Fixing Kyocera KMC3232 Printer Error Codes in details
– Printer model: Kyocera KMC3232
– Fix Error codes on Kyocera KMC3232 model and its description:
- Code: C0030
- Description: Fax control PWB system problem (optional fax) Processing with the fax software was disabled due to a hardware or software problem.
- Causes: Defective fax control PWB.
- Remedy: Defective fax control PWB. Replace the fax control PWB and verify the operation.
- Code: C0070
- Description: Abnormal detection of fax control PWB incompatibility (optional fax) In the initial communication with the fax control PWB, any normal communication command is not transmitted.
- Causes: Defective fax software. Defective fax control PWB.
- Remedy: Defective fax software. Install the fax software. Defective fax control PWB. Replace the fax control PWB and verify the operation.
- Code: C0100
- Description: Main PWB backup memory device problem Writing or erasing has not completed even after a certain time.
- Causes: Defective main PWB.
- Remedy: Defective main PWB. Replace the main PWB and check for correct operation.
- Code: C0110
- Description: Backup memory data problem Data in the specified area of the backup memory does not match the specified values.
- Causes: Problem with the backup memory data.
- Remedy: Problem with the backup memory data. Run maintenance item U020 to initialize the backup memory data.
- Code: C0150
- Description: Backup memory device problem (Engine PWB) An error occurs in backup data read or write for the engine PWB. An error occurs in control area deletion.
- Causes: Defective engine PWB. Data damage of EEPROM.
- Remedy: Defective engine PWB. Replace the engine PWB and check for correct operation. Data damage of EEPROM. Contact the Service Administrative Division.
- Code: C0160
- Description: Backup memory data problem (Engine PWB) Data for backup data check is changed at the check after startup.
- Causes: Problem with the backup memory data.
- Remedy: Problem with the backup memory data. Run maintenance item U020 to initialize the backup memory data.
- Code: C0170
- Description: Copy counts problem A checksum error is detected in the main and sub backup memories for the copy counters.
- Causes: Data damage of EEPROM.Defective main PWB.
- Remedy: Data damage of EEPROM. Contact the Service Administrative Division. Defective main PWB. Replace the main PWB and check for correct operation.
- Code: C0180
- Description: Backup memory data problem Backup data on the main PWB has broken.
- Causes: Data damage of EEPROM.
- Remedy: Data damage of EEPROM. Contact the Service Administrative Division if the problem occurs frequently.
- Code: C0210
- Description: CPU communication problem There is no reply after 3 retries at communication.
- Causes: Poor contact in the connector terminals. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of the engine PWB and main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective PWB. Replace the engine PWB or main PWB and check for correct operation.
- Code: C0220
- Description: Communication problem between the scanner PWB and main PWB There is no reply after 6 retries at communication.
- Causes: Poor contact in the connector terminals. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector on the scanner PWB and the connector on the main PWB. Repair or replace if necessary. Defective PWB. Replace the scanner PWB or main PWB and check for correct operation.
- Code: C0240
- Description: Printer PWB communication problem The printer PWB does not respond 120 s after the power is turned on.
- Causes: Poor contact in the connector terminals. DIMM or DDR installed incorrectly. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC21 on the engine PWB and the connector YC7 on the printer PWB, and the continuity across the connector terminals. Repair or replace if necessary. DIMM or DDR installed incorrectly. Check the connection of DIMM or DDR. Repair or replace if necessary. Defective PWB. Replace the printer PWB or engine PWB and check for correct operation.
- Code: C0250
- Description: Network scanner PWB communication problemThe response to the alive command to the network scanner transmitted once to 30 s does not come on the contrary three consecutive times or more. The response to the communication command transmitted to the network scanner does not return 75 s or more. (This code indicates only scanner function display.
- Causes: Poor contact in the connector terminals. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC4 on the main PWB and the connector YC1 on the network scanner PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective PWB. Replace the scanner network PWB or main PWB and check for correct operation.
- Code: C0280
- Description: Communication problem between the fax control PWB and main PWB After main PWB status change signal turns on 1 minute, when it does not receive key required command from the fax control PWB, one time it resets the FAX.After that, while main PWB status change signal turns on furthermore 1 minute, when it does not receive key required command from the fax control PWB. When FAX_READY signal continues fake for 6 s, one time it resets the FAX. After that, when FAX_READY fake continues fake for 6 s.
- Causes: Poor contact in the connector terminals. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC6 on the main PWB and the connector on the fax control PWB, connection of connector YC1 on the fax control PWB and the connector on the fax relay PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective PWB. Replace the fax control PWB or main PWB and check for correct operation.
- Code: C0410
- Description: DP communication problem (optional DP) There is no reply after 10 retries at communication or a communication error occurs.
- Causes: Poor contact in the connector terminals. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC17 on the scanner PWB and the connector YC1 on the DP drive PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective PWB. Replace the DP drive PWB or scanner PWB and check for correct operation.
- Code: C0420
- Description: Paper feeder communication error (optional paper feeder) A communication error from paper feeder is detected 10 times in succession.
- Causes: Poor contact in the connector terminals. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC33 on the engine PWB and the connector YC1 on the paper feeder main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective PWB. Replace the paper feeder main PWB or engine PWB and check for correct operation.
- Code: C0440
- Description: Document finisher communication problem (optional document finisher) A communication error from document finisher is detected 10 times in succession.
- Causes: Poor contact in the connector terminals. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC33 on the engine PWB and the connector on the finisher main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective PWB. Replace the finisher main PWB or engine PWB and check for correct operation.
- Code: C0610
- Description: Bitmap problem The DIMM on the main PWB does not operate correctly.
- Causes: Defective main PWB. DDR on the main PWB installed incorrectly.
- Remedy: Defective main PWB. Replace the main PWB and check for correct operation. DDR on the main PWB installed incorrectly. Check the connection. Repair or replace if necessary.
- Code: C0630
- Description: DMA problem DMA transmission of compressed, decompressed, rotated, relocated or blanked-out image data does not complete within the specified period of time.
- Causes: Defective main PWB. DDR on the main PWB installed incorrectly.
- Remedy: Defective main PWB. Replace the main PWB and check for correct operation. DDR on the main PWB installed incorrectly. Check the connection. Repair or replace if necessary.
- Code: C0640
- Description: Hard disk drive problem The hard disk cannot be accessed.
- Causes: Poor contact in the connector terminals. Defective hard disk. Defective main PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC11 on the main PWB and the connector on the hard disk, and the continuity across the connector terminals. Repair or replace if necessary. Defective hard disk. Run U024 (HDD formatting) without turning the power off to initialize the hard disk. Replace the hard disk drive and check for correct operation if the problem is still detected after initialization. Defective main PWB. Replace the main PWB and check for correct operation.
- Code: C0820
- Description: Fax control PWB CG ROM checksum error (optional fax) A checksum error occurred with the CG ROM data of the fax control PWB.
- Causes: Defective fax software. Defective fax control PWB.
- Remedy: Defective fax software. Install the fax software. Defective fax control PWB. Replace the fax control PWB and verify the operation.
- Code: C0830
- Description: Fax control PWB flash program area checksum error (optional fax) A checksum error occurred with the program of the fax control PWB.
- Causes: Defective fax software. Defective fax control PWB.
- Remedy: Defective fax software. Install the fax software. Defective fax control PWB. Replace the fax control PWB and verify the operation.
- Code: C0840
- Description: Faults of RTC The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed.
- Causes: Defective main PWB. The battery is disconnected from the main PWB.
