Fixing Kyocera FS3140MFP plus Printer Error Codes in details
– Printer model: Kyocera FS3140MFP plus
– Fix Error codes on Kyocera FS3140MFP plus model and its description:
- Code: 0030
- Description: FAX control PWB system error
Processing with the fax software was disabled due to a hardware problem. - Causes: Defective FAX control PWB.
- Remedy: Replace the fax control PWB and check for correct operation..
- Code: 0070
- Description: FAX control PWB incompatible detection error
Abnormal detection of FAX control PWB incompatibility In the initial communication with the FAX control PWB, any normal communication command is not transmitted. - Causes: Defective FAX software. Defective FAX control PWB.
- Remedy: Defective FAX software. Install the fax software.
Defective FAX control PWB. Replace the fax control PWB and check for correct operation..
- Code: 0100
- Description: Backup memory device error
- Causes: Defective flash memory. Defective main PWB.
- Remedy: Defective flash memory. Replace the main PWB and check for correct operation.
Defective main PWB. Replace the main PWB and check for correct operation.
- Code: 0120
- Description: MAC address data error
For data in which the MAC address is invalid. - Causes: Defective flash memory. Defective engine PWB.
- Remedy: Defective flash memory. Replace the main PWB and check for correct operation.
Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: 0130
- Description: Backup memory read/ write error (main PWB)
- Causes: Defective flash memory. Defective main PWB.
- Remedy: Defective flash memory. Replace the main PWB and check for correct operation.
Defective main PWB. Replace the main PWB and check for correct operation.
- Code: 0140
- Description: Backup memory data error (main PWB)
- Causes: Defective flash memory. Defective main PWB.
- Remedy: Defective flash memory. Replace the main PWB and check for correct operation.
Defective main PWB. Replace the main PWB and check for correct operation.
- Code: 0150
- Description: Engine PWB EEPROM error
Detecting engine PWB EEPROM communication error. - Causes: Improper installation engine PWB EEPROM. Defective engine PWB. Device damage of EEPROM.
- Remedy: Improper installation engine PWB EEPROM. Check the installation of the EEPROM and remedy if necessary.
Defective engine PWB. Replace the engine PWB and check for correct operation.
Device damage of EEPROM. Contact the Service Administrative Division.
- Code: 0170
- Description: Billing counting error
A checksum error is detected in the main and engine backup memories for the billing counters. - Causes: Data damage of EEPROM. Defective PWB.
- Remedy: Data damage of EEPROM. Contact the Service Administrative Division.
Defective PWB. Replace the main PWB or the engine PWB and check for correct operation.
- Code: 0180
- Description: Machine number mismatch
Machine number of main and engine does not match.. - Causes: Data damage of EEPROM.
- Remedy: Contact the Service Administrative Division.
- Code: 0420
- Description: Paper feeder communication error
Communication error between engine PWB and optional paper feeder. - Causes: Improper installation paper feeder. Defective connector cable or poor contact in the connector. Defective engine PWB. Defective PF main PWB.
- Remedy: Improper installation paper feeder. Follow installation instruction carefully again.
Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Paper feeder interface and connect-L PWB (YC2) Connect-L PWB (YC6) and engine PWB (YC504)
Defective engine PWB. Replace the engine PWB and check for correct operation.
Defective PF main PWB. Replace the PF main PWB.
- Code: 0830
- Description: FAX control PWB flash program area checksum error
A checksum error occurred with the program of the FAX control PWB. - Causes: Defective FAX software. Defective FAX control PWB.
- Remedy: Defective FAX software. Install the fax software.
Defective FAX control PWB. Replace the FAX control PWB.
- Code: 0840
- Description: Faults of RTC
The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed. - Causes: The battery is disconnected from the main PWB. Defective main PWB.
- Remedy: The battery is disconnected from the main PWB. Check visually and remedy if necessary
Defective main PWB. Replace the main PWB and check for correct operation.
- Code: 0870
- Description: FAX control PWB to main PWB high capacity data transfer error
High-capacity data transfer between the FAX control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times.s - Causes: Improper installation FAX control PWB. Defective FAX control PWB or main PWB.
- Remedy: Improper installation FAX control PWB. Reinstall the FAX control PWB.
Defective FAX control PWB or main PWB. Replace the FAX control PWB or main PWB and check for correct operation.
- Code: 0920
- Description: Fax file system error
The backup data is not retained for file system abnormality of flash memory of the FAX control PWB. - Causes: Defective FAX control PWB.
- Remedy: Replace the FAX control PWB and check for correct operation.
- Code: 1010
- Description: Lift motor error
During driving the lift motor, a motor overcurrent signal is detected for 5 s. This error is detected five times successively. - Causes: Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the lift motor. Defective lift motor. Defective engine PWB or connect-R PWB.
- Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Lift motor and connect-R PWB (YC8) Connect-R PWB (YC2) and engine PWB (YC502)
Defective drive transmission system of the lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective lift motor. Replace the lift motor
Defective engine PWB or connect-R PWB. Replace the engine PWB or connect-R PWB and check for correct operation.
