Repair Canon iR1435 Printer Error Codes Canon Servie Tool
– Printer model: Canon iR1435
– Error codes on Canon iR1435 model and its description:
– Canon iR1435 printer Error Codes and quick guide to troubleshooting:
- Code: 10-0020
- Description: Toner low alarm
- Causes: Toner low alarm
- Solutions: The host machine requests UGW for pre-delivery of the toner either when remaining quantity of the toner reaches to the setting value (%) or toner empty is detected by the toner sensor (SR17). The alarm log is reported on the following service mode. • COPIER > FUNCTION > MISC-P > ERR-LOG
- Code: 10-0100
- Description: Toner cartridge replacement alarm
- Causes: Toner cartridge replacement alarm
- Solutions: When the toner cartridge replacement is detected. The alarm log is reported on the following service mode. • COPIER > FUNCTION > MISC-P > ERR-LOG
- Code: 35-0073
- Description: Drum unit replacement completion alarm
- Causes: Drum unit replacement completion alarm
- Solutions: When the drum unit replacement completion is detected. The alarm log is reported on the following service mode. • COPIER > FUNCTION > MISC-P > ERR-LOG
- Code: 35-0091
- Description: ADF pickup roller unit replacement completion alarm
- Causes: ADF pickup roller unit replacement completion alarm
- Solutions: ADF pickup roller unit replacement completion is notified.
- Code: 35-0092
- Description: ADF separation pad replacement completion alarm
- Causes: ADF separation pad replacement completion alarm
- Solutions: ADF separation pad replacement completion is notified.
- Code: 40-0073
- Description: Drum low alarm
- Causes: Drum low alarm
- Solutions: The host machine requests UGW for pre-delivery of the drum unit either when life of the drum unit reaches to the setting value (%) or full of waste toner is detected by the waste toner full sensor (SR6). The alarm log is reported on the following service mode. • COPIER > FUNCTION > MISC-P > ERR-LOG
- Code: 85-0001 … 85-0005
- Description: System error
- Causes: System error
- Solutions: Auto recovery due to replacement with a new Main Controller PCB, which is a service part.
- Code: E000 0000
- Description: Fixing assembly temperature rising error during the startup
- Causes: The fixing assembly does not rise to the constant temperature within specified time.
- Solutions: 1. Clear error on the following service mode. Turn OFF and then ON the main power switch. COPIER> FUNCTION> CLEAR> ERR 2. Check connection between the fixing assembly and the engine controller PCB (PCB1). 3. Check connection between the fixing assembly and the power supply PCB (PCB4). 4. Check connection between the engine contorller PCB (PCB1) and the power supply PCB (PCB4). 5. Replace the fixing assembly. 6. Replace the engine controller PCB (PCB1). 7. Replace the power supply PCB (PCB4).
- Code: E001 0000
- Description: Fixing assembly abnormal high temperature (main thermistor )
- Causes: Abnormal high temperature is detected at the main thermistor in the fixing assembly.
- Solutions: 1. Clear error on the following service mode. Turn OFF and then ON the main power switch. COPIER> FUNCTION> CLEAR> ERR 2. Check connection between the fixing assembly and the engine controller PCB (PCB1). 3. Check connection between the fixing assembly and the power supply PCB (PCB4). 4. Check connection between the engine contorller PCB (PCB1) and the power supply PCB (PCB4). 5. Replace the fixing assembly. 6. Replace the engine controller PCB (PCB1). 7. Replace the power supply PCB (PCB4).
- Code: E001 0001
- Description: Fixing assembly abnormal high temperature (sub thermistor )
- Causes: Abnormal high temperature is detected at the sub thermistor in the fixing assembly.
