: Error in overheating of fixing assembly
- Causes: The status where the detected temperature of the main thermistor is 225 deg C (approx. 0.84V equivalent) or more is detected for 0.5 continuous sec or more. Cause Error in main thermistor, error in DC controller PCB.
- Solutions: – Check of the connector of the low-voltage power supply PCB – Replacement of fixing sleeve unit – Replacement of DC controller PCB
- Code: E001-0001
- Description: Error in overheating of fixing assembly
- Causes: The status where the detected temperature of the sub thermistor is 245 deg C (approx. 2.12V equivalent) or more is detected for 0.5 continuous sec or more. Cause Error in sub thermistor, error in DC controller PCB.
- Solutions: – Check of the connector of the low-voltage power supply PCB – Replacement of fixing sleeve unit – Replacement of DC controller PCB
- Code: E003-0000
- Description: Error in abnormally low temperature of fixing assembly
- Causes: The status where the detected temperature of the main thermistor is 100 deg C (approx. 2.60V equivalent) or less is detected for 0.5 continuous sec or more. Cause Error in low-voltage power supply PCB, disconnection of main thermistor, error in DC controller PCB.
- Solutions: – Replacement of low-voltage power supply PCB – Replacement of fixing sleeve unit – Replacement of DC controller PCB
- Code: E003-0001
- Description: Error in abnormally low temperature of fixing assembly
- Causes: The status where the detected temperature of the sub thermistor is less than 100 deg C (approx. 0.38V equivalent) is detected 0.5 continuous sec or more after energization of the heater. Cause Error in sub thermistor, error in DC controller PCB.
- Solutions: – Check of the connector of the low-voltage power supply PCB – Replacement of fixing sleeve unit – Replacement of DC controller PCB
- Code: E004-0000
- Description: Error in fixing power supply drive circuit
- Causes: Cannot detect the zero cross signal for the specified period or more. Cause Error in fixing control circuit block.
- Solutions: – Replacement of low-voltage power supply PCB
- Code: E012-0000
- Description: Error in activation of motor
- Causes: When 3.5 sec passed after activation of ETB motor, the cycle of ETB motor speed detection signal does not become its specified value. Cause Error in ETB motor, error in DC controller PCB.
- Solutions: – Replacement of ETB motor – Replacement of DC controller PCB
- Code: E012-0001
- Description: Error in activation of motor
- Causes: After ETB motor speed detection signal became the specified value of the cycle, it exceeds the specified cycle for 2 continuous sec or more. Cause Error in ETB motor, error in DC controller PCB.
- Solutions: – Replacement of ETB motor – Replacement of DC controller PCB
- Code: E012-0002
- Description: Error in activation of motor
- Causes: When 2.5 sec passed after activation of the yellow drum motor, the cycle of drum motor speed detection signal does not become its specified value. Cause Error in drum motor, error in DC controller PCB.
- Solutions: – Replacement of drum motor – Replacement of DC controller PCB
- Code: E012-0003
- Description: Error in activation of motor
- Causes: After the yellow drum motor speed detection signal became the specified value of the cycle, it exceeds the specified cycle for 2 continuous sec or more. Cause Error in drum motor, error in DC controller PCB.
- Solutions: – Replacement of drum motor – Replacement of DC controller PCB
- Code: E012-0004
- Description: Error in activation of motor
- Causes: When 2.5 sec passed after activation of the magenta drum motor, the cycle of drum motor speed detection signal does not become its specified value. Cause Error in drum motor, error in DC controller PCB.
- Solutions: – Replacement of drum motor – Replacement of DC controller PCB
- Code: E012-0005
- Description: Error in activation of motor
- Causes: After the magenta drum motor speed detection signal became the specified value of the cycle, it exceeds the specified cycle for 2 continuous sec or more. Cause Error in drum motor, error in DC controller PCB.
- Solutions: – Replacement of drum motor – Replacement of DC controller PCB
- Code: E012-0006
- Description: Error in activation of motor
- Causes: When 2.5 sec passed after activation of the cyan drum motor, the cycle of the drum motor speed detection signal does not become its specified value. Cause Error in drum motor, error in DC controller PCB.
- Solutions: – Replacement of drum motor – Replacement of DC controller PCB
- Code: E012-0007
- Description: Error in activation of motor
- Causes: After the cyan drum motor speed detection signal became the specified value of the cycle, it exceeds the specified cycle for 2 continuous sec or more. Cause Error in drum motor, error in DC controller PCB.
