Fixing Kyocera KMC1530 Printer Error Codes in details
– Printer model: Kyocera KMC1530
– Fix Error codes on Kyocera KMC1530 model and its description:
- Code: C0000
- Description: Main Motor’s failure to turn
The Main Motor Lock signal remains faulty for a predetermined continuous period of time while the Main Motor is turning. - Remedy: 1 Main Motor turns when the Start key is pressed. NO: Check connector for connection. Correct drive coupling (drive transmitting gear engagement). 2 Main Motor rotation when the Start key is pressed: the voltage across PJ13I-7A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change Master Board. 3 Main Motor rotation when the Start key is pressed: the voltage across PJ7PU1-4 on DC Power Supply 1 and GND is DC 0 V when the motor is deenergized and DC 24 V when the motor is energized. NO: Change DC Power Supply 1.
- Code: C0001
- Description: Main Motor turning at abnormal timing
The Main Motor Lock signal remains faulty for a predetermined continuous period of time while the Main Motor remains stationary. - Remedy: 1 Main Motor rotation while it is being energized: the voltage across PJ13I-7A on Master Board and GND remains DC 0 V. YES: Change Master Board. NO: Change motor.
- Code: C0010
- Description: Imaging Unit Motor C’s failuretoturn
The Lock signal remains faulty for a continuous 1sec. period after the motor rotation has stabilized and before the motor starts decelerating. - Remedy: 1 Imaging Unit Motor turns when the Start key is pressed. NO: Correct drive coupling (drive transmitting gear engagement, coupling engagement). Check that the LED Assy is locked in position. 2 Imaging Unit Motor rotation when the Start key is pressed: Cyan: the voltage across PJ12I-3B on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Magenta: the voltage across PJ12I-7A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Yellow: the voltage across PJ12I-3A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Black: the voltage across PJ12I-7B on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change Master Board.
- Code: C0011
- Description: Imaging Unit Motor C turning at abnormal timing
The Lock signal remains faulty for a continuous 1sec. period after the motor has completely stopped and before the motor starts accelerating. - Remedy: 1 Imaging Unit Motor rotation while it is being energized: Cyan: the voltage across PJ12I-3B on Master Board and GND remains DC 0 V. Magenta: the voltage across PJ12I-7A on Master Board and GND remains DC 0 V. Yellow: the voltage across PJ12I-3A on Master Board and GND remains DC 0 V. Black: the voltage across PJ12I-7B on Master Board and GND remains DC 0 V. YES: Change Master Board. NO: Change motor.
- Code: C0012
- Description: Imaging Unit Motor M’s failuretoturn
The Lock signal remains faulty for a continuous 1sec. period after the motor rotation has stabilized and before the motor starts decelerating. - Remedy: 1 Imaging Unit Motor turns when the Start key is pressed. NO: Correct drive coupling (drive transmitting gear engagement, coupling engagement). Check that the LED Assy is locked in position. 2 Imaging Unit Motor rotation when the Start key is pressed: Cyan: the voltage across PJ12I-3B on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Magenta: the voltage across PJ12I-7A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Yellow: the voltage across PJ12I-3A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Black: the voltage across PJ12I-7B on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change Master Board.
- Code: C0013
- Description: Imaging Unit Motor M turning at abnormal timing
The Lock signal remains faulty for a continuous 1sec. period after the motor has completely stopped and before the motor starts accelerating. - Remedy: 1 Imaging Unit Motor rotation while it is being energized: Cyan: the voltage across PJ12I-3B on Master Board and GND remains DC 0 V. Magenta: the voltage across PJ12I-7A on Master Board and GND remains DC 0 V. Yellow: the voltage across PJ12I-3A on Master Board and GND remains DC 0 V. Black: the voltage across PJ12I-7B on Master Board and GND remains DC 0 V. YES: Change Master Board. NO: Change motor.
- Code: C0014
- Description: Imaging Unit Motor Y’s failure to turn
The Lock signal remains faulty for a continuous 1sec. period after the motor rotation has stabilized and before the motor starts decelerating. - Remedy: 1 Imaging Unit Motor turns when the Start key is pressed. NO: Correct drive coupling (drive transmitting gear engagement, coupling engagement). Check that the LED Assy is locked in position. 2 Imaging Unit Motor rotation when the Start key is pressed: Cyan: the voltage across PJ12I-3B on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Magenta: the voltage across PJ12I-7A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Yellow: the voltage across PJ12I-3A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Black: the voltage across PJ12I-7B on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change Master Board.
- Code: C0015
- Description: Imaging Unit Motor Y turning at abnormal timing
The Lock signal remains faulty for a continuous 1sec. period after the motor has completely stopped and before the motor starts accelerating. - Remedy: 1 Imaging Unit Motor rotation while it is being energized: Cyan: the voltage across PJ12I-3B on Master Board and GND remains DC 0 V. Magenta: the voltage across PJ12I-7A on Master Board and GND remains DC 0 V. Yellow: the voltage across PJ12I-3A on Master Board and GND remains DC 0 V. Black: the voltage across PJ12I-7B on Master Board and GND remains DC 0 V. YES: Change Master Board. NO: Change motor.
- Code: C0016
- Description: Imaging Unit Motor Bk’s failuretoturn
The Lock signal remains faulty for a continuous 1sec. period after the motor rotation has stabilized and before the motor starts decelerating. - Remedy: 1 Imaging Unit Motor turns when the Start key is pressed. NO: Correct drive coupling (drive transmitting gear engagement, coupling engagement). Check that the LED Assy is locked in position. 2 Imaging Unit Motor rotation when the Start key is pressed: Cyan: the voltage across PJ12I-3B on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Magenta: the voltage across PJ12I-7A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Yellow: the voltage across PJ12I-3A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. Black: the voltage across PJ12I-7B on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change Master Board.
