Fixing Mimaki JV4-180 Error Codes list
– Compatible Printer model: Mimaki JV4-180
– Mimaki JV4-180 Error Code description:
- Code: 01
- Display: ERROR01 MAIN ROM
- Description: • The control ROM is in abnormal conditions.
- Troubleshooting Guides: 1) Replace the main PCB with a new one.
- Code: 02
- Display: ERROR02 MAIN RAM
- Description: • The control RAM is in abnormal conditions.
- Troubleshooting Guides: 1) Replace the main PCB with a new one.
- Code: 03
- Display: ERROR03 POWER +35V
- Description: •The +35V voltage is in abnormal conditions.
- Troubleshooting Guides: 1) Replace the the main PCB with a new one.
- Code: 04
- Display: ERROR04 FLASH ROM
- Description: • The Flash memory is in abnormal conditions.
- Troubleshooting Guides: 1) Replace the main PCB with a new one.
- Code: 06
- Display: ERROR06 D-RAM
- Description: • An error has occurred in the D-RAM.
- Troubleshooting Guides: 1) Replace the main PCB with a new one.
- Code: 07
- Display: ERROR07 TEMP n
- Description: • Abnormal temperature is detected.
- Troubleshooting Guides: 1) Has ink in the camper run out? 2) Replace the HDC PCB with a new one. 3) Replace the head with a new one.
- Code: 08
- Display: ERROR08 Linear Encoder n
- Description: • The Linear encoder is in abnormal conditions.
- Troubleshooting Guides: 1) Replace the Linear encoder with a new one. 2) Replace the main PCB with a new one.
- Code: 09
- Display: ERROR09 HDC
- Description: • Configuration of PDC/IOC has not been successfully carried out. • Configuration of HDC has not been successfully carried out.
- Troubleshooting Guides: 1) Replace the main PCB with a new one. 2) Replace the HDC PCB with a new one.
- Code: 10
- Display: ERROR10 COMMAND
- Description: • Command code other than MRL has been received.
- Troubleshooting Guides: 1) Check the data received through HEX dump. 2) If error occurs at 1394 a. Check Time out of the transfer tool (RIP). b. Replace the I/F connection board with [E102154A] or later. c. Replace the 1394 board with a new one. d. Replace the main PCB with a new one.
- Code: 11
- Display: ERROR11 PARAMETER
- Description: • Parameter that has not defined in MRL has been received.
- Troubleshooting Guides: 1) Check the data received through HEX dump. 2) If error occurs at 1394 a. Check Time out of the transfer tool (RIP). b. Replace the I/F connection board with [E102154A] or later. c. Replace the 1394 board with a new one. d. Replace the main PCB with a new one.
- Code: 12
- Display: ERROR12 Ment Command
- Description: • A command error for manufacture of has occurred .
- Troubleshooting Guides: 1) It is not used in the field.
- Code: 20
- Display: ERROR20 I/F BOARD
- Description: • A error occurred in communication between the main PCB and the interface board.
- Troubleshooting Guides: 1) Replace the I/F PCB with a new one. 2) Replace the main PCB with a new one. 3) Replace the I/F connection board with a new one.
– Mimaki JV4-180 Error codes and solution steps to solve problems:
- Code: 21
- Display: ERROR21 I/F NONE
- Description: • The I/F board could not be recognized.
- Troubleshooting Guides: 1) Is the I/F board mounted correctly ?
- Code: 23
- Display: ERROR23 HOST I/F
- Description: • A time limit exceeded error occurred in communication between the host computer and the interface board.
- Troubleshooting Guides: 1) Is the cable loose? 2) Has an error occurred on the host computer? 3) Is the application being used running normally?
- Code: 24
- Display: ERROR24 I/F INITIAL
- Description: • The I/F board is in abnormal conditions.
- Troubleshooting Guides: 1) Replace the I/F PCBwith a new one. 2) Replace the main PCB with a new one. 3) Replace the main PCB with a new one.
- Code: 30
- Display: ERROR30 OPERATION
- Description: • Improper operation has been performed.
- Troubleshooting Guides: 1) Indicate the improper operation. 2) Replace a key board. 3) Replace a main PCB.
- Code: 34
- Display: ERROR34 DATA REMAIN
- Description: • Operating condition is tried to be changed when data that has not yet been plotted remains.
- Troubleshooting Guides: 1) This tells that any of the operating conditions cannot be changed if data that have not been plotted remains.
- Code: 40
- Display: ERROR40 MOTOR X
- Description: • The X-axis motor has been overloaded.
- Troubleshooting Guides: 1) Replace X axis motor. 2) Replace a main PCB.
- Code: 41
- Display: ERROR41 MOTOR Y
- Description: • The Y-axis motor has been overloaded. • The brush of motor is in abnormal conditions.
- Troubleshooting Guides: 1) Clean the main guide axis. 2) Replace Y axis motor. 3) Replace a main PCB.
- Code: 42
- Display: ERROR42 X CURRENT
- Description: • Overcurrent error has arisen on the X-axis motor
- Troubleshooting Guides: 1) Replace X axis motor. 2) Replace a main PCB.
- Code: 43
- Display: ERROR43 Y CURRENT
- Description: • Overcurrent error has arisen on the Y-axis motor
- Troubleshooting Guides: 1) Replace Y axis motor. 2) Replace a main PCB.
- Code: 45
- Display: ERROR45 CAPPING
- Description: • The capping-control is in abnormal conditions.
- Troubleshooting Guides: 1) Turn on the power. 2) Replace a slider PCB. 3) Replace a cap sensor. 4) Replace a IO PCB. 5) Replace a station sensor. 6) Replace a station motor.
- Code: 46
- Display: ERROR46 WIPER
- Description: • The wiper-control is in abnormal conditions
- Troubleshooting Guides: 1) Turn on the power. 2) Replace a wiper assy. 3) Replace IO PCB. 4) Replace a wiper sensor. 5) Replace a wiper motor.
- Code: 50
- Display: ERROR50 MEDIA SENSE
- Description: • Media detection has not been successfully carried out.
- Troubleshooting Guides: 1) Make sure that there is no gap between platen F (aluminum) and the edge of the P cover F rubber. If there is a gap, stick the rubber appressed against the platen. The gap may be detected in mistake. 2) Make sure that platen cover F is fixed securely using the platen cover F mounting screws (attached on auxiliary side plates R and L to prevent the cover from protruding). 3) Check if the media right edge is set at a position 15mm or more from the rightmost edge of the rightmost feed roller:R1 toward the station side or not. 4) Cleaning or replace a paper width sensor. 5) Replace a main FPC cable. 6) Replace a slider PCB. 7) Replace a HDC-4Head PCB. 8) Replace a main PCB.
- Code: 51
- Display: ERROR51 Y ORIGIN
- Description: • Y-axis origin detection has not been successfully carried out.
- Troubleshooting Guides: 1) Replace a Y axis motor. 2) Replace a Y origin sensor. 3) Replace a IO PCB. 4) Replace a main PCB.
Waste Ink Pad Counter Utility Functions:
– Cleaning printhead.
– Ink charge.
– Fix Epson red lights blinking Error
– Fix Epson Service Required Error: A printer’s ink pad at the end of its service life Please contact Epson Support.
– Check the current value of waste ink counters and ink level counters.
– Clear Waste Ink Counters.
– Read and write serial number.
– Read and write USB ID.
– Read and write HEAD ID.
– Make EEPROM dump, backup.
– Paper feed test.
– Nozzle check.
– Color check pattern.
– Initialize (disable) PF deterioration offset.
– Retrieve device information
Contact us to get support with Mimaki JV4-180 Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/