- Code: E000
- Description: Failure in fixing assembly start-up.
- Causes: If increasing temperature is not detected by main thermistor after current distribution to the heater is started. Cause Open circuit in the main thermistor, disconnection in the fixing heater, failure in DC controller PCB
- Solutions: – Check the connectors of fixing assembly, DC controller PCB, and fixing power supply assembly. – Replace the fixing film unit – Replace the fixing power unit – Replace the DC controller PCB
- Code: E001-0000
- Description: Abnormal high temperature in fixing assembly
- Causes: If abnormal high temperature is detected by main thermistor. Cause Failure in sub thermistor, failure in DC controller PCB.
- Solutions: – Check the connectors of fixing assembly and DC controller PCB – Replace the fixing film unit – Replace the fixing power unit – Replace the DC controller PCB
- Code: E001-0001
- Description: Abnormal high temperature in fixing assembly
- Causes: If abnormal high temperature is detected by sub thermistor (caused by sub thermistor). Cause Failure in sub thermistor, failure in DC controller PCB
- Solutions: – Check the connectors of fixing assembly and DC controller PCB – Replace the fixing film unit – Replace the fixing power unit – Replace the DC controller PCB
- Code: E003-0000
- Description: Abnormal low temperature in fixing assembly
- Causes: If decreasing temperature is detected after the main thermistor reaches a specified temperature. Cause Failure in fixing power unit, open circuit in the main thermistor, failure in DC controller PCB.
- Solutions: – Check the connectors of fixing assembly and DC controller PCB – Replace the fixing film unit – Replace the fixing power unit – Replace the DC controller PCB
- Code: E003-0001
- Description: Abnormal low temperature in fixing assembly
- Causes: If decreasing temperature is detected after the sub thermistor reaches a specified temperature. (cause by sub thermistor) Cause Failure in fixing power unit, open dircuit in the sub thermistor, failure in DC controller PCB.
- Solutions: – Check the connectors of fixing assembly and DC controller PCB – Replace the fixing film unit – Replace the fixing power unit – Replace the DC controller PCB
- Code: E004
- Description: Error in fixing current drive circuit.
- Causes: Zero cross signal is not detected within specified time. Cause Failure in fixing control circuit assembly.
- Solutions: – Check the connectors of fixing assembly and DC controller PCB – Replace the fixing power unit
- Code: E012-0000
- Description: Error in ITB motor activation.
- Causes: The cycle of ITB motor speed detection signal does not move in the specified cycle after ITB motor drive is started. Cause Failure in ITB motor, failure in DC controller PCB
- Solutions: – Check the connectors of ITB motor and DC controller PCB – Replace the ITB motor – Replace the DC controller PCB
- Code: E012-0001
- Description: Error in ITB motor activation.
- Causes: If the ITB motor speed detection signal comes off the specified cycle after it turned once to the specified cycle. Cause Failure in ITB motor, failure in DC controller PCB.
- Solutions: – Check the connectors of ITB motor and DC controller PCB – Replace the ITB motor – Replace the DC controller PCB
- Code: E014-0000
- Description: Error in fixing motor drive.
- Causes: The cycle of fixing motor speed detection signal does not move in the specified cycle after fixing motor drive is started. Cause Failure in fixing motor, failure in DC controller PCB
- Solutions: – Check the connectors of ITB motor and DC controller PCB – Replace the ITB motor – Replace the DC controller PCB
- Code: E014-0001
- Description: Error in fixing motor drive.
- Causes: If the fixing motor speed detection signal comes off the specified cycle after it turned once to the specified cycle. Cause Failure in fixing motor, failure in DC controller PCB.
- Solutions: – Check the connectors of ITB motor and DC controller PCB – Replace the ITB motor – Replace the DC controller PCB
- Code: E015-0001
- Description: Error in the developing disengagement movement.
- Causes: For engagement/disengagement movement of the developing roller, the change on the signal condition of the the developing home position sensor cannot be detected within specified time after main motor rotates. Cause Failure in developing home position sensor, failure in main motor, failure in DC controller PCB.