- Code: C0017
- Description: Imaging Unit Motor Bk turning at abnormal timing
The Lock signal remains faulty for a continuous 1sec. period after the motor has completely stopped and before the motor starts accelerating. - Remedy: 1 Imaging Unit Motor rotation while it is being energized: Cyan: the voltage across PJ12I-3B on Master Board and GND remains DC 0 V. Magenta: the voltage across PJ12I-7A on Master Board and GND remains DC 0 V. Yellow: the voltage across PJ12I-3A on Master Board and GND remains DC 0 V. Black: the voltage across PJ12I-7B on Master Board and GND remains DC 0 V. YES: Change Master Board. NO: Change motor.
- Code: C0040
- Description: Fusing Cooling Fan Motor 2’s failure to turn
A Fusing Cooling Fan Lock signal is detected for a continuous 3-sec. period while Fusing Cooling Fan Motor 2 is turning. - Remedy: 1 Fusing Cooling Fan Motor 1 turns when the Start key is pressed. NO Check connector for connection. Check fan for overload. 2 Fusing Cooling Fan Motor 1 rotation when the Start key is pressed: the voltage across PJ14I-13A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change Master Board. NO: Change motor.
- Code: C0046
- Description: Fusing Cooling Fan Motor 1’s failure to turn
A Fusing Cooling Fan Lock signal is detected for a continuous 3-sec. period while the Fusing Cooling Fan Motor is turning. - Remedy: 1 Fusing Cooling Fan Motor 2 turns when the Start key is pressed. NO Check connector for connection. Check fan for overload. 2 Fusing Cooling Fan Motor 2 rotation when the Start key is pressed: the voltage across PJ14I-3A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change Master Board.
- Code: C004C
- Description: Ozone Ventilation Fan Motor’s failure to turn
An Ozone Fan Lock signal is detected for a continuous 3-sec. period while the Ozone Ventilation Fan Motor is turning. - Remedy: 1 Ozone Ventilation Fan Motor turns when the Start key is pressed. NO: Check connector for connection. Check fan for overload. 2 Ozone Ventilation Fan Motor rotation when the Start key is pressed: the voltage across PJ10I-15 on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. NO: Change Master Board. 3 Ozone Ventilation Fan Motor rotation when the Start key is pressed: the voltage across CN2HV3-3 on High Voltage Unit 3 and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change High Voltage Unit 3.
- Code: C004E
- Description: Power Supply Cooling Fan Motor’s failure to turn
A Power Supply Cooling Fan Lock signal is detected for a continuous 3-sec. period while the Power Supply Cooling Fan Motor is turning. - Remedy: 1 Power Supply Cooling Fan Motor turns when the Start key is pressed. NO: Check connector for connection. Check fan for overload. 2 Power Supply Cooling Fan Motor rotation when the Start key is pressed: the voltage across PJ13PU1-3 on DC Power Supply 1 and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change DC Power Supply 1.
- Code: C0060
- Description: Fusing Drive Motor’s failure to turn
A Fusing Drive Motor Lock signal remains faulty for a predetermined continuous period of time while the Fusing Drive Motor is turning. - Remedy: 1 Fusing Drive Motor turns when the Start key is pressed. NO: Check connector for connection. Correct drive coupling (drive transmitting gear engagement). 2 Fusing Drive Motor rotation when the Start key is pressed: the voltage across PJ13I-1A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change Master Board. 3 Fusing Drive Motor rotation when the Start key is pressed: the voltage across PJ7PU1- 4 on DC Power Supply 1 and GND is DC 0 V when the motor is deenergized and DC 24 V when the motor is energized. NO Change DC Power Supply 1.
- Code: C0061
- Description: Fusing Drive Motor turning at abnormal timing
The Fusing Drive Motor Lock signal remains faulty for a predetermined continuous period of time while the Fusing Drive Motor remains stationary. - Remedy: 1 Fusing Drive Motor rotation while it is being energized: the voltage across PJ13I-1A on Master Board and GND remains DC 0 V. YES: Change Master Board. NO: Change motor.
- Code: C0094
- Description: 2nd Image Transfer Roller pressure/retraction failure
• The 2nd Image Transfer Pressure Position Sensor is not activated (retracted position) within 1 sec. after the 2nd Image Transfer Roller has started its retracting motion. • The 2nd Image Transfer Pressure Position Sensor is not deactivated (not the retracted position) within 1 sec. after the 2nd Image Transfer Roller has started its pressing motion. - Remedy: 1 While the 2nd Image Transfer Pressure/ Retraction Clutch is supposed to be deenergized during timing of pressure/retraction operation: the voltage across PJ14I-9A on Master Board and GND is DC 24 V when the clutch is deenergized and DC 0 V when the clutch is energized. YES: Check connector for connection. Check for overload. Change clutch. NO: Change Master Board. 2 I/O check for 2nd Image Transfer Pressure Position Sensor operation during pressure/ retraction operation: the voltage across PJ14I-6B on Master Board and GND is DC 0 V when the sensor is unblocked and DC 5 V when the sensor is blocked (pressed position). YES: Change Master Board. NO: Correct actuator. Check sensor connector for connection. Change sensor.
