Repair Canon MF8250Cn Printer Error Codes Canon Servie Tool
– Printer model: Canon MF8250Cn
– Error codes on Canon MF8250Cn model and its description:
– Canon MF8250Cn printer Error Codes and quick guide to troubleshooting:
- Code: E000 0000
- Description: Error in the fixing assembly start-up
- Causes: Insufficient temperature rise detected by thermistor even after applying bias to the heater
- Solutions: 1.Check connectors of fixing assembly, DC controller PCB, fixing power supply unit, etc. 2.Replace fixing film units 3.Replace fixing power supply units 4.Replace DC controller PCBs
- Code: E001 0000
- Description: Abnormally high temperature detected in fixing assembly
- Causes: Abnormally high temperature detected by main thermistor
- Solutions: 1.Check connectors of fixing assembly / DC controller PCB 2.Replace fixing film units 3.Replace fixing power supply units 4.Replace DC controller PCB
- Code: E001 0001
- Description: Abnormally high temperature detected in fixing assembly (sub thermistor triggered)
- Causes: Abnormally high temperature detected by sub thermistor (sub thermistor triggered)
- Solutions: 1.Check connectors of fixing assembly / DC controller PCB 2.Replace fixing film units 3.Replace fixing power supply units 4.Replace DC controller PCBs
- Code: E003 0000
- Description: Abnormally low temperature detected in fixing assembly
- Causes: Temperature drop detected by main thermistor after attaining the target temperature
- Solutions: 1.Check connectors of fixing assembly / DC controller PC 2.Replace fixing film/fixing power supply units 3.Replace DC controller PCBs
- Code: E003 0001
- Description: Abnormally low temperature detected in fixing assembly (sub thermistor triggered)
- Causes: Temperature drop detected by sub thermistor after attaining the target temperature (sub thermistor triggered)
- Solutions: 1.Check connectors of fixing assembly / DC controller PCB 2.Replace fixing film units 3.Replace fixing power supply units 4.Replace DC controller PCBs
- Code: E004 0000
- Description: Error in fixing power supply drive circuit.
- Causes: Error in zero-cross signal detection for the pre-defined duration
- Solutions: 1.Check connectors of fixing assembly / DC controller PCB 2.Replace fixing power supply units
- Code: E012 0000
- Description: Error in ITB motor startup
- Causes: Error in attaining the target ITB motor rotation detected based on ITB motor speed detection signal after ITB motor is actuated.
- Solutions: 1.Check connectors of ITB motor / DC controller PCB 2.Replace ITB motors 3.Replace DC controller PCBs
- Code: E012 0001
- Description: Error in ITB motor startup
- Causes: Error in ITB motor rotation after attaining the target rotation detected based on ITB motor speed detection signal
- Solutions: 1.Check connectors of ITB motor / DC controller PCB 2.Replace ITB motors 3.Replace DC controller PCBs
- Code: E014 0000
- Description: Error in fixing motor startup
- Causes: Error in attaining the target fixing motor rotation detected based on fixing motor speed detection signal after fixing motor is actuated.
- Solutions: 1.Check connectors of ITB motor / DC controller PCB 2.Replace ITB motors 3.Replace DC controller PCBs
- Code: E014 0001
- Description: Error in fixing motor startup
- Causes: Error in fixing motor rotation after attaining the target rotation detected based on fixing motor speed detection signal.
- Solutions: 1.Check connectors of ITB motor / DC controller PCB 2.Replace ITB motors 3.Replace DC controller PCBs
- Code: E015 0001
- Description: Error in developing roller contact
- Causes: Failed to detect changes in developing home position sensor signals within the pre-defined time after actuating main motor to control the developing roller contact.
- Solutions: 1.Check connectors of developing home position sensor, main motor and DC controller PCB. 2.Replace developing home position sensors 3.Replace main motors 4.Replace DC controller PCBs
- Code: E020 0000
- Description: Error in density sensor
- Causes: Failed to receive sufficient light to detect image density
- Solutions: 1.Check DC controller PCB onnectors. 2.Replace ITB units 3.Replace DC controller PCBs 4.Replace toner cartridges
- Code: E021 1003
- Description: Error in developing motor
- Causes: Cause of developing motor rotation error: problem in developing motor / DC controller PCB
- Solutions: 1.Check connectors of developing motor and DC controller PCB. 2.Replace developing motor 3.Replace DC controller PCB
- Code: E021 2003
- Description: Error in developing motor
- Causes: Error in attaining the target developing motor rotation detected based on developing motor speed detection signal after developing motor is actuated.