- Remedy: Defective main PWB. Replace the main PWB and check for correct operation. The battery is disconnected from the main PWB. Check visually and remedy if necessary.
- Code: C0860
- Description: Fax control PWB software switch checksum error (optional fax) A checksum error occurred with the software switch value of the fax control PWB.
- Causes: Defective fax software. Defective fax control PWB.
- Remedy: Defective fax software. Install the fax software. Defective fax control PWB. Replace the fax control PWB and verify the operation.
- Code: C0870
- Description: Fax control PWB to main PWB high capacity data transfer problem High-capacity data transfer between the fax control PWB and the scanner MIP PWB was not normally performed even if the data transfer was retried 10 times.
- Causes: Poor contact in the connector terminals. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC6 on the main PWB and the connector on the fax control PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective PWB. Replace the fax control PWB or main PWB and check for correct operation.
– Kyocera KMC3232 printer Error Codes and quick guide to troubleshooting:
- Code: C0880
- Description: Program archive problem (optional fax) When power is turned on, the compressed program in the Flash ROM on the fax control PWB was not successfully decompressed.
- Causes: Defective fax software. Defective fax control PWB.
- Remedy: Defective fax software. Install the fax software. Defective fax control PWB. Replace the fax control PWB and verify the operation.
- Code: C0890
- Description: Fax control PWB CG FONT archive problem (optional fax) When power is turned on, the compressed CG font in the Flash ROM on the fax control PWB was not successfully decompressed.
- Causes: Defective fax software. Defective fax control PWB.
- Remedy: Defective fax software. Install the fax software. Defective fax control PWB. Replace the fax control PWB and verify the operation.
- Code: C0920
- Description: Fax file system error The backup data is not retained for file system abnormality of flash memory of the fax control PWB.
- Causes: Defective fax control PWB.
- Remedy: Defective fax control PWB. Replace the fax control PWB and verify the operation.
- Code: C1010
- Description: Lift motor 1 error When cassette 1 is inserted, lift limit switch 1 does not turn on within 12 s of lift motor 1 turning on.
- Causes: Poor contact in the connector terminals. Broken gears or couplings of lift motor 1. Defective lift motor 1. Defective lift switch 1. Poor contact in the connector terminals. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector of lift motor 1 and the connector YC25 on the engine PWB, and the continuity across the connector terminals. Repair or replace if necessary. Broken gears or couplings of lift motor 1. Replace lift motor 1. Defective lift motor 1. Check for continuity across the coil. If none, replace lift motor 1. Defective lift switch 1. Check if YC9-12 on the feed PWB goes low when lift switch 1 is turned off. If not, replace lift switch 1. Poor contact in the connector terminals. Check the connection of connector of lift switch 1 and the connector YC9 on the feed PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective PWB. Replace the feed PWB or engine PWB and check for correct operation.
- Code: C1020
- Description: Lift motor 2 error When cassette 2 is inserted, lift limit switch 2 does not turn on within 12 s of lift motor 2 turning on.
- Causes: Poor contact in the connector terminals. Broken gears or couplings of lift motor 2. Defective lift motor 2. Defective lift switch 2. Poor contact in the connector terminals. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector of lift motor 2 and the connector YC25 on the engine PWB, and the continuity across the connector terminals. Repair or replace if necessary. Broken gears or couplings of lift motor 2. Replace lift motor 2. Defective lift motor 2. Check for continuity across the coil. If none, replace lift motor 2. Defective lift switch 2. Check if YC9-6 on the feed PWB goes low when lift switch 2 is turned off. If not, replace lift switch 2. Poor contact in the connector terminals. Check the connection of connector of lift switch 2 and the connector YC9 on the feed PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective PWB. Replace the feed PWB or engine PWB and check for correct operation.
- Code: C1030
- Description: Paper feeder lift motor 1 error (optional paper feeder) When optional cassette 3 is inserted, paper feeder lift switch 1 does not turn on within 12 s of paper feeder lift motor 1 turning on. The lift overcurrent protective monitor signal is detected above 500 ms during driving the motor. However, the first 1 s after paper feeder lift motor 1 is turned on is excluded from detection.
- Causes: Poor contact in the connector terminals. Broken gears or couplings of paper feeder lift motor 1. Defective paper feeder lift motor 1. Defective paper feeder lift switch 1.
- Remedy: Poor contact in the connector terminals. Check the connection of connector on the engine PWB and the connector on the paper feeder main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Broken gears or couplings of paper feeder lift motor 1. Replace paper feeder lift motor 1. Defective paper feeder lift motor 1. Check for continuity across the coil. If none, replace paper feeder lift motor 1. Defective paper feeder lift switch 1. Check if YC1-5 on the paper feeder main PWB goes low when paper feeder lift switch 1 is turned off. If not, replace paper feeder lift switch 1.
- Code: C1040
- Description: Paper feeder lift motor 2 error (optional paper feeder) When optional cassette 4 is inserted, paper feeder lift switch 2 does not turn on within 12 s of paper feeder lift motor 2 turning on. The lift overcurrent protective monitor signal is detected above 500 ms during driving the motor. However, the first 1 s after paper feeder lift motor 2 is turned on is excluded from detection.
- Causes: Poor contact in the connector terminals. Broken gears or couplings of paper feeder lift motor 2. Defective paper feeder lift motor 2. Defective paper feeder lift switch 2.
- Remedy: Poor contact in the connector terminals. Check the connection of connector on the engine PWB and the connector on the paper feeder main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Broken gears or couplings of paper feeder lift motor 2. Replace paper feeder lift motor 2. Defective paper feeder lift motor 2. Check for continuity across the coil. If none, replace paper feeder lift motor 2. Defective paper feeder lift switch 2. Check if YC1-7 on the paper feeder main PWB goes low when paper feeder lift switch 2 is turned off. If not, replace paper feeder lift switch 2.
- Code: C1100
- Description: Paper feeder lift motor 1 error (optional 3000-sheet paper feeder) A motor over-current signal is detected continuously for 1 s or longer.
- Causes: Poor contact in the connector terminals. Paper feeder lift motor 1 does not rotate correctly (the motor is overloaded).
- Remedy: Poor contact in the connector terminals. Check the connection of connector on the engine PWB and the connector on the paper feeder main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Paper feeder lift motor 1 does not rotate correctly (the motor is overloaded). Check the gears and remedy if necessary.
- Code: C1110
- Description: Paper feeder lift motor 2 error (optional 3000-sheet paper feeder) A motor over-current signal is detected continuously for 1 s or longer.
- Causes: Poor contact in the connector terminals. Paper feeder lift motor 2 does not rotate correctly (the motor is overloaded).
- Remedy: Poor contact in the connector terminals. Check the connection of connector on the engine PWB and the connector on the paper feeder main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Paper feeder lift motor 2 does not rotate correctly (the motor is overloaded). Check the gears and remedy if necessary.
- Code: C1120
- Description: Paper feeder left lift position problem (optional 3000-sheet paper feeder) Paper feeder switch 1 does not turn on within 30 s of paper feeder lift motor 2 turning on.
- Causes: Poor contact in the connector terminals. Defective paper feeder lift switch 1. Defective paper feeder lift motor 2. The paper feeder left lift does not rise properly.
- Remedy: Poor contact in the connector terminals. Check the connection of connector on the engine PWB and the connector on the paper feeder main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective paper feeder lift switch 1. Check if YC5-4 on the paper feeder main PWB goes low when paper feeder lift switch 1 is turned off. If not, replace paper feeder lift switch 1. Defective paper feeder lift motor 2. Check for continuity across the coil. If none, replace paper feeder lift motor 2. The paper feeder left lift does not rise properly. Check the gears and belts, and remedy if necessary.
