- Code: 1101
- Description: Life end of the CR MOTOR
The number of carriage movement cycles reached the specified upper limit. - Troubleshooting Guides: Replace the CR MOTOR , perform the necessary adjustments and clear the counter using the Service Program .
- Code: 1125
- Description: Carriage home position detection error
The printer cannot detect the carriage home position. - Troubleshooting Guides: Check whether the CR HP SENSOR is properly connected. Check whether the CR HP SENSOR is correctly installed. Replace the CR HP SENSOR . Check whether the carriage lock properly functions .
- Code: 1133
- Description: CR MOTOR in position time-out error
The CR MOTOR cannot be driven normally. - Troubleshooting Guides: Clean the CR ENC SCALE. Replace the CR MOTOR .
- Code: 1135
- Description: CR ENC ASSY check error
The CR ENC ASSY signals have a defect. - Troubleshooting Guides: Check whether the CR ENC ASSY is properly connected. Check whether the CR MOTOR is properly connected. Replace the CR ENC ASSY . Replace the CR MOTOR .
- Code: 1136
- Description: CR MOTOR step-out error
The CR MOTOR is out of step. - Troubleshooting Guides: Clean the CR ENC SCALE. Check whether the CR HP SENSOR is properly connected. Check whether the CR HP SENSOR is correctly installed. Replace the CR HP SENSOR .
- Code: 1137
- Description: CR servo parameter error
The carriage unit is overloaded abnormally. - Troubleshooting Guides: Check whether any foreign matter is obstructing the carriage movement. If any obstruction is found, remove it. Replace the CR MOTOR .
- Code: 1223
- Description: PF ENCODER ASSY check error
The PF ENCODER ASSY signals have a defect. - Troubleshooting Guides: Check whether the PF ENCODER ASSY is properly connected. Check whether the PF MOTOR is properly connected. Replace the PF MOTOR .
- Code: 1225
- Description: PF MOTOR in position time-out error
The PF MOTOR cannot be driven normally. - Troubleshooting Guides: Replace the PF MOTOR .
- Code: 1227
- Description: PF MOTOR step-out error
The PF MOTOR is out of step. - Troubleshooting Guides: Replace the PF MOTOR .
- Code: 1228
- Description: PF servo parameter error
The PF MOTOR is overloaded abnormally. - Troubleshooting Guides: Check whether any foreign matter is obstructing the PF motor operation. If any obstruction is found, remove it. Replace the PF MOTOR .
- Code: 131B
- Description: Head driver (transmission gate) overheat error
The temperature of the head driver rises, and reaches the specified level. - Troubleshooting Guides: If the PRINT HEAD is operating without ink charged in it, carry out the ink charge sequence. Check whether the Head FFC is properly connected. If not (slant connection or the like), correct it. Replace the PRINT HEAD(s) .
- Code: 1700
- Description: Print position error
The correct print position cannot be detected. - Troubleshooting Guides: Clean the CR ENC SCALE and CR ENCODER ASSY. Replace the CR ENC SCALE . Replace the CR ENC ASSY . Install the latest firmware.
- Code: 1900
- Description: HEATER CONT BOARD ASSY serial connection failure
The serial communication between the MAIN BOARD ASSY and the HEATER CONT BOARD ASSY cannot be made. - Troubleshooting Guides: Check the communication of the serial cable*. Replace the serial cable*.
- Code: 1902
- Description: An abnormally high temperature of the PRE HEATERS(64) on the HEATER RELAY BOARD ASSY
An abnormally high temperature of the PRE HEATERS(64) is detected. - Troubleshooting Guides: Check whether the THERMISTOR, PRE(s) is correctly installed. Replace the HEATER RELAY BOARD ASSY .
- Code: 1903
- Description: An abnormally high temperature of the PLATEN HEATER(64) on the HEATER RELAY BOARD ASSY
An abnormally high temperature of the PLATEN HEATER(64) is detected. - Troubleshooting Guides: Check whether the THERMISTOR, PLATEN(s) is correctly installed. Replace the HEATER RELAY BOARD ASSY .
- Code: 1904
- Description: An abnormally high temperature of the AFTER HEATER(64) on the HEATER RELAY BOARD ASSY
An abnormally high temperature of the AFTER HEATER(64) is detected. - Troubleshooting Guides: Check whether the THERMISTOR, AFTER(s) is correctly installed. Replace the HEATER RELAY BOARD ASSY .
- Code: 1905
- Description: An abnormally low temperature of the PRE HEATERS(64) on the HEATER RELAY BOARD ASSY
An abnormally low temperature of the PRE HEATERS(64) is detected. - Troubleshooting Guides: Check whether the PRE HEATERS(64) are properly connected. Check whether the THERMISTOR, PRE(s) is correctly installed. Check whether the THERMISTOR, PRE(s) is properly connected. Check whether the FUSE has blown. If so, replace the FUSE. Replace the HEATER RELAY BOARD ASSY .