- Solutions: 1. Clear error on the following service mode. Turn OFF and then ON the main power switch. COPIER> FUNCTION> CLEAR> ERR 2. Check connection between the fixing assembly and the engine controller PCB (PCB1). 3. Check connection between the fixing assembly and the power supply PCB (PCB4). 4. Check connection between the engine contorller PCB (PCB1) and the power supply PCB (PCB4). 5. Replace the fixing assembly. 6. Replace the engine controller PCB (PCB1). 7. Replace the power supply PCB (PCB4).
- Code: E002 0000
- Description: Fixing assembly temperature rising error
- Causes: The fixing assembly does not rise to the constant temperature within specified time.
- Solutions: 1. Clear error on the following service mode. Turn OFF and then ON the main power switch. COPIER> FUNCTION> CLEAR> ERR 2. Check connection between the fixing assembly and the engine controller PCB (PCB1). 3. Check connection between the fixing assembly and the power supply PCB (PCB4). 4. Check connection between the engine contorller PCB (PCB1) and the power supply PCB (PCB4). 5. Replace the fixing assembly. 6. Replace the engine controller PCB (PCB1). 7. Replace the power supply PCB (PCB4).
- Code: E003 0000
- Description: Fixing assembly abnormal low temperature (main thermistor )
- Causes: The main thermistor detects abnormal low temperature.
- Solutions: 1. Clear error on the following service mode. Turn OFF and then ON the main power switch. COPIER> FUNCTION> CLEAR> ERR 2. Check connection between the fixing assembly and the engine controller PCB (PCB1). 3. Check connection between the fixing assembly and the power supply PCB (PCB4). 4. Check connection between the engine contorller PCB (PCB1) and the power supply PCB (PCB4). 5. Replace the fixing assembly. 6. Replace the engine controller PCB (PCB1). 7. Replace the power supply PCB (PCB4).
- Code: E003 0001
- Description: Fixing assembly abnormal low temperature (sub thermistor )
- Causes: The sub thermistor detects abnormal low temperature.
- Solutions: 1. Clear error on the following service mode. Turn OFF and then ON the main power switch. COPIER> FUNCTION> CLEAR> ERR 2. Check connection between the fixing assembly and the engine controller PCB (PCB1). 3. Check connection between the fixing assembly and the power supply PCB (PCB4). 4. Check connection between the engine contorller PCB (PCB1) and the power supply PCB (PCB4). 5. Replace the fixing assembly. 6. Replace the engine controller PCB (PCB1). 7. Replace the power supply PCB (PCB4).
- Code: E004 0000
- Description: Error in fixing power supply drive circuit.
- Causes: When thermistor disconnection is detected. Abnormally high temperature detected by thermistor.
- Solutions: 1. Check connection of the thermistor relay connector. -Main thermistor relay connector: J37 -Sub thermistor relay connector: J37 2. Check connection between the fixing assembly and the engine controller (PCB1). 3. Replace the fixing assembly. 4. Replace the engine controller PCB (PCB1).
- Code: E010
- Description: Main motor (M1) start error
- Causes: ‘Speed lock signal =0’ is detected more than 1.0 sec continuously after the main motor (M1) starts to drive and ‘Speed lock signal =1’ is detected.
- Solutions: 1. Check connection to the main motor (M1). 2. Replace the main motor (M1). 3. Replace the engine controller PCB (PCB1).
- Code: E010 0000
- Description: Main motor (M1) rotation error
- Causes: ‘Speed lock signal =1’ is not detected more than 2.0 sec or more after the main motor (M1) starts to drive.
- Solutions: 1. Check connection to the main motor (M1). 2. Replace the main motor (M1). 3. Replace the engine controller PCB (PCB1).
- Code: E014 0000
- Description: Fixing motor (M3) start error
- Causes: ‘Speed lock signal =1’ is not detected more than 2.0 sec or more after the fixing motor (M3) starts to drive.
- Solutions: 1. Check connection to the fixing motor (M3). 2. Replace the fixing motor (M3). 3. Replace the engine controller PCB (PCB1).