- Code: C1130
- Description: Paper feeder right lift position problem (optional 3000-sheet paper feeder) Paper feeder switch 2 does not turn on within 30 s of paper feeder lift motor 1 turning on.
- Causes: Poor contact in the connector terminals. Defective paper feeder lift switch 2. Defective paper feeder lift motor 1. The paper feeder right lift does not rise properly.
- Remedy: Poor contact in the connector terminals. Check the connection of connector on the engine PWB and the connector on the paper feeder main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective paper feeder lift switch 2. Check if YC5-7 on the paper feeder main PWB goes low when paper feeder lift switch 2 is turned off. If not, replace paper feeder lift switch 2. Defective paper feeder lift motor 1. Check for continuity across the coil. If none, replace paper feeder lift motor 1. The paper feeder right lift does not rise properly. Check the gears and belts, and remedy if necessary.
- Code: C1900
- Description: Paper feeder EEPROM error (optional paper feeder) When writing the data, the write data and the read data is not continuously in agreement three times.
- Causes: Poor contact in the connector terminals. Defective engine PWB. Defective paper feeder.
- Remedy: Poor contact in the connector terminals. Check the connection of connector on the engine PWB and the connector on the paper feeder main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective engine PWB. Replace the engine PWB and check for correct operation. Defective paper feeder. Replace the paper feeder with another unit and check the operation. If the operation is normal, replace or repair optional paper feeder.
- Code: C1950
- Description: Transfer belt unit EEPROM error Read and write data does not match.
- Causes: Poor contact in the connector terminals. Defective transfer belt speed detection PWB (inner transfer belt unit).
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC28 on the engine PWB and the connector on the transfer belt unit, and the continuity across the connector terminals. Repair or replace if necessary. Defective transfer belt speed detection PWB (inner transfer belt unit). Replace the transfer belt unit.
- Code: C2101
- Description: Paper feed/developing motor BK error After the motor drive ON signal is output and 1 s elapses, the rated speed reach signal is not input continuously for 2 s.
- Causes: Poor contact in the connector terminals. Defective drive transmission system. Defective engine PWB. Defective paper feed/developing motor BK.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC8 on the engine PWB and the connector on the paper feed/developing motor BK, and the continuity across the connector terminals. Repair or replace if necessary. Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Defective engine PWB. Run maintenance item U030 and check if YC8-27 (remote signal) on the engine PWB goes low. If not, replace the engine PWB. Defective paper feed/developing motor BK. Run maintenance item U030 and check if the paper feed/developing motor BK operates when YC8-27 (remote signal) on the engine PWB goes low. If not, replace the paper feed/developing motor BK.
- Code: C2102
- Description: Developing motor CMY error After the motor drive ON signal is output and 1 s elapses, the rated speed reach signal is not input continuously for 2 s.
- Causes: Poor contact in the connector terminals. Defective drive transmission system. Defective engine PWB. Defective developing motor CMY.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC26 on the engine PWB and the connector on the developing motor CMY, and the continuity across the connector terminals. Repair or replace if necessary. Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Defective engine PWB. Run maintenance item U030 and check if YC26-13 (remote signal) on the engine PWB goes low. If not, replace the engine PWB. Defective developing motor CMY. Run maintenance item U030 and check if the developing motor CMY operates when YC26-13 (remote signal) on the engine PWB goes low. If not, replace the developing motor CMY.
- Code: C2201
- Description: Drum motor BK error After the motor drive ON signal is output and 1 s elapses, the rated speed reach signal is not input continuously for 2 s.
- Causes: Poor contact in the connector terminals. Defective drum motor BK. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC1 on the motor relay PWB and the connector on the drum motor BK, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor BK. Replace the drum motor BK. Defective PWB. Replace the motor relay PWB or engine PWB and check for correct operation.
- Code: C2202
- Description: Drum motor C error After the motor drive ON signal is output and 1 s elapses, the rated speed reach signal is not input continuously for 2 s.
- Causes: Poor contact in the connector terminals. Defective drum motor C. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC1 on the motor relay PWB and the connector on the drum motor C, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor C. Replace the drum motor C. Defective PWB. Replace the motor relay PWB or engine PWB and check for correct operation.
- Code: C2203
- Description: Drum motor M error After the motor drive ON signal is output and 1 s elapses, the rated speed reach signal is not input continuously for 2 s.
- Causes: Poor contact in the connector terminals. Defective drum motor M. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC1 on the motor relay PWB and the connector on the drum motor M, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor M. Replace the drum motor M. Defective PWB. Replace the motor relay PWB or engine PWB and check for correct operation.
- Code: C2204
- Description: Drum motor Y error After the motor drive ON signal is output and 1 s elapses, the rated speed reach signal is not input continuously for 2 s.
- Causes: Poor contact in the connector terminals. Defective drum motor Y. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC1 on the motor relay PWB and the connector on the drum motor Y, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor Y. Replace the drum motor Y. Defective PWB. Replace the motor relay PWB or engine PWB and check for correct operation.
- Code: C2300
- Description: Fuser motor error After the motor drive ON signal is output and 1 s elapses, the rated speed reach signal is not input continuously for 2 s.
- Causes: Poor contact in the connector terminals. Defective drive transmission system. Defective engine PWB. Defective fuser motor.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC27 on the engine PWB and the connector on the fuser motor, and the continuity across the connector terminals. Repair or replace if necessary. Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Defective engine PWB. Run maintenance item U030 and check if YC27-A10 (remote signal) on the engine PWB goes low. If not, replace the engine PWB. Defective fuser motor. Run maintenance item U030 and check if the fuser motor operates when YC27-A10 (remote signal) on the engine PWB goes low. If not, replace the fuser motor.
- Code: C2400
- Description: Eject motor error After the motor drive ON signal is output and 1 s elapses, the rated speed reach signal is not input continuously for 2 s.
- Causes: Poor contact in the connector terminals. Defective drive transmission system. Defective engine PWB. Defective eject motor.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC27 on the engine PWB and the connector on the eject motor, and the continuity across the connector terminals. Repair or replace if necessary. Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Defective engine PWB. Run maintenance item U030 and check if YC27-B4 (remote signal) on the engine PWB goes low. If not, replace the engine PWB. Defective eject motor. Run maintenance item U030 and check if the eject motor operates when YC27-B4 (remote signal) on the engine PWB goes low. If not, replace the eject motor.
- Code: C2500
- Description: MP motor error After the motor drive ON signal is output and 1 s elapses, the rated speed reach signal is not input continuously for 2 s.
- Causes: Poor contact in the connector terminals. Defective drive transmission system. Defective engine PWB. Defective MP motor.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC26 on the engine PWB and the connector on the MP motor, and the continuity across the connector terminals. Repair or replace if necessary. Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Defective engine PWB. Run maintenance item U030 and check if YC26-5 (remote signal) on the engine PWB goes low. If not, replace the engine PWB. Defective MP motor. Run maintenance item U030 and check if the MP motor operates when YC26-5 (remote signal) on the engine PWB goes low. If not, replace the MP motor.
- Code: C2600
- Description: Paper feeder paper conveying motor error (optional paper feeder) The lock signal of the motor is detected above 450 ms.
- Causes: Poor contact in the connector terminals. Defective drive transmission system. Defective PWB. Defective paper feeder paper conveying motor.
- Remedy: Poor contact in the connector terminals. Check the connection of connector on the engine PWB and the connector on the paper feeder main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Defective PWB. Replace the paper feeder main PWB or engine PWB and check for correct operation. Defective paper feeder paper conveying motor. Replace the paper feeder paper conveying motor.