- Code: C0096
- Description: 1st Image Transfer Roller pressure/retraction failure
• The 1st Image Transfer Retraction Position Sensor is not activated (retracted position) within 3 sec. after the 1st Image Transfer Pressure/Retraction Motor has started turning. • The 1st Image Transfer Retraction Position Sensor is not deactivated (pressed position) within 1.5 sec. after the 1st Image Transfer Pressure/Retraction Motor has started turning. - Remedy: 1 1st Image Transfer Pressure/Retraction Motor turns during pressure/retraction operation. NO: Check connector for connection. Correct drive coupling (drive transmitting gear engagement). Change motor. Change Master Board. 2 I/O check for 1st Image Transfer Retraction Position Sensor operation during pressure/ retraction operation: the voltage across PJ17I-1A on Master Board and GND is DC 0 V when the sensor is unblocked and DC 5 V when the sensor is blocked (retracted position). YES: Change Master Board. NO: Correct actuator. Check sensor connector for connection. Change sensor.
- Code: C0098
- Description: Fusing Roller pressure/ retraction failure
• No change is observed in the encoder pulse even after the lapse of 0.5 sec. after the Fusing Pressure/Retraction Motor has started turning for retraction direction during retraction control. • No change is observed in the encoder pulse even after the lapse of 0.5 sec. after the Fusing Pressure/Retraction Motor has started turning for pressure direction during pressure control. • The Fusing Pressure Position Sensor is not activated (pressed position) even when 31 motor encoder pulses have been counted after the Fusing Pressure/Retraction Motor has started turning for pressure direction during pressure control. - Remedy: 1 Fusing Pressure/Retraction Motor rotation when the Fusing Roller is retracted: the voltage across PJ14I-4A on Master Board and GND is DC 0 V when the motor is deenergized and DC 24 V when the motor is energized. YES: Check motor connector for connection. Change motor. NO: Change Master Board. 2 I/O check for Fusing Pressure Position Sensor when the Fusing Roller is retracted: the voltage across PJ6I-11B on Master Board and GND is DC 0 V when the sensor is unblocked (retracted position) and DC 5 V when the sensor is blocked. YES: Change Master Board. NO: Check sensor installation. Correct detecting plate. Check sensor connector for connection. Change sensor. 3 Fusing Pressure/Retraction Motor rotation when the Fusing Roller is pressed: the voltage across PJ14I-5A on Master Board and GND is DC 0 V when the motor is deenergized and DC 24 V when the motor is energized. NO: Change Master Board. 4 I/O check for Fusing Pressure Position Sensor when the Fusing Roller is pressed: the voltage across PJ6I-11B on Master Board and GND is DC 0 V when the sensor is unblocked and DC 5 V when the sensor is blocked (pressed position). YES: Change Master Board. NO: Check sensor installation. Correct detecting plate. Check sensor connector for connection. Change sensor. 5 I/O check for Fusing Retraction Position Sensor operation while the Fusing Pressure/ Retraction Motor is turning: the voltage across PJ17I-3B on Master Board and GND remains DC 0 V when the sensor is unblocked or remains DC 5 V when the sensor is blocked while the motor remains stationary, and alternates between DC 0 V when the sensor is unblocked and DC 5 V when the sensor is blocked while the motor is turning. YES: Change Master Board. NO: Check sensor installation. Correct detecting plate. Check sensor connector for connection. Change sensor.
- Code: C0200
- Description: Cyan PC Drum Charge Corona malfunction
The SCD signal remains inactive for a continuous 1sec. period while charge corona is being output (i.e., the Remote signal is being turned ON). - Remedy: 1 Imaging Unit contact failure YES: Correct or clean Imaging Unit contact. 2 High Voltage Unit 1 contact failure YES: Correct or clean High Voltage Unit 1 contact. 3 After corona output has been turned ON: Cyan (C0200): The voltage across PJ9I-10 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Magenta (C0202): The voltage across PJ9I-8 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Yellow (C0204): The voltage across PJ9I-6 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Bk (C0206): The voltage across PJ9I-12 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. YES: Change High Voltage Unit 1. NO: Change Master Board.oard.
- Code: C0202
- Description: Magenta PC Drum Charge Corona malfunction
The SCD signal remains inactive for a continuous 1sec. period while charge corona is being output (i.e., the Remote signal is being turned ON). - Remedy: 1 Imaging Unit contact failure YES: Correct or clean Imaging Unit contact. 2 High Voltage Unit 1 contact failure YES: Correct or clean High Voltage Unit 1 contact. 3 After corona output has been turned ON: Cyan (C0200): The voltage across PJ9I-10 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Magenta (C0202): The voltage across PJ9I-8 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Yellow (C0204): The voltage across PJ9I-6 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Bk (C0206): The voltage across PJ9I-12 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. YES: Change High Voltage Unit 1. NO: Change Master Board.oard.
- Code: C0204
- Description: Yellow PC Drum Charge Corona malfunction
The SCD signal remains inactive for a continuous 1sec. period while charge corona is being output (i.e., the Remote signal is being turned ON). - Remedy: 1 Imaging Unit contact failure YES: Correct or clean Imaging Unit contact. 2 High Voltage Unit 1 contact failure YES: Correct or clean High Voltage Unit 1 contact. 3 After corona output has been turned ON: Cyan (C0200): The voltage across PJ9I-10 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Magenta (C0202): The voltage across PJ9I-8 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Yellow (C0204): The voltage across PJ9I-6 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Bk (C0206): The voltage across PJ9I-12 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. YES: Change High Voltage Unit 1. NO: Change Master Board.oard.