- Code: 1906
- Description: An abnormally low temperature of the PLATEN HEATER(64) on the HEATER RELAY BOARD ASSY
An abnormally low temperature of the PLATEN HEATER(64) is detected. - Troubleshooting Guides: Check whether the PLATEN HEATER(s)(64) is properly connected. Check whether the THERMISTOR, PLATEN(s) is correctly installed. Check whether the THERMISTOR, PLATEN(s) is properly connected. Check whether the FUSE has blown. If so, replace the FUSE. Replace the HEATER RELAY BOARD ASSY .
- Code: 1907
- Description: An abnormally low temperature of the AFTER HEATER(64) on the HEATER RELAY BOARD ASSY
An abnormally low temperature of the AFTER HEATER(64) is detected. - Troubleshooting Guides: Check whether the AFTER HEATER(s)(64) is properly connected. Check whether the THERMISTOR, AFTER(s) is correctly installed. Check whether the THERMISTOR, AFTER(s) is properly connected. Check whether the FUSE has blown. If so, replace the FUSE. Replace the HEATER RELAY BOARD ASSY .
- Code: 1908
- Description: An abnormal voltage of the heater on the HEATER CONT BOARD ASSY
The voltage of the HEATER CONT BOARD ASSY is abnormally changed.d - Troubleshooting Guides: Replace the HEATER CONT BOARD ASSY . Replace the P/S BOARD ASSY .
- Code: 1909
- Description: Serial communication failure between the HEATER CONT BOARD ASSY and SUB-B/C BOARD
The serial communication between the HEATER CONT BOARD ASSY and the SUB_B BOARD ASSY/SUB_C BOARD ASSY cannot be made. - Troubleshooting Guides: Check whether the serial cable is properly connected. If not, connect it properly.
- Code: 1910
- Description: Insufficient temperature of the PRE HEATERS(64) on the HEATER RELAY BOARD ASSY
The required temperature of the PRE HEATERS(64) cannot be reached. - Troubleshooting Guides: Check whether the AC cable for the heater is properly connected. If not, connect the cable properly. Check whether the THERMISTOR, PRE(s) is correctly installed. Check whether the THERMISTOR, PRE(s) is properly connected. Check whether the FUSE has blown. If so, replace the FUSE. Replace the HEATER RELAY BOARD ASSY .
- Code: 1911
- Description: Insufficient temperature of the PLATEN HEATER(64) on the HEATER RELAY BOARD ASSY
The required temperature of the PLATEN HEATER(64) cannot be reached. - Troubleshooting Guides: Check whether the AC cable for the heater is properly connected. If not, connect the cable properly. Check whether the THERMISTOR, PLATEN(s) is correctly installed. Check whether the THERMISTOR, PLATEN(s) is properly connected. Check whether the FUSE has blown. If so, replace the FUSE. Replace the HEATER RELAY BOARD ASSY .
- Code: 1912
- Description: Insufficient temperature of the AFTER HEATER(64) on the HEATER RELAY BOARD ASSY
The required temperature of the AFTER HEATER(64) cannot be reached. - Troubleshooting Guides: Check whether the AC cable for the heater is properly connected. If not, connect the cable properly. Check whether the THERMISTOR, AFTER(s) is correctly installed. Check whether the THERMISTOR, AFTER(s) is properly connected. Check whether the FUSE has blown. If so, replace the FUSE. Replace the HEATER RELAY BOARD ASSY .
- Code: 1920
- Description: HEATER CONT BOARD ASSYSUB TANK SENSOR 1 failure
The High sensor for the sub tank 1 is ON (ink exists), but the Low senor is OFF. - Troubleshooting Guides: Check whether the SUB TANK SENSOR is properly connected. Replace the SUB TANK SENSOR .
- Code: 1921
- Description: HEATER CONT BOARD ASSYSUB TANK SENSOR 2 failure
The High sensor for the sub tank 2 is ON (ink exists), but the Low senor is OFF. - Troubleshooting Guides: Check whether the SUB TANK SENSOR is properly connected. Replace the SUB TANK SENSOR .
- Code: 1922
- Description: HEATER CONT BOARD ASSYSUB TANK SENSOR 3 failure
The High sensor for the sub tank 3 is ON (ink exists), but the Low senor is OFF. - Troubleshooting Guides: Check whether the SUB TANK SENSOR is properly connected. Replace the SUB TANK SENSOR .
- Code: 1923
- Description: HEATER CONT BOARD ASSYSUB TANK SENSOR 4 failure
The High sensor for the sub tank 4 is ON (ink exists), but the Low senor is OFF. - Troubleshooting Guides: Check whether the SUB TANK SENSOR is properly connected. Replace the SUB TANK SENSOR .