- Code: C2810
- Description: Waste toner motor error The rated speed achievement signal won’t turn to L in 5 s since the motor is activated. The rated speed achievement signal turns to H every other 5 s after the machine is stabilized.
- Causes: Poor contact in the connector terminals. Defective drive transmission system. Defective waste toner motor. Defective engine PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC30 on the engine PWB and the connector on the waste toner motor, and the continuity across the connector terminals. Repair or replace if necessary. Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Defective waste toner motor. Replace the waste toner motor. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C3100
- Description: Scanner carriage problem The home position is not correct when the power is turned on or at the start of copying using the table.
- Causes: Defective scanner PWB. Defective scanner home position switch. Defective scanner motor. Poor contact in the connector terminals. The mirror frame, exposure lamp, or scanner wire is defective.
- Remedy: Defective scanner PWB. Replace the scanner PWB and check for correct operation. Defective scanner home position switch. Replace the scanner home position switch. Defective scanner motor. Replace the scanner motor. Poor contact in the connector terminals. Check the connection of connector YC4 on the scanner PWB and the connector on the scanner home position switch, and the connection of connector YC9 on the scanner PWB and the connector on the scanner motor and the continuity across the connector terminals. Repair or replace if necessary. The mirror frame, exposure lamp, or scanner wire is defective. Check if the mirror flames and exposure lamp are on the rail. And check the scanner wire winds correctly.
- Code: C3200
- Description: Exposure lamp problem The exposure lamp is not turned on when starting the copy.
- Causes: Poor contact in the connector terminals. Defective scanner PWB. Defective CCD PWB. Defective exposure lamp or inverter PWB. Incorrect shading position.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC6 on the scanner PWB and the connector on the inverter PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective scanner PWB. Replace the scanner PWB and check for correct operation. Defective CCD PWB. Replace the CCD PWB and check for correct operation. Defective exposure lamp or inverter PWB. Replace the exposure lamp or inverter PWB. Incorrect shading position. Adjust the position of the contact glass (shading plate). If the problem still occurs, replace the scanner home position switch.
- Code: C3300
- Description: Optical system (AGC) problem After AGC, correct input is not obtained at CCD.
- Causes: Poor contact in the connector terminals. Defective exposure lamp. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC6 on the scanner PWB and the connector on the inverter PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective exposure lamp. Replace the exposure lamp or inverter PWB. Defective PWB. Replace the SHD PWB or CCD PWB and check for correct operation.
- Code: C3500
- Description: Communication error between scanner and SHD An error code is detected.
- Causes: Poor contact in the connector terminals. Defective PWB
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC3 on the scanner PWB and the connector YC4 on the SHD PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective PWB. Replace the SHD PWB or CCD PWB and check for correct operation.
- Code: C3900
- Description: Backup memory read/write problem (scanner PWB) Read and write data does not match.
- Causes: Defective backup RAM or scanner PWB.
- Remedy: Defective backup RAM or scanner PWB. Replace the scanner PWB and check for correct operation.
- Code: C3910
- Description: Backup memory data problem (scanner PWB) Data in the specified area of the backup memory does not match the specified values.
- Causes: Problem with the backup memory data. Defective scanner PWB.
- Remedy: Problem with the backup memory data. Run maintenance item U020 to initialize the backup memory data. Defective scanner PWB. If the C3910 is displayed after initializing the backup memory, replace the scanner PWB and check for correct operation.
- Code: C4000
- Description: Polygon motor synchronization problem The rated speed achievement signal won’t turn to L in 20 s since the polygon motor is activated.
- Causes: Poor contact in the connector terminals. Defective polygon motor. Defective engine PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC16 on the engine PWB and laser scanner unit, and the continuity across the connector terminals. Repair or replace if necessary. Defective polygon motor. Replace the laser scanner unit. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C4010
- Description: Polygon motor steady-state problem The rated speed achievement signal turns to H every other 5 s after the polygon motor is stabilized.
- Causes: Poor contact in the connector terminals. Defective polygon motor. Defective engine PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC16 on the engine PWB and laser scanner unit, and the continuity across the connector terminals. Repair or replace if necessary. Defective polygon motor. Replace the laser scanner unit. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C4100
- Description: BD initialization problem When power is turned on, ASIC of engine PWB detects a BD error for 200 ms.
- Causes: Poor contact in the connector terminals. Defective APC PWB BK (inner laser scanner unit) Defective engine PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC16 on the engine PWB and laser scanner unit, and the continuity across the connector terminals. Repair or replace if necessary. Defective APC PWB BK (inner laser scanner unit) Replace the laser scanner unit. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C4200
- Description: BD steady-state problem ASIC of the engine PWB detects a BD error for 200 ms after the polygon motor rotation has been stabilized.
- Causes: Poor contact in the connector terminals. Defective laser scanner unit. Defective engine PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC16 on the engine PWB and laser scanner unit, and the continuity across the connector terminals. Repair or replace if necessary. Defective laser scanner unit. Replace the laser scanner unit. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C5101
- Description: Main high-voltage BK error Abnormality of charger roller BK is detected when Vpp adjustment.
- Causes: Installation defectiveness on charger roller unit BK. Defective charger roller unit BK.
- Remedy: Installation defectiveness on charger roller unit BK. Check the mounting state of the charger roller unit BK. If any problem is found, repair or replace the unit. Defective charger roller unit BK. Replace the charger roller unit BK.
- Code: C5102
- Description: Main high-voltage C error Abnormality of charger roller C is detected when Vpp adjustment.
- Causes: Installation defectiveness on charger roller unit C. Defective charger roller unit C.
- Remedy: Installation defectiveness on charger roller unit C. Check the mounting state of the charger roller unit C. If any problem is found, repair or replace the unit. Defective charger roller unit C. Replace the charger roller unit C.
- Code: C5103
- Description: Main high-voltage M error Abnormality of charger roller M is detected when Vpp adjustment.
- Causes: Installation defectiveness on charger roller unit M. Defective charger roller unit M.
- Remedy: Installation defectiveness on charger roller unit M. Check the mounting state of the charger roller unit M. If any problem is found, repair or replace the unit. Defective charger roller unit M. Replace the charger roller unit M.
- Code: C5104
- Description: Main high-voltage Y error Abnormality of charger roller Y is detected when Vpp adjustment.
- Causes: Installation defectiveness on charger roller unit Y. Defective charger roller unit Y.
- Remedy: Installation defectiveness on charger roller unit Y. Check the mounting state of the charger roller unit Y. If any problem is found, repair or replace the unit. Defective charger roller unit Y. Replace the charger roller unit Y.
- Code: C5301
- Description: Cleaning lamp BK break error After the cleaning lamp BK ON signal is turned on, the cleaning lamp BK break signal is detected continuously 5 times for 10 ms.
- Causes: Poor contact in the connector terminals. Defective cleaning lamp BK. Defective engine PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC18 on the engine PWB and the connector on the drum unit BK, and the continuity across the connector terminals. Repair or replace if necessary. Defective cleaning lamp BK. Replace the drum unit BK. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C5302
- Description: Cleaning lamp C break error After the cleaning lamp C ON signal is turned on, the cleaning lamp C break signal is detected continuously 5 times for 10 ms.
- Causes: Poor contact in the connector terminals. Defective cleaning lamp C. Defective engine PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC17 on the engine PWB and the connector on the drum unit C, and the continuity across the connector terminals. Repair or replace if necessary. Defective cleaning lamp C. Replace the drum unit C. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C5303
- Description: Cleaning lamp M break error After the cleaning lamp M ON signal is turned on, the cleaning lamp M break signal is detected continuously 5 times for 10 ms.