- Code: E014 0001
- Description: Fixing motor (M3) rotation error
- Causes: Fixing motor (M3) rotation error
- Solutions: 1. Check connection to the fixing motor (M3). 2. Replace the fixing motor (M3). 3. Replace the engine controller PCB (PCB1).
- Code: E014 0002
- Description: Fixing motor (M3) pressure releasing error
- Causes: ‘Speed lock signal =0’ is detected more than 1.0 sec continuously after the fixing motor (M3) starts to drive and ‘Speed lock signal =1’ is detected.
- Solutions: 1. Check connection to the fixing motor (M3). 2. Replace the fixing motor (M3). 3. Replace the engine controller PCB (PCB1).
- Code: E014 0003
- Description: Fixing motor (M3) pressure error
- Causes: Fixing pressure is never detected more than 3 sec or more by the fixing pressure release sensor (SR15/16) after fixing pressure drives.
- Solutions: 1. Check connection to the fixing motor (M3). 2. Replace the fixing motor (M3). 3. Replace the engine controller PCB (PCB1).
- Code: E024 0000
- Description: Developing Assembly error
- Causes: Disconnection is detected 10 times in 10 ms cycle by connection detection signal of the toner sensor (SR17).
- Solutions: 1. Check connection between the Developing Assembly and the engine controller PCB (PCB1). 2. Replace the Developing Assembly 3. Replace the engine controller PCB (PCB1).
- Code: E110 0000
- Description: Polygon motor (M2) rotation error
- Causes: The laser scanner unit is not prepared after controlling the polygon motor rotation speed starts.
- Solutions: 1. Check connection to the polygon motor (M2). 2. Replace the laser scanner unit. 3. Replace the engine controller PCB (PCB1).
- Code: E196 0000
- Description: Error of reading data in the EEPROM
- Causes: Fail to read EEPROM data at startup.
- Solutions: 1. Update the set of main controller firmware 2. Replace Engine controller PCB
- Code: E196 0001
- Description: Error of access data in the EEPROM
- Causes: Fail to access EEPROM data.
- Solutions: Replace the engine controller PCB (PCB1).
- Code: E196 0002
- Description: Error of writing data in the EEPROM
- Causes: Fail to write EEPROM data.
- Solutions: Replace the engine controller PCB (PCB1).
- Code: E196 1000
- Description: Main Controller PCB reading/writing error
- Causes: Error in reading/writing of main program in the Main Controller PCB
- Solutions: 1. Install the set of the controller firmware. 2. Replace the Main Controller PCB.
- Code: E196 2000
- Description: Main Controller PCB reading/writing error
- Causes: Error in reading/writing of setting values storage area in the Main Controller PCB
- Solutions: 1. Install the set of the controller firmware. 2. Replace the Main Controller PCB.
- Code: E202 0001
- Description: CIS unit HP error
- Causes: When the CIS unit is not detected by the CIS unit HP sensor (SR03).
- Solutions: 1. Replace the CIS unit HP sensor (SR03). 2. Replace the reader motor (M02). 3. Replace the main controller PCB (PCB2).
- Code: E202 0002
- Description: CIS unit HP error
- Causes: When the CIS unit is not moved from the CIS unit HP sensor (SR03).
- Solutions: 1. Replace the CIS unit HP sensor (SR03). 2. Replace the reader motor (M02). 3. Replace the main controller PCB (PCB2).
- Code: E225 0001
- Description: CIS unit light intensity is under the standard level
- Causes: CIS unit light intensity is under the standard level while shading.
- Solutions: 1. Remove/connect the flat cable. 2. Replace the flat cable. 3. Replace the CIS unit. 4. Replace the main controller PCB (PCB2).
- Code: E246 0000
- Description: System error
- Causes: System error
- Solutions: Contact to the sales companies.
- Code: E247 0000
- Description: System error
- Causes: System error
- Solutions: Contact to the sales companies.
- Code: E248 0001
- Description: Error in access to backup data for Reader (reading error at power-on)
- Causes: The Reader-related adjustment values could not be read.