- Code: 1924
- Description: HEATER CONT BOARD ASSYSUB TANK SENSOR 5 failure
The High sensor for the sub tank 5 is ON (ink exists), but the Low senor is OFF. - Troubleshooting Guides: Check whether the SUB TANK SENSOR is properly connected. Replace the SUB TANK SENSOR .
- Code: 1925
- Description: HEATER CONT BOARD ASSYSUB TANK SENSOR 6 failure
The High sensor for the sub tank 6 is ON (ink exists), but the Low senor is OFF. - Troubleshooting Guides: Check whether the SUB TANK SENSOR is properly connected. Replace the SUB TANK SENSOR .
- Code: 1926
- Description: HEATER CONT BOARD ASSYSUB TANK SENSOR 7 failure
The High sensor for the sub tank 7 is ON (ink exists), but the Low senor is OFF. - Troubleshooting Guides: Check whether the SUB TANK SENSOR is properly connected. Replace the SUB TANK SENSOR .
- Code: 1927
- Description: HEATER CONT BOARD ASSYSUB TANK SENSOR 8 failure
The High sensor for the sub tank 8 is ON (ink exists), but the Low senor is OFF. - Troubleshooting Guides: Check whether the SUB TANK SENSOR is properly connected. Replace the SUB TANK SENSOR .
- Code: 1A23
- Description: RTC analysis error
The value information on various absolute time stored on NVRAM is abnormal. - Troubleshooting Guides: Check if the lithium battery is installed properly. Replace the MAIN BOARD ASSY .
- Code: 1A26
- Description: RTC communication error
The communication with the RTC circuit cannot be made. - Troubleshooting Guides: Replace the MAIN BOARD ASSY .
- Code: 1A37
- Description: Head thermistor error
There is something wrong with the Head FFC connection. The Head Thermistor detects a temperature out of the specification. The Head Thermistor has a defect.8). - Troubleshooting Guides: Check whether the Head FFC is properly connected. If not (slant connection or the like), correct it. Replace the PRINT HEAD(s) .
- Code: 1A38
- Description: Transistor thermistor error
The transistor is faulty. The thermistor detects a temperature out of the specification. - Troubleshooting Guides: Replace the PRINT HEAD(s) .
- Code: 1A39
- Description: Head error
The active signal of head error has been detected. - Troubleshooting Guides: Replace the PRINT HEAD(s) .
- Code: 1A40
- Description: MAIN BOARD ASSY IC2 error
The active signal of head error has been detected. - Troubleshooting Guides: Replace the PRINT HEAD(s) .
- Code: 1A41
- Description: Head rank ID input error
The information of the Head rank ID is wrong. - Troubleshooting Guides: Configure the head rank ID again.
- Code: 2000
- Description: NVRAM error
NVRAM erase or write error has occurred. - Troubleshooting Guides: Replace the MAIN BOARD ASSY .
- Code: 2003
- Description: Boot program sum error
Installation of the firmware has been failed. The Flash ROM is faulty. - Troubleshooting Guides: Install the main firmware again. Replace the MAIN BOARD ASSY . Replace the MAIN BOARD ASSY .
- Code: 200A
- Description: Program loading error
The SDRAM is faulty. The program cannot be loaded on the SDRAM. - Troubleshooting Guides: Replace the MAIN BOARD ASSY .
Solve Epson Stylus Pro GS6000 Error codes
- Code: 200B
- Description: Internal insufficient memory error
The main firmware has a defect. - Troubleshooting Guides: Install the correct main firmware.
- Code: 200C
- Description: Servo interrupt watchdog time-out error
The servo cannot be controlled. - Troubleshooting Guides: Install the correct main firmware. Replace the MAIN BOARD ASSY .
- Code: 200D
- Description: System interrupt watchdog timeout error
A system failure such as CPU failure, defective cash or the like has occurred. - Troubleshooting Guides: Replace the MAIN BOARD ASSY .
- Code: 200E
- Description: Unknown NMI
The CPU has detected an unknown NMI. - Troubleshooting Guides: Replace the MAIN BOARD ASSY .
- Code: 3000
- Description: AC power shut-off
The AC power has been shut off due to a power failure, unplugged, P/S BOARD ASSY failure, or MAIN BOARD ASSY failure or the like. - Troubleshooting Guides: Check whether the AC cable is properly connected. If not, correct it. Replace the P/S BOARD ASSY . Replace the MAIN BOARD ASSY .
- Code: FXXX
- Description: CPU-related error
The firmware has a defect. The MAIN BOARD ASSY is broken. - Troubleshooting Guides: Install the correct main firmware. Replace the MAIN BOARD ASSY .
– Get more error code list with quick guide to fix printer product, click here
– About get help with reseting Epson inkpad or others, click here
– Get more information about Epson XP 15000 troubleshooting, click here
– Shop on my shop, click here
Contact us to get support with Epson Stylus Pro GS6000 Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.