- Causes: Poor contact in the connector terminals. Defective cleaning lamp M. Defective engine PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC17 on the engine PWB and the connector on the drum unit M, and the continuity across the connector terminals. Repair or replace if necessary. Defective cleaning lamp M. Replace the drum unit M. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C5304
- Description: Cleaning lamp Y break error After the cleaning lamp Y ON signal is turned on, the cleaning lamp Y break signal is detected continuously 5 times for 10 ms.
- Causes: Poor contact in the connector terminals. Defective cleaning lamp Y. Defective engine PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC18 on the engine PWB and the connector on the drum unit Y, and the continuity across the connector terminals. Repair or replace if necessary. Defective cleaning lamp Y. Replace the drum unit Y. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C6000
- Description: Fuser thermistor 1/3 break error Fuser thermistor 1 detected 40 C/104 F or less during warming up. 40 C/104 F or less is detected between 10 s of continuation during worming up. Fuser thermistor 3 detected 40 C/104 F or less during warming up.
- Causes: Defective fuser heater 1/2. Defective fuser thermostat 1. Installation defectiveness on fuser thermistor 1/2. Defective PWB.
- Remedy: Defective fuser heater 1/2. Check for continuity across each heater. If none, replace the fuser unit. Defective fuser thermostat 1. Check for continuity across thermostat. If none, remove the cause and replace the fuser unit. Installation defectiveness on fuser thermistor 1/2. Measure the resistance. If it is ∞Ω, replace the fuser unit. Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.
- Code: C6010
- Description: Abnormally high fuser thermistor temperature The fuser Abnormally high signal is detected for 60 s or more.
- Causes: Defective PWB.
- Remedy: Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.
- Code: C6020
- Description: Abnormally high fuser thermistor 1/3 temperature The fuser temperature exceeds 240 C/ 464 F.
- Causes: Defective PWB. Installation defectiveness on fuser thermistor 1/3.
- Remedy: Defective PWB. Replace the power source PWB or engine PWB and check for correct operation. Installation defectiveness on fuser thermistor 1/3. Measure the resistance. If it is ∞Ω, replace the fuser unit.
- Code: C6030
- Description: Fuser thermistor 1/3 break error Fuser thermistor 1 detected 40 C/104 F or less during warming up. 40 C/104 F or less is detected between 10 s of continuation during worming up. Fuser thermistor 3 detected 40 C/104 F or less during warming up.
- Causes: Defective fuser heater 1/2. Installation defectiveness on fuser thermistor 1/3. Defective PWB.
- Remedy: Defective fuser heater 1/2. Check for continuity across each heater. If none, replace the fuser unit. Installation defectiveness on fuser thermistor 1/3. Measure the resistance. If it is ∞Ω, replace the fuser unit. Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.
- Code: C6050
- Description: Abnormally low fuser thermistor 3 temperature During copying, the temperature at the heat roller lower than 100 C/212 F is detected continuously for 1 s.
- Causes: Defective fuser heater 1/2. Defective PWB.
- Remedy: Defective fuser heater 1/2. Replace the fuser unit. Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.
- Code: C6100
- Description: Fuser heater 3 break Fuser thermistor 2 detected less than 100 C/212 F for 120 s during driving. Fuser thermistor 2 deduced less than 150 C/302 F for 300 s during driving. Fuser thermistor 2 deduced less than 100 C/212 F for 5 s during driving.
- Causes: Defective fuser heater 3. Defective fuser thermostat 2. Installation defectiveness on fuser thermistor 2. Defective PWB.
- Remedy: Defective fuser heater 3. Check for continuity across each heater. If none, replace the fuser unit. Defective fuser thermostat 2. Check for continuity across thermostat. If none, remove the cause and replace the fuser unit. Installation defectiveness on fuser thermistor 2. Measure the resistance. If it is ∞Ω, replace the fuser unit. Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.
- Code: C6120
- Description: Abnormally high fuser thermistor 2 temperature The fuser temperature exceeds 190 C/ 374 F.
- Causes: Installation defectiveness on fuser thermistor 2. Defective PWB.
- Remedy: Installation defectiveness on fuser thermistor 2. Measure the resistance. If it is ∞Ω, replace the fuser unit. Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.
- Code: C6130
- Description: Fuser thermistor 2 break error Fuser thermistor 2 detected less than 40 C/104 F during driving. When the difference of temperature of fuser thermistor 1 and 3 becomes 100 C/212 F or more.
- Causes: Installation defectiveness on fuser thermistor 2. Defective fuser heater 3. Defective PWB.
- Remedy: Installation defectiveness on fuser thermistor 2. Measure the resistance. If it is ∞Ω, replace the fuser unit. Defective fuser heater 3. Check for continuity across each heater. If none, replace the fuser unit. Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.
- Code: C6400
- Description: Zero-cross signal error While fuser heater ON/OFF control is performed, the zero-cross signal is not input within 3 s.
- Causes: Defective PWB.
- Remedy: Defective PWB. Replace the engine PWB or power source PWB and check for correct operation.
- Code: C7000
- Description: Toner motor problem The rated speed achievement signal won’t turn to L in 5 s since the motor is activated. The rated speed achievement signal turns to H every other 5 s after the machine is stabilized.
- Causes: Poor contact in the connector terminals. Broken the gear. Defective toner motor M/C/Y/BK. Defective engine PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC30 on the engine PWB and the connector on the toner motor, and the continuity across the connector terminals. Repair or replace if necessary. Broken the gear. Check visually and replace the gear if necessary. Defective toner motor M/C/Y/BK. Run maintenance item U135 and check if the toner motor operates. If not, replace the toner motor. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C7101
- Description: Toner sensor BK problem Sensor output value of 78 or less or 944 or more continued for 3 s.
- Causes: Defective developing unit BK. Defective engine PWB.
- Remedy: Defective developing unit BK. Replace the developing unit BK. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C7102
- Description: Toner sensor C problem Sensor output value of 78 or less or 944 or more continued for 3 s.
- Causes: Defective developing unit C. Defective engine PWB.
- Remedy: Defective developing unit C. Replace the developing unit C. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C7103
- Description: Toner sensor M problem Sensor output value of 78 or less or 944 or more continued for 3 s.
- Causes: Defective developing unit M. Defective engine PWB.
- Remedy: Defective developing unit M. Replace the developing unit M. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C7104
- Description: Toner sensor Y problem Sensor output value of 78 or less or 944 or more continued for 3 s.
- Causes: Defective developing unit Y. Defective engine PWB.
- Remedy: Defective developing unit Y. Replace the developing unit Y. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C7200
- Description: Broken internal thermistor wire An abnormal value is detected in the input data to inner temperature sensor 1.
- Causes: Poor contact in the connector terminals. Defective laser scanner unit. Defective engine PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC16 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective laser scanner unit. Replace the laser scanner unit. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C7210
- Description: Short-circuited internal thermistor An abnormal value is detected in the input data to inner temperature sensor 1.
- Causes: Poor contact in the connector terminals. Defective laser scanner unit. Defective engine PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC16 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective laser scanner unit. Replace the laser scanner unit. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C7220
- Description: Broken internal thermistor 2 wire An abnormal value is detected in the input data to inner temperature sensor 2.
- Causes: Poor contact in the connector terminals. Defective engine PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC28 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C7230
- Description: Short-circuited internal thermistor 2 An abnormal value is detected in the input data to inner temperature sensor 2.