- Code: C0206
- Description: Black PC Drum Charge Corona malfunction
The SCD signal remains inactive for a continuous 1sec. period while charge corona is being output (i.e., the Remote signal is being turned ON). - Remedy: 1 Imaging Unit contact failure YES: Correct or clean Imaging Unit contact. 2 High Voltage Unit 1 contact failure YES: Correct or clean High Voltage Unit 1 contact. 3 After corona output has been turned ON: Cyan (C0200): The voltage across PJ9I-10 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Magenta (C0202): The voltage across PJ9I-8 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Yellow (C0204): The voltage across PJ9I-6 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Bk (C0206): The voltage across PJ9I-12 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. YES: Change High Voltage Unit 1. NO: Change Master Board.oard.
- Code: C0400
- Description: Exposure Lamp’s failure to turn ON
A Lamp-Out Detection signal is ON after the lapse of 5 sec. after the Exposure Lamp has been turned ON. - Remedy: 1 Exposure Lamp conduction NO: Change Exposure Lamp. 2 Temperature Fuse conduction. NO: Change Temperature Fuse. 3 Flat Cable conduction NO: Check for correct installation or change. 4 The problem has been eliminated through the checks of steps up to 3. NO: Change DC Power Supply 2. 5 Exposure Lamp turns ON and OFF correctly after DC Power Supply 2 has been replaced. NO: Change Image Processing Board.
– Kyocera KMC1530 printer Error Codes and quick guide to troubleshooting:
- Code: C0410
- Description: Exposure Lamp turning ON at abnormal timing
CCD Sensoroutputsare writteninlineRAM at the end of a scan job and the average of these readings exceeds a predetermined value. - Remedy: 1 Exposure Lamp conduction NO: Change Exposure Lamp. 2 Temperature Fuse conduction. NO: Change Temperature Fuse. 3 Flat Cable conduction NO: Check for correct installation or change. 4 The problem has been eliminated through the checks of steps up to 3. NO: Change DC Power Supply 2. 5 Exposure Lamp turns ON and OFF correctly after DC Power Supply 2 has been replaced. NO: Change Image Processing Board.
- Code: C0500
- Description: Heating Roller warm-up failure (Fusing Thermistor 1)
• Fusing Thermistor 1 does not detect a predetermined temperature and the warm-up cycle is not completed within the period of 9 min. 10 sec. after the warm-up cycle has been started. • The temperature of Fusing Thermistor 1 does not rise to a level more than the predetermined output value within 30 sec. after the warm-up cycle has started. - Remedy: 1 Fusing Unit condition: the resistance across CN4-15 and 16 on the Fusing Unit end is infinity with CN4 (2P) disconnected. YES: Change Fusing Unit. NO: Change Master Board. 2 Heating Roller Heater Lamps turn ON. YES: Change DC Power Supply 1. Change Master Board. NO: Change Fusing Unit.
- Code: C0501
- Description: Lower Fusing Roller Heater Lamp warm-up failure (Fusing Thermistor 2)
•The temperature of Fusing Thermistor 2 does not reach 100 C within 180 sec. after the warm-up cycle has started. • The temperature of Fusing Thermistor 1 does not rise to a level more than the predetermined output value within 130 sec. after the warm-up cycle has started. - Remedy: 1 Fusing Unit condition: the resistance across CN4-17 and 18 on the Fusing Unit end is infinity with CN4 (2P) disconnected. YES: Change Fusing Unit. NO: Change Master Board. 2 Lower Fusing Roller Heater Lamp turns ON. YES: Change DC Power Supply 1. Change Master Board. NO: Change Fusing Unit.
- Code: C0510
- Description: Heating Roller abnormally low temperature (Fusing Thermistor 1)
• The temperature of Fusing Thermistor 1 remains below 120 C for 1 sec. or more in the standby state. • The temperature of Fusing Thermistor 1 remains below 130 C for 1 sec. or more during a print cycle. • The temperature of Fusing Thermistor 1 remains below 90 C for 1 sec. or more in the Energy Saver mode. - Remedy: 1 Fusing Unit condition: the resistance across CN4-15 and 16 on the Fusing Unit end is infinity with CN4 (2P) disconnected. YES: Change Fusing Unit. NO: Change Master Board. 2 Heating Roller Heater Lamps turn ON. YES: Change DC Power Supply 1. Change Master Board. NO: Change Fusing Unit.
- Code: C0511
- Description: Lower Fusing Roller Heater Lamp abnormally low temperature (Fusing Thermistor 2)
• The temperature of Fusing Thermistor 2 remains below 100 C for 1 sec. or more in the standby state. • The temperature of Fusing Thermistor 2 remains below 100 C for 1 sec. or more during a print cycle. • The temperature of Fusing Thermistor 2 remains below 100 C for 1 sec. or more in the Energy Saver mode. - Remedy: 1 Fusing Unit condition: the resistance across CN4-17 and 18 on the Fusing Unit end is infinity with CN4 (2P) disconnected. YES: Change Fusing Unit. NO: Change Master Board. 2 Lower Fusing Roller Heater Lamp turns ON. YES: Change DC Power Supply 1. Change Master Board. NO: Change Fusing Unit.
- Code: C0520
- Description: Heating Roller abnormally high temperature (Fusing Thermistor 1)
The temperature of Fusing Thermistor 1 remains above 220 C for 1 sec. or more at all times. - Remedy: 1 Fusing Unit condition: the resistance across CN4-15 and 16 on the Fusing Unit end is 0 Om (or close to 0) with CN4 (2P) disconnected. YES: Change Fusing Unit. NO: Change Master Board..