- Solutions: 1. Clear the backup RAM of RCON. Execute COPIER>FUNCTION>CLEAR>RCON. 2. Enter all the values written on the service label in service mode again. 3. Turn OFF and then ON the main power.
- Code: E250 0000
- Description: One-touch Key Cover sensor error
- Causes: One-touch Key Cover sensor error
- Solutions: 1. Check the One-touch Key Cover sensor. 2. Turn OFF and then ON the main power. 3. Replace Control Panel PCB.
- Code: E261 0000
- Description: Driving circuit error
- Causes: Zero cross detection error
- Solutions: 1. Check connection of the connectors. 2. Replace the engine controller PCB (PCB1). 3. Replace the AC driver PCB (PCB3).
- Code: E280 0005 … E355 0005
- Description: System error
- Causes: System error
- Solutions: Contact to the sales companies.
- Code: E719 0000
- Description: Card Reader communication error (serial communication)
- Causes: Communication with the Card Reader could not be started at startup.
- Solutions: 1. Check the connection of the Card Reader-F1, and turn OFF and then ON the main power switch. 2. Remove the Card Reader-F1. NOTE: After performing the Solutions work above, go through the following to clear the error: COPIER> FUNCTION> CLEAR> E719-CLR.
- Code: E732 0000
- Description: Scanner communication error
- Causes: Scanner communication error
- Solutions: 1. Install the set of the controller firmware. 2. Replace the Main Controller PCB.
- Code: E733 0000
- Description: Error in printer communication
- Causes: Failure between DC controller PCB and controller PCB
- Solutions: 1. Check connectors of DC controller PCB and main controller PCB 2. Replace DC controller PCBs 3. Replace main controller PCBs
- Code: E736 0000
- Description: Error in CCU communication
- Causes: Error in CCU-modem communication
- Solutions: 1. Update the set of main controller firmware 2. Replace FAX-NCU PCBs 3. Replace main controller PCBs
- Code: E744 0001
- Description: Language file version error
- Causes: Language file version was not matched with the main program.
- Solutions: Install the set of the controller firmware.
- Code: E744 0002
- Description: Language file size error
- Causes: The size of the language file exceeded the upper limit.
- Solutions: Install the set of the controller firmware.
- Code: E744 1001
- Description: Firmware version error
- Causes: Version of the main program and the version of the start-up program was not matched.
- Solutions: Install the set of the controller firmware.
- Code: E744 4000
- Description: Engine ID error
- Causes: Invalid engine connection was detected.
- Solutions: 1. Turn OFF and then ON the main power. 2. Check the Engine Controller PCB. 3. Install the Engine Controller PCB. 4. Install the set of the controller firmware. 5. Check the model code. (When the model code and the engine code are mismatched, E744-4000 occurs.)
- Code: E744 5000
- Description: Error in the Control Panel PCB
- Causes: Error in the Control Panel PCB (microcomputer).
- Solutions: 1. Check the Control Panel PCB, and install the firmware (PANEL). 2. Install the set of the controller firmware. 3. Replace the Main Controller PCB.
- Code: E746 0000
- Description: Error in main controller PCBs
- Causes: Communication error occurred in main controller PCB (other than scanner-related)
- Solutions: Replace main controller PCBs
- Code: E766 8000
- Description: Digital registration error
- Causes: Information at digital registration could not be obtained.
- Solutions: 1. Install the Engine Controller firmware. 2. Install the set of the controller firmware. 3. Replace the Engine Controller PCB.
- Code: E766 xxxx *1
- Description: Firmware error
- Causes: An error due to the controller software occurred so that print could not be proceeded.
- Solutions: Due to firmware error, the possibility of solving the error by replacing the Main Controller PCB is low. Check the installed engine again.
- Code: E804 0004
- Description: Controller Fan error
- Causes: Since the startup of the Controller Fan, the Fan was locked for a specified consecutive period of time.