- Causes: Poor contact in the connector terminals. Defective engine PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC28 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C7240
- Description: Broken internal thermistor 3 wire An abnormal value is detected in the input data to inner temperature sensor 3.
- Causes: Poor contact in the connector terminals. Defective engine PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC8 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C7250
- Description: Short-circuited internal thermistor 3 An abnormal value is detected in the input data to inner temperature sensor 3.
- Causes: Poor contact in the connector terminals. Defective engine PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC8 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C7401
- Description: Developing unit BK type mismatch problem Absence of the developing unit BK is detected.
- Causes: Developing unit connector inserted incorrectly. Different type of the developing unit is installed.
- Remedy: Developing unit connector inserted incorrectly. Reinsert the developing unit connector if necessary. Different type of the developing unit is installed. Install the correct developing unit.
- Code: C7402
- Description: Developing unit C type mismatch problem Absence of the developing unit C is detected.
- Causes: Developing unit connector inserted incorrectly. Different type of the developing unit is installed.
- Remedy: Developing unit connector inserted incorrectly. Reinsert the developing unit connector if necessary. Different type of the developing unit is installed. Install the correct developing unit.
- Code: C7403
- Description: Developing unit M type mismatch problem Absence of the developing unit M is detected.
- Causes: Developing unit connector inserted incorrectly. Different type of the developing unit is installed.
- Remedy: Developing unit connector inserted incorrectly. Reinsert the developing unit connector if necessary. Different type of the developing unit is installed. Install the correct developing unit.
- Code: C7404
- Description: Developing unit Y type mismatch problem Absence of the developing unit Y is detected.
- Causes: Developing unit connector inserted incorrectly. Different type of the developing unit is installed.
- Remedy: Developing unit connector inserted incorrectly. Reinsert the developing unit connector if necessary. Different type of the developing unit is installed. Install the correct developing unit.
- Code: C7411
- Description: Drum unit BK type mismatch problem Absence of the drum unit BK is detected.
- Causes: Drum unit connector inserted incorrectly. Different type of the drum unit is installed.
- Remedy: Drum unit connector inserted incorrectly. Reinsert the drum unit connector if necessary. Different type of the drum unit is installed. Install the correct drum unit.
- Code: C7412
- Description: Drum unit C type mismatch problem Absence of the drum unit C is detected.
- Causes: Drum unit connector inserted incorrectly. Different type of the drum unit is installed.
- Remedy: Drum unit connector inserted incorrectly. Reinsert the drum unit connector if necessary. Different type of the drum unit is installed. Install the correct drum unit.
- Code: C7413
- Description: Drum unit M type mismatch problem Absence of the drum unit M is detected.
- Causes: Drum unit connector inserted incorrectly. Different type of the drum unit is installed.
- Remedy: Drum unit connector inserted incorrectly. Reinsert the drum unit connector if necessary. Different type of the drum unit is installed. Install the correct drum unit.
- Code: C7414
- Description: Drum unit Y type mismatch problem Absence of the drum unit Y is detected.
- Causes: Drum unit connector inserted incorrectly. Different type of the drum unit is installed.
- Remedy: Drum unit connector inserted incorrectly. Reinsert the drum unit connector if necessary. Different type of the drum unit is installed. Install the correct drum unit.
- Code: C7420
- Description: Transfer belt unit type mismatch problem Absence of the transfer belt unit is detected.
- Causes: Transfer belt unit connector inserted incorrectly. Different type of the transfer belt unit is installed.
- Remedy: Transfer belt unit connector inserted incorrectly. Reinsert the transfer belt unit connector if necessary. Different type of the transfer belt unit is installed. Install the correct transfer belt unit.
- Code: C7800
- Description: Broken external thermistor wire An abnormal value is detected in the input data to the outer temperature sensor.
- Causes: Poor contact in the connector terminals. Defective engine PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC13 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C7810
- Description: Short-circuited external thermistor An abnormal value is detected in the input data to the outer temperature sensor.
- Causes: Poor contact in the connector terminals. Defective engine PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC13 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: C7901
- Description: Drum BK EEPROM error Reading from or writing to EEPROM cannot be performed.
- Causes: Poor contact in the connector terminals. Defective drum PWB BK.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC18 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective drum PWB BK. Replace the drum unit BK.
- Code: C7902
- Description: Drum C EEPROM error Reading from or writing to EEPROM cannot be performed.
- Causes: Poor contact in the connector terminals. Defective drum PWB C.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC17 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective drum PWB C. Replace the drum unit C.
- Code: C7903
- Description: Drum M EEPROM error Reading from or writing to EEPROM cannot be performed.
- Causes: Poor contact in the connector terminals. Defective drum PWB M.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC17 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective drum PWB M. Replace the drum unit M.
- Code: C7904
- Description: Drum Y EEPROM error Reading from or writing to EEPROM cannot be performed.
- Causes: Poor contact in the connector terminals. Defective drum PWB Y.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC18 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective drum PWB Y. Replace the drum unit Y.
- Code: C7911
- Description: Developing unit BK EEPROM error Reading from or writing to EEPROM cannot be performed.
- Causes: Poor contact in the connector terminals. Defective developing PWB BK.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC18 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective developing PWB BK. Replace the developing unit BK.
- Code: C7912
- Description: Developing unit C EEPROM error Reading from or writing to EEPROM cannot be performed.
- Causes: Poor contact in the connector terminals. Defective developing PWB C.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC17 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective developing PWB C. Replace the developing unit C.
- Code: C7913
- Description: Developing unit M EEPROM error Reading from or writing to EEPROM cannot be performed.
- Causes: Poor contact in the connector terminals. Defective developing PWB M.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC17 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective developing PWB M. Replace the developing unit M.
- Code: C7914
- Description: Developing unit Y EEPROM error Reading from or writing to EEPROM cannot be performed.
- Causes: Poor contact in the connector terminals. Defective developing PWB Y.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC18 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective developing PWB Y. Replace the developing unit Y.
- Code: C8020
- Description: Punch motor problem (optional 3000 sheet document finisher) The LOCK signal of the punch motor is detected for more than 500 ms while the punch motor is operating.
- Causes: Poor contact in the connector terminals. Defective punch motor. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector on the punch PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective punch motor. Replace the punch motor. Defective PWB. Replace the punch PWB or finisher main PWB and check for correct operation.
- Code: C8030
- Description: Tray upper limit detection problem (optional document finisher) When the tray elevation motor raises a tray, the ON status of the tray upper limit sensor is detected.
- Causes: The tray upper limit sensor/push paper sensor/surface view sensor connector makes poor contact. Defective tray upper limit sensor/ push paper sensor/ surface view sensor. Defective finisher main PWB.
- Remedy: The tray upper limit sensor/push paper sensor/surface view sensor connector makes poor contact. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Defective tray upper limit sensor/ push paper sensor/ surface view sensor. Replace the sensor. Defective finisher main PWB. Replace the finisher main PWB and check for correct operation.
- Code: C8050
- Description: Paper conveying belt motor 1 problem (optional 3000-sheet document finisher) Paper conveying belt home position sensor 1 does not turn off within 1.5 s. Paper conveying belt home position sensor 1 does not turn on within 2.5 s. Jam 88 is indicated.
- Causes: Poor contact in the connector terminals. Defective paper conveying belt home position sensor 1. Defective paper conveying belt motor 1. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC2 on the internal tray PWB and the connector on paper conveying belt motor 1, and the continuity across the connector terminals. Repair or replace if necessary. Defective paper conveying belt home position sensor 1. Replace paper conveying belt home position sensor 1. Defective paper conveying belt motor 1. Replace paper conveying belt motor 1. Defective PWB. Replace the internal tray PWB or finisher main PWB and check for correct operation.