- Code: C0521
- Description: Lower Fusing Roller Heater Lamp abnormally high temperature (Fusing Thermistor 2)
The temperature of Fusing Thermistor 2 remains above 190 C for 1 sec. or more at all times. - Remedy: 1 Fusing Unit condition: the resistance across CN4-15 and 16 on the Fusing Unit end is 0 W (or close to 0) with CN4 (2P) disconnected. YES: Change Fusing Unit. NO: Change Master Board.
- Code: C0650
- Description: Scanner Home Sensor malfunction
• The Scanner Home Sensor fails to detect the Scanner at its home position though the Scanner is so located. • The Scanner Home Sensor fails to detect the Scanner though the motor has been energized to move the Scanner over the maximum distance. • The Scanner Home Sensor detects the Scanner at its home position though the Scanner has moved 5 mm away from the home position. - Remedy: 1 Scanner can be moved manually. NO: Correct drive coupling (Scanner Belt tension, pulley operation, drive cable tension) 2 Scan motion: initial scan motion after the Power Switch has been turned ON or Front Door has been opened and closed. NO: Carry out misfeed/malfunction troubleshooting procedures. 3 Connectors are connected properly on Scanner Motor Drive Board: PWB-IC PJ1IC, PJ2IC, and PJ3IC. NO: Check connectors for connection. 4 Scanner Motor turns when the Start key is pressed. NO: Check connectors for connection. Change motor. Change Scanner Motor Drive Board. 5 I/O check for Scanner Home Sensor: the voltage across PJ6C-2 on Image Processing Board and GND is DC 0 V (home position) when the sensor is blocked and DC 5 V when the sensor is unblocked. YES: Change Image Processing Board. NO: Check sensor for installation. Correct detecting plate. Check sensor connector for connection. Change sensor. 6 “IR Area” check: Malfunction when Power Switch is turned ON after “Top Image” has been set to 0 and “FD-Mag.” to 1.000. NO: Adjust “IR Area” data.
- Code: C0660
- Description: Scanner overrun failure
The Scanner Home Sensor detects the Scanner at its home position during a period from when the prescan command and scan preparation command have been executed to when home return command is executed. - Remedy: 1 Scanner can be moved manually. NO: Correct drive coupling (Scanner Belt tension, pulley operation, drive cable tension) 2 Scan motion: initial scan motion after the Power Switch has been turned ON or Front Door has been opened and closed. NO: Carry out misfeed/malfunction troubleshooting procedures. 3 Connectors are connected properly on Scanner Motor Drive Board: PWB-IC PJ1IC, PJ2IC, and PJ3IC. NO: Check connectors for connection. 4 Scanner Motor turns when the Start key is pressed. NO: Check connectors for connection. Change motor. Change Scanner Motor Drive Board. 5 I/O check for Scanner Home Sensor: the voltage across PJ6C-2 on Image Processing Board and GND is DC 0 V (home position) when the sensor is blocked and DC 5 V when the sensor is unblocked. YES: Change Image Processing Board. NO: Check sensor for installation. Correct detecting plate. Check sensor connector for connection. Change sensor. 6 “IR Area” check: Malfunction when Power Switch is turned ON after “Top Image” has been set to 0 and “FD-Mag.” to 1.000. NO: Adjust “IR Area” data.
- Code: C0990
- Description: LCC Lift-Up Motor malfunction
- Remedy: 1 LCC Lift-Up Motor turns after the LCC Drawer has been slid into position while the LCC Drawer is being used. NO: Change motor. Change LCC Control Board.
- Code: C0991
- Description: LCC Lift 1 ascent motion failure
- Remedy: 1 Lift 1 ascends after the LCC Lift-Up Motor has been energized. NO: Correct drive coupling (oneway gear engagement, coupling engagement, spring operation, and belt tension). 2 I/O check for Lift-Up Sensor 1 operation: the voltage across CN4A-6 on LCC Control Board and GND is DC 0 V when the sensor is unblocked and DC 5 V when the sensor is blocked (during lifting motion detection). YES: Change LCC Control Board. NO: Check sensor for installation. Check sensor connector for connection. Change sensor.
- Code: C0995
- Description: LCC Transport Motor malfunction
- Remedy: 1 LCC Lift-Up Motor turns when the Start key is pressed while the LCC Drawer is being used. NO: Change motor. Change LCC Control Board.
- Code: C0999
- Description: LCC Lift 2 ascent motion failure
- Remedy: 1 Lift 2 ascends after the LCC Lift-Up Motor has been energized. NO: Correct drive coupling (oneway gear engagement, coupling engagement, spring operation, and belt tension). 2 I/O check for Lift-Up Sensor 2 operation: the voltage across CN4A-9 on LCC Control Board and GND is DC 0 V when the sensor is unblocked and DC 5 V when the sensor is blocked (during lifting motion detection). YES: Change LCC Control Board. NO: Check sensor for installation. Check sensor connector for connection. Change sensor.