- Solutions: – Replacement of drum motor – Replacement of DC controller PCB
- Code: E012-0008
- Description: Error in activation of motor
- Causes: When 2.5 sec passed after activation of the black drum motor, the cycle of the drum motor speed detection signal does not become its specified value. Cause Error in drum motor, error in DC controller PCB.
- Solutions: – Replacement of drum motor – Replacement of DC controller PCB
- Code: E012-0009
- Description: Error in activation of motor
- Causes: After the black drum motor speed detection signal became the specified value of the cycle, it exceeds the specified cycle for 2 continuous sec or more. Cause Error in drum motor, error in DC controller PCB.
- Solutions: – Replacement of drum motor – Replacement of DC controller PCB
- Code: E014-0000
- Description: Error in activation of fixing motor
- Causes: When 2.5 sec passed after activation of fixing motor, the cycle of the fixing motor speed detection signal does not become its specified value. Cause Error in fixing motor, error in DC controller PCB.
- Solutions: – Replacement of fixing motor – Replacement of DC controller PCB
- Code: E014-0001
- Description: Error in activation of fixing motor
- Causes: After the fixing motor speed detection signal became the specified value of the cycle, it exceeds the specified cycle for 2 continuous sec or more. Cause Error in fixing motor, error in DC controller PCB.
- Solutions: – Replacement of fixing motor – Replacement of DC controller PCB
- Code: E015-0000
- Description: Failure in developing disengagement
- Causes: Developing cylinder disengagement mechanism does not function correctly. Cause Developing disengagement mechanism fault, developing disengagement solenoid fault, developing disengagement sensor fault, DC controller PCB fault.
- Solutions: Check the developing disengagement mechanism. Replace developing disengagement solenoid. Replace developing disengagement sensor. Replace DC controller PCB.
- Code: E020-0000
- Description: Error in density sensor
- Causes: Cannot receive enough light when detecting image density. Cause Dirt on density sensor, error in density sensor, error in DC controller PCB, error in toner cartridge.
- Solutions: – Replacement of ETB unit – Error in high-voltage joint (Check high-voltage joint for each color, and each joint to high-voltage PCB) – Replacement of DC controller – Replacement of toner cartridge
- Code: E024-0000
- Description: Toner level sensor failure
- Causes: Failure output from the toner level sensor (Yellow). Cause Memory controller PCB assembly fault, DC controller PCB assembly fault, toner cartridge fault.
- Solutions: – Replace toner cartridge – Replace memory controller PCB – Replace DC controller PCB
- Code: E024-0001
- Description: Toner level sensor failure
- Causes: Failure output from the toner level sensor (Magenta). Cause Memory controller PCB assembly fault, DC controller PCB assembly fault, toner cartridge fault.
- Solutions: – Replace toner cartridge – Replace memory controller PCB – Replace DC controller PCB
- Code: E024-0002
- Description: Toner level sensor failure
- Causes: Failure output from the toner level sensor (Cyan). Cause Memory controller PCB assembly fault, DC controller PCB assembly fault, toner cartridge fault.
- Solutions: – Replace toner cartridge – Replace memory controller PCB – Replace DC controller PCB
- Code: E024-0003
- Description: Toner level sensor failure
- Causes: Failure output from the toner level sensor (Black). Cause Memory controller PCB assembly fault, DC controller PCB assembly fault, toner cartridge fault.
- Solutions: – Replace toner cartridge – Replace memory controller PCB – Replace DC controller PCB
- Code: E066-0000
- Description: Error in environment sensor
- Causes: Failure in environment sensor. Cause Environment sensor fault, DC controller PCB assembly fault.
- Solutions: – Replace environment sensor – Replace DC controller PCB
- Code: E078-0000
- Description: Error in primary transfer estrangement unit
- Causes: Primary transfer estrangement unit does not function properly. Cause Terminal assembly fault, transfer roller estrangement solenoid fault, EBT unit fault, high-voltage power PCB assembly fault.
- Solutions: – Replace ETB estrangement solenoid – Replace ETB unit – Terminal assembly fault (check on every contact between the terminals of each color and the high voltage PCB assembly)
- Code: E100-0000
- Description: Error in scanner motor, laser unit, BD
- Causes: Yellow scanner assembly malfunction. Cause Laser scanner unit fault, DC controller PCB assembly fault.