- Code: C8060
- Description: Paper conveying belt motor 2 problem (optional 3000-sheet document finisher) Paper conveying belt home position sensor 2 does not turn off within 1.5 s. Paper conveying belt home position sensor 2 does not turn on within 1.5 s.
- Causes: Poor contact in the connector terminals. Defective paper conveying belt home position sensor 2. Defective paper conveying belt motor 2. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC6 on the internal tray PWB and the connector on paper conveying belt motor 2, and the continuity across the connector terminals. Repair or replace if necessary. Defective paper conveying belt home position sensor 2. Replace paper conveying belt home position sensor 2. Defective paper conveying belt motor 2. Replace paper conveying belt motor 2. Defective PWB. Replace the internal tray PWB or finisher main PWB and check for correct operation.
- Code: C8070
- Description: Internal tray communication error (optional 3000-sheet document finisher) Communication with the internal tray is not possible although the connection is detected.
- Causes: Poor contact in the connector terminals. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC6 on the finisher main PWB and the connector YC1 on the internal tray PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective PWB. Replace the internal tray PWB or finisher main PWB and check for correct operation.
- Code: C8140
- Description: Main tray problem (optional 3000- sheet document finisher) The main tray is not detected by the main tray upper limit detection sensor or the main tray paper upper surface detection sensor within 20s since the tray has started ascending. The main tray upper limit detection sensor or the main tray paper upper surface detection sensor is not detected to be turned off in 20 s after the main tray has descended. The main tray low limit detection sensor is not detected to be turned on in 20 s after the main tray has descended. During main tray ascent, the main tray upper limit detection sensor or the main tray paper upper surface detection sensor stays on for more than 2 s.
- Causes: Poor contact in the connector terminals Defective main tray motor .Defective main tray upper limit detection sensor/main tray paper upper surface detection sensor/main tray lower limit detection sensor. Defective finisher main PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC6 on the finisher main PWB and the connector on the main tray motor, and the continuity across the connector terminals. Repair or replace if necessary. Defective main tray motor. Replace the main tray motor. Defective main tray upper limit detection sensor/main tray paper upper surface detection sensor/main tray lower limit detection sensor. Replace the sensor. Defective finisher main PWB. Replace the finisher main PWB and check for correct operation.
- Code: C8140
- Description: Tray elevation motor problem (optional document finisher) The tray low limit sensor, paper retaining sensor or paper surface sensor cannot be detected to be on within 10 s since the tray elevation motor is activated.
- Causes: The tray elevation motor connector makes poor contact. The tray elevation motor malfunctions. The tray lower limit sensor/push paper sensor/surface view sensor connector makes poor contact. Defective tray lower limit sensor/ push paper sensor/ surface view sensor. Defective finisher main PWB.
- Remedy: The tray elevation motor connector makes poor contact. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. The tray elevation motor malfunctions. Replace the tray elevation motor. The tray lower limit sensor/push paper sensor/surface view sensor connector makes poor contact. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Defective tray lower limit sensor/ push paper sensor/ surface view sensor. Replace the sensor. Defective finisher main PWB. Replace the finisher main PWB and check for correct operation.
- Code: C8170
- Description: Side registration motor 1 problem (optional 3000-sheet document finisher) When operation returned to a home position is performed at the time of initial operation and a home position is not detected even if 3 s passed. Jam 88 is indicated.
- Causes: Poor contact in the connector terminals. Defective side registration motor 1. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC2 on the internal tray PWB and the connector on side registration motor 1, and the continuity across the connector terminals. Repair or replace if necessary. Defective side registration motor 1. Replace side registration motor 1. Defective PWB. Replace the internal tray PWB or finisher main PWB and check for correct operation.
- Code: C8170
- Description: Adjustment motor problem (optional document finisher) The registration home position sensor cannot be detected to be on or off within 125 ms since the registration motor is activated after registration has started. The registration home position sensor cannot be detected to be on within 710 ms since the registration motor is activated after registration has ceased.
- Causes: The adjustment motor connector makes poor contact Defective adjustment motor. The adjustment home position sensor connector makes poor contact. Defective adjustment home position sensor. Defective finisher main PWB.
- Remedy: The adjustment motor connector makes poor contact. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Defective adjustment motor. Replace adjustment motor. The adjustment home position sensor connector makes poor contact. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Defective adjustment home position sensor. Replace the adjustment home position sensor. Defective finisher main PWB. Replace the finisher main PWB and check for correct operation.
- Code: C8180
- Description: Side registration motor 2 problem (optional 3000-sheet document finisher) When operation returned to a home position is performed at the time of initial operation and a home position is not detected even if 3 s passed. Jam 88 is indicated.
- Causes: Poor contact in the connector terminals. Defective side registration motor 2. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC8 on the internal tray PWB and the connector of side registration motor 2, and the continuity across the connector terminals. Repair or replace if necessary. Defective side registration motor 2. Replace side registration motor 2. Defective PWB. Replace the internal tray PWB or finisher main PWB and check for correct operation.
- Code: C8210
- Description: Stapler shift motor 1 error (optional 3000-sheet document finisher) When operation returned to a home position is performed at the time of initial operation and a home position is not detected even if 1.5 s passed.
- Causes: Poor contact in the connector terminals. Defective stapler shift motor 1. Defective finisher main PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC9 on the finisher main PWB and the connector of stapler shift motor 1, and the continuity across the connector terminals. Repair or replace if necessary. Defective stapler shift motor 1. Replace stapler shift motor 1. Defective finisher main PWB. Replace the finisher main PWB and check for correct operation.
- Code: C8210
- Description: Stapler problem (optional document finisher) When the stapler motor is driving, the ON status of the stapler home position sensor cannot be detected even if 1 s passed.
- Causes: The stapler connector makes poor contact. The stapler is blocked with a staple. The stapler is broken. Defective finisher main PWB.
- Remedy: The stapler connector makes poor contact. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. The stapler is blocked with a staple. Remove the stapler cartridge, and check the cartridge and the stapling section of the stapler. The stapler is broken. Replace the stapler and check for correct operation. Defective finisher main PWB. Replace the finisher main PWB and check for correct operation.
- Code: C8220
- Description: Stapler shift motor 2 error (optional 3000-sheet document finisher) When operation returned to a home position is performed at the time of initial operation and a home position is not detected even if 3.5 s passed.
- Causes: Poor contact in the connector terminals. Defective stapler shift motor 2. Defective finisher main PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC10 on the finisher main PWB and the connector of stapler shift motor 2, and the continuity across the connector terminals. Repair or replace if necessary. Defective stapler shift motor 2. Replace stapler shift motor 2. Defective finisher main PWB. Replace the finisher main PWB and check for correct operation.
- Code: C8230
- Description: Stapler motor problem (optional 3000sheet document finisher) Jam 82 is indicated.
- Causes: Poor contact in the connector terminals. Defective stapler motor. Defective finisher main PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC10 on the finisher main PWB and the connector of stapler motor, and the continuity across the connector terminals. Repair or replace if necessary. Defective stapler motor. Replace the stapler motor. Defective finisher main PWB. Replace the finisher main PWB and check for correct operation.
- Code: C8300
- Description: Centerfold unit communication error (optional centerfold unit of 3000-sheet document finisher) Communication with the centerfold unit is not possible although the connection is detected.