- Code: C0B00
- Description: Finishing option transport drive malfunction
- Remedy:
- Code: C0B20
- Description: Stapling Unit CD drive malfunction
- Remedy:
- Code: C0B30
- Description: Finishing option Paper Aligning Bar moving mechanism malfunction
- Remedy:
- Code: C0B48
- Description: Finishing option Exit Roll pressure/retraction failure
- Remedy:
- Code: C0B4A
- Description: Finishing option Storage Roller pressure/retraction failure
- Remedy:
- Code: C0B50
- Description: Finishing option stapling mechanism 1
- Remedy:
- Code: C0B54
- Description: Finishing option stapling mechanism 2
- Remedy:
- Code: C0B73
- Description: Finishing option punch cam motor mechanism malfunction
- Remedy:
- Code: C0B78
- Description: Finishing option punch selector motor mechanism malfunction
- Remedy:
- Code: C0B80
- Description: Finishing option Shift Motor mechanism malfunction
- Remedy:
- Code: C0BA0
- Description: Finishing option Elevator Tray drive failure
- Remedy:
- Code: C0F30
- Description: Abnormally low toner density detected by Cyan ATDC Sensor
Toner density that is 2 % or more lower than the target level is detected ten consecutive times during a print cycle, ATVC, or image stabilization sequence. - Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 ATDC Sensor spring moving part operates properly. NO: Correct. 3 Hopper supplies toner properly. NO: Correct. 4 ATDC Sensor LED is dirty. YES: Clean. 5 ATDC Sensor LED emits light properly. NO: Check connector for connection. Check harness. 6 Imaging Unit Shutter operates properly. NO: Correct. 7 The problem has been eliminated through the checks of steps up to 6. NO: Change Master Board.
- Code: C0F31
- Description: Abnormally high toner density detected by Cyan ATDC Sensor
Toner density that is 4 % or more higher than the target level is detected ten consecutive times during a print cycle, ATVC, or image stabilization sequence. - Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 Bias voltage is properly applied to the ATDC Sensor window. NO: Check wiring. 3 The problem has been eliminated through the checks of steps up to 2. NO: Change Master Board.
- Code: C0F32
- Description: Abnormally low toner density detected by Magenta ATDC Sensor
Toner density that is 2 % or more lower than the target level is detected ten consecutive times during a print cycle, ATVC, or image stabilization sequence. - Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 ATDC Sensor spring moving part operates properly. NO: Correct. 3 Hopper supplies toner properly. NO: Correct. 4 ATDC Sensor LED is dirty. YES: Clean. 5 ATDC Sensor LED emits light properly. NO: Check connector for connection. Check harness. 6 Imaging Unit Shutter operates properly. NO: Correct. 7 The problem has been eliminated through the checks of steps up to 6. NO: Change Master Board.
- Code: C0F33
- Description: Abnormally high toner density detected by Magenta ATDC Sensor
Toner density that is 4 % or more higher than the target level is detected ten consecutive times during a print cycle, ATVC, or image stabilization sequence. - Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 Bias voltage is properly applied to the ATDC Sensor window. NO: Check wiring. 3 The problem has been eliminated through the checks of steps up to 2. NO: Change Master Board.
- Code: C0F34
- Description: Abnormally low toner density detected by Yellow ATDC Sensor
Toner density that is 2 % or more lower than the target level is detected ten consecutive times during a print cycle, ATVC, or image stabilization sequence. - Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 ATDC Sensor spring moving part operates properly. NO: Correct. 3 Hopper supplies toner properly. NO: Correct. 4 ATDC Sensor LED is dirty. YES: Clean. 5 ATDC Sensor LED emits light properly. NO: Check connector for connection. Check harness. 6 Imaging Unit Shutter operates properly. NO: Correct. 7 The problem has been eliminated through the checks of steps up to 6. NO: Change Master Board.
- Code: C0F35
- Description: Abnormally high toner density detected by Yellow ATDC Sensor
Toner density that is 4 % or more higher than the target level is detected ten consecutive times during a print cycle, ATVC, or image stabilization sequence. - Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 Bias voltage is properly applied to the ATDC Sensor window. NO: Check wiring. 3 The problem has been eliminated through the checks of steps up to 2. NO: Change Master Board.
- Code: C0F36
- Description: Abnormally low toner density detected by Black ATDC Sensor
Toner density that is 2 % or more lower than the target level is detected ten consecutive times during a print cycle, ATVC, or image stabilization sequence. - Remedy: 1 Image density is low. YES: Check and correct Imaging Unit Bk Shutter. 2 The problem has been eliminated through the check of step 1. NO: Check and correct Hopper. 3 The problem has been eliminated through the check of step 2. NO: Change Master Board.
- Code: C0F37
- Description: Abnormally high toner density detected by Black ATDC Sensor
Toner density that is 4 % or more higher than the target level is detected ten consecutive times during a print cycle, ATVC, or image stabilization sequence. - Remedy: 1 Imaging Unit Bk is installed correctly. NO: Reinstall. 2 Each of Imaging Unit Bk contacts makes good contact. NO: Clean or correct. 3 ATDC Sensor harness is open-circuited. YES: Change Imaging Unit Bk.Chan
- Code: C0F3A
- Description: Cyan ATDC Sensor adjustment failure
Cyan ATDC Sensor adjustment does not function properly, failing to adjust to an appropriate value. - Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 Imaging Unit window for ATDC Sensor is dirty. YES: Clean. 3 LED retracting lever is locked in position. NO: Slide out the Imaging Unit and then reinstall. 4 The problem has been eliminated through the checks of steps up to 3. NO: Check ATDC Sensor connector. Change ATDC Sensor. 5 The problem is eliminated after the ATDC Sensor has been replaced. NO: Change Imaging Unit. 6 The problem is eliminated after the Imaging Unit has been replaced. NO: Change Master Board.