- Solutions: 1.Check connectors of developing motor and DC controller PCB. 2.Replace developing motor 3.Replace DC controller PCBs
- Code: E024 0000
- Description: Error in toner level sensor
- Causes: Abnormal output of toner level sensor (Yellow)
- Solutions: 1.Replace toner cartridges 2.Replace high-voltage power supply PCBs 3.Replace DC controller PCBs
- Code: E024 0001
- Description: Error in toner level sensor
- Causes: Abnormal output of toner level sensor (Magenta)
- Solutions: 1.Replace toner cartridges 2.Replace high-voltage power supply PCBs 3.Replace DC controller PCBs
- Code: E024 0002
- Description: Error in toner level sensor
- Causes: Abnormal output of toner level sensor (Cyan)
- Solutions: 1.Replace toner cartridges 2.Replace high-voltage power supply PCBs 3.Replace DC controller PCBs
- Code: E024 0003
- Description: Error in toner level sensor
- Causes: Abnormal output of toner level sensor (Black)
- Solutions: 1.Replace toner cartridges 2.Replace high-voltage power supply PCBs 3.Replace DC controller PCBs
- Code: E052 0000
- Description: Error in 2-sided unit detection
- Causes: Failed to detect 2-sided unit
- Solutions: 1.Check connectors of 2-sided unit and DC controller PCB 2.Replace DC controller PCBs
- Code: E066 0000
- Description: Error in environment sensor
- Causes: Error in environment sensor
- Solutions: 1.Check connectors of environment sensor and DC controller PCB. 2.Replace environment sensor 3.Replace DC controller PCBs
- Code: E070 0000
- Description: Error in ITB / TOP sensor
- Causes: Error in ITB / TOP sensor
- Solutions: 1.Check connectors of ITB unit and DC controller PCB. 2.Replace ITB units 3.Replace DC controller PCBs
- Code: E078 0000
- Description: Error in primary transfer roller contact
- Causes: Primary transfer roller contact mechanism does not normally function
- Solutions: 1.Check contact mechanism 2.Check connectors of ITB tension sensor, pickup motor and DC controller PCB. 3.Replace ITB tension sensors 4.Replace pickup motors / DC controller PCBs
- Code: E100 0000
- Description: Error in scanner motor/laser unit/BD
- Causes: Failure in Yellow optical unit
- Solutions: 1.Check connectors of laser scanner unit and DC controller PCB 2.Replace laser scanner units 3.Replace DC controller PCBs
- Code: E100 0001
- Description: Error in scanner motor/laser unit/BD
- Causes: Failure in Magenta optical unit
- Solutions: 1.Check connectors of laser scanner unit and DC controller PCB 2.Replace laser scanner units 3.Replace DC controller PCBs
- Code: E100 0002
- Description: Error in scanner motor/laser unit/BD
- Causes: Failure in Cyan optical unit
- Solutions: 1.Check connectors of laser scanner unit and DC controller PCB 2.Replace laser scanner units 3.Replace DC controller PCBs
- Code: E100 0003
- Description: Error in scanner motor/laser unit/BD
- Causes: Failure in Black optical unit
- Solutions: 1.Check connectors of laser scanner unit and DC controller PCB 2.Replace laser scanner units 3.Replace DC controller PCBs
- Code: E110 0000
- Description: Error in primary pseudo-BD correction
- Causes: Scanner failed to be ready after starting up pseudo-BD control
- Solutions: 1.Replace laser scanner units 2.Replace DC controller PCBs
- Code: E194 0000
- Description: Error in Patch Sensor
- Causes: Patch Sensor does not function normally
- Solutions: 1.Check DC controller PCB connectors 2.Replace ITB units 3.Replace DC controller PCBs 4.Replace toner cartridges
- Code: E196 0000
- Description: Error in DCON ROM
- Causes: Failed to update ROM of DC controller PCB
- Solutions: 1.Update the set of main controller firmware 2.Replace DC controller PCB
- Code: E196 1000
- Description: Error in DCON ROM
- Causes: Error in writing in / reading from ROM (main)
- Solutions: 1.Update the set of main controller firmware 2.Replace DC controller PCBs
- Code: E196 2000
- Description: Error in DCON ROM
- Causes: Error in writing in/reading from ROM (storing settings)
- Solutions: 1.Update the set of main controller firmware 2.Replace DC controller PCBs
- Code: E198 0000
- Description: Failure in DC controller memory
- Causes: Failure in DC controller memory
- Solutions: Replace DC controller PCBs
- Code: E202 0001
- Description: Error in reader HP sensor
- Causes: Error in reader HP outward Failed to move to HP even when CIS unit moves backward.