- Solutions: – Check the connectors of the developing home position sensor, main motor, and DC controller PCB. – Replace the developing home position sensor – Replace the main motor – Replace the DC controller PCB
- Code: E020
- Description: Error in density sensor
- Causes: Insufficient light receiving during image density detection. Cause Soiling in density detection sensor, failure in density detection sensor, failure in DC controller PCB, failure in toner cartridge.
- Solutions: – Check the connectors of the DC controller PCB. – Replace the ITB unit – Replace the DC controller PCB – Replace the toner cartridge
- Code: E021-1003
- Description: Error in developing motor
- Causes: Developing motor does not rotate. Cause Failure in developing motor, failure in DC controller PCB.
- Solutions: – Check the connectors of developing motor, DC controller PCB – Replace the developing motor – Replace the DC controller PCB
- Code: E021-2003
- Description: Error in developing motor
- Causes: The cycle of developing motor speed detection signal does not move in the specified cycle after developing motor drive is started. Cause Failure in developing motor, failure in DC controller PC
- Solutions: – Check the connectors of developing motor, DC controller PCB – Replace the developing motor – Replace the DC controller PCB
- Code: E052
- Description: Error in duplex unit detection
- Causes: Can not detect duplex unit. Cause Error in the connection of duplex unit.
- Solutions: – Check the ÇÉonnectors of duplex unit and DC controller PCB – Replace the DC controller PCB
- Code: E066
- Description: Error in the environment detection sensor
- Causes: Error in the environment detection sensor Cause Failure in environment detection sensor, failure in DC controller PCB
- Solutions: – Check the connectors of the environment detection sensor and DC controller PCB – Replace the environment detection sensor – Replace the DC controller PCB
- Code: E070
- Description: Error in ITB/TOP sensor
- Causes: Error in ITB/TOP sensor Cause Failure in ITB/TOP sensor, failure in DC controller PCB
- Solutions: – Check the connectors of the ITB unit and DC controller PCB – Replace the ITB – Replace the DC controller PCB
- Code: E078
- Description: Error in primary transfer disengagement.
- Causes: Primary transfer disengagement system can not work properly. Cause Breakdown in disengagement system, failure in ITB tension sensor, failure in pickup motor, failure in DC controller PCB.
- Solutions: – Check the disengagement system – Check the connectors of ITB tension sensor, pick up motor, and DC controller PCB – Replace the ITB tension sensor
- Code: E100-0000
- Description: Error in scanner motor, laser unit, and BD.
- Causes: Breakdown in yellow scanner assembly. Cause Failure in laser scanner unit, failure in DC controller PCB.
- Solutions: – Check the connectors of the laser scanner unit and DC controller PCB – Replace the laser scanner unit – Replace the DC controller PCB
- Code: E100-0001
- Description: Error in scanner motor, laser unit, and BD.
- Causes: Breakdown in magenta scanner assembly. Cause Failure in laser scanner unit, failure in DC controller PCB.
- Solutions: – Check the connectors of the laser scanner unit and DC controller PCB – Replace the laser scanner unit – Replace the DC controller PCB
- Code: E100-0002
- Description: Error in scanner motor, laser unit, and BD.
- Causes: Breakdown in cyan scanner assembly. Cause Failure in laser scanner unit, failure in DC controller PCB.
- Solutions: – Check the connectors of the laser scanner unit and DC controller PCB – Replace the laser scanner unit – Replace the DC controller PCB
- Code: E100-0003
- Description: Error in scanner motor, laser unit, and BD.
- Causes: Breakdown in black scanner assembly. Cause Failure in laser scanner unit, failure in DC controller PCB.
- Solutions: – Check the connectors of the laser scanner unit and DC controller PCB – Replace the laser scanner unit – Replace the DC controller PCB
- Code: E110
- Description: Error in first artificial BD adjustment
- Causes: If scanner does not become ‘Ready’ after the artifical BD control is started.
- Solutions: – Replace the laser scanner unit – Replace the DC controller PCB
- Code: E194
- Description: Error in CPR sensor
- Causes: If CPR sensor is judged error. Cause Soiling in density detection sensor, failure in density detection sensor, failure in DC controller PCB, failure in toner cartridge.