- Code: C0F3B
- Description: Magenta ATDC Sensor adjustment failure
Magenta ATDC Sensor adjustment does not function properly, failing to adjust to an appropriate value. - Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 Imaging Unit window for ATDC Sensor is dirty. YES: Clean. 3 LED retracting lever is locked in position. NO: Slide out the Imaging Unit and then reinstall. 4 The problem has been eliminated through the checks of steps up to 3. NO: Check ATDC Sensor connector. Change ATDC Sensor. 5 The problem is eliminated after the ATDC Sensor has been replaced. NO: Change Imaging Unit. 6 The problem is eliminated after the Imaging Unit has been replaced. NO: Change Master Board.
- Code: C0F3C
- Description: Yellow ATDC Sensor adjustment failure
Yellow ATDC Sensor adjustment does not function properly, failing to adjust to an appropriate value. - Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 Imaging Unit window for ATDC Sensor is dirty. YES: Clean. 3 LED retracting lever is locked in position. NO: Slide out the Imaging Unit and then reinstall. 4 The problem has been eliminated through the checks of steps up to 3. NO: Check ATDC Sensor connector. Change ATDC Sensor. 5 The problem is eliminated after the ATDC Sensor has been replaced. NO: Change Imaging Unit. 6 The problem is eliminated after the Imaging Unit has been replaced. NO: Change Master Board.
- Code: C0F3D
- Description: Black ATDC Sensor adjustment failure
Black ATDC Sensor adjustment does not function properly, failing to adjust to an appropriate value. - Remedy: 1 Malfunction code C0F3D is displayed. YES: Change Imaging Unit. 2 The problem is eliminated after the Imaging Unit has been replaced. NO: Check harness. Check connector for connection. Change Master Board
- Code: C13C8
- Description: New Transfer Belt Unit resetting failure
The output from the new unit detecting terminal remains HIGH and the copier does not recognize that a new unit has been installed. 1. After an image stabilization sequence is completed, the fuse blowout signal of the new unit is set to a blowout state. 2. After the lapse of 2 sec. after step 1, the fuse blowout signal is brought to a state where no new units are installed. 3. After the lapse of 0.1 sec. after step 2, a new unit check sequence is carried out. A total of three cycles of steps 1 to 3 are carried out and, if the copier fails to detect a new unit a third time, a malfunction condition results. - Remedy: 1 Each unit is installed properly in the copier (good contact connection). YES: Change Master Board. NO: Reinstall.
- Code: C13CA
- Description: New Fusing Unit resetting failure
The output from the new unit detecting terminal remains HIGH and the copier does not recognize that a new unit has been installed. 1. The fuse blowout signal of the new unit is set to a blowout state. 2. After the lapse of 0.5 sec. after step 1, the fuse blowout signal is brought to a state where no new units are installed. 3. After the lapse of 0.1 sec. after step 2, a new unit check sequence is carried out. A total of two cycles of steps 1 to 3 are carried out and, if the copier fails to detect a new unit a second time, a malfunction condition results. - Remedy: 1 Each unit is installed properly in the copier (good contact connection). YES: Change Master Board. NO: Reinstall.
- Code: C13CB
- Description: New Fusing Web Unit resetting failure
The output from the new unit detecting terminal remains HIGH and the copier does not recognize that a new unit has been installed. 1. The fuse blowout signal of the new unit is set to a blowout state. 2. After the lapse of 0.5 sec. after step 1, the fuse blowout signal is brought to a state where no new units are installed. 3. After the lapse of 0.1 sec. after step 2, a new unit check sequence is carried out. A total of two cycles of steps 1 to 3 are carried out and, if the copier fails to detect a new unit a second time, a malfunction condition results - Remedy: 1 Each unit is installed properly in the copier (good contact connection). YES: Change Master Board. NO: Reinstall.
- Code: C13CC
- Description: New Oil Coating Unit resetting failure
The output from the new unit detecting terminal remains HIGH and the copier does not recognize that a new unit has been installed. 1. The fuse blowout signal of the new unit is set to a blowout state. 2. After the lapse of 0.5 sec. after step 1, the fuse blowout signal is brought to a state where no new units are installed. 3. After the lapse of 0.1 sec. after step 2, a new unit check sequence is carried out. A total of two cycles of steps 1 to 3 are carried out and, if the copier fails to detect a new unit a second time, a malfunction condition results. - Remedy: 1 Each unit is installed properly in the copier (good contact connection). YES: Change Master Board. NO: Reinstall.
- Code: C13D1
- Description: Cyan IU EEPROM failure
EEPROM access error: When EEPROM access control is executed, setting 1 “Start Flag” of GA register does not become ready even after the lapse of a predetermined period of time. - Remedy: 1 Imaging Unit is installed properly. NO: Reinstall. 2 Connector between the Imaging Unit and copier is dirty. YES: Clean. 3 The problem has been eliminated through the checks of steps up to 2. NO: Change Imaging Unit. 4 The problem is eliminated after the Imaging Unit has been replaced. NO: Change Master Board.
- Code: C13D2
- Description: Magenta IU EEPROM failure
EEPROM access error: When EEPROM access control is executed, setting 1 “Start Flag” of GA register does not become ready even after the lapse of a predetermined period of time. - Remedy: 1 Imaging Unit is installed properly. NO: Reinstall. 2 Connector between the Imaging Unit and copier is dirty. YES: Clean. 3 The problem has been eliminated through the checks of steps up to 2. NO: Change Imaging Unit. 4 The problem is eliminated after the Imaging Unit has been replaced. NO: Change Master Board.