- Causes: Poor contact in the connector terminals. Defective centerfold set switch. Defective finisher main PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC22 on the finisher main PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective centerfold set switch. Replace the centerfold set switch. Defective finisher main PWB. Replace the finisher main PWB and check for correct operation.
- Code: C8310
- Description: Centerfold side registration motor 1 problem (optional centerfold unit of 3000-sheet document finisher) The home position is not detected when initial operation even if 1 s passed.
- Causes: Poor contact in the connector terminals. Defective centerfold side registration motor 1. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC6 on the centerfold main PWB and the connector of centerfold side registration motor 1, and the continuity across the connector terminals. Repair or replace if necessary. Defective centerfold side registration motor 1. Replace centerfold side registration motor 1. Defective PWB. Replace the centerfold main PWB or finisher main PWB and check for correct operation.
- Code: C8320
- Description: Centerfold paper conveying belt motor problem (optional centerfold unit of 3000-sheet document finisher) The home position is not detected when initial operation even if 2.5 s passed.
- Causes: Poor contact in the connector terminals. Defective centerfold paper conveying belt motor 1/2. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC6, YC7 on the centerfold main PWB and the connector of centerfold paper conveying belt motor 1/2, and the continuity across the connector terminals. Repair or replace if necessary. Defective centerfold paper conveying belt motor 1/2. Replace centerfold paper conveying belt motor 1/2. Defective PWB. Replace the centerfold main PWB or finisher main PWB and check for correct operation.
- Code: C8330
- Description: Blade motor problem (optional centerfold unit of 3000-sheet document finisher) The home position is not detected when initial operation even if 1.5 s passed.
- Causes: Poor contact in the connector terminals. Defective blade motor. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC8 on the centerfold main PWB and the connector of the blade motor, and the continuity across the connector terminals. Repair or replace if necessary. Defective blade motor. Replace the blade motor. Defective PWB. Replace the centerfold main PWB or finisher main PWB and check for correct operation.
- Code: C8340
- Description: Centerfold staple motor problem (optional centerfold unit of 3000-sheet document finisher) Jam89 is indicated.
- Causes: Poor contact in the connector terminals. Defective centerfold staple motor. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC9 on the centerfold main PWB and the connector of the centerfold staple motor, and the continuity across the connector terminals. Repair or replace if necessary. Defective centerfold staple motor. Replace the centerfold staple motor. Defective PWB. Replace the centerfold main PWB or finisher main PWB and check for correct operation.
- Code: C8350
- Description: Centerfold side registration motor 2 problem (optional centerfold unit of 3000-sheet document finisher) The home position is not detected when initial operation even if 1 s passed.
- Causes: Poor contact in the connector terminals. Defective centerfold side registration motor 2. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC7 on the centerfold main PWB and the connector of centerfold side registration motor 2, and the continuity across the connector terminals. Repair or replace if necessary. Defective centerfold side registration motor 2. Replace centerfold side registration motor 1. Defective PWB. Replace the centerfold main PWB or finisher main PWB and check for correct operation.
- Code: C8360
- Description: Centerfold main motor problem (optional centerfold unit of 3000-sheet document finisher) The motor lock signal is detected above 1 s during driving the centerfold main motor.
- Causes: Poor contact in the connector terminals. Defective centerfold main motor. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC12 on the centerfold main PWB and the connector of the centerfold main motor, and the continuity across the connector terminals. Repair or replace if necessary. Defective centerfold main motor. Replace the centerfold main motor. Defective PWB. Replace the centerfold main PWB or finisher main PWB and check for correct operation.
- Code: C8440
- Description: Sensor adjusting problem (optional document finisher) The sensor cannot be adjusted within the specified range.
- Causes: The paper entry sensor connector makes poor contact. Defective paper entry sensor. The optical path of the paper entry sensor is blocked by foreign matter. Defective finisher main PWB.
- Remedy: The paper entry sensor connector makes poor contact. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Defective paper entry sensor. Replace the paper entry sensor and check for correct operation. The optical path of the paper entry sensor is blocked by foreign matter. Remove the foreign matter. Defective finisher main PWB. Replace the finisher main PWB and check for correct operation.
- Code: C8460
- Description: EEPROM problem (optional document finisher) Read and write data does not match 3 times in succession.
- Causes: Defective EEPROM or finisher main PWB.
- Remedy: Defective EEPROM or finisher main PWB. Replace the finisher main PWB and check for correct operation.
- Code: C8500
- Description: Mailbox communication error (optional mailbox of 3000-sheet document finisher) Communication with the mailbox is not possible although the connection is detected.
- Causes: Poor contact in the connector terminals. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of the connector of the mailbox and the connector YC7 on the finisher main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective PWB. Replace the mailbox main PWB or finisher main PWB and check for correct operation.
- Code: C8510
- Description: Mailbox drive motor problem (optional mailbox of 3000-sheet document finisher) The motor lock signal is detected above 500 ms during driving the mailbox drive motor.
- Causes: Poor contact in the connector terminals. Defective mailbox drive motor. Defective PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC2 on the mailbox main PWB and the connector of the mailbox drive motor, and the continuity across the connector terminals. Repair or replace if necessary. Defective mailbox drive motor. Replace the mailbox drive motor. Defective PWB. Replace the mailbox main PWB or finisher main PWB and check for correct operation.
- Code: C8900
- Description: Backup memory data problem (optional 3000-sheet document finisher) Read and write data does not match 3 times in succession.
- Causes: Poor contact in the connector terminals. Defective finisher main PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector on the finisher main PWB and the connector of the machine, and the continuity across the connector terminals. Repair or replace if necessary. Defective finisher main PWB. Replace the finisher main PWB and check for correct operation.
- Code: C8910
- Description: Backup memory data problem (optional 3000-sheet document finisher) Read and write data does not match 3 times in succession.
- Causes: Poor contact in the connector terminals. Defective punch PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector on the punch PWB and the connector YC4 on the finisher main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective punch PWB. Replace the punch PWB and check for correct operation.
- Code: C8920
- Description: Backup memory data problem (optional mailbox of 3000-sheet document finisher) Read and write data does not match 3 times in succession.
- Causes: Poor contact in the connector terminals. Defective mailbox main PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector on the mailbox main PWB and the connector YC7 on the finisher main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective mailbox main PWB. Replace the mailbox main PWB and check for correct operation.
- Code: C8930
- Description: Backup memory data problem (optional centerfold unit of 3000-sheet document finisher) Read and write data does not match 3 times in succession.
- Causes: Poor contact in the connector terminals. Defective centerfold main PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector on the centerfold main PWB and the connector YC5 on the finisher main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective centerfold main PWB. Replace the centerfold main PWB and check for correct operation.
- Code: C9060
- Description: EEPROM problem (optional DP) Read and write data does not match.
- Causes: Poor contact in the connector terminals. Defective DP drive PWB.
- Remedy: Poor contact in the connector terminals. Check the connection of connector YC7 on the scanner PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective DP drive PWB. Replace DP drive PWB and check for correct operation.
- Code: C9500 … C9550
- Description: Contact the Service Administrative Division.
- Causes:
- Remedy: Contact the Service Administrative Division.
– Buy WIC Reset key on my online store: https://shop.nguyendangnam.com/product/epson-9000-wic-reset-utility-tool/
– Free Download Epson in specific model: https://dnasofts.com/download-epson-c3500-driver-firmware-and-manuals/
Source:
https://dnasofts.com
https://shop.nguyendangnam.com/
https://nguyendangnam.me/
https://chiplessprinter.com/reset-epson-waste-ink-pad-counter.html
Contact us to get support with Kyocera KMC3232 Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/