- Code: 2000
- Description: Main motor steady-state error
The main motor ready input is not given for 2 s during the main motor is ON. - Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system of the main motor. Defective main motor. Defective engine PWB.
- Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Main motor and engine PWB (YC501)
Defective drive transmission system of the main motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective main motor. Replace the main motor.
Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: 2200
- Description: Drum motor steady-state error
The drum motor ready input is not given for 2 s during the drum motor is ON. - Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system of the drum motor. Defective drum motor. Defective engine PWB.
- Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Drum motor and engine PWB (YC11)
Defective drive transmission system of the drum motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective drum motor. Replace the drum motor.
Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: 3100
- Description: ISU home position error
The home position is not correct when the power is turned on or at the start of copying using the table. - Causes: Defective connector cable or poor contact in the connector. Defective home position sensor. Defective ISU motor. Defective CCD PWB. Defective main PWB.
- Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Home position sensor and CCD PWB (YC3) CCD PWB (YC2) and main PWB (YC8) ISU motor and main PWB (YC1004)
Defective home position sensor. Replace the home position sensor.
Defective ISU motor. Replace the ISU motor.
Defective CCD PWB. Replace the scanner unit.
Defective main PWB. Replace the main PWB and check for correct operation.
- Code: 3200
- Description: Exposure lamp error
When input value at the time of exposure lamp illumination does not exceed the threshold value between 5 s. - Causes: Defective connector cable or poor contact in the connector. Defective exposure lamp or inverter PWB. Defective CCD PWB. Defective main PWB.
- Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Exposure lamp and inverter PWB (YC102) Inverter PWB (YC101) and CCD PWB (YC3) CCD PWB (YC2) and main PWB (YC8)
Defective exposure lamp or inverter PWB. Replace the scanner unit.
Defective CCD PWB. Replace the scanner unit.
Defective main PWB. Replace the main PWB and check for correct operation.
- Code: 3300
- Description: AGC error
After AGC, correct input is not obtained at CCD. - Causes: Defective connector cable or poor contact in the connector. Defective exposure lamp or inverter PWB. Defective CCD PWB. Defective main PWB.
- Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Inverter PWB (YC101) and CCD PWB (YC3) CCD PWB (YC2) and main PWB (YC8)
Defective exposure lamp or inverter PWB. Replace the scanner unit.
Defective CCD PWB. Replace the scanner unit.
Defective main PWB. Replace the main PWB and check for correct operation.
- Code: 3500
- Description: Communication error between scanner and ASIC
An error code is detected. - Causes: Defective connector cable or poor contact in the connector. Defective CCD PWB. Defective main PWB.
- Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. CCD PWB (YC2) and main PWB (YC8)
Defective CCD PWB. Replace the scanner unit.
Defective main PWB. Replace the main PWB and check for correct operation.
- Code: 4000
- Description: Polygon motor synchronization error
The polygon motor ready input is not given for 10 s during the polygon motor is ON. - Causes: Defective connector cable or poor contact in the connector. Defective polygon motor. Defective main PWB.
- Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Laser scanner unit and main PWB (YC14)
Defective polygon motor. Replace the laser scanner unit.
Defective main PWB. Replace the main PWB and check for correct operation.
- Code: 4200
- Description: BD steady-state error
- Causes: Defective connector cable or poor contact in the connector. Defective laser scanner unit. Defective main PWB.
- Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Laser scanner unit and main PWB (YC16)
Defective laser scanner unit. Replace the laser scanner unit.
Defective main PWB. Replace the main PWB and check for correct operation.
- Code: 4700
- Description: VIDEO ASIC device error
Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively. - Causes: Defective connector cable or poor contact in the connector. Defective main PWB or engine PWB.
- Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Main PWB (YC13) and engine PWB (YC12)
Defective main PWB or engine PWB. Replace the main PWB or the engine PWB and check for correct operation.
– Kyocera FS3140MFP plus printer Error Codes and quick guide to troubleshooting:
- Code: 5100
- Description: Main charger high-voltage error
Five pages have been printed with the main charger output short-circuited. - Causes: Drum unit installed incorrectly. Engine PWB installed incorrectly. Defective engine PWB.
- Remedy: Drum unit installed incorrectly. Verify harness is not pinched.
Engine PWB installed incorrectly. Verify harness is not pinched.
Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: 6000
- Description: Broken fuser heater wire
The temperature does not reach 100°C/212°F after the fuser heater has been turned on continuously for 30 s. The temperature does not rise by 1°C/1.8°F after the fuser heater lamp has been turned on continuously for 15 s during warm-up or at standby.(Only when the detection temperature is less than 200°C.) - Causes: Defective connector cable or poor contact in the connector. Fuser thermostat triggered. Broken fuser heater wire.
- Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Fuser heater and power source PWB (YC102) Fuser unit and engine PWB (YC506)
Fuser thermostat triggered. Reinsert the fuser unit.
Broken fuser heater wire. Replace the fuser unit.