- Code: C13D3
- Description: Yellow IU EEPROM failure
EEPROM access error: When EEPROM access control is executed, setting 1 “Start Flag” of GA register does not become ready even after the lapse of a predetermined period of time. - Remedy: 1 Imaging Unit is installed properly. NO: Reinstall. 2 Connector between the Imaging Unit and copier is dirty. YES: Clean. 3 The problem has been eliminated through the checks of steps up to 2. NO: Change Imaging Unit. 4 The problem is eliminated after the Imaging Unit has been replaced. NO: Change Master Board.
- Code: C13D4
- Description: Black IU EEPROM failure
EEPROM access error: When EEPROM access control is executed, setting 1 “Start Flag” of GA register does not become ready even after the lapse of a predetermined period of time. - Remedy: 1 Imaging Unit is installed properly. NO: Reinstall. 2 Connector between the Imaging Unit and copier is dirty. YES: Clean. 3 The problem has been eliminated through the checks of steps up to 2. NO: Change Imaging Unit. 4 The problem is eliminated after the Imaging Unit has been replaced. NO: Change Master Board.
- Code: C3310
- Description: CCD clamp/gain adjustment failure
• When clamp adjustment is made: (AVE1 -AVE2) =< 4 • When gain adjustment is made: The average of CCD Sensor output values is 1 or less. Dgain = 0 Dgain = 255 - Remedy: 1 Check that each of the values displayed on the screen falls within the above range. 2 There is a wide difference between the clamp and gain adjustment values, the value being close to “0” or “255.” YES: Make positive connection of the harness connectors between CCD Sensor Board and Image Processing Board. 3 Clamp adjustment value exceeds the allowable range. YES: Reinstall covers, as extraneous light is the cause of the problem. 4 The lamp adjustment value or gain value exceeds the upper limit of the allowable range, being abnormally great. YES: Clean lens, mirrors, CCD surface, shading sheet, and related parts. 5 The lamp adjustment value or gain value falls short of the lower limit of the allowable range, being abnormally small. YES: Reinstall covers, as extraneous light is the cause of the problem. Change Scanner, as the reflectors are deformed.
- Code: C3700
- Description: IR Cooling Fan Motor 1 turning at abnormal timing
A Lock signal is detected ten consecutive times when it is monitored at 0.01-sec. intervals while a Fan Motor ON signal is being output and, at the same time, after the lapse of 2 sec. or more after the output of the Fan Motor ON signal has been started. - Remedy: 1 IR Cooling Fan Motor 1 rotation: the voltage across PJ6C-6 on Image Processing Board and GND remains DC 0 V while the motor is turning. YES: Change Image Processing Board. NO: Change motor. Master Board
- Code: C3710
- Description: IR Cooling Fan Motor 2 turning at abnormal timing
A Lock signal is detected ten consecutive times when it is monitored at 0.01-sec. intervals while a Fan Motor ON signal is being output and, at the same time, after the lapse of 2 sec. or more after the output of the Fan Motor ON signal has been started. - Remedy: 1 IR Cooling Fan Motor 2 rotation: the voltage across PJ6C-9 on Image Processing Board and GND remains DC 0 V while the motor is turning. YES: Change Image Processing Board. NO: Change motor. Master Board
- Code: C3720
- Description: Original Glass Cooling Fan Motor turning at abnormal timing
A Lock signal is detected ten consecutive times when it is monitored at 0.01-sec. intervals while a Fan Motor ON signal is being output and, at the same time, after the lapse of 2 sec. or more after the output of the Fan Motor ON signal has been started. - Remedy: 1 Original Glass Cooling Fan Motor rotation: the voltage across PJ2C-6B on Image Processing Board and GND remains DC 0 V while the motor is turning. YES: Change Image Processing Board. NO: Change motor.Bo
- Code: C3A00
- Description: PIC communication error
• A sampling lock is not received after the lapse of a predetermined period of time after IREQ has been received during AIDC sampling of image stabilization sequence or registration adjustment. • There is an open-circuit in the communication harness between the PIC Board and Master Board. • Either the PIC Board or Master Board is faulty. - Remedy: 1 Harnesses and connectors connecting PIC Board to Master Board are in good condition. NO: Change harnesses. Reconnect connectors. 2 The problem has been eliminated through the check of step 1. NO: Change PIC Board. 3 The problem is eliminated after the PIC Board has been replaced. NO: Change Master Board.oard.
- Code: C3A01
- Description: PIC Board malfunction
The PIC Board is faulty. - Remedy: 1 The same malfunction recurs even after the malfunction has been reset, Power Switch turned OFF and ON, and the power cord plugged out and back in. YES: Change PIC Board.
- Code: C3FFF
- Description: ROM contents fault detected upon start
The system fails to rewrite flash memory during updating. - Remedy: 1 This malfunction occurs when an attempt is made to update firmware (rewriting of flash ROM). YES: Try downloading again. 2 The problem has been eliminated through the check of step 1. NO: Change Master Board.
– Buy WIC Reset key on my online store: https://shop.nguyendangnam.com/product/epson-7710-wic-reset-utility-tool/
– Free Download Epson in specific model: https://dnasofts.com/download-epson-ap-4000-s-t-driver-firmware-and-manuals/
Source:
https://dnasofts.com
https://shop.nguyendangnam.com/
https://nguyendangnam.me/
https://chiplessprinter.com/reset-epson-waste-ink-pad-counter.html
Contact us to get support with Kyocera KMC1530 Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/