- Solutions: – Replace laser scanner unit – Replace DC controller PCB
- Code: E100-0001
- Description: Error in scanner motor, laser unit, BD
- Causes: Magenta scanner assembly malfunction. Cause Laser scanner unit fault, DC controller PCB assembly fault.
- Solutions: – Replace laser scanner unit – Replace DC controller PCB
- Code: E100-0002
- Description: Error in scanner motor, laser unit, BD
- Causes: Cyan scanner assembly malfunction. Cause Laser scanner unit fault, DC controller PCB assembly fault.
- Solutions: – Replace laser scanner unit – Replace DC controller PCB
- Code: E100-0003
- Description: Error in scanner motor, laser unit, BD
- Causes: Black scanner assembly malfunction. Cause Laser scanner unit fault, DC controller PCB assembly fault.
- Solutions: – Replace laser scanner unit – Replace DC controller PCB
- Code: E100-0004
- Description: Error in scanner motor, laser unit, BD
- Causes: Failure output of a magenta BD signal Cause laser scanner unit fault, DC controller PCB fault.
- Solutions: – Replace laser scanner unit – Replace DC controller PCB
- Code: E100-0005
- Description: Error in scanner motor, laser unit, BD
- Causes: Failure output of a magenta BD signal Cause laser scanner unit fault, DC controller PCB fault.
- Solutions: – Replace laser scanner unit – Replace DC controller PCB
- Code: E194-0000
- Description: Error in CPR sensor
- Causes: Cannot detect color displacement detection pattern, detected results fall outside the acceptable range. Cause Dirty color displacement detection sensor, color displacement detection sensor fault, DC controller PCB assembly fault, toner cartridge fault.
- Solutions: – Replace ETB unit – Terminal assembly fault (check on every contact between the terminals of each color and the high voltage PCB assembly) – Replace DC controller PCB – Replace toner cartridge
- Code: E196-0001
- Description: Error in DCON ROM
- Causes: Updating the ROM on the DC controller PCB assembly has been failed.
- Solutions: – Replace DC controller PCB
- Code: E197-0000
- Description: Engine communication error
- Causes: Internal communication error
- Solutions: – Replace DC controller PCB – Replace video controller PCB
- Code: E198-0000
- Description: DC controller memory malfunction
- Causes: DC controller memory malfunction. Cause DC controller PCB assembly fault.
- Solutions: – Replace DC controller PCB assembly
- Code: E202-0001
- Description: Reader HP sensor fault
- Causes: Reader HP outward fault The CCD unit moves backward, but does not move to the home position.
- Solutions: – Replace reader HP sensor. – Replace reader motor sensor. – Replace reader unit.
- Code: E202-0002
- Description: Reader HP sensor fault
- Causes: Reader HP homeward fault – Replace reader unit. The CCD unit moves forward, but does not move to the home position.
- Solutions: – Replace reader HP sensor. – Replace reader motor sensor. – Replace reader unit.
- Code: E225-0000
- Description: Error in light intensity of the lamp
- Causes: Decrease of light intensity of the lamp.
- Solutions: Replace reader unit.
- Code: E248-0001
- Description: EEPROM access error
- Causes: Error at EEPROM power-on EEPROM data cannot be read at power-on.
- Solutions: Replace reader unit.
- Code: E248-0002
- Description: EEPROM access error
- Causes: Error in EEPROM writing EEPROM writing cannot be performed.
- Solutions: Replace reader unit.
- Code: E248-0003
- Description: EEPROM access error
- Causes: Error in EEPROM reading after writing EEPROM reading cannot be performed after writing is performed.
- Solutions: Replace reader unit.
- Code: E248-0004
- Description: EEPROM access error
- Causes: Error in EEPROM register writing EEPROM register writing cannot be performed.
- Solutions: Replace reader unit.
- Code: E351-0000
- Description: Main controller PCB fault
- Causes: Internal error of the main controller PCB Cause Main controller PCB fault.
- Solutions: – Check the connection of main controller PCB. – Replace main controller PCB.
- Code: E719-0000
- Description: Communication error of options
- Causes: Erroneous communication with card reader (serial communication) – Disconnection from the card reader has been detected since communication started after confirmation of normal connection to the card reader (after power-on). – A serial communication error has occurred. (The serial communication error cannot be recovered.)
- Solutions: – Check the connectors of the card reader and image processor PCB. – Replace the card reader for normal connection. – Replace the image processor PCB.