- Solutions: – Check the connector of DC controller PCB – Replace the ITB unit – Replace the DC controller PCB – Replace the toner cartridge
- Code: E196-0001
- Description: Error in DCON ROM. Failure in ROM update of DC controller PCB
- Causes: Can not access to DC controller NVRAM Cause Failure in DC controller PCB
- Solutions: – Replace the DC controller PCB
- Code: E197-0001
- Description: Engine communication error
- Causes: Error between DC controller PCB and main controller PCB. Cause Failure in connection between PCB, failure in DC controller PCB, failure in controller PCB.
- Solutions: – Check the connection of the connector of the DC controller PCB and controller PCB – Replace the DC controller PCB – Replace the controller PCB
- Code: E198
- Description: Breakdown in DC controller memory
- Causes: Breakdown in DC controller memory Cause Failure in DC controller PCB
- Solutions: – Replace the DC controller PCB
- Code: E747
- Description: EEPROM error
- Causes: Failure in main controller PCB
- Solutions: – Replace the main controller PCB
- Code: E805-0005
- Description: Error in duplex cooling fan
- Causes: Duplex cooling fan can not rotate the specified number of rotations. Cause Failure in duplex cooling fan, failure in DC controller PCB
- Solutions: – Check the connectors of duplex cooling fan and DC controller PCB – Replace the duplex cooling fan
- Code: E806
- Description: Error in power supply cooling fan
- Causes: Power cooling fan can not rotate the specified number of rotations. Cause Failure in power supply cooling fan, failure in DC controller PCB
- Solutions: – Check the connectors of power supply cooling fan and DC controller PCB – Replace the power cooling fan
- Code: E808
- Description: Error in low voltage power supply.
- Causes: If printer detects a breakdown in low voltage power supply. Cause Breakdown in low pressure power supply, failure in DC controller PCB
- Solutions: – Check the connectors of power unit and DC controller PCB – Replace the power unit
- Code: E840
- Description: Error in pressure release system.
- Causes: Control home position (in pressured condition) cannot function after the home position control is started. Cause Failure in fixing drive assembly, failure in fixing pressure release cam.
- Solutions: – Replace the fixing drive assembly – Replace the fixing pressure release cam
About Canon Servie Tool V5610
– Canon Service Tool V5610 is a tool used to perform maintenance on Canon printers and reset Canon printers after replacement of parts such as replacing ink absorbents, print heads, printer mainboard, and others. Based on the many cases we have encountered, the Service Tool is most often used to reset ink absorber counter value when the waste ink absorber is full.
– The ink absorber is going to be full of box, it has to be replaced or cleaned the waste ink absorber. Also, replaceing or cleaning the waste ink absorber, you need to repair or reset the waste ink counter value, cause those parts are concerned to each others.
– So using Canon Service Tool V5610 to reset the waste ink counter value becomes effective when the ink absorber is replaced or cleaned.
– Canon Service Tool V5610 can use to fix error code 5B00, 5B02, 5B04, 5B14, 1701, 1702, 1700 on your printer. You must enter Service Mode on your printer to use this Canon Service Tool.
– If the printer can not enter Service Mode, you can not reset it by Canon ST V5610. In this case, change EEPROM on the logic board.
Canon Service Tool V5610 Functions
– Fix Canon printer 7 times/ 8 times red light blinking:
– Fix Canon printer error code: 5B00, 5B01, 1700, 1701
Enter Service Mode on Canon Printer
1. Turn off a printer.
2. Press and hold the Resume/Cancel/Stop button.
3. Press and hold the ON button (do not release both buttons).
4. Release the Resume/Cancel/Stop button (do not release the ON button).
5. While holding the ON button, press the Resume/Cancel/Stop button 5 times, then release both the ON and Resume/Cancel/Stop buttons together.
– Canon printer in service mode: computer detects new hardware, led on printer goes green light.
– Download Canon driver and firmware in specific model: https://dnasofts.com/canon-ts9520-(ts9500)-printer-driver-firmware-and-user-manual-free-download/
– Download Epson driver and firmware in specific model: https://dnasofts.com/download-epson-c823301-driver-firmware-and-manuals/
Source:
https://chiplessprinter.com/canon-service-tool-v5610.html
https://dnasofts.com
https://shop.nguyendangnam.com/
https://nguyendangnam.me/
https://chiplessprinter.com/reset-epson-waste-ink-pad-counter.html
Contact us to get support with Canon LBP7200Cdn Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/