- Solutions: 1.Replace reader HP sensors 2.Replace reader motors 3.Replace reader units
- Code: E202 0002
- Description: Error in reader HP sensor
- Causes: Error in reader HP homeward Failed to move to HP even when CIS unit moves forward.
- Solutions: 1.Replace reader HP sensors 2.Replace reader motors 3.Replace reader units
- Code: E246 0000
- Description: System error
- Causes: System error
- Solutions: Contact to the sales companies.
- Code: E247 0000
- Description: System error
- Causes: System error
- Solutions: Contact to the sales companies.
- Code: E248 0001
- Description: Error in access to backup data for Reader (reading error at power-on)
- Causes: The Reader-related adjustment values could not be read.
- Solutions: 1. Clear the backup RAM of RCON. Execute COPIER>FUNCTION>CLEAR>RCON. 2. Enter all the values written on the service label in service mode again. 3. Turn OFF and then ON the main power.
- Code: E350 0000
- Description: System error
- Causes: System error
- Solutions: Contact to the sales companies.
- Code: E351 0000
- Description: System error
- Causes: System error
- Solutions: 1.Turn OFF and then ON the main power. 2.Replace main controller PCBs
- Code: E354 0000
- Description: System error
- Causes: System error
- Solutions: Contact to the sales companies.
- Code: E355 0000
- Description: System error
- Causes: System error
- Solutions: Contact to the sales companies.
- Code: E355 0004
- Description: System error
- Causes: System error
- Solutions: Contact to the sales companies.
- Code: E355 0005
- Description: System error
- Causes: System error
- Solutions: Contact to the sales companies.
- Code: E719 0000
- Description: Card Reader communication error (serial communication)
- Causes: Communication with the Card Reader could not be started at startup.
- Solutions: 1. Check the connection of the Card Reader-F1, and turn OFF and then ON the main power switch. 2. Remove the Card Reader-F1. NOTE: After performing the Solutions work above, go through the following to clear the error: COPIER> FUNCTION> CLEAR> E719-CLR.
- Code: E733 0000
- Description: Error in printer communication
- Causes: Failure between DC controller PCB and controller PCB
- Solutions: 1.Check connectors of DC controller PCB and main controller PCB 2.Replace DC controller PCBs 3.Replace main controller PCBs
- Code: E736 0000
- Description: Error in CCU communication
- Causes: Error in CCU-modem communication
- Solutions: 1.Update the set of main controller firmware 2.Replace FAX-NCU PCBs 3.Replace main controller PCBs
- Code: E736 0001
- Description: Error in ROM for backing up fax data
- Causes: An error occurred in ROM for backing up fax data
- Solutions: 1. Install the set of the controller firmware. 2. Replace the Main Controller PCB.
- Code: E744 0001
- Description: Error in language file/BootRom/USB memory
- Causes: Error in language file version The version of language file does not match to Bootable
- Solutions: Update the set of main controller firmware
- Code: E744 0002
- Description: Error in language file/BootRom/USB memory
- Causes: Error in language file size Language file exceeds allowable size
- Solutions: Update the set of main controller firmware
- Code: E744 1001
- Description: Error in language file/BootRom/USB memory
- Causes: Versions of Bootable and BootRom do not match
- Solutions: Update the set of main controller firmware
- Code: E744 4000
- Description: Error in language file/BootRom/USB memory
- Causes: Error in engine ID Detected illegal engine connection
- Solutions: 1.Check DC controller 2.Update DC controller firmware 3.Update the set of main controller firmware
- Code: E744 5000
- Description: Error in language file/BootRom/USB memory
- Causes: Error in panel microcomputer
- Solutions: 1.Check panel microcomputer to upgrade the version 2.Update the set of main controller firmware 3.Replace main controller PCBs
- Code: E744 6000
- Description: Communication error with the Wireless LAN PCB
- Causes: Unable to communicate with the Wireless LAN.
- Solutions: 1. Turn OFF and then ON the main power. 2. Check the connection of the Wireless LAN. 3. Install the set of the controller firmware. 4. Replace the Main Controller PCB.
- Code: E744 7000
- Description: Main Controller PCB error
- Causes: An error in the microcomputer which retains fax job information of the Main Controller PCB.
- Solutions: 1. Install the firmware of BKUP. 2. Install the set of the controller firmware. 3. Replace the Main Controller PCB.