- Code: 6020
- Description: Abnormally high fuser thermistor 2 temperature
The temperature of the fuser thermistor 2 detects 250°C/482°F or more continuously for 3 s. - Causes: Shorted fuser thermistor 2. Defective engine PWB.
- Remedy: Shorted fuser thermistor 2. Replace the fuser unit.
Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: 6030
- Description: Broken fuser thermistor 2 wire
average AD value input from fuser thermistor 2 for 1.8 seconds is less than one. (Only when the detection temperature is 50°C or more.) - Causes: Defective connector cable or poor contact in the connector. Broken fuser thermistor 2 wire. Fuser thermostat triggered. Broken fuser heater wire.
- Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Fuser unit and engine PWB (YC506)
Broken fuser thermistor 2 wire. Replace the fuser unit.
Fuser thermostat triggered. Reinsert the fuser unit.
Broken fuser heater wire. Replace the fuser unit.
- Code: 6220
- Description: Abnormally high fuser thermistor 1 temperature
The temperature of the fuser thermistor 1 detects 255°C/491°F or more continuously for 3 s. - Causes: Shorted fuser thermistor 1. Defective engine PWB.
- Remedy: Shorted fuser thermistor 1. Replace the fuser unit.
Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: 6230
- Description: Broken fuser thermistor 1 wire
average AD value input from fuser thermistor 1 for 1.8 seconds is less than one. - Causes: Defective connector cable or poor contact in the connector. Broken fuser thermistor 1 wire. Fuser thermostat triggered. Broken fuser heater wire.
- Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Fuser unit and engine PWB (YC506)
Broken fuser thermistor 1 wire. Replace the fuser unit.
Fuser thermostat triggered. Reinsert the fuser unit.
Broken fuser heater wire. Replace the fuser unit.
- Code: 6400
- Description: Zero-cross signal error
The zero-cross signal does not reach the engine PWB for more than 2 s. - Causes: Defective connector cable or poor contact in the connector. Defective power source PWB. Defective engine PWB.
- Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Power source PWB (YC103) and connect-L PWB (YC1) Connect-L PWB (YC8) and engine PWB (YC503)
Defective power source PWB. Replace the power source PWB and check for correct operation.
Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: 7000
- Description: Toner motor lock error
During driving the toner motor, a motor overcurrent signal is detected for 5 s. - Causes: Lump of toner inside toner container. Defective drive transmission system of the toner motor. Defective toner motor. Defective engine PWB.
- Remedy: Lump of toner inside toner container. Replace the toner container.
Defective drive transmission system of the toner motor. Replace the developing unit.
Defective toner motor. Replace the developing unit.
Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: 7410
- Description: Drum unit non- installing error The drum unit is not installed or not installed properly. The drum PWB EEPROM does not communicate normally.
- Causes: The drum unit is not installed. Defective connector cable or poor contact in the connector. Defective drum PWB EEPROM. Defective engine PWB.
- Remedy: The drum unit is not installed. Install the drum unit.
Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Drum PWB (YC1) and connect-L PWB (YC3)
Defective drum PWB EEPROM. Replace the drum unit.
Defective engine PWB. Replace the engine PWB and check for correct operation.
- Code: 9500
- Description: BRU communication error
- Causes: IPU PWB error
- Remedy: Contact the Service Administrative Division.
- Code: 9510
- Description: BRU PWB error
- Causes: IPU PWB error
- Remedy: Contact the Service Administrative Division.
- Code: 9520
- Description: BRU PWB data error
- Causes: IPU PWB error
- Remedy: Contact the Service Administrative Division.
- Code: F000
- Description: Main PWB – operation panel PWB communication error
- Causes: Defective main PWB. Defective operation panel PWB.
- Remedy: Defective main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
Defective operation panel PWB. Replace the operation panel PWB.
- Code: F020
- Description: Main PWB RAM checksum error
- Causes: Defective main memory (RAM) on the main PWB. Defective expanded memory (DIMM).
- Remedy: Defective main memory (RAM) on the main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
Defective expanded memory (DIMM). Replace the expanded memory (DIMM).
- Code: F040
- Description: Main PWB – engine PWB communication error
- Causes: Defective main PWB. Defective engine PWB.
- Remedy: Defective main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
Defective engine PWB. Replace the engine PWB.
- Code: F041
- Description: Main PWB – scanner communication error
- Causes: Defective main PWB.
- Remedy: Defective main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
- Code: F050
- Description: Engine ROM checksum error
- Causes: Defective engine PWB.
- Remedy: Defective engine PWB. Replace the engine PWB and check for correct operation.
– Buy WIC Reset key on my online store: https://shop.nguyendangnam.com/product/epson-sc-px3v-wic-reset-utility-tool/
– Free Download Epson in specific model: https://dnasofts.com/download-epson-wf-2860-driver-firmware-and-manuals/
Source:
https://dnasofts.com
https://shop.nguyendangnam.com/
https://nguyendangnam.me/
https://chiplessprinter.com/reset-epson-waste-ink-pad-counter.html
Contact us to get support with Kyocera FS3140MFP plus Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/