- Code: E719-0002
- Description: Communication error of options
- Causes: Erroneous communication with coin vendor (serial communication) – Disconnection from the coin vendor has been detected since communication started after confirmation of normal connection to the coin vendor (after power-on). – A serial communication error has occurred. (The serial communication error cannot be recovered.)
- Solutions: – Check the connection between the image processor PCB and serial PCB. – Check the connectors of the serial PCB and coin vendor for normal connection. – Replace the serial PCB. – Check the coin vendor. – Replace the image processor PCB.
- Code: E744-0001
- Description: Language file/boot ROM/USB memory error
- Causes: Language file version error The language file version does not match Bootable.
- Solutions: Download a language file of the correct version.
- Code: E744-0002
- Description: Language file/boot ROM/USB memory error
- Causes: Language file size error The language file is longer than the permitted size.
- Solutions: Download a language file of the correct version.
- Code: E744-0003
- Description: Language file/boot ROM/USB memory error
- Causes: Language file version error The language file version does not match Bootable.
- Solutions: Download a language file of the correct version.
- Code: E744-0004
- Description: Language file/boot ROM/USB memory error
- Causes: Language file read error Reading of language file is invalid.
- Solutions: Download a language file of the correct version.
- Code: E804-0000
- Description: Error in power supply fan
- Causes: The fan lock detection signal is input for about 10 sec or longer continuously. Cause Power supply fault, DC controller PCB fault.
- Solutions: – Replace the power supply fan – Replace the DC controller PCB
- Code: E805-0005
- Description: Error in duplexing fan/CPU fan
- Causes: The duplexing fan lock detection signal is input for about 10 sec or longer continuously. Cause Duplexing fan fault, DC controller PCB fault.
- Solutions: – Replace the duplexing fan – Replace the DC controller PCB
- Code: E840-0000
- Description: Error in pressure release mechanism
- Causes: Although passing 2.5 sec from the start of HP control, HP (pressure condition) cannot be controlled. Cause Fixing drive assembly fault, fixing pressure release cam fault.
- Solutions: – Replace the fixing drive assembly – Replace the fixing pressure release cam
About Canon Servie Tool V5610
– Canon Service Tool V5610 is a tool used to perform maintenance on Canon printers and reset Canon printers after replacement of parts such as replacing ink absorbents, print heads, printer mainboard, and others. Based on the many cases we have encountered, the Service Tool is most often used to reset ink absorber counter value when the waste ink absorber is full.
– The ink absorber is going to be full of box, it has to be replaced or cleaned the waste ink absorber. Also, replaceing or cleaning the waste ink absorber, you need to repair or reset the waste ink counter value, cause those parts are concerned to each others.
– So using Canon Service Tool V5610 to reset the waste ink counter value becomes effective when the ink absorber is replaced or cleaned.
– Canon Service Tool V5610 can use to fix error code 5B00, 5B02, 5B04, 5B14, 1701, 1702, 1700 on your printer. You must enter Service Mode on your printer to use this Canon Service Tool.
– If the printer can not enter Service Mode, you can not reset it by Canon ST V5610. In this case, change EEPROM on the logic board.
Canon Service Tool V5610 Functions
– Fix Canon printer 7 times/ 8 times red light blinking:
– Fix Canon printer error code: 5B00, 5B01, 1700, 1701
Enter Service Mode on Canon Printer
1. Turn off a printer.
2. Press and hold the Resume/Cancel/Stop button.
3. Press and hold the ON button (do not release both buttons).
4. Release the Resume/Cancel/Stop button (do not release the ON button).
5. While holding the ON button, press the Resume/Cancel/Stop button 5 times, then release both the ON and Resume/Cancel/Stop buttons together.
– Canon printer in service mode: computer detects new hardware, led on printer goes green light.
– Download Canon driver and firmware in specific model: https://dnasofts.com/canon-lbp312dn-printer-driver-firmware-and-user-manual-free-download/
– Download Epson driver and firmware in specific model: https://dnasofts.com/download-epson-d3000-driver-firmware-and-manuals/
Source:
https://chiplessprinter.com/canon-service-tool-v5610.html
https://dnasofts.com
https://shop.nguyendangnam.com/
https://nguyendangnam.me/
https://chiplessprinter.com/reset-epson-waste-ink-pad-counter.html
Contact us to get support with Canon MF9150c Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/