- Code: E746 0000
- Description: Error in main controller PCBs
- Causes: Communication error occurred in main controller PCB (other than scanner-related)
- Solutions: Replace main controller PCBs
- Code: E766 8000
- Description: Error in firmware
- Causes: Incorrect digital registration 3 point information
- Solutions: 1.Power off/on 2.Update firmware
- Code: E766 9000
- Description: Error in firmware
- Causes: Error in laser scanner unit power supply
- Solutions: 1.Power off/on 2.Update firmware
- Code: E766 xxxx1
- Description: Error in firmware
- Causes: Error in connection occurred due to main controller software: xxxx Task number related to Exception is shown in decimal
- Solutions: 1.Power off/on 2.Update firmware
- Code: E804 0004
- Description: Error in power supply cooling fan
- Causes: Power supply cooling fan does not rotate in the specified rotation speed.
- Solutions: 1.Check connectors of power supply cooling fan / DC controller PCB 2.Replace power supply cooling fans 3.Replace DC controller PCBs
- Code: E805 0000
- Description: Main Fan error
- Causes: The Main Fan was locked for a specified consecutive period of time.
- Solutions: 1. Check the connection of the Main Fan. 2. Replace the Main Fan.
- Code: E805 0005
- Description: Error in 2-sided cooling fan
- Causes: 2-sided cooling fan does not rotate in the specified rotation speed.
- Solutions: 1.Check connectors of 2-sided cooling fan / DC controller PCB 2.Replace 2-sided cooling fans 3.Replace DC controller PCBs
- Code: E806 0000
- Description: Error in fixing / fixing power supply cooling fan
- Causes: Fixing / fixing power supply cooling fan does not rotate in the specified rotation speed.
- Solutions: 1.Check connectors of fixing/fixing power supply cooling fan and DC controller PCB 2.Replace fixing / fixing power supply cooling fans 3.Replace DC controller PCBs
- Code: E808 0000
- Description: Error in low-voltage power supply
- Causes: Printer detected failure in low-voltage power supply
- Solutions: 1.Check connectors of power supply unit and DC controller PCB 2.Replace power supply units 3.Replace DC controller PCBs
- Code: E840 0000
- Description: Error in pressure release mechanism
- Causes: Failed to control in home position (under pressure) after starting home position control
- Solutions: 1.Replace fixing drive units 2.Replace fixing pressure release cams
About Canon Servie Tool V5610
– Canon Service Tool V5610 is a tool used to perform maintenance on Canon printers and reset Canon printers after replacement of parts such as replacing ink absorbents, print heads, printer mainboard, and others. Based on the many cases we have encountered, the Service Tool is most often used to reset ink absorber counter value when the waste ink absorber is full.
– The ink absorber is going to be full of box, it has to be replaced or cleaned the waste ink absorber. Also, replaceing or cleaning the waste ink absorber, you need to repair or reset the waste ink counter value, cause those parts are concerned to each others.
– So using Canon Service Tool V5610 to reset the waste ink counter value becomes effective when the ink absorber is replaced or cleaned.
– Canon Service Tool V5610 can use to fix error code 5B00, 5B02, 5B04, 5B14, 1701, 1702, 1700 on your printer. You must enter Service Mode on your printer to use this Canon Service Tool.
– If the printer can not enter Service Mode, you can not reset it by Canon ST V5610. In this case, change EEPROM on the logic board.
Canon Service Tool V5610 Functions
– Fix Canon printer 7 times/ 8 times red light blinking:
– Fix Canon printer error code: 5B00, 5B01, 1700, 1701
Enter Service Mode on Canon Printer
1. Turn off a printer.
2. Press and hold the Resume/Cancel/Stop button.
3. Press and hold the ON button (do not release both buttons).
4. Release the Resume/Cancel/Stop button (do not release the ON button).
5. While holding the ON button, press the Resume/Cancel/Stop button 5 times, then release both the ON and Resume/Cancel/Stop buttons together.
– Canon printer in service mode: computer detects new hardware, led on printer goes green light.
– Download Canon driver and firmware in specific model: https://dnasofts.com/canon-c5500-printer-driver-firmware-and-user-manual-free-download/
– Download Epson driver and firmware in specific model: https://dnasofts.com/download-epson-sp-rx580-driver-firmware-and-manuals/
Source:
https://chiplessprinter.com/canon-service-tool-v5610.html
https://dnasofts.com
https://shop.nguyendangnam.com/
https://nguyendangnam.me/
https://chiplessprinter.com/reset-epson-waste-ink-pad-counter.html
Contact us to get support with Canon MF8250Cn Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/