- Solutions: 1. Check power supply to the Controller Fan. 2. Replace the Controller Fan.
- Code: E805 0000
- Description: Delivery cooling fan (FM1) error
- Causes: • FAN driving: When ‘Lock signal = High’ is detected more than 5 sec or more continuously. • FAN suspended: When ‘Lock signal = Low’ is detected more than 10 sec or more continuously
- Solutions: 1. Check connection to the delivery cooling fan (FM1). 2. Replace the delivery cooling fan (FM1).
- Code: E805 0001
- Description: Image formation part cooling fan (FM3) error
- Causes: • FAN driving: When ‘Lock signal = High’ is detected more than 5 sec or more continuously. • FAN suspended: When ‘Lock signal = Low’ is detected more than 10 sec or more continuously.
- Solutions: 1. Check connection to the Image formation part cooling fan (FM3). 2. Replace the Image formation part cooling fan (FM3).
- Code: E805 0002
- Description: Power supply cooling fan (FM2) error
- Causes: • FAN driving: When ‘Lock signal = High’ is detected more than 5 sec or more continuously. • FAN suspended: When ‘Lock signal = Low’ is detected more than 10 sec or more continuously.
- Solutions: 1. Check connection to the power supply cooling fan (FM2). 2. Replace the power supply cooling fan (FM2).
- Code: E996 0071
- Description: Sequence jam error
- Causes: 30 sec JAM timer (timing error jam), which sets at the timing when ADF motor is driven, occurs time out.
- Solutions: 1. Check connection of the connectors. 2. Replace the main controller PCB (PCB2). 3. Replace the reader unit.
About Canon Servie Tool V5610
– Canon Service Tool V5610 is a tool used to perform maintenance on Canon printers and reset Canon printers after replacement of parts such as replacing ink absorbents, print heads, printer mainboard, and others. Based on the many cases we have encountered, the Service Tool is most often used to reset ink absorber counter value when the waste ink absorber is full.
– The ink absorber is going to be full of box, it has to be replaced or cleaned the waste ink absorber. Also, replaceing or cleaning the waste ink absorber, you need to repair or reset the waste ink counter value, cause those parts are concerned to each others.
– So using Canon Service Tool V5610 to reset the waste ink counter value becomes effective when the ink absorber is replaced or cleaned.
– Canon Service Tool V5610 can use to fix error code 5B00, 5B02, 5B04, 5B14, 1701, 1702, 1700 on your printer. You must enter Service Mode on your printer to use this Canon Service Tool.
– If the printer can not enter Service Mode, you can not reset it by Canon ST V5610. In this case, change EEPROM on the logic board.
Canon Service Tool V5610 Functions
– Fix Canon printer 7 times/ 8 times red light blinking:
– Fix Canon printer error code: 5B00, 5B01, 1700, 1701
Enter Service Mode on Canon Printer
1. Turn off a printer.
2. Press and hold the Resume/Cancel/Stop button.
3. Press and hold the ON button (do not release both buttons).
4. Release the Resume/Cancel/Stop button (do not release the ON button).
5. While holding the ON button, press the Resume/Cancel/Stop button 5 times, then release both the ON and Resume/Cancel/Stop buttons together.
– Canon printer in service mode: computer detects new hardware, led on printer goes green light.
– Download Canon driver and firmware in specific model: https://dnasofts.com/canon-c10000vp-c8000vp-printer-driver-firmware-and-user-manual-free-download/
– Download Epson driver and firmware in specific model: https://dnasofts.com/download-epson-nx115-driver-firmware-and-manuals/
Source:
https://chiplessprinter.com/canon-service-tool-v5610.html
https://dnasofts.com
https://shop.nguyendangnam.com/
https://nguyendangnam.me/
https://chiplessprinter.com/reset-epson-waste-ink-pad-counter.html
Contact us to get support with Canon iR1435 Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/